Tianmiao Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tianmiao Wang has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Lei Hu
School of Mechanical Engineering and Automation Beihang University Beijing China
3 shared publications- Na Guo
School of Computer and Communication Engineering, University of Science and Technology Beijing, Beijing, China
3 shared publications Biao Yang
School of Mechanical Engineering and Automation, Beihang University, Beijing 100083, China
2 shared publications- Huangying Yu
Shanghai University
2 shared publications - Jingtao Lei
School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China
2 shared publications Yuhan Wang
School of Mechanical Engineering and Automation, Beihang University, Beijing 100083, China
2 shared publications
Latest Publications
- 9 April 2021
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 17 (4)
A robotic system for spine surgery positioning and pedicle screw placement
Background: In recent years, surgeons have explored minimally invasive methods of percutaneous pedicle screw implantation which can effectively reduce human injuries. This article presents an accurate and efficient positioning method and robot system for percutaneous needle placement under c‐arm fluoroscopy.Methods: A simple five degree of freedom (DOF) robot with a unique end‐effector is designed to perform perspective calibration and image space registration. The principle of pedicle standard axis positioning is adopted to make the axis of the pedicle overlap with the x‐ray axis of c‐arm.Results: Then the clinical operation is carried out to verify the clinical feasibility of the designed robot and positioning method. The experimental results show that a total of 26 pedicle screws were accurately implanted. The accuracy of Grade A is 96.15%. The positioning time of a single guide pin is about 154.77 s, and three x‐ray films need to be taken on average.Conclusions: The positioning accuracy is increased by using the present method. In addition, this method is simple in operation, short in operation time, low in X‐ray exposure.
- 9 April 2021
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 17 (4)
A robotic system for spine surgery positioning and pedicle screw placement
Background: In recent years, surgeons have explored minimally invasive methods of percutaneous pedicle screw implantation which can effectively reduce human injuries. This article presents an accurate and efficient positioning method and robot system for percutaneous needle placement under c‐arm fluoroscopy.Methods: A simple five degree of freedom (DOF) robot with a unique end‐effector is designed to perform perspective calibration and image space registration. The principle of pedicle standard axis positioning is adopted to make the axis of the pedicle overlap with the x‐ray axis of c‐arm.Results: Then the clinical operation is carried out to verify the clinical feasibility of the designed robot and positioning method. The experimental results show that a total of 26 pedicle screws were accurately implanted. The accuracy of Grade A is 96.15%. The positioning time of a single guide pin is about 154.77 s, and three x‐ray films need to be taken on average.Conclusions: The positioning accuracy is increased by using the present method. In addition, this method is simple in operation, short in operation time, low in X‐ray exposure.
- Open Access
- 23 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 101795-101803
An Online Calibration Method for Microsoft HoloLens
An optical see-through (OST) head mounted display (HMD) is an appropriate option for image-guided surgical navigation system (IGS) based on augmented reality (AR). However, the calibration of OST-HMDs has been challenging, since the augmented results can only be observed by the users wearing it. In this paper, we proposed an online calibration method based on the single point active alignment method (SPAAM) for a HoloLens using a virtual tracking system. The transformation matrices between the world coordinates to the virtual holographic coordinates are calculated using a linear model and decomposed by the Singular Value Decomposition (SVD) algorithm. The surgical workspace is analyzed, and there are nine sampling points for the offline calibration, including eight at the vertices and one at the center of a cube of the workspace. 20 groups of data at each sampling point are collected. 5 alignments should be implanted in the online calibration. The transformation matrices are compensated for the offset of every use of a HoloLens. To assess the accuracy of the calibration method, in accordance with the RANSAC algorithm, 8 groups of additional data at random non-sampling locations are collected. Three different users that are familiar with the calibration procedures performed the calibration. The average distance error of our calibration was below 6 mm, and the rotation error was up to 5°. It is a user-friendly, simple method for the online calibration of OST-HMDs.
