Alihan Bozoglan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alihan Bozoglan has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Serkan Dundar
Firat University, Faculty of Dentistry, Department of Peridontology, Elazig, Turkiye
11 shared publications - Erhan Cahit Ozcan
Firat University, Faculty of Medicine, Department of Plastic, Reconstructive and Aesthetic Surgery, Elazig, Türkiye
4 shared publications - Tuba Talo Yildirim
Department of Periodontology, Faculty of Dentistry, Firat University, Turkey
4 shared publications - Mehmet Gül
Faculty of Dentistry, Department of Periodontology, Nevşehir Hacı Bektaş Veli University, 2000 Evler Mahallesi, Zübeyde Hanım Caddesi, 50300, Nevşehir, Turkey
3 shared publications - Murat Tanrisever
Firat University, Faculty of Veterinary Medicine, Department of Surgery, Elazig, Turkiye
3 shared publications - Umit Koray Can
Turkish Jockey Club Elazig Racecourse Horse Hospital, Elazig, Turkiye
3 shared publications
Latest Publications
- 4 December 2025
- Published by Universidad del Zulia in Revista Científica de la Facultad de Ciencias Veterinarias
- Vol. 36 (1)
Investigation of the effect of Arginine Silicate Inositol complex on the osseointegration level of titanium implants
Arginine silicate inositol complex is a material that increases bone mineral density and the amount of collagen in vascular tissue. The aim of this study was to investigate the effect of the Arginine silicate inositol complex, administered orally via gavage, on the osseointegration level of titanium implants in the tibiae of rats. The experimental animals were divided into four groups a control group, which had no implants or further treatment; a control–implant group, which had implants placed only in the tibia bone but no further treatment; an, Arginine silicate inositol – administered group, which had no implants but was administered Arginine silicate inositol; and an Arginine silicate inositol – implant group, which had both implants placed and Arginine silicate inositol administered. In serum samples obtained from the rats, associated with bone tissue; alkaline phosphatase, osteocalcin, calcium, phosphorus, associated with liver function; alanine aminotransferase, aspartate aminotransferase were analyzed using biochemical methods. Densitometric evaluations were performed on the jaw and femur bones. The titanium screws were removed along with the surrounding bone tissue for histological evaluation. Non Parametric Tests were used the data analysis: Mann–Whitney U (between two groups), Kruskal–Wallis and Dunn test (between four groups), bone–implant connection and thread fill levels did not show a statistically significant difference among the groups (P>0.05). The levels of calcium, alkaline phosphatase, osteocalcin, alanine aminotransferase, aspartate aminotransferase, femur bone mineral density and phosphorus also did not show a statistically significant difference among the groups (P>0.05). The differences in levels of jaw bone mineral density were statistically significant among the groups (P<0.05). Thus, it can be concluded that the Arginine silicate inositol complex may increase jaw bone mineral density, and bone–implant integration.
- 4 December 2025
- Published by Universidad del Zulia in Revista Científica de la Facultad de Ciencias Veterinarias
- Vol. 36 (1)
Investigation of the effect of Arginine Silicate Inositol complex on the osseointegration level of titanium implants
Arginine silicate inositol complex is a material that increases bone mineral density and the amount of collagen in vascular tissue. The aim of this study was to investigate the effect of the Arginine silicate inositol complex, administered orally via gavage, on the osseointegration level of titanium implants in the tibiae of rats. The experimental animals were divided into four groups a control group, which had no implants or further treatment; a control–implant group, which had implants placed only in the tibia bone but no further treatment; an, Arginine silicate inositol – administered group, which had no implants but was administered Arginine silicate inositol; and an Arginine silicate inositol – implant group, which had both implants placed and Arginine silicate inositol administered. In serum samples obtained from the rats, associated with bone tissue; alkaline phosphatase, osteocalcin, calcium, phosphorus, associated with liver function; alanine aminotransferase, aspartate aminotransferase were analyzed using biochemical methods. Densitometric evaluations were performed on the jaw and femur bones. The titanium screws were removed along with the surrounding bone tissue for histological evaluation. Non Parametric Tests were used the data analysis: Mann–Whitney U (between two groups), Kruskal–Wallis and Dunn test (between four groups), bone–implant connection and thread fill levels did not show a statistically significant difference among the groups (P>0.05). The levels of calcium, alkaline phosphatase, osteocalcin, alanine aminotransferase, aspartate aminotransferase, femur bone mineral density and phosphorus also did not show a statistically significant difference among the groups (P>0.05). The differences in levels of jaw bone mineral density were statistically significant among the groups (P<0.05). Thus, it can be concluded that the Arginine silicate inositol complex may increase jaw bone mineral density, and bone–implant integration.
