Tomasz Charubin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tomasz Charubin has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Michał Nowicki
Vilnius Gediminas Technical University
14 shared publications - Roman Szewczyk
Systems Research Institute Polish Academy of Sciences
12 shared publications Michał Nowicki
2 shared publications- Paweł Nowak
Warsaw University of Technology
2 shared publications - Piotr Gazda
Warsaw University of Technology
2 shared publications A. Juś
Institute of Metrology and Biomedical Engineering, Warsaw University of Technology, Św. A. Boboli 8, 02-525 Warsaw, Poland
1 shared publication
Latest Publications
- Open Access
- 27 October 2026
- Published by Elsevier in Physica B: Condensed Matter
- Vol. 744
Magnetization scaling and collapse of the pinning energy scale in gadolinium approaching the Curie point
- 27 October 2026
- Published by Elsevier in Physica B: Condensed Matter
- Vol. 744
Open AccessMagnetization scaling and collapse of the pinning energy scale in gadolinium approaching the Curie point
- Open Access
- 21 September 2026
- Published by PIAP - Industrial Research Institute for Automation and Measurements in Journal of Automation, Mobile Robotics and Intelligent Systems
- Vol. 20 (3) , 7-14
Validation of the Eddy-Current Energy Losses in The Gyrator-Capacitor Model of Nanocrystalline Soft Magnetic Core
The paper presents the results of validating the gyrator-capacitor model of frequency dependence characteristic of an inductive core made of Fe73.5Cu1Nb3Si15.5B7 nanocrystalline alloy. The model, focused on eddy current losses, was implemented using the LTSpice software. Experimental results confirmed that a relatively simple description of eddy current losses enables effective modeling of the magnetic hysteresis loop for the driving frequencies up to 36 kHz. Very good agreement of modeling and experimental results was confirmed quantitatively by the R2 coefficient exceeding 0.995. Moreover, results indicate that further research should consider the more detailed functional models of the frequency dependence of the coercive field.
- 21 September 2026
- Published by PIAP - Industrial Research Institute for Automation and Measurements in Journal of Automation, Mobile Robotics and Intelligent Systems
- Vol. 20 (3) , 7-14
Open AccessValidation of the Eddy-Current Energy Losses in The Gyrator-Capacitor Model of Nanocrystalline Soft Magnetic Core
The paper presents the results of validating the gyrator-capacitor model of frequency dependence characteristic of an inductive core made of Fe73.5Cu1Nb3Si15.5B7 nanocrystalline alloy. The model, focused on eddy current losses, was implemented using the LTSpice software. Experimental results confirmed that a relatively simple description of eddy current losses enables effective modeling of the magnetic hysteresis loop for the driving frequencies up to 36 kHz. Very good agreement of modeling and experimental results was confirmed quantitatively by the R2 coefficient exceeding 0.995. Moreover, results indicate that further research should consider the more detailed functional models of the frequency dependence of the coercive field.
- 25 June 2025
- Published by PIAP - Industrial Research Institute for Automation and Measurements in Pomiary Automatyka Robotyka
- Vol. 29 (2) , 77-84
Modular Hysteresisgraph for Measuring the Characteristics of Magnetically Soft Materials
The article presents a computer-controlled, modular and fully automated hysteresisgraph for measuring the characteristics of soft magnetic materials in a wide range of magnetizing field amplitudes. The hysteresisgraph enables measurements of magnetic hysteresis loops using different shapes of the magnetizing field and magnetic induction in the core (sinusoidal, triangular or custom magnetizing field, sinusoidal or triangular magnetic induction) and relative magnetic permeability curves. The modular design of the system enables measurements of magnetic parameters with additional influences of external conditions, such as temperature, mechanical stress or sample rotation angle (anisometer operating system). Open software allows for addition of new measurement methods, which is not possible in commercially available systems.
- 25 June 2025
- Published by PIAP - Industrial Research Institute for Automation and Measurements in Pomiary Automatyka Robotyka
- Vol. 29 (2) , 77-84
Modular Hysteresisgraph for Measuring the Characteristics of Magnetically Soft Materials
The article presents a computer-controlled, modular and fully automated hysteresisgraph for measuring the characteristics of soft magnetic materials in a wide range of magnetizing field amplitudes. The hysteresisgraph enables measurements of magnetic hysteresis loops using different shapes of the magnetizing field and magnetic induction in the core (sinusoidal, triangular or custom magnetizing field, sinusoidal or triangular magnetic induction) and relative magnetic permeability curves. The modular design of the system enables measurements of magnetic parameters with additional influences of external conditions, such as temperature, mechanical stress or sample rotation angle (anisometer operating system). Open software allows for addition of new measurement methods, which is not possible in commercially available systems.