- 23 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 101795-101803
Open AccessAn Online Calibration Method for Microsoft HoloLens
An optical see-through (OST) head mounted display (HMD) is an appropriate option for image-guided surgical navigation system (IGS) based on augmented reality (AR). However, the calibration of OST-HMDs has been challenging, since the augmented results can only be observed by the users wearing it. In this paper, we proposed an online calibration method based on the single point active alignment method (SPAAM) for a HoloLens using a virtual tracking system. The transformation matrices between the world coordinates to the virtual holographic coordinates are calculated using a linear model and decomposed by the Singular Value Decomposition (SVD) algorithm. The surgical workspace is analyzed, and there are nine sampling points for the offline calibration, including eight at the vertices and one at the center of a cube of the workspace. 20 groups of data at each sampling point are collected. 5 alignments should be implanted in the online calibration. The transformation matrices are compensated for the offset of every use of a HoloLens. To assess the accuracy of the calibration method, in accordance with the RANSAC algorithm, 8 groups of additional data at random non-sampling locations are collected. Three different users that are familiar with the calibration procedures performed the calibration. The average distance error of our calibration was below 6 mm, and the rotation error was up to 5°. It is a user-friendly, simple method for the online calibration of OST-HMDs.
- 7 May 2019
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 15 (4) , e2008
Intensity‐based 2D‐3D registration for an ACL reconstruction navigation system
To improve the positioning accuracy of tunnels for anterior cruciate ligament (ACL) reconstruction, we proposed an intensity‐based 2D‐3D registration method for an ACL reconstruction navigation system. Methods for digitally reconstructed radiograph (DRR) generation, similarity measurement, and optimization are crucial to 2D‐3D registration. We evaluated the accuracy, success rate, and processing time of different methods: (a) ray‐casting and splating were compared for DRR generation; (b) normalized mutual information (NMI), Mattes mutual information (MMI), and Spearman's rank correlation coefficient (SRC) were assessed for similarity between registrations; and (c) gradient descent (GD) and downhill simplex (DS) were compared for optimization. The combination of splating, SRC, and GD provided the best composite performance and was applied in an augmented reality (AR) ACL reconstruction navigation system. The accuracy of the navigation system could fulfill the clinical needs of ACL reconstruction, with an end pose error of 2.50 mm and an angle error of 2.74°.
- 7 May 2019
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 15 (4) , e2008
Intensity‐based 2D‐3D registration for an ACL reconstruction navigation system
To improve the positioning accuracy of tunnels for anterior cruciate ligament (ACL) reconstruction, we proposed an intensity‐based 2D‐3D registration method for an ACL reconstruction navigation system. Methods for digitally reconstructed radiograph (DRR) generation, similarity measurement, and optimization are crucial to 2D‐3D registration. We evaluated the accuracy, success rate, and processing time of different methods: (a) ray‐casting and splating were compared for DRR generation; (b) normalized mutual information (NMI), Mattes mutual information (MMI), and Spearman's rank correlation coefficient (SRC) were assessed for similarity between registrations; and (c) gradient descent (GD) and downhill simplex (DS) were compared for optimization. The combination of splating, SRC, and GD provided the best composite performance and was applied in an augmented reality (AR) ACL reconstruction navigation system. The accuracy of the navigation system could fulfill the clinical needs of ACL reconstruction, with an end pose error of 2.50 mm and an angle error of 2.74°.
- Open Access
New Calibrator with Points Distributed Conical Helically for Online Calibration of C-Arm
To improve the accuracy of calibration of C-arm, and overcome the space limitation in surgery, we proposed a new calibrator for online calibration of C-arm. After the image rectification by a polynomial fitting-based global correction method, the C-arm was assumed as an ideal pinhole model. The relationships between two kinds of spatial calibration errors and the distribution of fiducial points were studied: the performance of FRE (Fiducial Registration Error) and TRE (Target Registration Error) were not consistent, but both were best at the 12 marked points; the TRE decreased with the increase of the uniformity of calibration points distribution, and with the decrease of the distance between the target point and the center of calibration points. A calibrator with 12 fiducial points conical helically distributed, which could be placed on the knee, was an attractive option. A total of 10 experiments on C-arm calibration accuracy were conducted and the mean value of mapping error was 0.41 mm. We designed an ACL reconstruction navigation system and carried out specimen experiments on 4 pairs of dry femur and tibia. The mean accuracy of navigation system was 0.85 mm, which is important to the tunnel positioning for ACL reconstruction.