- Open Access
- 6 July 2025
- Published by Universidad del Zulia in Revista Científica de la Facultad de Ciencias Veterinarias
- Vol. 35 (3) , 6
Evaluation of Osseointegration of Trabecular Titanium Implants Produced with Porous Metal Technology: An Experimental Study
Trabecular titanium (TM) implants produced with porous metal technology are used in dental implant treatments due to their resemblance to cancellous bone and their physical and mechanical properties. The objective of this study was to perform a histological assessment and comparison of the bone–implant contact (BIC) rates between trabecular metal (TM) implants and conventionally machined-surface implants in rat femurThe study was conducted using twenty healthy adult male Sprague-Dawley rats, which were randomly allo- cated into two equal groups: one serving as the control group and the other receiving trabecular metal (TM) implants. All im- plants were surgically placed into the right femora of the rats. A curved incision approximately 10-15 mm long was made on the anterolateral aspect of the right knee. The knee joint cap- sule, formed by the femur and tibia, was dissected. Following this procedure, the patella was subluxed, exposing the inter- condylar fossa of the femur for implant placement. Following a 4-week healing period, undecalcified histomorphometric analyses of the samples were performed. BIC (%) measure- ments were conducted in the histomorphometric evaluations. Group comparisons were analyzed using the Student’s t-test. TM implants exhibited an average BIC of 37.13%, while stan- dard cylindrical implants had an average BIC of 29.13%, with a significant statistical difference between the two groups (P < 0.05). Within the limitation of this study titanium implants produced with TM technology have higher percentages of BIC than standard cylindrical titanium implants.
- 6 July 2025
- Published by Universidad del Zulia in Revista Científica de la Facultad de Ciencias Veterinarias
- Vol. 35 (3) , 6
Open AccessEvaluation of Osseointegration of Trabecular Titanium Implants Produced with Porous Metal Technology: An Experimental Study
Trabecular titanium (TM) implants produced with porous metal technology are used in dental implant treatments due to their resemblance to cancellous bone and their physical and mechanical properties. The objective of this study was to perform a histological assessment and comparison of the bone–implant contact (BIC) rates between trabecular metal (TM) implants and conventionally machined-surface implants in rat femurThe study was conducted using twenty healthy adult male Sprague-Dawley rats, which were randomly allo- cated into two equal groups: one serving as the control group and the other receiving trabecular metal (TM) implants. All im- plants were surgically placed into the right femora of the rats. A curved incision approximately 10-15 mm long was made on the anterolateral aspect of the right knee. The knee joint cap- sule, formed by the femur and tibia, was dissected. Following this procedure, the patella was subluxed, exposing the inter- condylar fossa of the femur for implant placement. Following a 4-week healing period, undecalcified histomorphometric analyses of the samples were performed. BIC (%) measure- ments were conducted in the histomorphometric evaluations. Group comparisons were analyzed using the Student’s t-test. TM implants exhibited an average BIC of 37.13%, while stan- dard cylindrical implants had an average BIC of 29.13%, with a significant statistical difference between the two groups (P < 0.05). Within the limitation of this study titanium implants produced with TM technology have higher percentages of BIC than standard cylindrical titanium implants.
