Udaykumar R. Yaragatti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Udaykumar R. Yaragatti has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- N. Sandeep
Department of Electrical Engineering, Malaviya National Institute of Technology Jaipur, Jaipur, India
13 shared publications Santosh Kumar
School of Electrical and Computing Engineering, Adama Science and Technology University, Adama, Ethiopia
7 shared publications- Abdul Rahiman Beig
Department of Electrical Engineering, Advanced Power and Energy Center (APEC), Khalifa University, Abu Dhabi, United Arab Emirates
5 shared publications - Jagabar Sathik Mohamed Ali
Department of Electrical and Electronics Engineering, SRM Institute of Science and Technology, Chengalpattu, Tamil Nadu, India
5 shared publications - Rajashekar P. Mandi
REVA University
5 shared publications - Arun Kumar Verma
Department of Electrical Engineering, Indian Institute of Technology, Jammu, India
4 shared publications
Latest Publications
- 19 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 4 (1) , 317-326
An Integrated Single-Stage Single-Switch Topology With Reduced Nonlinear Components for LED
This article presents an integrated single-stage single-switch (4S) ac–dc system for LED delivering a high input power factor (IPF) and regulated output. The proposed topology integrates a power factor correction (PFC) converter with a high-frequency dc–dc converter, driven by a modified front-end single-phase Vienna rectifier. The integration results in a single switch prototype, thus decreasing the cost and complexity of the control circuit. The use of fewer diodes in the front-end rectifier reduces the nonlinearity in the proposed topology. First-stage filter capacitors offer a better input dynamics to the PFC stage. The proposed (4S) prototype offers less component counts and minimal input current harmonics. The theoretical and mathematical analysis of the proposed topology is presented. Finally, the proposed (4S) ac–dc system analysis and simulation results have been verified with a 50 W/60 V prototype depicting an IPF of 0.997, total harmonic distortion (THD) of 3.96%, and an efficiency of 90.8%. The presented experimental results coincided with the analysis and comply with IEC61000-3-2 standards.
- 19 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 4 (1) , 317-326
An Integrated Single-Stage Single-Switch Topology With Reduced Nonlinear Components for LED
This article presents an integrated single-stage single-switch (4S) ac–dc system for LED delivering a high input power factor (IPF) and regulated output. The proposed topology integrates a power factor correction (PFC) converter with a high-frequency dc–dc converter, driven by a modified front-end single-phase Vienna rectifier. The integration results in a single switch prototype, thus decreasing the cost and complexity of the control circuit. The use of fewer diodes in the front-end rectifier reduces the nonlinearity in the proposed topology. First-stage filter capacitors offer a better input dynamics to the PFC stage. The proposed (4S) prototype offers less component counts and minimal input current harmonics. The theoretical and mathematical analysis of the proposed topology is presented. Finally, the proposed (4S) ac–dc system analysis and simulation results have been verified with a 50 W/60 V prototype depicting an IPF of 0.997, total harmonic distortion (THD) of 3.96%, and an efficiency of 90.8%. The presented experimental results coincided with the analysis and comply with IEC61000-3-2 standards.
- 3 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (4) , 4923-4931
Compact Quadratic Boost Switched-Capacitor Inverter
This article presents a new topology for a single-stage nine-level (9L) switched-capacitor inverter. The structure of the proposed topology is not only simple but also compact. The proposed topology is developed with self-voltage balancing and a low number of power components. The output voltage ( vo ) gain is four times higher than the input voltage ( v in ). Each mode of operation is discussed with a detailed current path. The conventional sinusoidal pulsewidth modulation technique is used to generate the gate pulses. Next, the experimental results are obtained from a 1 kW prototype setup. The proposed topology is tested under different scenarios such as load change, input voltage changes, and modulation variations. Both simulation and experimental results have good agreement in terms of efficiency. Finally, a detailed comparative study is performed with other recent 9L inverters to prove the merits of the proposed topology.
- 3 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (4) , 4923-4931
Compact Quadratic Boost Switched-Capacitor Inverter
This article presents a new topology for a single-stage nine-level (9L) switched-capacitor inverter. The structure of the proposed topology is not only simple but also compact. The proposed topology is developed with self-voltage balancing and a low number of power components. The output voltage ( vo ) gain is four times higher than the input voltage ( v in ). Each mode of operation is discussed with a detailed current path. The conventional sinusoidal pulsewidth modulation technique is used to generate the gate pulses. Next, the experimental results are obtained from a 1 kW prototype setup. The proposed topology is tested under different scenarios such as load change, input voltage changes, and modulation variations. Both simulation and experimental results have good agreement in terms of efficiency. Finally, a detailed comparative study is performed with other recent 9L inverters to prove the merits of the proposed topology.