Open AccessNew Calibrator with Points Distributed Conical Helically for Online Calibration of C-Arm
To improve the accuracy of calibration of C-arm, and overcome the space limitation in surgery, we proposed a new calibrator for online calibration of C-arm. After the image rectification by a polynomial fitting-based global correction method, the C-arm was assumed as an ideal pinhole model. The relationships between two kinds of spatial calibration errors and the distribution of fiducial points were studied: the performance of FRE (Fiducial Registration Error) and TRE (Target Registration Error) were not consistent, but both were best at the 12 marked points; the TRE decreased with the increase of the uniformity of calibration points distribution, and with the decrease of the distance between the target point and the center of calibration points. A calibrator with 12 fiducial points conical helically distributed, which could be placed on the knee, was an attractive option. A total of 10 experiments on C-arm calibration accuracy were conducted and the mean value of mapping error was 0.41 mm. We designed an ACL reconstruction navigation system and carried out specimen experiments on 4 pairs of dry femur and tibia. The mean accuracy of navigation system was 0.85 mm, which is important to the tunnel positioning for ACL reconstruction.
- 29 December 2015
- Published by Elsevier in Chinese Journal of Mechanical Engineering
- Vol. 29 (1) , 11-20
Dynamic bending of bionic flexible body driven by pneumatic artificial muscles(PAMs) for spinning gait of quadruped robot
- 29 December 2015
- Published by Elsevier in Chinese Journal of Mechanical Engineering
- Vol. 29 (1) , 11-20
Dynamic bending of bionic flexible body driven by pneumatic artificial muscles(PAMs) for spinning gait of quadruped robot
- Open Access
Analysis and Experimental Kinematics of a Skid-Steering Wheeled Robot Based on a Laser Scanner Sensor
Skid-steering mobile robots are widely used because of their simple mechanism and robustness. However, due to the complex wheel-ground interactions and the kinematic constraints, it is a challenge to understand the kinematics and dynamics of such a robotic platform. In this paper, we develop an analysis and experimental kinematic scheme for a skid-steering wheeled vehicle based-on a laser scanner sensor. The kinematics model is established based on the boundedness of the instantaneous centers of rotation (ICR) of treads on the 2D motion plane. The kinematic parameters (the ICR coefficient , the path curvature variable and robot speed ), including the effect of vehicle dynamics, are introduced to describe the kinematics model. Then, an exact but costly dynamic model is used and the simulation of this model’s stationary response for the vehicle shows a qualitative relationship for the specified parameters and . Moreover, the parameters of the kinematic model are determined based-on a laser scanner localization experimental analysis method with a skid-steering robotic platform, Pioneer P3-AT. The relationship between the ICR coefficient and two physical factors is studied, i.e., the radius of the path curvature and the robot speed . An empirical function-based relationship between the ICR coefficient of the robot and the path parameters is derived. To validate the obtained results, it is empirically demonstrated that the proposed kinematics model significantly improves the dead-reckoning performance of this skid–steering robot.
Open AccessAnalysis and Experimental Kinematics of a Skid-Steering Wheeled Robot Based on a Laser Scanner Sensor
Skid-steering mobile robots are widely used because of their simple mechanism and robustness. However, due to the complex wheel-ground interactions and the kinematic constraints, it is a challenge to understand the kinematics and dynamics of such a robotic platform. In this paper, we develop an analysis and experimental kinematic scheme for a skid-steering wheeled vehicle based-on a laser scanner sensor. The kinematics model is established based on the boundedness of the instantaneous centers of rotation (ICR) of treads on the 2D motion plane. The kinematic parameters (the ICR coefficient , the path curvature variable and robot speed ), including the effect of vehicle dynamics, are introduced to describe the kinematics model. Then, an exact but costly dynamic model is used and the simulation of this model’s stationary response for the vehicle shows a qualitative relationship for the specified parameters and . Moreover, the parameters of the kinematic model are determined based-on a laser scanner localization experimental analysis method with a skid-steering robotic platform, Pioneer P3-AT. The relationship between the ICR coefficient and two physical factors is studied, i.e., the radius of the path curvature and the robot speed . An empirical function-based relationship between the ICR coefficient of the robot and the path parameters is derived. To validate the obtained results, it is empirically demonstrated that the proposed kinematics model significantly improves the dead-reckoning performance of this skid–steering robot.