- Open Access
- 6 July 2025
- Published by Universidad del Zulia in Revista Científica de la Facultad de Ciencias Veterinarias
- Vol. 35 (3) , 6
Biomechanical investigation of the effect of Vitamin C supplementation on Osseointegration of titanium implants in rat (Rattus norvegicus) tibia
In this study, it was aimed to evaluate some possible effects of vitamin C supplementation on the osseointegration process implants placed in rat tibias. Thirty 3-month-old female Spraque Dawley rats (Rattus norvegicus) were divided into 3 groups. In all groups, the corticocancellous part of the the metaphysis of the right tibia bones were surgically reached. Monocortical implant sockets were created by surgical methods under serum cooling, and then titanium implants with 2.5 mm diameter and 4 mm long titanium were integrated on these bone sockets. Group Sham (Control) (n=10): No additional application was made during the experimental process. Group C1 (n=10): 5 mg/kg vitamin C was given to the rats with oral gavage application in three days a week for four weeks of experimental process. Group C2 (n=10): 10 mg/kg vitamin C was given to the rats with oral gavage application in three days a week for four weeks of experimental process. At the end of the four- week experimental setup, all rats were sacrificed and the experimental process was completed. The implants integrated in the tibias of all rats were collected with the surrounding bone tissue after removing the soft tissues for biomechanical analysis. Biomechanical reverse torque analysis was applied to all implants. Statistical analysis of the obtained data; Kruskall- Wallis test, no statistically significant difference was detected between the control and experimental groups (P>0,05). In conclusion, 5 and 10mg/kg vitamin C supplementation has no positive or negative effects on osseointegration. This situaiton can be explained in two ways; the first, the dosages of vitamin C used in this study is not sufficient to create an effect. Second, the endogenous synthesis of this vitamin is enough even though under these stress conditions.
- 6 July 2025
- Published by Universidad del Zulia in Revista Científica de la Facultad de Ciencias Veterinarias
- Vol. 35 (3) , 6
Open AccessBiomechanical investigation of the effect of Vitamin C supplementation on Osseointegration of titanium implants in rat (Rattus norvegicus) tibia
In this study, it was aimed to evaluate some possible effects of vitamin C supplementation on the osseointegration process implants placed in rat tibias. Thirty 3-month-old female Spraque Dawley rats (Rattus norvegicus) were divided into 3 groups. In all groups, the corticocancellous part of the the metaphysis of the right tibia bones were surgically reached. Monocortical implant sockets were created by surgical methods under serum cooling, and then titanium implants with 2.5 mm diameter and 4 mm long titanium were integrated on these bone sockets. Group Sham (Control) (n=10): No additional application was made during the experimental process. Group C1 (n=10): 5 mg/kg vitamin C was given to the rats with oral gavage application in three days a week for four weeks of experimental process. Group C2 (n=10): 10 mg/kg vitamin C was given to the rats with oral gavage application in three days a week for four weeks of experimental process. At the end of the four- week experimental setup, all rats were sacrificed and the experimental process was completed. The implants integrated in the tibias of all rats were collected with the surrounding bone tissue after removing the soft tissues for biomechanical analysis. Biomechanical reverse torque analysis was applied to all implants. Statistical analysis of the obtained data; Kruskall- Wallis test, no statistically significant difference was detected between the control and experimental groups (P>0,05). In conclusion, 5 and 10mg/kg vitamin C supplementation has no positive or negative effects on osseointegration. This situaiton can be explained in two ways; the first, the dosages of vitamin C used in this study is not sufficient to create an effect. Second, the endogenous synthesis of this vitamin is enough even though under these stress conditions.
- Open Access
- 4 April 2025
- Published by Universidad del Zulia in Revista Científica de la Facultad de Ciencias Veterinarias
- Vol. 35 (2) , 6
Effects of local enemal matrix protein on osseointegration of different surface Titanium implants
The aim of this study is to investigate the osseointegration levels of implants with different surfaces locally applied with enamel matrix protein by biomechanical methods. Thirty adult female Spraque Dawley rats weighing 300–350 g were included in the study as subjects. The rats were divided into 3 groups with 10 rats in each group: Machined Surface Group (n = 10), Sandblasted Large Acid Grid (SLA) Surface Group (n = 10) and Resorbable Blasting Material (RBM) Surface Group (n = 10). Titanium implants were surgically placed in the right tibias of the rats with sterile physiological serum cooling. Immediately before the implants were placed, local enamel matrix protein was applied to the prepared sockets and then the implants were placed. The rats were euthanized after waiting for osseointegration for four weeks and the implants were taken with the surrounding bone tissues after the soft tissues were removed. The bone–implant contact of all implants was analyzed by biomechanical method and recorded in Newton·cm-1 (N·cm-1). When the obtained biomechanical data were examined, the average bone–implant contact value was found to be 2.24 ± 0.67 (N·cm-1) in machined surface implants, 4.5 ± 1.36 (N·cm-1) in SLA surface implants and 3.24 ± 0.94 (N·cm-1) in RBM surface implants. A statistically difference was detected between machined surface implants and SLA surface implants (P<0.05; P=0.02). It can be stated that local enamel matrix protein application may increase bone–implant connection in SLA surface implants.
