A. H. T. Eranga De Silva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
A. H. T. Eranga De Silva has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Atsushi Mitani
Sapporo City Univ, Sch Design, Minami Ku, 1 Geijutsunomori, Sapporo, Hokkaido 0050864, Japan
3 shared publications - W. H. P. Sampath
Department of Mechanical Engineering, University of Moratuwa, Katubedda, Sri Lanka
3 shared publications - Lakshitha Sameera
Department of Mechanical Engineering, University of Moratuwa, Katubedda 10400, Sri Lanka
2 shared publications - Ranjith Amarasinghe
Department of Mechanical Engineering, University of Moratuwa, Moratuwa, Sri Lanka
2 shared publications - Buddhi Herath
Australian Research Council (ARC) Training Centre for Multiscale 3D Imaging, Modelling, and Manufacturing (M3D Innovation), Queensland University of Technology, Brisbane, QLD 4000, Australia
1 shared publication - Dimuthu Wijethunge
School of Engineering, University of Southern Queensland, 37 Sinnathamby Blvd, Springfield Central, QLD 4300, Australia
1 shared publication
Latest Publications
- Open Access
UAV-UGV Collaborative Localisation with Minimum Sensing
This paper presents a novel methodology to localise Unmanned Ground Vehicles (UGVs) using Unmanned Aerial Vehicles (UAVs). The UGVs are assumed to be operating in a Global Navigation Satellite System (GNSS)-denied environment. The localisation of the ground vehicles is achieved using UAVs that have full access to the GNSS. The UAVs use range sensors to localise the UGV. One of the major requirements is to use the minimum number of UAVs, which is two UAVs in this paper. Using only two UAVs leads to a significant complication that results an estimation unobservability under certain circumstances. As a solution to the unobservability problem, the main contribution of this paper is to present a methodology to treat the unobservability problem. A Constrained Extended Kalman Filter (CEKF)-based solution, which uses novel kinematics and heuristics-based constraints, is presented. The proposed methodology has been assessed based on the stochastic observability using the Posterior Cramér–Rao Bound (PCRB), and the results demonstrate the successful operation of the proposed localisation method.
Open AccessUAV-UGV Collaborative Localisation with Minimum Sensing
This paper presents a novel methodology to localise Unmanned Ground Vehicles (UGVs) using Unmanned Aerial Vehicles (UAVs). The UGVs are assumed to be operating in a Global Navigation Satellite System (GNSS)-denied environment. The localisation of the ground vehicles is achieved using UAVs that have full access to the GNSS. The UAVs use range sensors to localise the UGV. One of the major requirements is to use the minimum number of UAVs, which is two UAVs in this paper. Using only two UAVs leads to a significant complication that results an estimation unobservability under certain circumstances. As a solution to the unobservability problem, the main contribution of this paper is to present a methodology to treat the unobservability problem. A Constrained Extended Kalman Filter (CEKF)-based solution, which uses novel kinematics and heuristics-based constraints, is presented. The proposed methodology has been assessed based on the stochastic observability using the Posterior Cramér–Rao Bound (PCRB), and the results demonstrate the successful operation of the proposed localisation method.
- 19 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (5) , 1314-1320
Design and Development of a Novel Oral Care Simulator for the Training of Nurses
Objective: A Novel Oral Care Simulator was designed and developed to measure and visualise the facial and lingual forces exerted on teeth by the action of tooth brushing, considering the irregular geometry and structural composition of human dentition and the emulation of the realistic biomechanical deflection of the teeth. Method: FEA simulations were carried out on a central incisor under facial loading and an appropriate force sensing mechanism was designed. An anatomically accurate mandibular jaw and 16 teeth were 3D printed, on which 16 force sensing structures were embedded. The signals from the sensors were amplified using a multichannel signal amplifier built using instrumentation amplifiers which were then visualised through a GUI. Results: The developed simulator is capable of indicating the magnitude of a force upto 15 N exerted on to the facial and lingual surfaces of teeth at a frequency of 60 Hz and above and it is capable of alerting the user if the force exceeds a pre-specified threshold. Conclusion: The designed force sensing mechanism considers the irregular geometry and structural composition of human dentition in measuring the facial and lingual forces. It provides a reliable feedback by indicating the force and emulating the realistic biomechanical deflection of teeth. Significance: Nurses who care for the disabled, elderly and sick have explicitly stated the requirement for a simulator to train themselves on brushing the teeth of their subjects as their incorrect technique can cause longterm dental damage, for which a device has not been developed to date.