- 1 January 2014
- Published by Elsevier in Chinese Journal of Mechanical Engineering
- Vol. 27 (1) , 138-145
Energy efficiency analysis of quadruped robot with trot gait and combined cycloid foot trajectory
Quadruped robots consume a lot of energy, which is one of the factors restricting their application. Energy efficiency is one of the key evaluating indicators for walking robots. The relationship between energy and elastic elements of walking robots have been studied, but different walking gait patterns and contact status have important influences on locomotion energy efficiency, and the energy efficiency considering the foot-end trajectory has not been reported. Therefore, the energy consumption and energy efficiency of quadruped robot with trot gait and combined cycloid foot trajectory are studied. The forward and inverse kinematics of quadruped robot is derived. The combined cycloid function is proposed to generate horizontal and vertical foot trajectory respectively, which can ensure the acceleration curve of the foot-end smoother and more successive, and reduce the contact force between feet and environment. Because of the variable topology mechanism characteristic of quadruped robot, the leg state is divided into three different phases which are swing phase, transition phase and stance phase during one trot gait cycle. The non-continuous variable constraint between feet and environment of quadruped robot is studied. The dynamic model of quadruped robot is derived considering the variable topology mechanism characteristic, the periodic contact and elastic elements of the robot. The total energy consumption of walking robot during one gait cycle is analyzed based on the dynamic model. The specific resistance is used to evaluate energy efficiency of quadruped robot. The calculation results show the relationships between specific resistance and gait parameters, which can be used to determine the reasonable gait parameters.
- 1 January 2014
- Published by Elsevier in Chinese Journal of Mechanical Engineering
- Vol. 27 (1) , 138-145
Energy efficiency analysis of quadruped robot with trot gait and combined cycloid foot trajectory
Quadruped robots consume a lot of energy, which is one of the factors restricting their application. Energy efficiency is one of the key evaluating indicators for walking robots. The relationship between energy and elastic elements of walking robots have been studied, but different walking gait patterns and contact status have important influences on locomotion energy efficiency, and the energy efficiency considering the foot-end trajectory has not been reported. Therefore, the energy consumption and energy efficiency of quadruped robot with trot gait and combined cycloid foot trajectory are studied. The forward and inverse kinematics of quadruped robot is derived. The combined cycloid function is proposed to generate horizontal and vertical foot trajectory respectively, which can ensure the acceleration curve of the foot-end smoother and more successive, and reduce the contact force between feet and environment. Because of the variable topology mechanism characteristic of quadruped robot, the leg state is divided into three different phases which are swing phase, transition phase and stance phase during one trot gait cycle. The non-continuous variable constraint between feet and environment of quadruped robot is studied. The dynamic model of quadruped robot is derived considering the variable topology mechanism characteristic, the periodic contact and elastic elements of the robot. The total energy consumption of walking robot during one gait cycle is analyzed based on the dynamic model. The specific resistance is used to evaluate energy efficiency of quadruped robot. The calculation results show the relationships between specific resistance and gait parameters, which can be used to determine the reasonable gait parameters.
- 17 July 2013
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 35 (4) , 469-478
A hopping-righting mechanism analysis and design of the mobile robot
- 17 July 2013
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 35 (4) , 469-478
A hopping-righting mechanism analysis and design of the mobile robot
- 24 June 2013
- Published by Wiley in Journal of Mechanisms and Robotics
- Vol. 5 (3) , 034503
On Kinematic Mechanism of a Two-Wheel Skateboard: The Essboard
In this paper, we investigate the kinematic mechanism and path planning of a two-caster nonholonomic vehicle (the Essboard) which is a recent variant of skateboards. Different from the most studied Snakeboard, the Essboard consists of a torsion bar and two platforms, each of which contains a pedal and a caster. We study the relationship between the tilt angle of the pedal and the wheel direction of the caster. This relationship clarifies how to control the wheel direction by adjusting the tilt angle. Furthermore, the rotational radius of the Essboard is derived for a given pair of tilt angles of both pedals. The rotational radius of the Essboard is much different to that of other skateboards. Two experiments are conducted to verify the results. These results clarify the kinematic mechanism and lay a solid foundation for further investigation of the Essboard.