- 4 April 2025
- Published by Universidad del Zulia in Revista Científica de la Facultad de Ciencias Veterinarias
- Vol. 35 (2) , 6
Open AccessEffects of local enemal matrix protein on osseointegration of different surface Titanium implants
The aim of this study is to investigate the osseointegration levels of implants with different surfaces locally applied with enamel matrix protein by biomechanical methods. Thirty adult female Spraque Dawley rats weighing 300–350 g were included in the study as subjects. The rats were divided into 3 groups with 10 rats in each group: Machined Surface Group (n = 10), Sandblasted Large Acid Grid (SLA) Surface Group (n = 10) and Resorbable Blasting Material (RBM) Surface Group (n = 10). Titanium implants were surgically placed in the right tibias of the rats with sterile physiological serum cooling. Immediately before the implants were placed, local enamel matrix protein was applied to the prepared sockets and then the implants were placed. The rats were euthanized after waiting for osseointegration for four weeks and the implants were taken with the surrounding bone tissues after the soft tissues were removed. The bone–implant contact of all implants was analyzed by biomechanical method and recorded in Newton·cm-1 (N·cm-1). When the obtained biomechanical data were examined, the average bone–implant contact value was found to be 2.24 ± 0.67 (N·cm-1) in machined surface implants, 4.5 ± 1.36 (N·cm-1) in SLA surface implants and 3.24 ± 0.94 (N·cm-1) in RBM surface implants. A statistically difference was detected between machined surface implants and SLA surface implants (P<0.05; P=0.02). It can be stated that local enamel matrix protein application may increase bone–implant connection in SLA surface implants.
- Open Access
- 30 April 2022
- Published by Zeus Publishing in International Dental Research
- Vol. 12 (1) , 27-33
Biomechanic and biochemical analysis of the effects of local Ankaferd Blood Stopper® application on osseointegration of titanium implants
Aim: Investigations into Ankaferd Blood Stopper® (ABS) on bone healing have revealed positive bone regeneration effects. The exact mechanism of this positive bone tissue metabolism effect is unknown. This study’s aim is a biomechanic and biochemical investigation of the effects of local ABS application on the osseointegration of titanium implants. Methodology: Sprague Dawley rats were divided into four groups of ten rats each. The control group (n=20) received no treatment during the experimental period, while the ABS group (n=20) had ABS applied locally during the surgical application of the titanium implant before insertion into the bone sockets. After 2 (controls n=10 and ABS n=10) and 4 weeks (controls n=10 and ABS n=10) experimental periods, the rats were sacrificed and implants with surrounding bone tissues were removed for reverse torque analysis (Newton), blood sample collection, and biochemical analysis. Results: The biomechanic bone implant contact ratio detected was higher in week 4 than in week 2 in the ABS group (p<0, 05). Lower phosphor levels were detected in the ABS group than in the 4-week controls (p<0, 05). Conclusion: According to the biomechanical parameters, ABS is more effective after four weeks than after two weeks when locally applied. How to cite this article: Özcan EC, Gül M, Tanık A, Yıldırım TT, Özkan M, Bozoğlan A, Özdemir HE, Dündar S. Biomechanic and biochemical analysis of the effects of local Ankaferd Blood Stopper® application on osseointegration of titanium implants. Int Dent Res 2022;12(1):27-33. https://doi.org/10.5577/intdentres.2022.vol12.no1.5 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
- 30 April 2022
- Published by Zeus Publishing in International Dental Research
- Vol. 12 (1) , 27-33
