Benjamin Giron-Palomares
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Benjamin Giron-Palomares has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Abel Hernandez-Guerrero
University of Guanajuato
2 shared publications - Bladimir Ramos-Alvarado
The Pennsylvania State University
1 shared publication Hai Jie Yang
Engineering Training Center, Anyang Institute of Technology, Anyang 455000, China
1 shared publication- Jinan Gu
School of Mechanical Engineering, Jiangsu University, Zhenjiang, China
1 shared publication - Ricardo Romero-Méndez
Facultad de Ingeniería, Universidad Autónoma de San Luis Potosí, San Luis Potosí, Mexico
1 shared publication - Rong Zou
School of Mechanical Engineering, Jiangsu University, Zhenjiang 212000, China
1 shared publication
Latest Publications
- 23 March 2021
- Published by Wiley in Journal of Heat Transfer
- Vol. 143 (5)
Experimental Characterization of an Active Infrared Thermography Heat Source
Accurate knowledge of the heat flux characteristics provided by optical heat sources of long heating time nondestructive infrared thermography techniques is essential to determine the adequate application of such techniques; however, detailed characterizations are scarce. Therefore, a thermal and statistical characterization of a halogen lamp was developed. A highly repeatable experimental procedure was used to characterize the heat flux generated at an ideal inspection sample top surface. The characteristics studied were: lamp distance, bulb color, lamp orientation, heat quality, and heating time. The heat flux was determined by using the readings of temperature and heat flux from the sample back, and a finite differences lumped capacitance thermal model. Detailed studies using three sensors determined that the heat flux was nonuniform (13% maximum variation). Therefore, a full quantitative characterization of the lamp was developed by using the average of such sensor readings, determining that: this halogen lamp can provide consistent top heat fluxes (although not uniformly distributed) adequate for nondestructive testing infrared thermography, the lamp distance and bulb color affected the amount of heat provided as well as the heat flux uniformity, and lamp orientation did not affect the mean top heat fluxes. This research approach can be used to determine an approximation of the lamp time-averaged heat fluxes for any material with similar top surface optical characteristics. Moreover, the technical data provided are useful to determine the adequacy of heating time, lamp distance, lamp orientation, and bulb color for long heating time nondestructive testing infrared thermography.
- 23 March 2021
- Published by Wiley in Journal of Heat Transfer
- Vol. 143 (5)
Experimental Characterization of an Active Infrared Thermography Heat Source
Accurate knowledge of the heat flux characteristics provided by optical heat sources of long heating time nondestructive infrared thermography techniques is essential to determine the adequate application of such techniques; however, detailed characterizations are scarce. Therefore, a thermal and statistical characterization of a halogen lamp was developed. A highly repeatable experimental procedure was used to characterize the heat flux generated at an ideal inspection sample top surface. The characteristics studied were: lamp distance, bulb color, lamp orientation, heat quality, and heating time. The heat flux was determined by using the readings of temperature and heat flux from the sample back, and a finite differences lumped capacitance thermal model. Detailed studies using three sensors determined that the heat flux was nonuniform (13% maximum variation). Therefore, a full quantitative characterization of the lamp was developed by using the average of such sensor readings, determining that: this halogen lamp can provide consistent top heat fluxes (although not uniformly distributed) adequate for nondestructive testing infrared thermography, the lamp distance and bulb color affected the amount of heat provided as well as the heat flux uniformity, and lamp orientation did not affect the mean top heat fluxes. This research approach can be used to determine an approximation of the lamp time-averaged heat fluxes for any material with similar top surface optical characteristics. Moreover, the technical data provided are useful to determine the adequacy of heating time, lamp distance, lamp orientation, and bulb color for long heating time nondestructive testing infrared thermography.
