Jani Pirinen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jani Pirinen has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Juha Sinisalo
Department of Cardiology, Helsinki University Hospital, Helsinki, Finland
14 shared publications Jukka Putaala
12 shared publicationsMika Lehto
Department of Cardiology, Heart and Lung Center, Helsinki University Hospital, Helsinki, Finland
8 shared publications- Markku Kaste
Department of Neurology, Helsinki University Central Hospital, Helsinki, Finland
7 shared publications Vesa Järvinen
7 shared publications- Jukka Putaala
Department of Neurology, Helsinki University Hospital, Finland
6 shared publications
Latest Publications
- Open Access
- 27 March 2026
- Published by Springer Nature in High Blood Pressure & Cardiovascular Prevention
- Vol. 33 (4) , 453-462
Cardiac Organ Damage in Young Adults with Cryptogenic Ischaemic Stroke: The SECRETO Study
Introduction Cardiac organ damage (OD) is associated with increased risk of cardiovascular disease. However, limited knowledge exists on cardiac OD in young patients with cryptogenic ischaemic stroke (CIS). Aim To explore prevalence and covariates of cardiac OD in patients with CIS compared to controls participating in the SECRETO study. Methods We analysed data from 427 patients with CIS aged p < 0.01), while presence of LAE did not differ. In multivariable analyses, CIS was associated with presence of abnormal LV geometry (odds ratio 1.86 [95% confidence interval 1.09–3.20], p=0.024). In separate multivariable analyses in patients only, obesity was associated with both abnormal LV geometry and LAE (both p < 0.01), and higher systolic blood pressure only with presence of abnormal LV geometry (p < 0.001). No significant association with PFO was found. Conclusion In young patients with CIS participating in the SECRETO study, abnormal LV geometry was more prevalent compared to age- and sex-matched controls and associated with presence of higher blood pressure and obesity. The results point to the importance of blood pressure and weight control in CIS to prevent progression of cardiac OD and recurrent cardiovascular events. Graphical Abstract
- 27 March 2026
- Published by Springer Nature in High Blood Pressure & Cardiovascular Prevention
- Vol. 33 (4) , 453-462
Open AccessCardiac Organ Damage in Young Adults with Cryptogenic Ischaemic Stroke: The SECRETO Study
Introduction Cardiac organ damage (OD) is associated with increased risk of cardiovascular disease. However, limited knowledge exists on cardiac OD in young patients with cryptogenic ischaemic stroke (CIS). Aim To explore prevalence and covariates of cardiac OD in patients with CIS compared to controls participating in the SECRETO study. Methods We analysed data from 427 patients with CIS aged p < 0.01), while presence of LAE did not differ. In multivariable analyses, CIS was associated with presence of abnormal LV geometry (odds ratio 1.86 [95% confidence interval 1.09–3.20], p=0.024). In separate multivariable analyses in patients only, obesity was associated with both abnormal LV geometry and LAE (both p < 0.01), and higher systolic blood pressure only with presence of abnormal LV geometry (p < 0.001). No significant association with PFO was found. Conclusion In young patients with CIS participating in the SECRETO study, abnormal LV geometry was more prevalent compared to age- and sex-matched controls and associated with presence of higher blood pressure and obesity. The results point to the importance of blood pressure and weight control in CIS to prevent progression of cardiac OD and recurrent cardiovascular events. Graphical Abstract
- Open Access
- 7 January 2025
- Published by S. Karger AG in Cardiology
- Vol. 150 (5) , 525-539
Multimodality Cardiac Imaging in Ischemic Stroke: Insights into the Heart-Brain Interaction
Background: Approximately 7.6 million individuals experience a new ischemic stroke each year, and roughly 25% of all ischemic strokes are cardiogenic in origin, carrying a high risk of recurrence, death, and disability. To prevent future ischemic strokes, especially in younger individuals, it is crucial to detect and treat direct and indirect cardioembolic sources. Summary: Cardiac imaging is a rapidly evolving field, and post-stroke cardiac imaging is no longer limited to echocardiography but also includes other imaging techniques, such as cardiac magnetic resonance imaging and cardiac computed tomography. Clinicians must be familiar with numerous cardiac and systemic disorders related to stroke and consider the possibilities that imaging diagnostics have to offer. Additional diagnostic tests, such as pre- and transcranial ultrasound with a bubble test, can also increase the diagnostic accuracy for detecting right-left shunt embolisms. Moreover, a patent foramen ovale (PFO) has traditionally been considered as a minor or uncertain risk factor for ischemic stroke. However, PFO-associated strokes are a distinct category among the cardioembolic sources, as in most cases, we do not assume that the thrombus has been developed in situ in the PFO structure or elsewhere intracardially, rather, the PFO merely acts as a mediator for a paradoxical, venous embolism. The article has two parts: Part I, the heart-brain axis, describes multimodality cardiac imaging in the assessment of cardioembolic sources of ischemic stroke, with a special focus on disorders that traditionally have received little attention in the literature. Part II discusses the brain-heart axis, namely, when acute cerebrovascular events lead to cardiac dysfunction, for example, neurogenic stunned myocardium and Takotsubo syndrome. Key Messages: Advances in cardiovascular imaging have significantly enhanced the detection of cardiac disorders associated with stroke. Clinicians involved in post-stroke workup need to be aware of the capabilities of different imaging modalities to ensure high diagnostic accuracy in order to effectively treat and prevent stroke recurrence.
