Wei Wei Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wei Wei Zhang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Desheng Sun
Department of Ultrasound, Peking University Shenzhen Hospital, Shenzhen Peking University-The Hong Kong University of Science and Technology Medical Center, Shenzhen 518036, China
1 shared publication Fei Sang
Department of Radiology, Peking University Shenzhen Hospital
1 shared publication- Haiqin Xie
Department of Ultrasound, Peking University Shenzhen Hospital, Shenzhen, China; Peking University Shenzhen Clinical Institute, Shenzhen University Medical College, Shenzhen, China; Peking University Shenzhen Clinical Institute, Shantou University Medical College, Shenzhen, China
1 shared publication - Li Liu
Department of Ultrasound, Peking University Shenzhen Hospital, Shenzhen, 518000, China
1 shared publication - ShuFang Yuan
Department of Ultrasound Imaging, Peking University Shenzhen Hospital, Shenzhen, China
1 shared publication - Xiang Mei Chen
Department of Ultrasound, Peking University Shenzhen Hospital, Lianhua Road 1120, FuTian District, Shenzhen, 518036, Guangdong, China
1 shared publication
Latest Publications
- Open Access
- 10 March 2026
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 16, 1732867
Case Report: imaging features of anaplastic lymphoma kinase-rearranged renal cell carcinoma with a novel DCTN1::ALK fusion
Anaplastic lymphoma kinase (ALK)-rearranged renal cell carcinoma (ALK-RCC) is an extremely rare subtype of RCC, accounting for less than 1% of all cases. Its computed tomography (CT) features remain poorly characterized, hindering preoperative diagnosis. We report the case of a 34-year-old female who presented with painless gross hematuria. Abdominal ultrasound revealed a well-circumscribed, hyperechoic heterogeneous mass in the upper pole of the right kidney. Contrast-enhanced CT demonstrated a solitary, medullary-based hypodense mass with multiple punctate and patchy calcifications and mild heterogeneous enhancement. The patient underwent laparoscopic nephron-sparing surgery with complete resection. Histopathology showed papillary architecture with ISUP/WHO grade 2 atypical cells. Immunohistochemistry was diffusely positive for ALK (clone D5F3). Fluorescence in situ hybridization confirmed ALK rearrangement, and next-generation sequencing identified a novel DCTN1::ALK fusion—the first report of such a fusion in ALK-RCC. Follow-up showed no evidence of recurrence. This case highlights distinctive CT features of ALK-RCC that may raise suspicion in young patients and guide molecular testing. The identification of the DCTN1::ALK fusion expands the molecular landscape of ALK-RCC and supports the potential utility of ALK inhibitors.
- 10 March 2026
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 16, 1732867
Open AccessCase Report: imaging features of anaplastic lymphoma kinase-rearranged renal cell carcinoma with a novel DCTN1::ALK fusion
Anaplastic lymphoma kinase (ALK)-rearranged renal cell carcinoma (ALK-RCC) is an extremely rare subtype of RCC, accounting for less than 1% of all cases. Its computed tomography (CT) features remain poorly characterized, hindering preoperative diagnosis. We report the case of a 34-year-old female who presented with painless gross hematuria. Abdominal ultrasound revealed a well-circumscribed, hyperechoic heterogeneous mass in the upper pole of the right kidney. Contrast-enhanced CT demonstrated a solitary, medullary-based hypodense mass with multiple punctate and patchy calcifications and mild heterogeneous enhancement. The patient underwent laparoscopic nephron-sparing surgery with complete resection. Histopathology showed papillary architecture with ISUP/WHO grade 2 atypical cells. Immunohistochemistry was diffusely positive for ALK (clone D5F3). Fluorescence in situ hybridization confirmed ALK rearrangement, and next-generation sequencing identified a novel DCTN1::ALK fusion—the first report of such a fusion in ALK-RCC. Follow-up showed no evidence of recurrence. This case highlights distinctive CT features of ALK-RCC that may raise suspicion in young patients and guide molecular testing. The identification of the DCTN1::ALK fusion expands the molecular landscape of ALK-RCC and supports the potential utility of ALK inhibitors.