- Open Access
- 29 April 2019
- Published by MDPI AG in Electronics
- Vol. 8 (5) , 481
Surface Defects Recognition of Wheel Hub Based on Improved Faster R-CNN
Machine vision is one of the key technologies used to perform intelligent manufacturing. In order to improve the recognition rate of multi-class defects in wheel hubs, an improved Faster R-CNN method was proposed. A data set for wheel hub defects was built. This data set consisted of four types of defects in 2,412 1080 × 1440 pixels images. Faster R-CNN was modified, trained, verified and tested based on this database. The recognition rate for this proposed method was excellent. The proposed method was compared with the popular R-CNN and YOLOv3 methods showing simpler, faster, and more accurate defect detection, which demonstrates the superiority of the improved Faster R-CNN for wheel hub defects.
- 29 April 2019
- Published by MDPI AG in Electronics
- Vol. 8 (5) , 481
Open AccessSurface Defects Recognition of Wheel Hub Based on Improved Faster R-CNN
Machine vision is one of the key technologies used to perform intelligent manufacturing. In order to improve the recognition rate of multi-class defects in wheel hubs, an improved Faster R-CNN method was proposed. A data set for wheel hub defects was built. This data set consisted of four types of defects in 2,412 1080 × 1440 pixels images. Faster R-CNN was modified, trained, verified and tested based on this database. The recognition rate for this proposed method was excellent. The proposed method was compared with the popular R-CNN and YOLOv3 methods showing simpler, faster, and more accurate defect detection, which demonstrates the superiority of the improved Faster R-CNN for wheel hub defects.
- 12 May 2014
- Published by ASME International in Journal of Electronic Packaging
- Vol. 136 (3) , 031008
Evaluation of Nonintrusive Active Infrared Thermography Technique to Detect Hidden Solder Ball Defects on Plastic Ball Grid Array Components
It is essential for electronics reliability to develop effective methodologies to detect hidden solder joint defects. Active infrared thermography is an alternative to X-ray detection methodologies. The limits of active infrared thermography to detect solder ball defects on plastic ball grid arrays (PBGA) components (missing, open, cracked, and head on pillow defects) are investigated here. A FEM was used to simulate the thermal phenomena during the infrared thermography inspection of a PBGA component. The FEM was proven to be temporal and spatial grids size independent. The average temperature difference (ΔT) amid regions with and without defects was used as a detectability indicator. Defects detectability was found to decrease as the number of blocking objects increases. Missing solder balls were barely detected when blocked by the substrate and moulding compound with detectability numbers close to 1 °C. Head on pillow and cracked defects were impossible to detect with a maximum ΔT = 0.6 °C. Open solder balls were not detected below two objects with a maximum ΔT = 0.3 °C. These results clearly suggest that infrared thermography can be effectively used to detect hidden missing and open solder ball defects on PBGA components composed by a substrate and a die.
- 12 May 2014
- Published by ASME International in Journal of Electronic Packaging
- Vol. 136 (3) , 031008
Evaluation of Nonintrusive Active Infrared Thermography Technique to Detect Hidden Solder Ball Defects on Plastic Ball Grid Array Components
It is essential for electronics reliability to develop effective methodologies to detect hidden solder joint defects. Active infrared thermography is an alternative to X-ray detection methodologies. The limits of active infrared thermography to detect solder ball defects on plastic ball grid arrays (PBGA) components (missing, open, cracked, and head on pillow defects) are investigated here. A FEM was used to simulate the thermal phenomena during the infrared thermography inspection of a PBGA component. The FEM was proven to be temporal and spatial grids size independent. The average temperature difference (ΔT) amid regions with and without defects was used as a detectability indicator. Defects detectability was found to decrease as the number of blocking objects increases. Missing solder balls were barely detected when blocked by the substrate and moulding compound with detectability numbers close to 1 °C. Head on pillow and cracked defects were impossible to detect with a maximum ΔT = 0.6 °C. Open solder balls were not detected below two objects with a maximum ΔT = 0.3 °C. These results clearly suggest that infrared thermography can be effectively used to detect hidden missing and open solder ball defects on PBGA components composed by a substrate and a die.