- 7 January 2025
- Published by S. Karger AG in Cardiology
- Vol. 150 (5) , 525-539
Open AccessMultimodality Cardiac Imaging in Ischemic Stroke: Insights into the Heart-Brain Interaction
Background: Approximately 7.6 million individuals experience a new ischemic stroke each year, and roughly 25% of all ischemic strokes are cardiogenic in origin, carrying a high risk of recurrence, death, and disability. To prevent future ischemic strokes, especially in younger individuals, it is crucial to detect and treat direct and indirect cardioembolic sources. Summary: Cardiac imaging is a rapidly evolving field, and post-stroke cardiac imaging is no longer limited to echocardiography but also includes other imaging techniques, such as cardiac magnetic resonance imaging and cardiac computed tomography. Clinicians must be familiar with numerous cardiac and systemic disorders related to stroke and consider the possibilities that imaging diagnostics have to offer. Additional diagnostic tests, such as pre- and transcranial ultrasound with a bubble test, can also increase the diagnostic accuracy for detecting right-left shunt embolisms. Moreover, a patent foramen ovale (PFO) has traditionally been considered as a minor or uncertain risk factor for ischemic stroke. However, PFO-associated strokes are a distinct category among the cardioembolic sources, as in most cases, we do not assume that the thrombus has been developed in situ in the PFO structure or elsewhere intracardially, rather, the PFO merely acts as a mediator for a paradoxical, venous embolism. The article has two parts: Part I, the heart-brain axis, describes multimodality cardiac imaging in the assessment of cardioembolic sources of ischemic stroke, with a special focus on disorders that traditionally have received little attention in the literature. Part II discusses the brain-heart axis, namely, when acute cerebrovascular events lead to cardiac dysfunction, for example, neurogenic stunned myocardium and Takotsubo syndrome. Key Messages: Advances in cardiovascular imaging have significantly enhanced the detection of cardiac disorders associated with stroke. Clinicians involved in post-stroke workup need to be aware of the capabilities of different imaging modalities to ensure high diagnostic accuracy in order to effectively treat and prevent stroke recurrence.
- Open Access
- 19 September 2023
- Published by Wiley in Echocardiography
- Vol. 40 (11) , 1177-1186
A method for measuring the angle between left atrial and left ventricular long axes using 3D echocardiography
BackgroundLeft ventricle (LV) optimized views are routinely used for left atrial (LA) volume and strain measurements on 2D echocardiography. This might be a source of the error because of the variation of the angle between the left atrial and left ventricle long axes (LA-LV angle), leading to foreshortening of the LA.MethodsWe investigated two novel parameters: the angle between the left atrial and left ventricle long axes (LA-LV angle) and its deviation from the 4-chamber plane. To accurately measure the angles in 3D space, these measurements were performed using 3D echocardiography. We developed a method for the measurement based on marking anatomic points of reference in the 3D echocardiogram and measuring the angles between these points. We used three types of phantoms made of wood and agar-agar to investigate the repeatability and reproducibility of these measurements and performed measurements on human subjects.ResultsThe ultrasound measurements were in excellent agreement with the true angles of the phantoms: LA-LV angle bias was .5 degrees (95% CI -1.8 to +2.7) in the wooden phantoms and 1.2 degrees (-.7 to +3.1) in the agar-agar phantoms, while the angle deviation from the 4-chamber plane was -.9 degrees (-4.3 to +4.1) in the wooden phantoms and .0 degrees (-3.3 to +3.3) in the agar-agar phantoms. The measurements demonstrated good repeatability and reproducibility (Pearson correlation coefficients ranging from .91 to .99). The measurements from human hearts showed good repeatability (Pearson correlation was .81 for repeated LA-LV angle measurements and .97 for repeated measurements of the deviation from the 4-chamber plane).ConclusionThe measurement of the LA-LV angle is a feasible tool to investigate one eventual error of 2D echocardiography.