Open AccessBiomechanic and biochemical analysis of the effects of local Ankaferd Blood Stopper® application on osseointegration of titanium implants
Aim: Investigations into Ankaferd Blood Stopper® (ABS) on bone healing have revealed positive bone regeneration effects. The exact mechanism of this positive bone tissue metabolism effect is unknown. This study’s aim is a biomechanic and biochemical investigation of the effects of local ABS application on the osseointegration of titanium implants. Methodology: Sprague Dawley rats were divided into four groups of ten rats each. The control group (n=20) received no treatment during the experimental period, while the ABS group (n=20) had ABS applied locally during the surgical application of the titanium implant before insertion into the bone sockets. After 2 (controls n=10 and ABS n=10) and 4 weeks (controls n=10 and ABS n=10) experimental periods, the rats were sacrificed and implants with surrounding bone tissues were removed for reverse torque analysis (Newton), blood sample collection, and biochemical analysis. Results: The biomechanic bone implant contact ratio detected was higher in week 4 than in week 2 in the ABS group (p<0, 05). Lower phosphor levels were detected in the ABS group than in the 4-week controls (p<0, 05). Conclusion: According to the biomechanical parameters, ABS is more effective after four weeks than after two weeks when locally applied. How to cite this article: Özcan EC, Gül M, Tanık A, Yıldırım TT, Özkan M, Bozoğlan A, Özdemir HE, Dündar S. Biomechanic and biochemical analysis of the effects of local Ankaferd Blood Stopper® application on osseointegration of titanium implants. Int Dent Res 2022;12(1):27-33. https://doi.org/10.5577/intdentres.2022.vol12.no1.5 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
- Open Access
- 17 January 2022
- Published by Journal of Health Sciences and Medicine in Journal of Health Sciences and Medicine
- Vol. 5 (1) , 144-149
The effects of dual anti-platelet therapy on titanium implant osseointegration: an experimental study
Aim: In this study, we aim to investigate the effect of dual anti-platelet agents on osseointegration by studying a sample of rats with titanium implants in their tibias. Material and Method: The titanium implants were placed surgically to the left tibias of a sample group of 50 rats. After implantation, the rats were randomly divided into five groups: acetylsalicylic acid (ASA) (n =10), treated with 20 mg/kg of ASA; ASA+ clopidogrel (CLPD) (n=10), treated with 20 mg/kg of ASA and 30 mg/kg of CLPD; ASA+ prasugrel (PRSG) (n=10), treated with 20 mg/kg of ASA and 15 mg/kg of PRSG; ASA+ ticagrelor (TCGR) (n=10), treated with 20 mg/kg of ASA and 300 mg/kg of TCGR; and a control group (CNT) (n =10) received no further treatment following implant surgery. The experimental period lasted four weeks, during which all medications were administered with oral gavage. Concluding the experimental period, the animals were euthanized, and researchers collected blood serums and the implants, along with some surrounding bones, from each rats. Results: Bone implant connection and bone filling ratios (%) were observed histologically and documented. The bone-implant connection and bone filling ratios of the rats do not show statistically significant differences between the groups examined (P>0.05). Conclusion: In this study, it was shown that there was no bone healing problem between the antiaggregant given groups and between these groups and the control group. Too many people have to take single or double antiaggregant due to many diseases. We think that it is an important study in terms of knowing that bone healing will not be negatively affected when dental implants or other bone prosthesis procedures are applied to these patients. The results of this study should be supported by further research.
