Daniele E. Schiavazzi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daniele E. Schiavazzi has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
Alison L. Marsden
Department of Pediatrics (Cardiology), Stanford School of Medicine, Stanford, CA, USA; Institute for Computational and Mathematical Engineering, Stanford University, Stanford, CA, USA; Department of Bioengineering, Stanford University, Stanford, CA, USA
7 shared publications- Alison Lesley Marsden
Institute for Computational and Mathematical Engineering, Stanford University, Stanford, USA
5 shared publications Gianluca Geraci
5 shared publications- Andrea Zanoni
Centro di Ricerca Matematica Ennio De Giorgi, Scuola Normale Superiore, Pisa, Italy
4 shared publications Jakob Richter
Department of Pediatrics, Stanford University
3 shared publicationsJeffrey A. Feinstein
Department of Pediatrics (Cardiology) Stanford University Stanford California USA
3 shared publications
Latest Publications
- 22 July 2026
- Published by Society for Industrial & Applied Mathematics (SIAM) in SIAM Journal on Scientific Computing
- Vol. 48 (4) , C832-C861
Enabling Stratified Sampling in High Dimensions via Nonlinear Dimensionality Reduction
We consider the problem of propagating the uncertainty from a possibly large number of random inputs through a computationally expensive model. Stratified sampling is a well-known variance reduction strategy, but its application, thus far, has focused on models with a limited number of inputs due to the challenges of creating uniform partitions in high dimensions. To overcome these challenges, we propose a simple methodology for constructing an effective stratification of the input domain that is adapted to the model response. Our approach leverages neural active manifolds, a recently introduced nonlinear dimensionality reduction technique based on neural networks that identifies a one-dimensional manifold capturing most of the model variability. The resulting one-dimensional latent space is mapped to the unit interval, where stratification is performed with respect to the uniform distribution. The corresponding strata in the original input space are then recovered through the neural active manifold, generating partitions that tend to follow the level sets of the model. We show that our approach is effective in high dimensions and can be used to further reduce the variance of multifidelity Monte Carlo estimators.
- 22 July 2026
- Published by Society for Industrial & Applied Mathematics (SIAM) in SIAM Journal on Scientific Computing
- Vol. 48 (4) , C832-C861
Enabling Stratified Sampling in High Dimensions via Nonlinear Dimensionality Reduction
We consider the problem of propagating the uncertainty from a possibly large number of random inputs through a computationally expensive model. Stratified sampling is a well-known variance reduction strategy, but its application, thus far, has focused on models with a limited number of inputs due to the challenges of creating uniform partitions in high dimensions. To overcome these challenges, we propose a simple methodology for constructing an effective stratification of the input domain that is adapted to the model response. Our approach leverages neural active manifolds, a recently introduced nonlinear dimensionality reduction technique based on neural networks that identifies a one-dimensional manifold capturing most of the model variability. The resulting one-dimensional latent space is mapped to the unit interval, where stratification is performed with respect to the uniform distribution. The corresponding strata in the original input space are then recovered through the neural active manifold, generating partitions that tend to follow the level sets of the model. We show that our approach is effective in high dimensions and can be used to further reduce the variance of multifidelity Monte Carlo estimators.
- Open Access
- 1 July 2026
- Published by Elsevier in Journal of Computational Physics
- Vol. 565
Assessing the performance of correlation-based multi-fidelity neural emulators
- 1 July 2026
- Published by Elsevier in Journal of Computational Physics
- Vol. 565
Open AccessAssessing the performance of correlation-based multi-fidelity neural emulators
- 25 February 2026
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 205, 111565
On the accuracy of implicit neural representations for cardiovascular anatomies and hemodynamic fields
- 25 February 2026
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 205, 111565
On the accuracy of implicit neural representations for cardiovascular anatomies and hemodynamic fields
- 16 December 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 200, 111389
On the performance of multi-fidelity and reduced-dimensional neural emulators for inference of physiological boundary conditions
- 16 December 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 200, 111389
On the performance of multi-fidelity and reduced-dimensional neural emulators for inference of physiological boundary conditions
- Open Access
Assessing the performance of correlation-based multi-fidelity neural emulators
Outer loop tasks such as optimization, uncertainty quantification or inference can easily become intractable when the underlying high-fidelity model is computationally expensive. Similarly, data-driven architectures typically require large datasets to perform predictive tasks with sufficient accuracy. A possible approach to mitigate these challenges is the development of multi-fidelity emulators, leveraging potentially biased, inexpensive low-fidelity information while correcting and refining predictions using scarce, accurate high-fidelity data. This study investigates the performance of multi-fidelity neural emulators, neural networks designed to learn the input-to-output mapping by integrating limited high-fidelity data with abundant low-fidelity model solutions. We investigate the performance of such emulators for low and high-dimensional functions, with oscillatory character, in the presence of discontinuities, for collections of models with equal and dissimilar parametrization, and for a possibly large number of potentially corrupted low-fidelity sources. In doing so, we consider a large number of architectural, hyperparameter, and dataset configurations including networks with a different amount of spectral bias (Multi-Layered Perceptron, Siren and Kolmogorov Arnold Network), various mechanisms for coordinate encoding, exact or learnable low-fidelity information, and for varying training dataset size. We further analyze the added value of the multi-fidelity approach by conducting equivalent single-fidelity tests for each case, quantifying the performance gains achieved through fusing multiple sources of information.