- 1 January 2022
- Published by Inderscience Publishers in International Journal of Power Electronics
- Vol. 15 (3/4) , 473
Design and implementation of constant flux controller for VSI assisted SEIG feeding induction motor pump
In small scale, stand-alone, wind-power generation employing self excited induction generator (SEIG), water pumping using an induction motor is a typical application. In this paper, a simple voltag...
- 1 January 2022
- Published by Inderscience Publishers in International Journal of Power Electronics
- Vol. 15 (3/4) , 473
Design and implementation of constant flux controller for VSI assisted SEIG feeding induction motor pump
In small scale, stand-alone, wind-power generation employing self excited induction generator (SEIG), water pumping using an induction motor is a typical application. In this paper, a simple voltag...
- 28 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (6) , 6237-6245
A Five-Level Transformer-Less Inverter With Self-Voltage Balancing and Boosting Ability
Transformer-less inverters (TIs) are widely used in photovoltaic (PV) applications owing to their low cost and high efficiency. However, the combined effect of high-frequency common mode voltage and PV parasitic capacitance burdens the TIs with undesired ground leakage current. In this article, a switched capacitor (SC)-based five-level TI is proposed. The negative dc rail of the proposed TI is directly connected to the grid neutral, thereby completely eliminating the leakage current. Besides, it has the inherent capability of boosting the output voltage without using any magnetic component or additional circuitry. For several instances in every fundamental cycle, the SCs are paralleled with the input voltage source and hence are self-balanced. The proposed topology does not have any limitation on modulation index since the SC voltages are self-balanced and hence less complex or no dedicated control scheme is required. Further, a quantitative comparative study is presented, highlighting the benefits of the proposed TI regarding boosted voltage, elimination of leakage current, and reduced component count. Finally, in order to verify the performance of the proposed TI, detailed simulations followed by experiments on a laboratory prototype developed by using DS1202/1302 dSPACE controller are carried out and the results presented for both steady-state and dynamic conditions verify the feasibility of the proposed TI.
- 28 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (6) , 6237-6245
A Five-Level Transformer-Less Inverter With Self-Voltage Balancing and Boosting Ability
Transformer-less inverters (TIs) are widely used in photovoltaic (PV) applications owing to their low cost and high efficiency. However, the combined effect of high-frequency common mode voltage and PV parasitic capacitance burdens the TIs with undesired ground leakage current. In this article, a switched capacitor (SC)-based five-level TI is proposed. The negative dc rail of the proposed TI is directly connected to the grid neutral, thereby completely eliminating the leakage current. Besides, it has the inherent capability of boosting the output voltage without using any magnetic component or additional circuitry. For several instances in every fundamental cycle, the SCs are paralleled with the input voltage source and hence are self-balanced. The proposed topology does not have any limitation on modulation index since the SC voltages are self-balanced and hence less complex or no dedicated control scheme is required. Further, a quantitative comparative study is presented, highlighting the benefits of the proposed TI regarding boosted voltage, elimination of leakage current, and reduced component count. Finally, in order to verify the performance of the proposed TI, detailed simulations followed by experiments on a laboratory prototype developed by using DS1202/1302 dSPACE controller are carried out and the results presented for both steady-state and dynamic conditions verify the feasibility of the proposed TI.
- Open Access
System Parameter Based Performance Optimization of Solar PV Systems with Perturbation Based MPPT Algorithms
Maximum power point tracking (MPPT) algorithms are invariably employed to utilize solar photovoltaic (PV) systems effectively. Perturbation based MPPT algorithms are popular due to their simplicity and reasonable efficiency. While novel MPPT algorithms claim increased energy utilization over classic perturbation techniques, their performance is governed by the choice of optimal algorithm parameters. Existing guidelines for parameter optimization are mathematically laborious and are not generic. Hence, this paper aims to provide simple and comprehensive guidelines to ensure optimal performance from the perturbation based MPPT technique. For an illustration of proposed claims, a solar PV fed boost converter is investigated to examine the effect of input capacitor, digital filter cut-off frequency, system time constant and sampling time on implementing a classic Perturb and Observe (P and O) algorithm. The readers will be presented with two simple step tests (to determine the effective system time constant) and proposed guidelines to choose the optimal performance sampling time. Necessary laboratory experiments show that an appropriate choice of sampling time could increase efficiency and ensure system stability. This investigation’s learnings can be easily extended to any power electronics converter, loads and all perturbation-based algorithms used in solar PV systems. The results of appropriate tests on the system’s mathematical model and the laboratory prototype are presented in detail to support this research’s claims.