- 24 June 2013
- Published by Wiley in Journal of Mechanisms and Robotics
- Vol. 5 (3) , 034503
On Kinematic Mechanism of a Two-Wheel Skateboard: The Essboard
In this paper, we investigate the kinematic mechanism and path planning of a two-caster nonholonomic vehicle (the Essboard) which is a recent variant of skateboards. Different from the most studied Snakeboard, the Essboard consists of a torsion bar and two platforms, each of which contains a pedal and a caster. We study the relationship between the tilt angle of the pedal and the wheel direction of the caster. This relationship clarifies how to control the wheel direction by adjusting the tilt angle. Furthermore, the rotational radius of the Essboard is derived for a given pair of tilt angles of both pedals. The rotational radius of the Essboard is much different to that of other skateboards. Two experiments are conducted to verify the results. These results clarify the kinematic mechanism and lay a solid foundation for further investigation of the Essboard.
- 18 May 2013
- Published by Elsevier in Chinese Journal of Mechanical Engineering
- Vol. 26 (3) , 547-554
Three-dimensional tool radius compensation for multi-axis peripheral milling
Few function about 3D tool radius compensation is applied to generating executable motion control commands in the existing computer numerical control (CNC) systems. Once the tool radius is changed, especially in the case of tool size changing with tool wear in machining, a new NC program has to be recreated. A generic 3D tool radius compensation method for multi-axis peripheral milling in CNC systems is presented. The offset path is calculated by offsetting the tool path along the direction of the offset vector with a given distance. The offset vector is perpendicular to both the tangent vector of the tool path and the orientation vector of the tool axis relative to the workpiece. The orientation vector equations of the tool axis relative to the workpiece are obtained through homogeneous coordinate transformation matrix and forward kinematics of generalized kinematics model of multi-axis machine tools. To avoid cutting into the corner formed by the two adjacent tool paths, the coordinates of offset path at the intersection point have been calculated according to the transition type that is determined by the angle between the two tool path tangent vectors at the corner. Through the verification by the solid cutting simulation software VERICUT® with different tool radiuses on a table-tilting type five-axis machine tool, and by the real machining experiment of machining a soup spoon on a five-axis machine tool with the developed CNC system, the effectiveness of the proposed 3D tool radius compensation method is confirmed. The proposed compensation method can be suitable for all kinds of three- to five-axis machine tools as a general form.
- 18 May 2013
- Published by Elsevier in Chinese Journal of Mechanical Engineering
- Vol. 26 (3) , 547-554
Three-dimensional tool radius compensation for multi-axis peripheral milling
Few function about 3D tool radius compensation is applied to generating executable motion control commands in the existing computer numerical control (CNC) systems. Once the tool radius is changed, especially in the case of tool size changing with tool wear in machining, a new NC program has to be recreated. A generic 3D tool radius compensation method for multi-axis peripheral milling in CNC systems is presented. The offset path is calculated by offsetting the tool path along the direction of the offset vector with a given distance. The offset vector is perpendicular to both the tangent vector of the tool path and the orientation vector of the tool axis relative to the workpiece. The orientation vector equations of the tool axis relative to the workpiece are obtained through homogeneous coordinate transformation matrix and forward kinematics of generalized kinematics model of multi-axis machine tools. To avoid cutting into the corner formed by the two adjacent tool paths, the coordinates of offset path at the intersection point have been calculated according to the transition type that is determined by the angle between the two tool path tangent vectors at the corner. Through the verification by the solid cutting simulation software VERICUT® with different tool radiuses on a table-tilting type five-axis machine tool, and by the real machining experiment of machining a soup spoon on a five-axis machine tool with the developed CNC system, the effectiveness of the proposed 3D tool radius compensation method is confirmed. The proposed compensation method can be suitable for all kinds of three- to five-axis machine tools as a general form.