- 19 September 2023
- Published by Wiley in Echocardiography
- Vol. 40 (11) , 1177-1186
Open AccessA method for measuring the angle between left atrial and left ventricular long axes using 3D echocardiography
BackgroundLeft ventricle (LV) optimized views are routinely used for left atrial (LA) volume and strain measurements on 2D echocardiography. This might be a source of the error because of the variation of the angle between the left atrial and left ventricle long axes (LA-LV angle), leading to foreshortening of the LA.MethodsWe investigated two novel parameters: the angle between the left atrial and left ventricle long axes (LA-LV angle) and its deviation from the 4-chamber plane. To accurately measure the angles in 3D space, these measurements were performed using 3D echocardiography. We developed a method for the measurement based on marking anatomic points of reference in the 3D echocardiogram and measuring the angles between these points. We used three types of phantoms made of wood and agar-agar to investigate the repeatability and reproducibility of these measurements and performed measurements on human subjects.ResultsThe ultrasound measurements were in excellent agreement with the true angles of the phantoms: LA-LV angle bias was .5 degrees (95% CI -1.8 to +2.7) in the wooden phantoms and 1.2 degrees (-.7 to +3.1) in the agar-agar phantoms, while the angle deviation from the 4-chamber plane was -.9 degrees (-4.3 to +4.1) in the wooden phantoms and .0 degrees (-3.3 to +3.3) in the agar-agar phantoms. The measurements demonstrated good repeatability and reproducibility (Pearson correlation coefficients ranging from .91 to .99). The measurements from human hearts showed good repeatability (Pearson correlation was .81 for repeated LA-LV angle measurements and .97 for repeated measurements of the deviation from the 4-chamber plane).ConclusionThe measurement of the LA-LV angle is a feasible tool to investigate one eventual error of 2D echocardiography.
- 24 January 2022
- Published by S. Karger AG in Cardiology
- Vol. 147 (2) , 169-178
Orientation of the Atrial Septum to the Inferior Vena Cava May Contribute to the Persistent Patency of the Foramen Ovale
Purpose: There is growing evidence that paradoxical embolism through patent foramen ovale (PFO) is a cause for cryptogenic stroke. However, it is still unclear why the foramen ovale fails to close after birth. We studied whether the 3D relations between the atrial septum (AS) and the inferior vena cava (IVC) are associated with PFO. Methods: We recruited 30 patients (18–49 years) with a first-ever cryptogenic stroke and 30 age- and sex-matched stroke-free controls. Using cardiac magnetic resonance, an approach to evaluate the 3D relations between the AS and the IVC was developed. The presence of interatrial right-to-left shunt was evaluated with transesophageal echocardiography (TEE) in patients and transcranial Doppler in controls. Results: Of 30 patients, 29 underwent successful TEE, of which 12 (41%) had a shunt. Patients with a shunt had a greater mean 3D angle (γ) between the atrial septal plane and the vector from the orifice of the IVC to the middle of the AS compared with patients without a shunt (45 ± 9° vs. 36 ± 8°, p = 0.017). Of 30 controls, 12 (40%) had a shunt and a greater mean γ compared with controls without a shunt (47 ± 8° vs. 37 ± 10°, p = 0.007). In a pooled analysis, 24 (41%) of 59 subjects with a shunt had a mean γ of 46 ± 9° compared with subjects without a shunt of 37 ± 9° (p < 0.001). Conclusions: More perpendicular orientation of the atrial septal plane to the orifice of the IVC is associated with PFO, possibly by directing the IVC flow to PFO.
- 24 January 2022
- Published by S. Karger AG in Cardiology
- Vol. 147 (2) , 169-178
Orientation of the Atrial Septum to the Inferior Vena Cava May Contribute to the Persistent Patency of the Foramen Ovale
Purpose: There is growing evidence that paradoxical embolism through patent foramen ovale (PFO) is a cause for cryptogenic stroke. However, it is still unclear why the foramen ovale fails to close after birth. We studied whether the 3D relations between the atrial septum (AS) and the inferior vena cava (IVC) are associated with PFO. Methods: We recruited 30 patients (18–49 years) with a first-ever cryptogenic stroke and 30 age- and sex-matched stroke-free controls. Using cardiac magnetic resonance, an approach to evaluate the 3D relations between the AS and the IVC was developed. The presence of interatrial right-to-left shunt was evaluated with transesophageal echocardiography (TEE) in patients and transcranial Doppler in controls. Results: Of 30 patients, 29 underwent successful TEE, of which 12 (41%) had a shunt. Patients with a shunt had a greater mean 3D angle (γ) between the atrial septal plane and the vector from the orifice of the IVC to the middle of the AS compared with patients without a shunt (45 ± 9° vs. 36 ± 8°, p = 0.017). Of 30 controls, 12 (40%) had a shunt and a greater mean γ compared with controls without a shunt (47 ± 8° vs. 37 ± 10°, p = 0.007). In a pooled analysis, 24 (41%) of 59 subjects with a shunt had a mean γ of 46 ± 9° compared with subjects without a shunt of 37 ± 9° (p < 0.001). Conclusions: More perpendicular orientation of the atrial septal plane to the orifice of the IVC is associated with PFO, possibly by directing the IVC flow to PFO.