Open AccessSystem Parameter Based Performance Optimization of Solar PV Systems with Perturbation Based MPPT Algorithms
Maximum power point tracking (MPPT) algorithms are invariably employed to utilize solar photovoltaic (PV) systems effectively. Perturbation based MPPT algorithms are popular due to their simplicity and reasonable efficiency. While novel MPPT algorithms claim increased energy utilization over classic perturbation techniques, their performance is governed by the choice of optimal algorithm parameters. Existing guidelines for parameter optimization are mathematically laborious and are not generic. Hence, this paper aims to provide simple and comprehensive guidelines to ensure optimal performance from the perturbation based MPPT technique. For an illustration of proposed claims, a solar PV fed boost converter is investigated to examine the effect of input capacitor, digital filter cut-off frequency, system time constant and sampling time on implementing a classic Perturb and Observe (P and O) algorithm. The readers will be presented with two simple step tests (to determine the effective system time constant) and proposed guidelines to choose the optimal performance sampling time. Necessary laboratory experiments show that an appropriate choice of sampling time could increase efficiency and ensure system stability. This investigation’s learnings can be easily extended to any power electronics converter, loads and all perturbation-based algorithms used in solar PV systems. The results of appropriate tests on the system’s mathematical model and the laboratory prototype are presented in detail to support this research’s claims.
- 23 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (4) , 5016-5025
A Five-Level Boosting Inverter for PV Application
Transformerless inverters (TIs) are widely used in grid-connected photovoltaic (PV) applications due to their higher efficiency and low cost. However, the absence of galvanic isolation leads to the flow of ground leakage current due to PV parasitics resulting in safety issues and deteriorated power quality. This article proposes a single-phase five-level TI topology with switched diodes and floating capacitors (FCs). The proposed topology employs a lower number of active power switches and has self-voltage-balancing of FCs, voltage boosting ability, and suppressed leakage current complying with the VDE-4105 standard for safety. A suitable modulation strategy is applied to the proposed TI in order to generate a common-mode voltage with a reduced number of voltage swings and transitions yielding in suppressed leakage current. Simulation and experiment results are presented to prove the operability of the proposed TI. A prototype model rated for 1 kW is developed, and the experimental results so obtained are presented. The leakage currents of magnitudes ≈10 and ≈17 mA are obtained in the simulation and experiments, respectively. A detailed comparison with the other similar topologies is presented to attest to the merits of the proposed TI.
- 23 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (4) , 5016-5025
A Five-Level Boosting Inverter for PV Application
Transformerless inverters (TIs) are widely used in grid-connected photovoltaic (PV) applications due to their higher efficiency and low cost. However, the absence of galvanic isolation leads to the flow of ground leakage current due to PV parasitics resulting in safety issues and deteriorated power quality. This article proposes a single-phase five-level TI topology with switched diodes and floating capacitors (FCs). The proposed topology employs a lower number of active power switches and has self-voltage-balancing of FCs, voltage boosting ability, and suppressed leakage current complying with the VDE-4105 standard for safety. A suitable modulation strategy is applied to the proposed TI in order to generate a common-mode voltage with a reduced number of voltage swings and transitions yielding in suppressed leakage current. Simulation and experiment results are presented to prove the operability of the proposed TI. A prototype model rated for 1 kW is developed, and the experimental results so obtained are presented. The leakage currents of magnitudes ≈10 and ≈17 mA are obtained in the simulation and experiments, respectively. A detailed comparison with the other similar topologies is presented to attest to the merits of the proposed TI.
- 16 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 65, 1-5
Five-level Common Ground Type Inverter for PV Application
In renewable energy sources transformer-less grid-tied inverters are widely used due to their higher efficiency, reduced cost and size. With the absence of transformer, there exists leakage current due to PV-to-ground parasitic capacitance leads to deteriorated power quality, cause personal safety issues and electromagnetic interference (EMI). In this paper, a five-level transformer-less inverter topology is proposed to eliminates the leakage current based on the principle of switched capacitor. Besides, the proposed topology has naturally balanced voltage capability, so no dedicated control strategy/algorithm is required for balancing/regulating the flying capacitor voltages. The performance of the proposed inverter is verified by simulation results, proving the feasibility and merits of proposed inverter topology are presented. Results depicting the output voltage, load current and voltage across the auxiliary capacitor are presented for various operating conditions. Further, simulation results depicting the leakage current in the proposed, H-5 and H-6 topologies are included. Moreover, a quantitative comparison study is presented, highlighting the benefits of the proposed inverter topology regarding boosted voltage, elimination of leakage current and reduced component count.