Open AccessAssessing the performance of correlation-based multi-fidelity neural emulators
Outer loop tasks such as optimization, uncertainty quantification or inference can easily become intractable when the underlying high-fidelity model is computationally expensive. Similarly, data-driven architectures typically require large datasets to perform predictive tasks with sufficient accuracy. A possible approach to mitigate these challenges is the development of multi-fidelity emulators, leveraging potentially biased, inexpensive low-fidelity information while correcting and refining predictions using scarce, accurate high-fidelity data. This study investigates the performance of multi-fidelity neural emulators, neural networks designed to learn the input-to-output mapping by integrating limited high-fidelity data with abundant low-fidelity model solutions. We investigate the performance of such emulators for low and high-dimensional functions, with oscillatory character, in the presence of discontinuities, for collections of models with equal and dissimilar parametrization, and for a possibly large number of potentially corrupted low-fidelity sources. In doing so, we consider a large number of architectural, hyperparameter, and dataset configurations including networks with a different amount of spectral bias (Multi-Layered Perceptron, Siren and Kolmogorov Arnold Network), various mechanisms for coordinate encoding, exact or learnable low-fidelity information, and for varying training dataset size. We further analyze the added value of the multi-fidelity approach by conducting equivalent single-fidelity tests for each case, quantifying the performance gains achieved through fusing multiple sources of information.
- Open Access
- 19 July 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 271, 108951
Personalized and uncertainty-aware coronary hemodynamics simulations: From Bayesian estimation to improved multi-fidelity uncertainty quantification
- 19 July 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 271, 108951
Open AccessPersonalized and uncertainty-aware coronary hemodynamics simulations: From Bayesian estimation to improved multi-fidelity uncertainty quantification
- Open Access
- 2 April 2025
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 383 (2293) , 20240215
InVAErt networks for amortized inference and identifiability analysis of lumped‐parameter haemodynamic models
Estimation of cardiovascular model parameters from electronic health records (EHRs) poses a significant challenge primarily due to lack of identifiability. Structural non-identifiability arises when a manifold in the space of parameters is mapped to a common output, while practical non-identifiability can result due to limited data, model misspecification or noise corruption. To address the resulting ill-posed inverse problem, optimization-based or Bayesian inference approaches typically use regularization, thereby limiting the possibility of discovering multiple solutions. In this study, we use inVAErt networks, a neural network-based, data-driven framework for enhanced digital twin analysis of stiff dynamical systems. We demonstrate the flexibility and effectiveness of inVAErt networks in the context of physiological inversion of a six-compartment lumped‐parameter haemodynamic model from synthetic data to real data with missing components. This article is part of the theme issue ‘Uncertainty quantification for healthcare and biological systems (Part 2)’.
- 2 April 2025
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 383 (2293) , 20240215
Open AccessInVAErt networks for amortized inference and identifiability analysis of lumped‐parameter haemodynamic models
Estimation of cardiovascular model parameters from electronic health records (EHRs) poses a significant challenge primarily due to lack of identifiability. Structural non-identifiability arises when a manifold in the space of parameters is mapped to a common output, while practical non-identifiability can result due to limited data, model misspecification or noise corruption. To address the resulting ill-posed inverse problem, optimization-based or Bayesian inference approaches typically use regularization, thereby limiting the possibility of discovering multiple solutions. In this study, we use inVAErt networks, a neural network-based, data-driven framework for enhanced digital twin analysis of stiff dynamical systems. We demonstrate the flexibility and effectiveness of inVAErt networks in the context of physiological inversion of a six-compartment lumped‐parameter haemodynamic model from synthetic data to real data with missing components. This article is part of the theme issue ‘Uncertainty quantification for healthcare and biological systems (Part 2)’.