- 19 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (5) , 1314-1320
Design and Development of a Novel Oral Care Simulator for the Training of Nurses
Objective: A Novel Oral Care Simulator was designed and developed to measure and visualise the facial and lingual forces exerted on teeth by the action of tooth brushing, considering the irregular geometry and structural composition of human dentition and the emulation of the realistic biomechanical deflection of the teeth. Method: FEA simulations were carried out on a central incisor under facial loading and an appropriate force sensing mechanism was designed. An anatomically accurate mandibular jaw and 16 teeth were 3D printed, on which 16 force sensing structures were embedded. The signals from the sensors were amplified using a multichannel signal amplifier built using instrumentation amplifiers which were then visualised through a GUI. Results: The developed simulator is capable of indicating the magnitude of a force upto 15 N exerted on to the facial and lingual surfaces of teeth at a frequency of 60 Hz and above and it is capable of alerting the user if the force exceeds a pre-specified threshold. Conclusion: The designed force sensing mechanism considers the irregular geometry and structural composition of human dentition in measuring the facial and lingual forces. It provides a reliable feedback by indicating the force and emulating the realistic biomechanical deflection of teeth. Significance: Nurses who care for the disabled, elderly and sick have explicitly stated the requirement for a simulator to train themselves on brushing the teeth of their subjects as their incorrect technique can cause longterm dental damage, for which a device has not been developed to date.
- Open Access
Development of a Conductive Polymer Based Novel 1-DOF Tactile Sensor with Cylindrical Arch Spring Structure Using 3D Printing Technology
Under this research, a novel tactile sensor has been developed using a conductive polymer-based sensing element. The incorporated sensing element is manufactured by polymer press moulding, where the compound is based on silicone rubber and has enhancements by silica and carbon black, with Silane-69 as the coupling agent. Characteristics of the sensing element have been observed using its sensitivity and range, where its results pose an inherent nonlinearity of conductive polymers. For the force scaling purpose, a novel 3D printed cylindrical arch spring structure was developed for this highly customizable tactile sensor by adopting commonly available ABSplus material in 3D printing technology. By considering critical dimensions of the structure, finite element analysis was carried out to achieve nearly optimized results. A special electrical routing arrangement was also designed to reduce the routing complexities. The optimized structure was fabricated using the 3D printing technology. A microcontroller-based signal conditioning circuit was introduced to the system for the purpose of acquiring data. The sensor has been tested up to the maximum load condition using a force indenter. This sensor has a maximum applicable range of 90 N with a maximum structural deflection of 4 mm. The sensor assembly weighs 155 g and the outer dimensions are 85 mm in diameter and 83 mm in height.
Open AccessDevelopment of a Conductive Polymer Based Novel 1-DOF Tactile Sensor with Cylindrical Arch Spring Structure Using 3D Printing Technology
Under this research, a novel tactile sensor has been developed using a conductive polymer-based sensing element. The incorporated sensing element is manufactured by polymer press moulding, where the compound is based on silicone rubber and has enhancements by silica and carbon black, with Silane-69 as the coupling agent. Characteristics of the sensing element have been observed using its sensitivity and range, where its results pose an inherent nonlinearity of conductive polymers. For the force scaling purpose, a novel 3D printed cylindrical arch spring structure was developed for this highly customizable tactile sensor by adopting commonly available ABSplus material in 3D printing technology. By considering critical dimensions of the structure, finite element analysis was carried out to achieve nearly optimized results. A special electrical routing arrangement was also designed to reduce the routing complexities. The optimized structure was fabricated using the 3D printing technology. A microcontroller-based signal conditioning circuit was introduced to the system for the purpose of acquiring data. The sensor has been tested up to the maximum load condition using a force indenter. This sensor has a maximum applicable range of 90 N with a maximum structural deflection of 4 mm. The sensor assembly weighs 155 g and the outer dimensions are 85 mm in diameter and 83 mm in height.
- Open Access
- 11 July 2018
- Published by Elsevier in Informatics in Medicine Unlocked
- Vol. 12, 98-105
Development of a novel telecare system, integrated with plantar pressure measurement system
- 11 July 2018
- Published by Elsevier in Informatics in Medicine Unlocked
- Vol. 12, 98-105
Open AccessDevelopment of a novel telecare system, integrated with plantar pressure measurement system