- 16 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 65, 1-5
Five-level Common Ground Type Inverter for PV Application
In renewable energy sources transformer-less grid-tied inverters are widely used due to their higher efficiency, reduced cost and size. With the absence of transformer, there exists leakage current due to PV-to-ground parasitic capacitance leads to deteriorated power quality, cause personal safety issues and electromagnetic interference (EMI). In this paper, a five-level transformer-less inverter topology is proposed to eliminates the leakage current based on the principle of switched capacitor. Besides, the proposed topology has naturally balanced voltage capability, so no dedicated control strategy/algorithm is required for balancing/regulating the flying capacitor voltages. The performance of the proposed inverter is verified by simulation results, proving the feasibility and merits of proposed inverter topology are presented. Results depicting the output voltage, load current and voltage across the auxiliary capacitor are presented for various operating conditions. Further, simulation results depicting the leakage current in the proposed, H-5 and H-6 topologies are included. Moreover, a quantitative comparison study is presented, highlighting the benefits of the proposed inverter topology regarding boosted voltage, elimination of leakage current and reduced component count.
- Open Access
- 1 December 2020
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 9 (6) , 2302-2310
Autonomous microgrid based parallel inverters using droop controller for improved power sharing
The existing microgrid has become a challenge to the sustainable energy source to provide a better quality of power to the consumer. To build a reliable and efficient microgrid, designing a droop controller for the microgrid is of utmost importance. In this paper, multiple voltage source inverters connected in parallel using an active power-frequency/reactive power-voltage droop scheme. The proposed method connected to two distributed generators local controllers, where each unit consists of a droop controller with an inner voltage-current controller and a virtual droop controller. By adding this controller to the microgrid reliability and load adaptability of an islanded system can be improved. This concept applied without any real-time communication to the microgrid. Thus, simulated using MATLAB/Simulink, the obtained results prove the effectiveness of the autonomous operation's microgrid model.
- 1 December 2020
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 9 (6) , 2302-2310
Open AccessAutonomous microgrid based parallel inverters using droop controller for improved power sharing
The existing microgrid has become a challenge to the sustainable energy source to provide a better quality of power to the consumer. To build a reliable and efficient microgrid, designing a droop controller for the microgrid is of utmost importance. In this paper, multiple voltage source inverters connected in parallel using an active power-frequency/reactive power-voltage droop scheme. The proposed method connected to two distributed generators local controllers, where each unit consists of a droop controller with an inner voltage-current controller and a virtual droop controller. By adding this controller to the microgrid reliability and load adaptability of an islanded system can be improved. This concept applied without any real-time communication to the microgrid. Thus, simulated using MATLAB/Simulink, the obtained results prove the effectiveness of the autonomous operation's microgrid model.
- 23 September 2020
- Published by Springer Nature
- p. 155-166
Implementation of Perturbation-Based MPPT Technique Using Model-Based Design
- 23 September 2020
- Published by Springer Nature
- p. 155-166
Implementation of Perturbation-Based MPPT Technique Using Model-Based Design
- 20 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1
Common-Ground-Type Five-Level Transformerless Inverter Topology With Full DC-Bus Utilizaton
Transformerless inverters (TIs) are wide-spread in photovoltaic (PV) applications due to their low cost and high efficiency. However, TIs suffer due to leakage current as a consequence of PV parasitic capacitance, and high-frequency commonmode voltage, which has resulted in the emergence of several topological and control scheme modifications. In this paper, a switched-capacitor (SC) based inverter capable of synthesizing a five-level voltage is proposed. In the devised structure, the negative pole of the dc-bus is directly connected to the grid neutral, thereby resulting in zero leakage current. In addition, industrial standard half-bridge modules can be employed directly for implementing the proposed inverter without modifications, making it more practically feasible. The proposed topology has the capability of self-voltage balancing of SC, reactive power processing, and full dc-bus utilization as opposed to half-bridge topologies. The principle of operation and a simple logic gate based pulse generation scheme is presented in detail. Simulation and experimental results confirming the practical viability of the proposed topology are presented. Finally, the superior features, and the merits of the proposed topology are shown through a detailed comparison against state-of-the-art topologies.
- 20 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1
Common-Ground-Type Five-Level Transformerless Inverter Topology With Full DC-Bus Utilizaton
Transformerless inverters (TIs) are wide-spread in photovoltaic (PV) applications due to their low cost and high efficiency. However, TIs suffer due to leakage current as a consequence of PV parasitic capacitance, and high-frequency commonmode voltage, which has resulted in the emergence of several topological and control scheme modifications. In this paper, a switched-capacitor (SC) based inverter capable of synthesizing a five-level voltage is proposed. In the devised structure, the negative pole of the dc-bus is directly connected to the grid neutral, thereby resulting in zero leakage current. In addition, industrial standard half-bridge modules can be employed directly for implementing the proposed inverter without modifications, making it more practically feasible. The proposed topology has the capability of self-voltage balancing of SC, reactive power processing, and full dc-bus utilization as opposed to half-bridge topologies. The principle of operation and a simple logic gate based pulse generation scheme is presented in detail. Simulation and experimental results confirming the practical viability of the proposed topology are presented. Finally, the superior features, and the merits of the proposed topology are shown through a detailed comparison against state-of-the-art topologies.