- 17 January 2022
- Published by Journal of Health Sciences and Medicine in Journal of Health Sciences and Medicine
- Vol. 5 (1) , 144-149
Open AccessThe effects of dual anti-platelet therapy on titanium implant osseointegration: an experimental study
Aim: In this study, we aim to investigate the effect of dual anti-platelet agents on osseointegration by studying a sample of rats with titanium implants in their tibias. Material and Method: The titanium implants were placed surgically to the left tibias of a sample group of 50 rats. After implantation, the rats were randomly divided into five groups: acetylsalicylic acid (ASA) (n =10), treated with 20 mg/kg of ASA; ASA+ clopidogrel (CLPD) (n=10), treated with 20 mg/kg of ASA and 30 mg/kg of CLPD; ASA+ prasugrel (PRSG) (n=10), treated with 20 mg/kg of ASA and 15 mg/kg of PRSG; ASA+ ticagrelor (TCGR) (n=10), treated with 20 mg/kg of ASA and 300 mg/kg of TCGR; and a control group (CNT) (n =10) received no further treatment following implant surgery. The experimental period lasted four weeks, during which all medications were administered with oral gavage. Concluding the experimental period, the animals were euthanized, and researchers collected blood serums and the implants, along with some surrounding bones, from each rats. Results: Bone implant connection and bone filling ratios (%) were observed histologically and documented. The bone-implant connection and bone filling ratios of the rats do not show statistically significant differences between the groups examined (P>0.05). Conclusion: In this study, it was shown that there was no bone healing problem between the antiaggregant given groups and between these groups and the control group. Too many people have to take single or double antiaggregant due to many diseases. We think that it is an important study in terms of knowing that bone healing will not be negatively affected when dental implants or other bone prosthesis procedures are applied to these patients. The results of this study should be supported by further research.
- 1 October 2021
- Published by Elsevier in Journal of Oral Biology and Craniofacial Research
- Vol. 11 (4) , 524-528
Effects of local application of the ankaferd blood stopper on osseointegration in three different surface titanium implants
- 1 October 2021
- Published by Elsevier in Journal of Oral Biology and Craniofacial Research
- Vol. 11 (4) , 524-528
Effects of local application of the ankaferd blood stopper on osseointegration in three different surface titanium implants
- 27 August 2021
- Published by Harran Universitesi Tip Fakultesi Dergisi in Harran Üniversitesi Tıp Fakültesi Dergisi
- Vol. 18 (2) , 176-180
Evaluation of the Effects of Topical Vitamin D on Osseointegration of Titanium Implants: An Experimental Study
Background: The aim of this study was to evaluate the effects of topical vitamin D to on osseointegration when applied to the surface of titanium implants. Material and Metods: Twenty male Spraque-Dawley rats were used in this study in a 4-week experimental period. 4 rats died during the experiments. The rats were divided into 2 groups: a test group and control group. Sixteen sandblasted and acid-etched implants were integrated surgically in the metaphyseal part of rat femurs after patella dissection. Prior to integration, the implants, which were 3.2 mm in diameter and 8 mm in length, were submerged in a 10% vitamin D solution in the test group. No treatment was applied in the control group. After the 4-week experimental period, the rats were sacrificed, and the implants were removed with surrounding bone tissue. Specimens were fixed for 7 days in a 10% formaldehyde solution. Bone implant contact (BIC) ratios were determined after using non-decalcified histological methods. Results: In the experiment, 2 samples were removed because they were not suitable. No statistically significant differences were found for BIC ratios between the test (n = 7) and control group (n = 7) implants (P> 0.05). Conclusion: It was concluded, within the limitations of this animal study, that topical vitamin D application on implant surfaces does not affect BIC ratios.
- 27 August 2021
- Published by Harran Universitesi Tip Fakultesi Dergisi in Harran Üniversitesi Tıp Fakültesi Dergisi
- Vol. 18 (2) , 176-180
Evaluation of the Effects of Topical Vitamin D on Osseointegration of Titanium Implants: An Experimental Study
Background: The aim of this study was to evaluate the effects of topical vitamin D to on osseointegration when applied to the surface of titanium implants. Material and Metods: Twenty male Spraque-Dawley rats were used in this study in a 4-week experimental period. 4 rats died during the experiments. The rats were divided into 2 groups: a test group and control group. Sixteen sandblasted and acid-etched implants were integrated surgically in the metaphyseal part of rat femurs after patella dissection. Prior to integration, the implants, which were 3.2 mm in diameter and 8 mm in length, were submerged in a 10% vitamin D solution in the test group. No treatment was applied in the control group. After the 4-week experimental period, the rats were sacrificed, and the implants were removed with surrounding bone tissue. Specimens were fixed for 7 days in a 10% formaldehyde solution. Bone implant contact (BIC) ratios were determined after using non-decalcified histological methods. Results: In the experiment, 2 samples were removed because they were not suitable. No statistically significant differences were found for BIC ratios between the test (n = 7) and control group (n = 7) implants (P> 0.05). Conclusion: It was concluded, within the limitations of this animal study, that topical vitamin D application on implant surfaces does not affect BIC ratios.