- Open Access
- 1 June 2021
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 22 (Supplement)
Magnetic resonance imaging derived cardiac first pass perfusion in cryptogenic ischemic stroke in the young
Type of funding sources: None. Up to 50% of ischemic strokes in adults aged between 18 and 50 are cryptogenic by nature. Heart has been a hypothesised source. Purpose: Purpose of the study was to investigate the wash in and wash out of gadolinium based contrast agent in the left atrial appendage, and cardiac chambers in first pass cardiac magnetic resonance imaging. The study comprised 30 patients with first-ever cryptogenic ischemic stroke and 30 age and gender matched stroke-free controls included in the prospective multicenter study Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers and Outcome (SECRETO; NCT01934725). Cardiac magnetic resonance imaging was performed on all participants with a 1.5T magnetic resonance system. Dynamic contrast enhanced T1 weighted first pass perfusion images were acquired in the superior vena cava, the left atrial appendage (Fig. 1), and the left ventricle. The images were analyzed for time-intensity curves (Fig. 2), and results were normalised to individual heart rate. Arrival times, peak times, areas under the curves, relative blood flows (defined as area under the curve/full width at half maximum), and maximum and minimum rates of bolus wash in / wash out were calculated. The wash in of the contrast agent bolus was similar in patients and controls. Arrival times and peak timings showed similar characteristics in patients and controls in the left atrial appendage (arrival time: 12.4 [2.3] vs. 13.5 [3.6] cardiac cycles, p = 0.657; peak time: 19.6 [5.1] vs. 19.8 [6.9] cardiac cycles, p = 0.929) and the left atrium (arrival time: 12.2 [2.8] vs. 13.0 [3.6] cardiac cycles, p = 0.535; peak time: 18.7 [5.5] vs. 18.1 [5.2] cardiac cycles, p = 0.790). Areas under under the curves and relative blood flows were similar in patients and controls. A significant difference between patients and controls was found in the wash out rate of gadolinium in the left ventricle (-28 [11] vs. -36 [13] 1/cardiac cycles, p = 0.012), indicating slightly slower wash out in the patients. Cryptogenic ischemic stroke in the young is not associated with prolonged blood flow in the left atrial appendage or left atrium. There were no significant differences in the first pass perfusion between subjects and healthy controls. However, there might be a slight tendency for stagnation of blood flow in the left ventricles of cryptogenic stroke patients. Abstract Figure. Fig 1. Example of first pass perfusion Abstract Figure. Fig 1. Example of first pass perfusion Abstract Figure. Fig 2. Time intensity curves Abstract Figure. Fig 2. Time intensity curves
- 1 June 2021
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 22 (Supplement)
Open AccessMagnetic resonance imaging derived cardiac first pass perfusion in cryptogenic ischemic stroke in the young
Type of funding sources: None. Up to 50% of ischemic strokes in adults aged between 18 and 50 are cryptogenic by nature. Heart has been a hypothesised source. Purpose: Purpose of the study was to investigate the wash in and wash out of gadolinium based contrast agent in the left atrial appendage, and cardiac chambers in first pass cardiac magnetic resonance imaging. The study comprised 30 patients with first-ever cryptogenic ischemic stroke and 30 age and gender matched stroke-free controls included in the prospective multicenter study Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers and Outcome (SECRETO; NCT01934725). Cardiac magnetic resonance imaging was performed on all participants with a 1.5T magnetic resonance system. Dynamic contrast enhanced T1 weighted first pass perfusion images were acquired in the superior vena cava, the left atrial appendage (Fig. 1), and the left ventricle. The images were analyzed for time-intensity curves (Fig. 2), and results were normalised to individual heart rate. Arrival times, peak times, areas under the curves, relative blood flows (defined as area under the curve/full width at half maximum), and maximum and minimum rates of bolus wash in / wash out were calculated. The wash in of the contrast agent bolus was similar in patients and controls. Arrival times and peak timings showed similar characteristics in patients and controls in the left atrial appendage (arrival time: 12.4 [2.3] vs. 13.5 [3.6] cardiac cycles, p = 0.657; peak time: 19.6 [5.1] vs. 19.8 [6.9] cardiac cycles, p = 0.929) and the left atrium (arrival time: 12.2 [2.8] vs. 13.0 [3.6] cardiac cycles, p = 0.535; peak time: 18.7 [5.5] vs. 18.1 [5.2] cardiac cycles, p = 0.790). Areas under under the curves and relative blood flows were similar in patients and controls. A significant difference between patients and controls was found in the wash out rate of gadolinium in the left ventricle (-28 [11] vs. -36 [13] 1/cardiac cycles, p = 0.012), indicating slightly slower wash out in the patients. Cryptogenic ischemic stroke in the young is not associated with prolonged blood flow in the left atrial appendage or left atrium. There were no significant differences in the first pass perfusion between subjects and healthy controls. However, there might be a slight tendency for stagnation of blood flow in the left ventricles of cryptogenic stroke patients. Abstract Figure. Fig 1. Example of first pass perfusion Abstract Figure. Fig 1. Example of first pass perfusion Abstract Figure. Fig 2. Time intensity curves Abstract Figure. Fig 2. Time intensity curves
