Alex Wynn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alex Wynn has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Sergey K. Tolpygo
MIT Lincoln Laboratory
4 shared publications Chad Rogers
High Precision Devices, Boulder, CO, USA
2 shared publicationsEvan Golden
Massachusetts Institute of Technology Lincoln Laboratory, Massachusetts Institute of Technology, Lexington, MA, USA
2 shared publications- L. Camron Blackburn
Massachusetts Institute of Technology in Cambridge, Cambridge, MA, USA
2 shared publications - Nancy Missert
Sandia National Laboratories, Albuquerque, NM, USA
2 shared publications Neil Gershenfeld
Massachusetts Institute of Technology in Cambridge, Cambridge, MA, USA
2 shared publications
Latest Publications
- 24 April 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (4)
Flux-trapping characterization for superconducting electronics using a cryogenic widefield N- V diamond microscope
- 24 April 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (4)
Flux-trapping characterization for superconducting electronics using a cryogenic widefield N- V diamond microscope
- Open Access
- 11 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
A Compact Bit Serial Memory Cell for Adiabatic Quantum Flux Parametron Register Files
The Adiabatic Quantum Flux Parametron (AQFP) superconducting logic family is an attractive beyond-CMOS technology due to its extreme energy efficiency. As AQFP circuits become more complex and target applications scale to microprocessors and ASICs, a high performance and area efficient register-level memory design is essential. In this work, we design and implement a 3-bit memory cell based on a simple Set-Reset (SR) latch attached to a shift register feedback loop. This design is more compact than existing AQFP registers that encode data with Data-Enable logic and therefore require larger XOR-style gates for every 1-bit cell [1]. Furthermore, we share layout design and simulation results for scaling this circuit to an 8-bit memory cell and a N-row × M-col × 8-bit register file. By using SR data encoding, we are able to join the cells in an array using more compact AND gates, performing cell-level addressing with two write demuxes and two read decoders. Projecting our initial designs to a 32-word by 8-bit register file, we find that our SR-loop memory array has a 26% decrease in area compared to other state-of-the-art designs.
- 11 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Open AccessA Compact Bit Serial Memory Cell for Adiabatic Quantum Flux Parametron Register Files
The Adiabatic Quantum Flux Parametron (AQFP) superconducting logic family is an attractive beyond-CMOS technology due to its extreme energy efficiency. As AQFP circuits become more complex and target applications scale to microprocessors and ASICs, a high performance and area efficient register-level memory design is essential. In this work, we design and implement a 3-bit memory cell based on a simple Set-Reset (SR) latch attached to a shift register feedback loop. This design is more compact than existing AQFP registers that encode data with Data-Enable logic and therefore require larger XOR-style gates for every 1-bit cell [1]. Furthermore, we share layout design and simulation results for scaling this circuit to an 8-bit memory cell and a N-row × M-col × 8-bit register file. By using SR data encoding, we are able to join the cells in an array using more compact AND gates, performing cell-level addressing with two write demuxes and two read decoders. Projecting our initial designs to a 32-word by 8-bit register file, we find that our SR-loop memory array has a 26% decrease in area compared to other state-of-the-art designs.
- 3 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-7
Integrated Superconducting Transition-Edge-Sensor Energy Readout (ISTER)
We describe a million-pixel-scale multiplexed readout for superconducting Transition Edge Sensor (TES) microcalorimeters, using Rapid Single Flux Quantum (RSFQ) digital circuits. Depending on the application and the power dissipation requirements, the readout circuits may be either fabricated on the same wafer as the TES or integrated with the TES wafer using a multichip module, thereby integrating the TES and readout circuits. A data reduction scheme in the RSFQ circuits is described, using integrating counters to measure the TES pulse area. Power and clock requirements for measuring a large number of TES channels per readout line are discussed. Basic components of the ISTER readout circuit have been fabricated in the SFQ5ee process at MIT Lincoln Laboratory and operated at 4 K. The fab process has eight fully planarized Nb layers and one layer of Nb/Al-AlOx/Nb Josephson junctions with 100 $\mu$ A/ $\mu$ m $^{2}$ critical current density. Simulations of a TES read out are performed to investigate possible limits on energy resolution using ISTER.
