Thomas Wüest
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Thomas Wüest has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Luible
Lucerne University of Applied Sciences and Arts
3 shared publications - Thiemo Fildhuth
Knippershelbig GmbH Tübinger Str. 12‐16 D‐70178 Stuttgart
2 shared publications Andreas Luible
Hochschule Luzern, Technik & Architektur, Technikumstrasse, Horw, Switzerland
1 shared publication- Chiara Bedon
Department of Engineering and Architecture, University of Trieste, Trieste, Italy
1 shared publication - Dániel Honfi
Monitoring and Analyses of Existing Structures, Ramboll, Copenhagen, Denmark
1 shared publication Fildhuth Thiemo
Lucerne University of Applied Sciences and Arts, Lucerne, Switzerland
1 shared publication
Latest Publications
- Open Access
- 28 July 2023
- Published by Springer Nature in Glass Structures & Engineering
- Vol. 8 (3) , 339-351
New Swiss technical specification SIA 2057 for glass structures and its post failure limit state concept
Until recently, designing and constructing with glass in Switzerland was not performed on a uniformly regulated basis due to the lack of a national standard for glass. Therefore, foreign regulations and codes were typically applied. However, this practice repeatedly caused problems. In August 2021, the Technical Specification SIA 2057 Glass Structures has been published to close this codification gap and to create a uniform design basis for the Swiss glass industry. A wide range of glass applications is covered, taking into account the latest findings from practice and science, such as use of shear transfer in laminated glass. The SIA 2057 follows the well-proven SIA principles of regulating only where necessary. Thus, a flexible application of the code is made possible, and innovation is encouraged. In addition to simple design methods, engineers are free to pursue alternative and innovative paths in glass design. The present article provides an overview of the SIA 2057 with focus on laminated safety glass design and post fracture limit state verification.
- 28 July 2023
- Published by Springer Nature in Glass Structures & Engineering
- Vol. 8 (3) , 339-351
Open AccessNew Swiss technical specification SIA 2057 for glass structures and its post failure limit state concept
Until recently, designing and constructing with glass in Switzerland was not performed on a uniformly regulated basis due to the lack of a national standard for glass. Therefore, foreign regulations and codes were typically applied. However, this practice repeatedly caused problems. In August 2021, the Technical Specification SIA 2057 Glass Structures has been published to close this codification gap and to create a uniform design basis for the Swiss glass industry. A wide range of glass applications is covered, taking into account the latest findings from practice and science, such as use of shear transfer in laminated glass. The SIA 2057 follows the well-proven SIA principles of regulating only where necessary. Thus, a flexible application of the code is made possible, and innovation is encouraged. In addition to simple design methods, engineers are free to pursue alternative and innovative paths in glass design. The present article provides an overview of the SIA 2057 with focus on laminated safety glass design and post fracture limit state verification.
- Open Access
- 7 October 2022
- Published by Springer Nature in Glass Structures & Engineering
- Vol. 7 (3) , 415-439
Development and behavior of a thin fitting connection for lamination with structural PVB
Intended for the construction of a double curved, frameless modular glass shell demonstrator, a stainless steel fitting connection with a trapezoidal, thin sheet laminated into the interstice of two-ply safety glass has been developed. For the bonding within the glass laminate, structural PVB interlayer is used. Various interlayer plies of different PVB types can be stacked depending on the necessary interstice thickness and the intended esthetical appearance. The fitting is designed to mainly transfer translational forces, but it also provides some bending stiffness via a crossbar supported against the glass edge. Various tests, including tension, shear and bending load application, have been performed at the Lucerne University of Applied Sciences and Arts (HSLU) to explore the structural behavior and the load bearing capacity of the fitting connection. In addition, parameter studies using finite element models were made to explore the influence of the fitting geometry, dimensions, interlayer properties and loading type on the structural behavior of this type of connection. These parameter studies and test results allow to identify further shape optimization and application possibilities of such thin, laminated fittings for load bearing glass structures.
- 7 October 2022
- Published by Springer Nature in Glass Structures & Engineering
- Vol. 7 (3) , 415-439
Open AccessDevelopment and behavior of a thin fitting connection for lamination with structural PVB
Intended for the construction of a double curved, frameless modular glass shell demonstrator, a stainless steel fitting connection with a trapezoidal, thin sheet laminated into the interstice of two-ply safety glass has been developed. For the bonding within the glass laminate, structural PVB interlayer is used. Various interlayer plies of different PVB types can be stacked depending on the necessary interstice thickness and the intended esthetical appearance. The fitting is designed to mainly transfer translational forces, but it also provides some bending stiffness via a crossbar supported against the glass edge. Various tests, including tension, shear and bending load application, have been performed at the Lucerne University of Applied Sciences and Arts (HSLU) to explore the structural behavior and the load bearing capacity of the fitting connection. In addition, parameter studies using finite element models were made to explore the influence of the fitting geometry, dimensions, interlayer properties and loading type on the structural behavior of this type of connection. These parameter studies and test results allow to identify further shape optimization and application possibilities of such thin, laminated fittings for load bearing glass structures.