- 28 April 2021
- Published by Harran Universitesi Tip Fakultesi Dergisi in Harran Üniversitesi Tıp Fakültesi Dergisi
- Vol. 18 (1) , 54-58
Enamel Matris Türevinin (Emdogain®) Dental İmplant Osseointegrasyonu Üzerindeki Etkilerinin Değerlendirilmesi
Amaç: Bu çalışmanın amacı, Enamel matris türevinin (Emdogain®) kemik grefti ile karıştırılarak defekt oluşturulan bölgeye uygulanmasından sonra yeni kemik rejenerasyonunun kemik implant kaynaşmasına etkisinin değerlendirilmesidir. Materyal ve metod: Deneyde toplamda 20 adet sprague dawley rat kullanılmıştır. Herbir grupta 10 adet rat bulunmaktadır. Ratlar, % 55’lik nem ve 22 ±2°C sıcaklık kontrollü bulunan odada bulundurulmuştur. Ayrıca 12 saat aydınlık 12 saat karanlık döngüsünde tabi tutulmuştur. Deneklerin sağ tibiya kemiklerinin metafiziyel kısımlarındaki kortikokansellöz kemiğine kaviteler açıldı. Bu kavitelere 2.5 mm çapında 4 mm uzunluğundaki titanyum implantlar yerleştirildi ve boyun bölgesinde implant boyunun 2 mm’sine tekabül edecek şekilde kontrol grubuna sadece kemik defekti yerleştirildi. Deney grubuna ise kemik grefti ve Enamel matris türevinin (Emdogain®) yerleştirildi. 8 hafta sonra denekler sakrifiye edildi. Bulgular: Yapılan analizler sonucunda kemik implant kaynaşması emdogain uygulanan grupta yüksek bulunmasına rağmen istatistiksel olarak anlamlı bir fark elde edilememiştir. Aynı şekilde glukoz, ast, alt, alp, üre, kreatinin ve kalsiyum seviyeleri değerlendirilmiş ve istatistiksel olarak anlamlı bir fark elde edilememiştir. Fakat fosfor seviyesinde deney grubunda anlamlı derece bir düşme tespit edilmiştir (p < 0.05). Sonuç: Emdogain uygulaması greft materyalinin etkisini artırmaktadır ve aynı zamanda implant kemik kontağına olumlu etkisi bulunmaktadır. Fakat 8 haftalık kısa iyileşme periyodunda etkisi sınırlı olmaktadır. Emdogain uygulamasının etkisinin kesin olarak anlaşılması için uzun zamanlı çalışmalara ihtiyaç vardır.
- 28 April 2021
- Published by Harran Universitesi Tip Fakultesi Dergisi in Harran Üniversitesi Tıp Fakültesi Dergisi
- Vol. 18 (1) , 54-58
Enamel Matris Türevinin (Emdogain®) Dental İmplant Osseointegrasyonu Üzerindeki Etkilerinin Değerlendirilmesi
Amaç: Bu çalışmanın amacı, Enamel matris türevinin (Emdogain®) kemik grefti ile karıştırılarak defekt oluşturulan bölgeye uygulanmasından sonra yeni kemik rejenerasyonunun kemik implant kaynaşmasına etkisinin değerlendirilmesidir. Materyal ve metod: Deneyde toplamda 20 adet sprague dawley rat kullanılmıştır. Herbir grupta 10 adet rat bulunmaktadır. Ratlar, % 55’lik nem ve 22 ±2°C sıcaklık kontrollü bulunan odada bulundurulmuştur. Ayrıca 12 saat aydınlık 12 saat karanlık döngüsünde tabi tutulmuştur. Deneklerin sağ tibiya kemiklerinin metafiziyel kısımlarındaki kortikokansellöz kemiğine kaviteler açıldı. Bu kavitelere 2.5 mm çapında 4 mm uzunluğundaki titanyum implantlar yerleştirildi ve boyun bölgesinde implant boyunun 2 mm’sine tekabül edecek şekilde kontrol grubuna sadece kemik defekti yerleştirildi. Deney grubuna ise kemik grefti ve Enamel matris türevinin (Emdogain®) yerleştirildi. 8 hafta sonra denekler sakrifiye edildi. Bulgular: Yapılan analizler sonucunda kemik implant kaynaşması emdogain uygulanan grupta yüksek bulunmasına rağmen istatistiksel olarak anlamlı bir fark elde edilememiştir. Aynı şekilde glukoz, ast, alt, alp, üre, kreatinin ve kalsiyum seviyeleri değerlendirilmiş ve istatistiksel olarak anlamlı bir fark elde edilememiştir. Fakat fosfor seviyesinde deney grubunda anlamlı derece bir düşme tespit edilmiştir (p < 0.05). Sonuç: Emdogain uygulaması greft materyalinin etkisini artırmaktadır ve aynı zamanda implant kemik kontağına olumlu etkisi bulunmaktadır. Fakat 8 haftalık kısa iyileşme periyodunda etkisi sınırlı olmaktadır. Emdogain uygulamasının etkisinin kesin olarak anlaşılması için uzun zamanlı çalışmalara ihtiyaç vardır.