- Open Access
- 1 October 2024
- Published by Institute of Physics, Polish Academy of Sciences in Acta Physica Polonica A
- Vol. 146 (4) , 606-609
Modeling the Matteucci Effect in Non-uniform DC Magnetic Field Sensor
This paper presents a quantitative model for magnetic field sensors based on the Matteucci effect in non-uniform magnetic fields. The Matteucci effect, observed in twisted amorphous wires, generates voltage pulses due to magnetization changes. The model describes non-uniformities by analyzing the effect of spatial gradients in the magnetic field and enables magnetic field gradient measurement. Experimental validation shows that the field gradient introduces an additional delay in re-magnetization, reflected as distinct forked voltage pulses. The proposed model allows for the improvement of sensor performance and extends the application of Matteucci-effect-based sensors to magnetic field mapping and non-destructive testing.
- 1 October 2024
- Published by Institute of Physics, Polish Academy of Sciences in Acta Physica Polonica A
- Vol. 146 (4) , 606-609
Open AccessModeling the Matteucci Effect in Non-uniform DC Magnetic Field Sensor
This paper presents a quantitative model for magnetic field sensors based on the Matteucci effect in non-uniform magnetic fields. The Matteucci effect, observed in twisted amorphous wires, generates voltage pulses due to magnetization changes. The model describes non-uniformities by analyzing the effect of spatial gradients in the magnetic field and enables magnetic field gradient measurement. Experimental validation shows that the field gradient introduces an additional delay in re-magnetization, reflected as distinct forked voltage pulses. The proposed model allows for the improvement of sensor performance and extends the application of Matteucci-effect-based sensors to magnetic field mapping and non-destructive testing.
- Open Access
- 2 May 2023
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 577
A measuring setup for testing the mechanical stress dependence of magnetic properties of electrical steels
- 2 May 2023
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 577
Open AccessA measuring setup for testing the mechanical stress dependence of magnetic properties of electrical steels
- Open Access
Bendductor—Transformer Steel Magnetomechanical Force Sensor
In this paper, the design and investigation of an innovative force sensor, based on the Villari effect, is presented. The sensor was built from electrical steel, in a pressductor pattern, but working in bending load mode. The results of the experimental research allowed for the evaluation of transducer’s performance, mitigation of measurement hysteresis, and optimization of its functional parameters. Several issues have been examined, among them the selection of supply and measured signals, the measured values’ impact on measurement hysteresis, harmonic analysis, and the selection of proper current waveforms and frequencies. The proposed sensor is robust, made from inexpensive materials, and has high sensitivity, as compared to other magnetoelastic sensors. It has much higher stress sensitivity than other magnetoelastic sensors due to deformation mode. Based on the tests, its measuring range can be defined as 0.5–5 N with a near-linear characteristic, SNR of 46 dB, and 0.11 N uncertainty.
Open AccessBendductor—Transformer Steel Magnetomechanical Force Sensor
In this paper, the design and investigation of an innovative force sensor, based on the Villari effect, is presented. The sensor was built from electrical steel, in a pressductor pattern, but working in bending load mode. The results of the experimental research allowed for the evaluation of transducer’s performance, mitigation of measurement hysteresis, and optimization of its functional parameters. Several issues have been examined, among them the selection of supply and measured signals, the measured values’ impact on measurement hysteresis, harmonic analysis, and the selection of proper current waveforms and frequencies. The proposed sensor is robust, made from inexpensive materials, and has high sensitivity, as compared to other magnetoelastic sensors. It has much higher stress sensitivity than other magnetoelastic sensors due to deformation mode. Based on the tests, its measuring range can be defined as 0.5–5 N with a near-linear characteristic, SNR of 46 dB, and 0.11 N uncertainty.