- 3 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-7
Integrated Superconducting Transition-Edge-Sensor Energy Readout (ISTER)
We describe a million-pixel-scale multiplexed readout for superconducting Transition Edge Sensor (TES) microcalorimeters, using Rapid Single Flux Quantum (RSFQ) digital circuits. Depending on the application and the power dissipation requirements, the readout circuits may be either fabricated on the same wafer as the TES or integrated with the TES wafer using a multichip module, thereby integrating the TES and readout circuits. A data reduction scheme in the RSFQ circuits is described, using integrating counters to measure the TES pulse area. Power and clock requirements for measuring a large number of TES channels per readout line are discussed. Basic components of the ISTER readout circuit have been fabricated in the SFQ5ee process at MIT Lincoln Laboratory and operated at 4 K. The fab process has eight fully planarized Nb layers and one layer of Nb/Al-AlOx/Nb Josephson junctions with 100 $\mu$ A/ $\mu$ m $^{2}$ critical current density. Simulations of a TES read out are performed to investigate possible limits on energy resolution using ISTER.
- 16 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (6) , 1-12
Low-Cost Superconducting Fan-Out With Cell $\text{I}_\text{C}$ RankingSuperconductor electronics (SCE) promise computer systems with orders of magnitude higher speeds and lower energy consumption than their complementary metal–oxide semiconductor (CMOS) counterparts. At the same time, the scalability and resource utilization of superconducting systems are major concerns. Some of these concerns come from device-level challenges and the gap between SCE and CMOS technology nodes, and others come from the way Josephson junctions (JJs) are used. Toward this end, we notice that a considerable fraction of hardware resources are not involved in logic operations, but rather are used for fan-out and buffering purposes. In this article, we ask if there is a way to reduce these overheads, propose the use of JJs at the cell boundaries to increase the number of outputs that a single stage can drive, and establish a set of rules to discretize critical currents in a way that is conducive to this assignment. Finally, we explore the design trade-offs that the presented approach opens up and demonstrate its promise through detailed analog simulations and modeling analyses. Our experiments indicate that the introduced method leads to a 48% savings in the JJ count for a tree with a fan-out of 1024, as well as an average of 43% of the JJ count for signal splitting and 32% for clock splitting in ISCAS'85 benchmarks.
- 16 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (6) , 1-12
Low-Cost Superconducting Fan-Out With Cell $\text{I}_\text{C}$ RankingSuperconductor electronics (SCE) promise computer systems with orders of magnitude higher speeds and lower energy consumption than their complementary metal–oxide semiconductor (CMOS) counterparts. At the same time, the scalability and resource utilization of superconducting systems are major concerns. Some of these concerns come from device-level challenges and the gap between SCE and CMOS technology nodes, and others come from the way Josephson junctions (JJs) are used. Toward this end, we notice that a considerable fraction of hardware resources are not involved in logic operations, but rather are used for fan-out and buffering purposes. In this article, we ask if there is a way to reduce these overheads, propose the use of JJs at the cell boundaries to increase the number of outputs that a single stage can drive, and establish a set of rules to discretize critical currents in a way that is conducive to this assignment. Finally, we explore the design trade-offs that the presented approach opens up and demonstrate its promise through detailed analog simulations and modeling analyses. Our experiments indicate that the introduced method leads to a 48% savings in the JJ count for a tree with a fan-out of 1024, as well as an average of 43% of the JJ count for signal splitting and 32% for clock splitting in ISCAS'85 benchmarks.