- Open Access
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 34, e008
Effects of restraint stress and high-fat diet on osseointegration of titanium implants: an experimental study
This study aimed to investigate the effects of chronic restraint stress (RS) and a high-fat diet (HFD) on the osseointegration of titanium implants in a rat model. After the surgical insertion of titanium implants into the metaphysis of the tibial bone, the rats were randomly divided into four equal groups (n = 8 each): control (CNT), restraint stress (RS), high-fat diet (HFD), and restraint stress plus high fat diet (RS-HFD). CNT: Rats received no further treatment during the 92-day experimental period. RS: Stress was applied to the rats beginning from two days after the implant surgery for one hour per day for the first 30 days, two hours per day for the next 30 days, and three hours per day for the last 30 days. HFD: Rats were fed a HFD for the following 90 days starting two days after surgery. RS-HFD: Rats were fed a HFD and RS was applied to rats for the following 90 days, starting two days after surgery. At the end of the experimental period, the rats were euthanized, and the implants and surrounding bone tissues were removed for histological analysis. Statistical analysis was performed by one way ANOVA and Bonferrroni tests. There were no significant differences in the bone-implant connection levels between the groups (p > 0.05), but in the HFD and RS-HFD groups, the bone filling ratios were found to be lower compared with the controls (p < 0.05) The data analyzed in this study suggest that an HFD with or without chronic RS adversely affected bone tissue in the rats during the 90-day osseointegration period.
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 34, e008
Open AccessEffects of restraint stress and high-fat diet on osseointegration of titanium implants: an experimental study
This study aimed to investigate the effects of chronic restraint stress (RS) and a high-fat diet (HFD) on the osseointegration of titanium implants in a rat model. After the surgical insertion of titanium implants into the metaphysis of the tibial bone, the rats were randomly divided into four equal groups (n = 8 each): control (CNT), restraint stress (RS), high-fat diet (HFD), and restraint stress plus high fat diet (RS-HFD). CNT: Rats received no further treatment during the 92-day experimental period. RS: Stress was applied to the rats beginning from two days after the implant surgery for one hour per day for the first 30 days, two hours per day for the next 30 days, and three hours per day for the last 30 days. HFD: Rats were fed a HFD for the following 90 days starting two days after surgery. RS-HFD: Rats were fed a HFD and RS was applied to rats for the following 90 days, starting two days after surgery. At the end of the experimental period, the rats were euthanized, and the implants and surrounding bone tissues were removed for histological analysis. Statistical analysis was performed by one way ANOVA and Bonferrroni tests. There were no significant differences in the bone-implant connection levels between the groups (p > 0.05), but in the HFD and RS-HFD groups, the bone filling ratios were found to be lower compared with the controls (p < 0.05) The data analyzed in this study suggest that an HFD with or without chronic RS adversely affected bone tissue in the rats during the 90-day osseointegration period.