- Open Access
- 30 June 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (13) , 5281
An Innovative Façade Element with Controlled Solar-Thermal Collector and Storage
A novel façade element is presented that forms a symbiosis between an enhanced box-type window, a closed cavity façade, and a Trombe wall. This hybrid, transparent-opaque façade element features an absorbing water tank, that is installed behind a controlled shading device toward the cavity of a non-ventilated Double Skin Façade in the parapet section. To evaluate the potential impact on building performance, a transient simulation model is developed in Modelica and calibrated by comparison with measurements on a prototype. The effect of the absorbing thermal storage on heat transfers under solar radiation is analyzed in comparison to (i) conditions excluding solar radiation and (ii) an empty tank. An evaluation for four European cities demonstrates that the annual heating demand can be reduced by more than 4.2% and cooling demand by at least 6.6% compared to a façade without thermal storage. The effect is explained not only by the increased thermal mass, but also by the effective modulation of solar gains by the controlled absorbing storage. The dampening of heat flow fluctuations and the control of solar gains is a promising means to reduce the installed power of HVAC (heating/ventilating/air conditioning) installations.
- 30 June 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (13) , 5281
Open AccessAn Innovative Façade Element with Controlled Solar-Thermal Collector and Storage
A novel façade element is presented that forms a symbiosis between an enhanced box-type window, a closed cavity façade, and a Trombe wall. This hybrid, transparent-opaque façade element features an absorbing water tank, that is installed behind a controlled shading device toward the cavity of a non-ventilated Double Skin Façade in the parapet section. To evaluate the potential impact on building performance, a transient simulation model is developed in Modelica and calibrated by comparison with measurements on a prototype. The effect of the absorbing thermal storage on heat transfers under solar radiation is analyzed in comparison to (i) conditions excluding solar radiation and (ii) an empty tank. An evaluation for four European cities demonstrates that the annual heating demand can be reduced by more than 4.2% and cooling demand by at least 6.6% compared to a façade without thermal storage. The effect is explained not only by the increased thermal mass, but also by the effective modulation of solar gains by the controlled absorbing storage. The dampening of heat flow fluctuations and the control of solar gains is a promising means to reduce the installed power of HVAC (heating/ventilating/air conditioning) installations.
- Open Access
Outdoor Test Cell Modelling with Modelica
The experimental setup implements a simplified PASSYS test cell construction, which is combined with a detailed simulation to reduce measurement effort. To analyze the cell’s dynamic behavior, the test cell was closely monitored with thermal sensors, and different static and dynamic heating modes were applied during a three-week calibration period. Co-heating tests were performed for steady-state measurements and cyclic heating periods account for the transient behavior of the test cell. The cells response was compared to the results of transient simulations with the software packet Modelica. The equation based Modelica framework allowed a detailed transient thermal simulation of the test cell’s dynamic to be set up that shows close agreement with the measurements. In addition, the flexibility of Modelica allowed unforeseen events affecting the experimental setup to be replicated, thereby ensuring an uninterrupted heat flow history of all surfaces. More than 96% of the predicted air temperatures (1 min resolution) match the experimental values within an error band of ±1.5 K, and 90% of all predictions are within ±1.0 K.
Open AccessOutdoor Test Cell Modelling with Modelica
The experimental setup implements a simplified PASSYS test cell construction, which is combined with a detailed simulation to reduce measurement effort. To analyze the cell’s dynamic behavior, the test cell was closely monitored with thermal sensors, and different static and dynamic heating modes were applied during a three-week calibration period. Co-heating tests were performed for steady-state measurements and cyclic heating periods account for the transient behavior of the test cell. The cells response was compared to the results of transient simulations with the software packet Modelica. The equation based Modelica framework allowed a detailed transient thermal simulation of the test cell’s dynamic to be set up that shows close agreement with the measurements. In addition, the flexibility of Modelica allowed unforeseen events affecting the experimental setup to be replicated, thereby ensuring an uninterrupted heat flow history of all surfaces. More than 96% of the predicted air temperatures (1 min resolution) match the experimental values within an error band of ±1.5 K, and 90% of all predictions are within ±1.0 K.
- 1 September 2019
- Published by Elsevier in Journal of Building Engineering
- Vol. 25, 100721
Structural characterisation of adaptive facades in Europe – Part I: Insight on classification rules, performance metrics and design methods
- 1 September 2019
- Published by Elsevier in Journal of Building Engineering
- Vol. 25, 100721
Structural characterisation of adaptive facades in Europe – Part I: Insight on classification rules, performance metrics and design methods
- Open Access
- 8 July 2017
- Published by Stichting OpenAccess Foundation in Journal of Facade Design and Engineering
- Vol. 4 (3-4) , 91-113
Increased thermal induced climatic load in insulated glass units
- 8 July 2017
- Published by Stichting OpenAccess Foundation in Journal of Facade Design and Engineering
- Vol. 4 (3-4) , 91-113
Open AccessIncreased thermal induced climatic load in insulated glass units