- Open Access
- 8 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Design and Simulation of Phase Synchronizer for Adiabatic Quantum Flux Parametron Circuits
An adiabatic quantum flux parametron (AQFP) is a two-terminal superconducting device capable of amplifying or inverting digital input signals at near-kT energy dissipation. This ultra-low power device is desirable for myriad reasons, including high performance accelerator applications as CMOS processors become more and more limited by energy consumption. Promising performance results have been realized on AQFP processors; however, scaling these results to larger computing systems faces engineering challenges due to device density and power distribution. AQFP circuits require a multi-phase activation signal to propagate logic. If data is not properly aligned with the activation phase, it can be dropped or shifted to an incorrect phase and disrupt circuit operation. This work presents design and simulation of an activation phase synchronizer: a simple circuit that will accept data arriving on any phase and re-align it to a known phase of the subsequent cycle. The phase synchronizer can be useful for mitigating clock skew across clock domains or play an important role in asynchronous design where the arrival time of data may be unknown.
- 8 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Open AccessDesign and Simulation of Phase Synchronizer for Adiabatic Quantum Flux Parametron Circuits
An adiabatic quantum flux parametron (AQFP) is a two-terminal superconducting device capable of amplifying or inverting digital input signals at near-kT energy dissipation. This ultra-low power device is desirable for myriad reasons, including high performance accelerator applications as CMOS processors become more and more limited by energy consumption. Promising performance results have been realized on AQFP processors; however, scaling these results to larger computing systems faces engineering challenges due to device density and power distribution. AQFP circuits require a multi-phase activation signal to propagate logic. If data is not properly aligned with the activation phase, it can be dropped or shifted to an incorrect phase and disrupt circuit operation. This work presents design and simulation of an activation phase synchronizer: a simple circuit that will accept data arriving on any phase and re-align it to a known phase of the subsequent cycle. The phase synchronizer can be useful for mitigating clock skew across clock domains or play an important role in asynchronous design where the arrival time of data may be unknown.
- 5 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (5) , 1-12
Wafer-Scale Characterization of a Superconductor Integrated Circuit Fabrication Process, Using a Cryogenic Wafer Prober
Using a fully automated cryogenic wafer prober, we measured superconductor fabrication process control monitors and simple integrated circuits on 200-mm wafers at 4.4 K, including SQIF-based magnetic field sensors, SQUID-based circuits for measuring inductors, Nb/Al-AlO x /Nb Josephson junctions, test structures for measuring critical current of superconducting wires and vias, resistors, etc., to demonstrate the feasibility of using the system for characterizing niobium superconducting devices and integrated circuits on a wafer scale. Data on the wafer-scale distributions of the residual magnetic field, junction tunnel resistance, energy gap, inductance of multiple Nb layers, and critical currents of interlayer vias are presented. A comparison with existing models is made. The wafers were fabricated in the SFQ5ee process, the fully planarized process with eight niobium layers and a layer of kinetic inductors, developed for superconductor electronics at MIT Lincoln Laboratory, Lexington, MA, USA. The cryogenic wafer prober was developed at HPD/FormFactor, Inc., Boulder, CO, USA.
- 5 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (5) , 1-12
Wafer-Scale Characterization of a Superconductor Integrated Circuit Fabrication Process, Using a Cryogenic Wafer Prober
Using a fully automated cryogenic wafer prober, we measured superconductor fabrication process control monitors and simple integrated circuits on 200-mm wafers at 4.4 K, including SQIF-based magnetic field sensors, SQUID-based circuits for measuring inductors, Nb/Al-AlO x /Nb Josephson junctions, test structures for measuring critical current of superconducting wires and vias, resistors, etc., to demonstrate the feasibility of using the system for characterizing niobium superconducting devices and integrated circuits on a wafer scale. Data on the wafer-scale distributions of the residual magnetic field, junction tunnel resistance, energy gap, inductance of multiple Nb layers, and critical currents of interlayer vias are presented. A comparison with existing models is made. The wafers were fabricated in the SFQ5ee process, the fully planarized process with eight niobium layers and a layer of kinetic inductors, developed for superconductor electronics at MIT Lincoln Laboratory, Lexington, MA, USA. The cryogenic wafer prober was developed at HPD/FormFactor, Inc., Boulder, CO, USA.