- Open Access
- 1 February 2021
- Published by Wiley in Echocardiography
- Vol. 38 (2) , 271-279
Evidence of subtle left ventricular systolic dysfunction in cryptogenic stroke in the young
Introduction: Ischemic stroke in young patients often remains cryptogenic, that is, no underlying reason can be found. Some of these strokes may originate in the heart. Left ventricular (LV) dynamic volumetry and strain analysis are relatively new and promising methods for evaluating LV function. Methods: In this pilot study, we recruited 30 young (18-50 years) patients with cryptogenic ischemic stroke and 30 age- and sex-matched controls from the SECRETO study (NCT01934725). The LV systolic function was assessed by LV volumetry (ejection fraction, peak emptying rate, and time to peak emptying rate). The longitudinal systolic function was assessed by speckle tracking strain and strain rate imaging, and by tissue velocity imaging derived MAD (mitral annular displacement) and septal S'. Results: Stroke patients had less vigorous global longitudinal strain (median -18.9, interquartile range 3.3), compared to healthy controls (median -20.0, interquartile range 2.8), P = .010. There was no statistically significant differences in septal S', MAD, global longitudinal strain rate, or dynamic volumetry-derived parameters between the two groups. Conclusions: Young cryptogenic stroke patients have subtly altered systolic function compared to healthy controls, found merely with longitudinal strain analysis. This infers that the heart may play a role in the pathogenesis of cryptogenic ischemic stroke.
- 1 February 2021
- Published by Wiley in Echocardiography
- Vol. 38 (2) , 271-279
Open AccessEvidence of subtle left ventricular systolic dysfunction in cryptogenic stroke in the young
Introduction: Ischemic stroke in young patients often remains cryptogenic, that is, no underlying reason can be found. Some of these strokes may originate in the heart. Left ventricular (LV) dynamic volumetry and strain analysis are relatively new and promising methods for evaluating LV function. Methods: In this pilot study, we recruited 30 young (18-50 years) patients with cryptogenic ischemic stroke and 30 age- and sex-matched controls from the SECRETO study (NCT01934725). The LV systolic function was assessed by LV volumetry (ejection fraction, peak emptying rate, and time to peak emptying rate). The longitudinal systolic function was assessed by speckle tracking strain and strain rate imaging, and by tissue velocity imaging derived MAD (mitral annular displacement) and septal S'. Results: Stroke patients had less vigorous global longitudinal strain (median -18.9, interquartile range 3.3), compared to healthy controls (median -20.0, interquartile range 2.8), P = .010. There was no statistically significant differences in septal S', MAD, global longitudinal strain rate, or dynamic volumetry-derived parameters between the two groups. Conclusions: Young cryptogenic stroke patients have subtly altered systolic function compared to healthy controls, found merely with longitudinal strain analysis. This infers that the heart may play a role in the pathogenesis of cryptogenic ischemic stroke.
- Open Access
- 27 September 2020
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 25 (6)
Prolonged ECG with a novel recorder utilizing electrode belt and mobile device in patients with recent embolic stroke of undetermined source: A pilot study
Background: Paroxysmal atrial fibrillation (pAF) is a major risk factor for ischemic stroke, but challenging to detect with routine short‐term monitoring methods. In this pilot study, we present a novel method for prolonged ECG and screening for pAF in patients with a recent embolic stroke of unknown source (ESUS).Methods: Fifteen patients aged ≥ 50 years with a recent ESUS were assigned to wear an external electrode belt‐based 1‐lead ECG device (Beat2Phone) continuously for 2 weeks (wear time). The device was operated via a mobile phone application in nonhospital conditions. The primary outcome was patient adherence to monitoring. Secondary outcomes were incidence of new pAF, quality‐wise comparison to Holter, and usability of the novel ECG monitoring method with Systems Usability Scale (SUS). We also performed a 24‐ to 48‐hr comparison between simultaneous Beat2Phone ECG and a standard Holter in 6 patients.Results: Wear time of Beat2Phone device was over 80% in 5 (33.3%) patients, 50%–80% in 7 (46.6%) patients, and less than 50% in 3 (20%) patients. We detected pAF ≥ 30 s in 1 patient (6.7%). In the simultaneous monitoring with Beat2Phone and Holter, there were a total of 817 (out of 1979) analyzable periods of sinus rhythm or premature atrial or ventricular beats (Cohen's Kappa coefficient 0.92 ± 0.02 between Beat2Phone and Holter), and no pAF events. Beat2Phone ECG showed remarkable SUS scores in user evaluations (average score: 81.4 out of 100 on SUS).Conclusions: Beat2Phone device was easy to use among ESUS patients and in optimal conditions provided high‐quality 1‐lead ECG signal for diagnosing pAF.Clinical trial registration: The study was not registered, as it was a nonrandomized single‐arm pilot study.