- Open Access
- 11 April 2019
- Published by Springer Nature in Arthritis Research & Therapy
- Vol. 21 (1) , 1-9
A simplified lung ultrasound for the diagnosis of interstitial lung disease in connective tissue disease: a meta-analysis
Interstitial lung disease (ILD) is a common complication of connective tissue disease (CTD) and a leading cause of morbidity and mortality. There are various lung ultrasound (LUS) scoring systems with different lung intercostal spaces (LIS). The purpose of this meta-analysis was to find a simplified LUS method for the assessment of CTD-ILD. We systematically retrieved lung ultrasound diagnostic studies on CTD-ILD in PubMed, Embase, and Web of Science databases. Summary diagnostic accuracy, including sensitivity, specificity, and area under the curve (AUC), was analyzed. Subgroup analysis was conducted according to different LIS and diseases. The 11 studies included in this meta-analysis comprised a total of 487 patients with CTD. The pooled sensitivity and specificity of the LUS were 0.859 (95% confidence interval (CI) 0.812–0.898) and 0.839 (95% CI 0.782–0.886), respectively, illustrating its great value for CTD-ILD diagnosis. In addition, there were six methods to evaluate LIS, including 72, 65, 50, 14, 10, and all LIS. The pooled sensitivity and specificity of 14 LIS were 0.982 (95% CI 0.904–1.000) and 0.875 (95% CI 0.710–0.965), respectively. The pooled positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odd ratio (DOR) of 14 LIS were 7.297 (95% CI 6.050–17.45), 0.029 (95% CI 0.006–0.147), and 292.30 (95% CI 35.53–2403.8), respectively. Moreover, the AUC for systemic sclerosis (SSc) and rheumatoid arthritis (RA) was 0.929 and 0.981, respectively; the DOR for SSc and RA was 42.93 (95% CI 17.75–103.79) and 80.24 (95% CI 8.107–796.09), respectively. We found a modified and simplified method of LUS, by scanning 14 LIS in a short time, which had a very high sensitivity and specificity.
- 11 April 2019
- Published by Springer Nature in Arthritis Research & Therapy
- Vol. 21 (1) , 1-9
Open AccessA simplified lung ultrasound for the diagnosis of interstitial lung disease in connective tissue disease: a meta-analysis
Interstitial lung disease (ILD) is a common complication of connective tissue disease (CTD) and a leading cause of morbidity and mortality. There are various lung ultrasound (LUS) scoring systems with different lung intercostal spaces (LIS). The purpose of this meta-analysis was to find a simplified LUS method for the assessment of CTD-ILD. We systematically retrieved lung ultrasound diagnostic studies on CTD-ILD in PubMed, Embase, and Web of Science databases. Summary diagnostic accuracy, including sensitivity, specificity, and area under the curve (AUC), was analyzed. Subgroup analysis was conducted according to different LIS and diseases. The 11 studies included in this meta-analysis comprised a total of 487 patients with CTD. The pooled sensitivity and specificity of the LUS were 0.859 (95% confidence interval (CI) 0.812–0.898) and 0.839 (95% CI 0.782–0.886), respectively, illustrating its great value for CTD-ILD diagnosis. In addition, there were six methods to evaluate LIS, including 72, 65, 50, 14, 10, and all LIS. The pooled sensitivity and specificity of 14 LIS were 0.982 (95% CI 0.904–1.000) and 0.875 (95% CI 0.710–0.965), respectively. The pooled positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odd ratio (DOR) of 14 LIS were 7.297 (95% CI 6.050–17.45), 0.029 (95% CI 0.006–0.147), and 292.30 (95% CI 35.53–2403.8), respectively. Moreover, the AUC for systemic sclerosis (SSc) and rheumatoid arthritis (RA) was 0.929 and 0.981, respectively; the DOR for SSc and RA was 42.93 (95% CI 17.75–103.79) and 80.24 (95% CI 8.107–796.09), respectively. We found a modified and simplified method of LUS, by scanning 14 LIS in a short time, which had a very high sensitivity and specificity.