- Open Access
Wafer-Scale Characterization of a Superconductor Integrated Circuit Fabrication Process, Using a Cryogenic Wafer Prober
Using a fully automated cryogenic wafer prober, we measured superconductor fabrication process control monitors and simple integrated circuits on 200 mm wafers at 4.4 K, including SQIF-based magnetic field sensors, SQUID-based circuits for measuring inductors, Nb/Al-AlOx/Nb Josephson junctions, test structures for measuring critical current of superconducting wires and vias, resistors, etc., to demonstrate the feasibility of using the system for characterizing niobium superconducting devices and integrated circuits on a wafer scale. Data on the wafer-scale distributions of the residual magnetic field, junction tunnel resistance, energy gap, inductance of multiple Nb layers, critical currents of interlayer vias are presented. Comparison with existing models is made. The wafers were fabricated in the SFQ5ee process, the fully planarized process with eight niobium layers and a layer of kinetic inductors, developed for superconductor electronics at MIT Lincoln Laboratory. The cryogenic wafer prober was developed at HPD/ FormFactor, Inc.
Open AccessWafer-Scale Characterization of a Superconductor Integrated Circuit Fabrication Process, Using a Cryogenic Wafer Prober
Using a fully automated cryogenic wafer prober, we measured superconductor fabrication process control monitors and simple integrated circuits on 200 mm wafers at 4.4 K, including SQIF-based magnetic field sensors, SQUID-based circuits for measuring inductors, Nb/Al-AlOx/Nb Josephson junctions, test structures for measuring critical current of superconducting wires and vias, resistors, etc., to demonstrate the feasibility of using the system for characterizing niobium superconducting devices and integrated circuits on a wafer scale. Data on the wafer-scale distributions of the residual magnetic field, junction tunnel resistance, energy gap, inductance of multiple Nb layers, critical currents of interlayer vias are presented. Comparison with existing models is made. The wafers were fabricated in the SFQ5ee process, the fully planarized process with eight niobium layers and a layer of kinetic inductors, developed for superconductor electronics at MIT Lincoln Laboratory. The cryogenic wafer prober was developed at HPD/ FormFactor, Inc.
- 9 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-4
Diagnosis of Factors Impacting Yield in Multilayer Devices for Superconducting Electronics
The ability to localize defects in order to understand failure mechanisms in complex superconducting electronics circuits, while operating at low temperature, does not yet exist. This work applies thermally-induced voltage alteration (TIVA), to a biased superconducting electronics (SCE) circuit at ambient temperature. TIVA is a commonly used, laser-based failure analysis technique developed for silicon-based microelectronics. The non-operational circuit consisted of an arithmetic logic unit (ALU) in a high-frequency test bed designed at HYPRES and fabricated by MIT Lincoln Laboratory using their SFQ5ee process. Localized TIVA signals were correlated with reflected light images at the surface, and these sites were further investigated by scanning electron microscopy imaging of focused ion-beam cross-sections. The areas investigated, where prominent TIVA signals were observed, showed seams in the Nb wiring layers at contacts to Josephson junctions or inductors and/or disrupted junction morphologies. These results suggest that the TIVA technique can be used at ambient temperature to diagnose fabrication defects that may cause low temperature circuit failure.
- 9 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-4
Diagnosis of Factors Impacting Yield in Multilayer Devices for Superconducting Electronics
The ability to localize defects in order to understand failure mechanisms in complex superconducting electronics circuits, while operating at low temperature, does not yet exist. This work applies thermally-induced voltage alteration (TIVA), to a biased superconducting electronics (SCE) circuit at ambient temperature. TIVA is a commonly used, laser-based failure analysis technique developed for silicon-based microelectronics. The non-operational circuit consisted of an arithmetic logic unit (ALU) in a high-frequency test bed designed at HYPRES and fabricated by MIT Lincoln Laboratory using their SFQ5ee process. Localized TIVA signals were correlated with reflected light images at the surface, and these sites were further investigated by scanning electron microscopy imaging of focused ion-beam cross-sections. The areas investigated, where prominent TIVA signals were observed, showed seams in the Nb wiring layers at contacts to Josephson junctions or inductors and/or disrupted junction morphologies. These results suggest that the TIVA technique can be used at ambient temperature to diagnose fabrication defects that may cause low temperature circuit failure.