- 27 September 2020
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 25 (6)
Open AccessProlonged ECG with a novel recorder utilizing electrode belt and mobile device in patients with recent embolic stroke of undetermined source: A pilot study
Background: Paroxysmal atrial fibrillation (pAF) is a major risk factor for ischemic stroke, but challenging to detect with routine short‐term monitoring methods. In this pilot study, we present a novel method for prolonged ECG and screening for pAF in patients with a recent embolic stroke of unknown source (ESUS).Methods: Fifteen patients aged ≥ 50 years with a recent ESUS were assigned to wear an external electrode belt‐based 1‐lead ECG device (Beat2Phone) continuously for 2 weeks (wear time). The device was operated via a mobile phone application in nonhospital conditions. The primary outcome was patient adherence to monitoring. Secondary outcomes were incidence of new pAF, quality‐wise comparison to Holter, and usability of the novel ECG monitoring method with Systems Usability Scale (SUS). We also performed a 24‐ to 48‐hr comparison between simultaneous Beat2Phone ECG and a standard Holter in 6 patients.Results: Wear time of Beat2Phone device was over 80% in 5 (33.3%) patients, 50%–80% in 7 (46.6%) patients, and less than 50% in 3 (20%) patients. We detected pAF ≥ 30 s in 1 patient (6.7%). In the simultaneous monitoring with Beat2Phone and Holter, there were a total of 817 (out of 1979) analyzable periods of sinus rhythm or premature atrial or ventricular beats (Cohen's Kappa coefficient 0.92 ± 0.02 between Beat2Phone and Holter), and no pAF events. Beat2Phone ECG showed remarkable SUS scores in user evaluations (average score: 81.4 out of 100 on SUS).Conclusions: Beat2Phone device was easy to use among ESUS patients and in optimal conditions provided high‐quality 1‐lead ECG signal for diagnosing pAF.Clinical trial registration: The study was not registered, as it was a nonrandomized single‐arm pilot study.
- Open Access
- 14 August 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (8) , e0237228
Left ventricular non-compaction as a potential source for cryptogenic ischemic stroke in the young: A case-control study
Up to 50% of ischemic strokes in the young after thorough diagnostic work-up remain cryptogenic or associated with low-risk sources of cardioembolism such as patent foramen ovale (PFO). We studied with cardiac magnetic resonance (CMR) imaging, whether left ventricular (LV) non-compaction—a possible source for embolic stroke due to sluggish blood flow in deep intertrabecular recesses—is associated with cryptogenic strokes in the young. Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers, and Outcome (SECRETO; NCT01934725) is an international prospective multicenter case-control study of young adults (aged 18–49 years) presenting with an imaging-positive first-ever ischemic stroke of undetermined etiology. In this pilot substudy, 30 cases and 30 age- and sex-matched stroke-free controls were examined with CMR. Transcranial Doppler (TCD) bubble test was performed to evaluate the presence and magnitude of right-to-left shunt (RLS). There were no significant differences in LV volumes, masses or systolic function between cases and controls; none of the participants had non-compaction cardiomyopathy. Semi-automated assessment of LV non-compaction was highly reproducible. Non-compacted LV mass (median 14.0 [interquartile range 12.6–16.0] g/m2 vs. 12.7 [10.4–16.6] g/m2, p = 0.045), the ratio of non-compacted to compacted LV mass (mean 25.6 ± 4.2% vs. 22.8 ± 6.0%, p = 0.015) and the percentage of non-compacted LV volume (mean 17.6 ± 2.9% vs. 15.7 ± 3.8%, p = 0.004) were higher in cases compared to controls. In a multivariate conditional logistic regression model including non-compacted LV volume, RLS and body mass index, the percentage of non-compacted LV volume (odds ratio [OR] 1.55, 95% confidence interval [CI] 1.10–2.18, p = 0.011) and the presence of RLS (OR 11.94, 95% CI 1.14–124.94, p = 0.038) were independently associated with cryptogenic ischemic stroke. LV non-compaction is associated with a heightened risk of cryptogenic ischemic stroke in young adults, independent of concomitant RLS and in the absence of cardiomyopathy. SECRETO; NCT01934725. Registered 4th September 2013. https://clinicaltrials.gov/ct2/show/NCT01934725