- 13 March 2025
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 383 (2292) , 20240223
Bayesian Windkessel calibration using optimized zero-dimensional surrogate models
Bayesian boundary condition (BC) calibration approaches from clinical measurements have successfully quantified inherent uncertainties in cardiovascular fluid dynamics simulations. However, estimating the posterior distribution for all BC parameters in three-dimensional (3D) simulations has been unattainable due to infeasible computational demand. We propose an efficient method to identify Windkessel parameter posteriors: We only evaluate the 3D model once for an initial choice of BCs and use the result to create a highly accurate zero-dimensional (0D) surrogate. We then perform Sequential Monte Carlo (SMC) using the optimized 0D model to derive the high-dimensional Windkessel BC posterior distribution. Optimizing 0D models to match 3D data a priori lowered their median approximation error by nearly one order of magnitude in 72 publicly available vascular models. The optimized 0D models generalized well to a wide range of BCs. Using SMC, we evaluated the high-dimensional Windkessel parameter posterior for different measured signal-to-noise ratios in a vascular model, which we validated against a 3D posterior. The minimal computational demand of our method using a single 3D simulation, combined with the open-source nature of all software and data used in this work, will increase access and efficiency of Bayesian Windkessel calibration in cardiovascular fluid dynamics simulations. This article is part of the theme issue ‘Uncertainty quantification for healthcare and biological systems (Part 1)’.
- 13 March 2025
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 383 (2292) , 20240223
Bayesian Windkessel calibration using optimized zero-dimensional surrogate models
Bayesian boundary condition (BC) calibration approaches from clinical measurements have successfully quantified inherent uncertainties in cardiovascular fluid dynamics simulations. However, estimating the posterior distribution for all BC parameters in three-dimensional (3D) simulations has been unattainable due to infeasible computational demand. We propose an efficient method to identify Windkessel parameter posteriors: We only evaluate the 3D model once for an initial choice of BCs and use the result to create a highly accurate zero-dimensional (0D) surrogate. We then perform Sequential Monte Carlo (SMC) using the optimized 0D model to derive the high-dimensional Windkessel BC posterior distribution. Optimizing 0D models to match 3D data a priori lowered their median approximation error by nearly one order of magnitude in 72 publicly available vascular models. The optimized 0D models generalized well to a wide range of BCs. Using SMC, we evaluated the high-dimensional Windkessel parameter posterior for different measured signal-to-noise ratios in a vascular model, which we validated against a 3D posterior. The minimal computational demand of our method using a single 3D simulation, combined with the open-source nature of all software and data used in this work, will increase access and efficiency of Bayesian Windkessel calibration in cardiovascular fluid dynamics simulations. This article is part of the theme issue ‘Uncertainty quantification for healthcare and biological systems (Part 1)’.
- Open Access
- 13 March 2025
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 383 (2292) , 20240221
Quantification of total uncertainty in the physics-informed reconstruction of CVSim-6 physiology
When predicting physical phenomena through simulation, quantification of the total uncertainty due to multiple sources is as crucial as making sure the underlying numerical model is accurate. Possible sources include irreducible aleatoric uncertainty due to noise in the data, epistemic uncertainty induced by insufficient data or inadequate parameterization and model-form uncertainty related to the use of misspecified model equations. In addition, recently proposed approaches provide flexible ways to combine information from data with full or partial satisfaction of equations that typically encode physical principles. Physics-based regularization interacts in non-trivial ways with aleatoric, epistemic and model-form uncertainty and their combination, and a better understanding of this interaction is needed to improve the predictive performance of physics-informed digital twins that operate under real conditions. To better understand this interaction, with a specific focus on biological and physiological models, this study investigates the decomposition of total uncertainty in the estimation of states and parameters of a differential system simulated with MC X-TFC, a new physics-informed approach for uncertainty quantification based on random projections and Monte Carlo sampling. After an introductory comparison between approaches for physics-informed estimation, MC X-TFC is applied to a six-compartment stiff ODE system, the CVSim-6 model, developed in the context of human physiology. The system is first analysed by progressively removing data while estimating an increasing number of parameters, and subsequently by investigating total uncertainty under model-form misspecification of nonlinear resistance in the pulmonary compartment. In particular, we focus on the interaction between the formulation of the discrepancy term and quantification of model-form uncertainty, and show how additional physics can help in the estimation process. The method demonstrates robustness and efficiency in estimating unknown states and parameters, even with limited, sparse and noisy data. It also offers great flexibility in integrating data with physics for improved estimation, even in cases of model misspecification. This article is part of the theme issue ‘Uncertainty quantification for healthcare and biological systems (Part 1)’.