- 12 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-7
Reliability Studies of Nb/AlO x /Al/Nb Josephson Junctions Through Accelerated-Life Electrical Stress Testing
Reliability studies have been performed on $\rm Nb/AlO_{x}/Al/Nb$ trilayer Josephson junctions with a critical current density of 100 $\rm 100 \mu A/\mu m^2$ with emphasis on reliability of the thin $\rm AlO_x$ dielectric tunnel barrier. High current stress tests at 4.2 K involving ramp-to-failure and time-dependent stress profiles have been used to accelerate the barrier degradation process while monitoring changes through DC characterization of the tunnel junctions. Tun-neling characteristics of the junctions have been found to deteriorate with increasing stress magnitudes, suggesting breakdown mecha-nisms depending on the magnitude and polarity of the applied stress or the time-duration of applied stress. The typically observed stress effects can be ascribed to a reduction in the effective barrier thick-ness or increase in barrier transparency, and corresponding to the formation of conduction channels through the barrier above a threshold stress current. Significant stress current polarity depend-ence has been observed and described.- 12 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-7
Reliability Studies of Nb/AlO x /Al/Nb Josephson Junctions Through Accelerated-Life Electrical Stress Testing
Reliability studies have been performed on $\rm Nb/AlO_{x}/Al/Nb$ trilayer Josephson junctions with a critical current density of 100 $\rm 100 \mu A/\mu m^2$ with emphasis on reliability of the thin $\rm AlO_x$ dielectric tunnel barrier. High current stress tests at 4.2 K involving ramp-to-failure and time-dependent stress profiles have been used to accelerate the barrier degradation process while monitoring changes through DC characterization of the tunnel junctions. Tun-neling characteristics of the junctions have been found to deteriorate with increasing stress magnitudes, suggesting breakdown mecha-nisms depending on the magnitude and polarity of the applied stress or the time-duration of applied stress. The typically observed stress effects can be ascribed to a reduction in the effective barrier thick-ness or increase in barrier transparency, and corresponding to the formation of conduction channels through the barrier above a threshold stress current. Significant stress current polarity depend-ence has been observed and described.- Open Access
- 15 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 27 (4) , 1-4
Analysis of Multilayer Devices for Superconducting Electronics by High-Resolution Scanning Transmission Electron Microscopy and Energy Dispersive Spectroscopy
A focused ion beam was used to obtain cross-sectional specimens from both magnetic multilayer and Nb/Al-AlOx/Nb Josephson junction devices for characterization by scanning transmission electron microscopy (STEM) and energy dispersive X-ray spectroscopy (EDX). Automated multivariate statistical analysis of the EDX spectral images produced chemically unique component images of individual layers within the multilayer structures. STEM imaging elucidated distinct variations in film morphology, interface quality, and/or etch artifacts that could be correlated to magnetic and/or electrical properties measured on the same devices.
- 15 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 27 (4) , 1-4
Open AccessAnalysis of Multilayer Devices for Superconducting Electronics by High-Resolution Scanning Transmission Electron Microscopy and Energy Dispersive Spectroscopy
A focused ion beam was used to obtain cross-sectional specimens from both magnetic multilayer and Nb/Al-AlOx/Nb Josephson junction devices for characterization by scanning transmission electron microscopy (STEM) and energy dispersive X-ray spectroscopy (EDX). Automated multivariate statistical analysis of the EDX spectral images produced chemically unique component images of individual layers within the multilayer structures. STEM imaging elucidated distinct variations in film morphology, interface quality, and/or etch artifacts that could be correlated to magnetic and/or electrical properties measured on the same devices.