- 14 August 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (8) , e0237228
Open AccessLeft ventricular non-compaction as a potential source for cryptogenic ischemic stroke in the young: A case-control study
Up to 50% of ischemic strokes in the young after thorough diagnostic work-up remain cryptogenic or associated with low-risk sources of cardioembolism such as patent foramen ovale (PFO). We studied with cardiac magnetic resonance (CMR) imaging, whether left ventricular (LV) non-compaction—a possible source for embolic stroke due to sluggish blood flow in deep intertrabecular recesses—is associated with cryptogenic strokes in the young. Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers, and Outcome (SECRETO; NCT01934725) is an international prospective multicenter case-control study of young adults (aged 18–49 years) presenting with an imaging-positive first-ever ischemic stroke of undetermined etiology. In this pilot substudy, 30 cases and 30 age- and sex-matched stroke-free controls were examined with CMR. Transcranial Doppler (TCD) bubble test was performed to evaluate the presence and magnitude of right-to-left shunt (RLS). There were no significant differences in LV volumes, masses or systolic function between cases and controls; none of the participants had non-compaction cardiomyopathy. Semi-automated assessment of LV non-compaction was highly reproducible. Non-compacted LV mass (median 14.0 [interquartile range 12.6–16.0] g/m2 vs. 12.7 [10.4–16.6] g/m2, p = 0.045), the ratio of non-compacted to compacted LV mass (mean 25.6 ± 4.2% vs. 22.8 ± 6.0%, p = 0.015) and the percentage of non-compacted LV volume (mean 17.6 ± 2.9% vs. 15.7 ± 3.8%, p = 0.004) were higher in cases compared to controls. In a multivariate conditional logistic regression model including non-compacted LV volume, RLS and body mass index, the percentage of non-compacted LV volume (odds ratio [OR] 1.55, 95% confidence interval [CI] 1.10–2.18, p = 0.011) and the presence of RLS (OR 11.94, 95% CI 1.14–124.94, p = 0.038) were independently associated with cryptogenic ischemic stroke. LV non-compaction is associated with a heightened risk of cryptogenic ischemic stroke in young adults, independent of concomitant RLS and in the absence of cardiomyopathy. SECRETO; NCT01934725. Registered 4th September 2013. https://clinicaltrials.gov/ct2/show/NCT01934725
- Open Access
- 14 May 2020
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 40 (5) , 336-342
Diastolic function in young patients with cryptogenic stroke: A case–control pilot study
Background Ischemic stroke in young individuals often remains cryptogenic. In this pilot study we investigated, whether advanced echocardiography methods could find differences in the diastolic function between young cryptogenic stroke patients and stroke‐free controls. Methods We recruited 30 cryptogenic ischemic stroke patients aged 18‐49 and 30 age‐ and sex‐matched stroke‐free controls among participants of the Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers, and Outcome (SECRETO) study (NCT01934725). We measured diastolic function parameters derived from speckle tracking strain rate, Doppler techniques, and 4D volumetry. We also performed statistical analyses comparing only the highest and lowest tertile of cases and controls for each parameter. Results None of our patients or controls had diastolic dysfunction according to ASE/EACVI criteria. However, compared to stroke‐free controls, the stroke patient group had lower E/A‐ratio of mitral inflow, lower lateral and mean e’, lower A/a’ ratio, lower strain rate in early diastole, and lower speckle tracking‐derived e/a‐ratio. When comparing the lowest tertiles, patients also had a lower peak filling rate by 4D volumetry, a lower peak early filling fraction (fraction of left ventricular filling during early diastole), and lower velocities in a series of the tissue Doppler‐derived diastolic parameters and blood flow/tissue velocity‐ratios. Conclusion Our study displayed subtle differences in diastolic function between patients and stroke‐free controls, which may play a role in early‐onset cryptogenic stroke. The differences were clearer when the lowest tertiles were compared, suggesting that there is a subgroup of young cryptogenic stroke patients with subclinical heart disease.