- 13 March 2025
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 383 (2292) , 20240221
Open AccessQuantification of total uncertainty in the physics-informed reconstruction of CVSim-6 physiology
When predicting physical phenomena through simulation, quantification of the total uncertainty due to multiple sources is as crucial as making sure the underlying numerical model is accurate. Possible sources include irreducible aleatoric uncertainty due to noise in the data, epistemic uncertainty induced by insufficient data or inadequate parameterization and model-form uncertainty related to the use of misspecified model equations. In addition, recently proposed approaches provide flexible ways to combine information from data with full or partial satisfaction of equations that typically encode physical principles. Physics-based regularization interacts in non-trivial ways with aleatoric, epistemic and model-form uncertainty and their combination, and a better understanding of this interaction is needed to improve the predictive performance of physics-informed digital twins that operate under real conditions. To better understand this interaction, with a specific focus on biological and physiological models, this study investigates the decomposition of total uncertainty in the estimation of states and parameters of a differential system simulated with MC X-TFC, a new physics-informed approach for uncertainty quantification based on random projections and Monte Carlo sampling. After an introductory comparison between approaches for physics-informed estimation, MC X-TFC is applied to a six-compartment stiff ODE system, the CVSim-6 model, developed in the context of human physiology. The system is first analysed by progressively removing data while estimating an increasing number of parameters, and subsequently by investigating total uncertainty under model-form misspecification of nonlinear resistance in the pulmonary compartment. In particular, we focus on the interaction between the formulation of the discrepancy term and quantification of model-form uncertainty, and show how additional physics can help in the estimation process. The method demonstrates robustness and efficiency in estimating unknown states and parameters, even with limited, sparse and noisy data. It also offers great flexibility in integrating data with physics for improved estimation, even in cases of model misspecification. This article is part of the theme issue ‘Uncertainty quantification for healthcare and biological systems (Part 1)’.
- Open Access
Quantification of total uncertainty in the physics-informed reconstruction of CVSim-6 physiology
When predicting physical phenomena through simulation, quantification of the total uncertainty due to multiple sources is as crucial as making sure the underlying numerical model is accurate. Possible sources include irreducible aleatoric uncertainty due to noise in the data, epistemic uncertainty induced by insufficient data or inadequate parameterization, and model-form uncertainty related to the use of misspecified model equations. Physics-based regularization interacts in nontrivial ways with aleatoric, epistemic and model-form uncertainty and their combination, and a better understanding of this interaction is needed to improve the predictive performance of physics-informed digital twins that operate under real conditions. With a specific focus on biological and physiological models, this study investigates the decomposition of total uncertainty in the estimation of states and parameters of a differential system simulated with MC X-TFC, a new physics-informed approach for uncertainty quantification based on random projections and Monte-Carlo sampling. MC X-TFC is applied to a six-compartment stiff ODE system, the CVSim-6 model, developed in the context of human physiology. The system is analyzed by progressively removing data while estimating an increasing number of parameters and by investigating total uncertainty under model-form misspecification of non-linear resistance in the pulmonary compartment. In particular, we focus on the interaction between the formulation of the discrepancy term and quantification of model-form uncertainty, and show how additional physics can help in the estimation process. The method demonstrates robustness and efficiency in estimating unknown states and parameters, even with limited, sparse, and noisy data. It also offers great flexibility in integrating data with physics for improved estimation, even in cases of model misspecification.
Open AccessQuantification of total uncertainty in the physics-informed reconstruction of CVSim-6 physiology
When predicting physical phenomena through simulation, quantification of the total uncertainty due to multiple sources is as crucial as making sure the underlying numerical model is accurate. Possible sources include irreducible aleatoric uncertainty due to noise in the data, epistemic uncertainty induced by insufficient data or inadequate parameterization, and model-form uncertainty related to the use of misspecified model equations. Physics-based regularization interacts in nontrivial ways with aleatoric, epistemic and model-form uncertainty and their combination, and a better understanding of this interaction is needed to improve the predictive performance of physics-informed digital twins that operate under real conditions. With a specific focus on biological and physiological models, this study investigates the decomposition of total uncertainty in the estimation of states and parameters of a differential system simulated with MC X-TFC, a new physics-informed approach for uncertainty quantification based on random projections and Monte-Carlo sampling. MC X-TFC is applied to a six-compartment stiff ODE system, the CVSim-6 model, developed in the context of human physiology. The system is analyzed by progressively removing data while estimating an increasing number of parameters and by investigating total uncertainty under model-form misspecification of non-linear resistance in the pulmonary compartment. In particular, we focus on the interaction between the formulation of the discrepancy term and quantification of model-form uncertainty, and show how additional physics can help in the estimation process. The method demonstrates robustness and efficiency in estimating unknown states and parameters, even with limited, sparse, and noisy data. It also offers great flexibility in integrating data with physics for improved estimation, even in cases of model misspecification.