- 28 August 2019
- Published by Springer Nature
- p. 149-156
Laboratory Stand for Fluxgate Level Measurement
- Open Access
Influence of Torsion on Matteucci Effect Signal Parameters in Co-Based Bistable Amorphous Wire
The Matteucci effect (ME) is one of the lesser-known magnetomechanical effects and is most prominent in bistable amorphous wires. It has some experimental applications—Matteucci effect-based magnetic field sensors are very easy to produce and have inherently linear, hybrid analog/digital output signal. The effect is still poorly understood, however, and although it relies on torsion of the wire to manifest, there is no available model, or much experimental data, which would quantitatively connect the ME with the sample twist. In this paper, experimental characteristics of ME signal parameters dependence on torsion in Co-based amorphous bistable wire are presented. The results hint at possible applications, such as rotation or critical current sensors, as well as the necessity of torsion control in the development of ME magnetic field sensors.
Open AccessInfluence of Torsion on Matteucci Effect Signal Parameters in Co-Based Bistable Amorphous Wire
The Matteucci effect (ME) is one of the lesser-known magnetomechanical effects and is most prominent in bistable amorphous wires. It has some experimental applications—Matteucci effect-based magnetic field sensors are very easy to produce and have inherently linear, hybrid analog/digital output signal. The effect is still poorly understood, however, and although it relies on torsion of the wire to manifest, there is no available model, or much experimental data, which would quantitatively connect the ME with the sample twist. In this paper, experimental characteristics of ME signal parameters dependence on torsion in Co-based amorphous bistable wire are presented. The results hint at possible applications, such as rotation or critical current sensors, as well as the necessity of torsion control in the development of ME magnetic field sensors.
- Open Access
Modeling the Hysteresis Loop of Ultra-High Permeability Amorphous Alloy for Space Applications
This paper presents investigation results regarding the Jiles-Atherton-based hysteresis loop modeling of ultra-high permeability amorphous alloy MELTA® MM-5Co. The measurement stand is capable of accurately measuring minor and major hysteresis loops for such a material together with exemplary measurement results. The main source of the measurement error is highlighted, which includes the Earth’s field influence. The results of hysteresis loop modeling with the original Jiles-Atherton model and with two of its modifications are given. In all cases, the parameters of the Jiles-Atherton model were identified in two-step identification on the basis of a differential evolution optimization algorithm. The results indicate that both the original and modified Jiles-Atherton models are suitable for modeling the ultra-soft amorphous alloy. However, the hysteresis model’s parameters vary significantly.
Open AccessModeling the Hysteresis Loop of Ultra-High Permeability Amorphous Alloy for Space Applications
This paper presents investigation results regarding the Jiles-Atherton-based hysteresis loop modeling of ultra-high permeability amorphous alloy MELTA® MM-5Co. The measurement stand is capable of accurately measuring minor and major hysteresis loops for such a material together with exemplary measurement results. The main source of the measurement error is highlighted, which includes the Earth’s field influence. The results of hysteresis loop modeling with the original Jiles-Atherton model and with two of its modifications are given. In all cases, the parameters of the Jiles-Atherton model were identified in two-step identification on the basis of a differential evolution optimization algorithm. The results indicate that both the original and modified Jiles-Atherton models are suitable for modeling the ultra-soft amorphous alloy. However, the hysteresis model’s parameters vary significantly.
- 1 August 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1994 (1) , 020019
Spectral analysis of Matteucci effect based magnetic field sensor
DC magnetic field sensor similar to fluxgates utilizing Matteucci Effect was proposed previously. As these types of sensors depend on measuring the second harmonic of the signal, a spectral analysis of Matteucci effect signal was measured. Results indicate that each harmonic is periodical with the increase of DC magnetic field and the period decreases with the harmonic number, making higher harmonics better suitable for lower measurement ranges. Thus, measurement range of the proposed sensor can be selected by tuning to proper harmonic frequency. Moreover, there is no difference in signal amplitude between odd and even harmonics, so any of them could be used for signal extraction.
- 1 August 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1994 (1) , 020019
Spectral analysis of Matteucci effect based magnetic field sensor
DC magnetic field sensor similar to fluxgates utilizing Matteucci Effect was proposed previously. As these types of sensors depend on measuring the second harmonic of the signal, a spectral analysis of Matteucci effect signal was measured. Results indicate that each harmonic is periodical with the increase of DC magnetic field and the period decreases with the harmonic number, making higher harmonics better suitable for lower measurement ranges. Thus, measurement range of the proposed sensor can be selected by tuning to proper harmonic frequency. Moreover, there is no difference in signal amplitude between odd and even harmonics, so any of them could be used for signal extraction.