- 14 May 2020
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 40 (5) , 336-342
Open AccessDiastolic function in young patients with cryptogenic stroke: A case–control pilot study
Background Ischemic stroke in young individuals often remains cryptogenic. In this pilot study we investigated, whether advanced echocardiography methods could find differences in the diastolic function between young cryptogenic stroke patients and stroke‐free controls. Methods We recruited 30 cryptogenic ischemic stroke patients aged 18‐49 and 30 age‐ and sex‐matched stroke‐free controls among participants of the Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers, and Outcome (SECRETO) study (NCT01934725). We measured diastolic function parameters derived from speckle tracking strain rate, Doppler techniques, and 4D volumetry. We also performed statistical analyses comparing only the highest and lowest tertile of cases and controls for each parameter. Results None of our patients or controls had diastolic dysfunction according to ASE/EACVI criteria. However, compared to stroke‐free controls, the stroke patient group had lower E/A‐ratio of mitral inflow, lower lateral and mean e’, lower A/a’ ratio, lower strain rate in early diastole, and lower speckle tracking‐derived e/a‐ratio. When comparing the lowest tertiles, patients also had a lower peak filling rate by 4D volumetry, a lower peak early filling fraction (fraction of left ventricular filling during early diastole), and lower velocities in a series of the tissue Doppler‐derived diastolic parameters and blood flow/tissue velocity‐ratios. Conclusion Our study displayed subtle differences in diastolic function between patients and stroke‐free controls, which may play a role in early‐onset cryptogenic stroke. The differences were clearer when the lowest tertiles were compared, suggesting that there is a subgroup of young cryptogenic stroke patients with subclinical heart disease.
- Open Access
- 9 April 2020
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 9 (7) , e014578
Left Atrial Dynamics Is Altered in Young Adults With Cryptogenic Ischemic Stroke: A Case‐Control Study Utilizing Advanced Echocardiography
Background: Ischemic stroke in young individuals often remains cryptogenic. Some of these strokes likely originate from the heart, and atrial fibrosis might be one of the etiological mechanisms. In this pilot study, we investigated whether advanced echocardiography findings of the left atrium ( LA ) of young cryptogenic stroke patients differ from those of stroke‐free controls. Methods and Results: We recruited 30 cryptogenic ischemic stroke patients aged 18 to 49 years and 30 age‐ and sex‐matched stroke‐free controls among participants of the SECRETO (Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers, and Outcome) study ( NCT 01934725). We measured basic left ventricular parameters and detailed measures of the LA , including 4‐dimensional volumetry, speckle tracking epsilon, strain rate, and LA appendix orifice variation. Data were compared as continuous parameters and by tertiles. Compared with controls, stroke patients had smaller LA reservoir volumes (10.2 [interquartile range, 5.4] versus 13.2 [5.4] mL ; P =0.030) and smaller positive epsilon values (17.8 [8.5] versus 20.8 [10.1]; P =0.023). In the tertile analysis, stroke patients had significantly lower left atrial appendage orifice variation (3.88 [0.75] versus 4.35 [0.90] mm; P =0.043), lower LA cyclic volume change (9.2 [2.8] versus 12.8 [3.5] mL ; P =0.023), and lower LA contraction peak strain rate (−1.8 [0.6] versus −2.3 [0.6]; P =0.021). We found no statistically significant differences in left ventricular measures. Conclusions: This preliminary comparison suggests altered LA dynamics in young patients with cryptogenic ischemic stroke, and thus that LA wall pathology might contribute to these strokes. Our results await confirmation in a larger sample.
- 9 April 2020
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 9 (7) , e014578
Open AccessLeft Atrial Dynamics Is Altered in Young Adults With Cryptogenic Ischemic Stroke: A Case‐Control Study Utilizing Advanced Echocardiography
Background: Ischemic stroke in young individuals often remains cryptogenic. Some of these strokes likely originate from the heart, and atrial fibrosis might be one of the etiological mechanisms. In this pilot study, we investigated whether advanced echocardiography findings of the left atrium ( LA ) of young cryptogenic stroke patients differ from those of stroke‐free controls. Methods and Results: We recruited 30 cryptogenic ischemic stroke patients aged 18 to 49 years and 30 age‐ and sex‐matched stroke‐free controls among participants of the SECRETO (Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers, and Outcome) study ( NCT 01934725). We measured basic left ventricular parameters and detailed measures of the LA , including 4‐dimensional volumetry, speckle tracking epsilon, strain rate, and LA appendix orifice variation. Data were compared as continuous parameters and by tertiles. Compared with controls, stroke patients had smaller LA reservoir volumes (10.2 [interquartile range, 5.4] versus 13.2 [5.4] mL ; P =0.030) and smaller positive epsilon values (17.8 [8.5] versus 20.8 [10.1]; P =0.023). In the tertile analysis, stroke patients had significantly lower left atrial appendage orifice variation (3.88 [0.75] versus 4.35 [0.90] mm; P =0.043), lower LA cyclic volume change (9.2 [2.8] versus 12.8 [3.5] mL ; P =0.023), and lower LA contraction peak strain rate (−1.8 [0.6] versus −2.3 [0.6]; P =0.021). We found no statistically significant differences in left ventricular measures. Conclusions: This preliminary comparison suggests altered LA dynamics in young patients with cryptogenic ischemic stroke, and thus that LA wall pathology might contribute to these strokes. Our results await confirmation in a larger sample.