DNDominik Neumayr

Dominik Neumayr

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dominik Neumayr has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparative Evaluation of a Full- and Partial-Power Processing Active Power Buffer for Ultracompact Single-Phase DC/AC Converter Systems

    by Dominik Neumayr, Gustavo Carlos Knabben, Elise Varescon, Dominik Bortis, Johann W. Kolar

    One of the key technical challenges of the Google & IEEE Little Box competition, an international contest to build the world’s smallest 2kW single-phase inverter in 2015, was to shrink the volume of the energy storage required to cope with the twice mains-frequency (120 Hz) pulsating power at the AC side and meet the stringent 2:5% input voltage ripple at the DC side. In this paper, first, a full-power processing bucktype converter active buffer approach, selected by the 1st prize winner of the Little Box Challenge (LBC) is analyzed in detail. Being relieved from strict voltage ripple requirements, a larger voltage ripple is allowed across the buffer capacitor significantly reducing the capacitance requirement. Second, a partial-power active buffer approach, selected by the 2nd prize winner of the LBC, where conventional passive capacitive buffering of the DClink is combined with a series-connected auxiliary converter, used to compensate the remaining 120 Hz voltage ripple across the DClink capacitance, is studied in detail. In this paper, both selected concepts are comparatively evaluated in terms of achievable efficiency, power density and ripple compensation performance under both stationary and transient conditions. Novel control schemes and optimally designed hardware prototypes for both considered buffer concepts are presented and accompanied with experimental measurements to support the claimed efficiency and power density and assess the performance of the implemented control systems. Finally, by means of comparison with conventional passive DC-link buffering using only electrolytic capacitors, it is determined at what voltage ripple requirement it actually becomes beneficial in terms of volume to employ the considered active buffer concepts.


  • On the Origin of the $C_{\text{oss}}$ -Losses in Soft-Switching GaN-on-Si Power HEMTs

    by Mattia Guacci, Morris Heller, Dominik Neumayr, Dominik Bortis, Johann W. Kolar, Gerald Deboy, Clemens Ostermaier, Oliver Haberlen

    The unprecedented performance potential of Gallium- Nitride-on-Silicon (GaN-on-Si) High Electron Mobility Transistors (HEMTs) is seen as the key enabler for the design of power converters featuring extreme power-density figures, as demanded in next generation power electronics applications. However, unexpected loss mechanisms, i.e. dynamic Rds,on phenomena and Cosslosses, are appearing in currently available GaN transistors and are compromising their operation. In this paper, measurements of Coss-losses are performed in a dedicated calorimetric measurement setup and, through a systematic approach, the root cause of the loss mechanism is potentially identified. Afterwards, with the essential support of a manufacturer of power semiconductors, a novel transistor, featuring an enhanced multi-layer III-N buffer, is developed according to the acquired knowledge. A significant reduction in terms of Coss-losses, i.e. of soft-switching losses, and the absence of dynamic Rds,on phenomena are verified experimentally on the new device. These achievements enable a significant performance improvement for future soft-switching power converters featuring GaN-on-Si HEMTs.


  • P$^{3}$DCT—Partial-Power Pre-Regulated DC Transformer

    by Dominik Neumayr, Matthias Vohringer, Nikolaos Chrysogelos, Gerald Deboy, Johann W. Kolar

    In this paper, a new approach to regulate the output voltage of a resonant, constant voltage transfer ratio 380 V/48 V isolated dc-dc converter is presented. Rather than applying variable frequency control to the resonant converter, which would result in reactive power processing and a more complicated electromagnetic compatibility filter design, the converter remains in its optimal operating point all time and an additional partial-power (PP) processing auxiliary converter is used to tightly regulate the output voltage. The PP converter, supplied through a tertiary winding of the resonant converter's transformer, regulates the output by adding or subtracting voltage from the dc input and has only a marginal impact on the overall efficiency of the dc-dc converter. The principal of operation is explained in detail including Sankey diagrams to illustrate the power processing of the converter and a feedback control system is proposed to tightly regulate the 48 V output voltage. A hardware demonstrator rated at 1.5 kW is implemented to cope with input voltage variations between 340 and 420 V and experimental results are provided showing that the output voltage can be kept within ±1% of the nominal 48 V even under harsh input voltage and load transients. The realized dc-dc converter with PP pre-regulation features an overall efficiency of 97.7% at rated power and a power density of 8.6 kWdm -3 (141w/ 3 in).


  • Constant duty cycle sinusoidal output inverter with sine amplitude modulated high frequency link

    by Gustavo C. Knabben, Dominik Neumayr, Johann W. Kolar

    Despite the increasing performance of power semi-conductors and passives components, limited timing resolution in off-the-shelf available digital control hardware often prevents the switching frequency in kW-scale dc/ac power conversion to be increased above several MHz for the sake of extreme power densities. In this paper an alternative approach to generate a sinusoidal output voltage, based on constant duty cycle frequency shift control of a high frequency resonant inverter stage and a subsequent synchronous cycloconverter, is analyzed. The design of the presented converter is facilitated by means of a derived mathematical model. A novel closed-loop control system is proposed which achieves tight regulation of the output voltage by means of controlling the switching frequencies of the involved bridge legs operated in resonant mode. Characteristic waveforms of the dc/ac converter during steady-state and load transients are presented. Two distinct implementations of the resonant inverter stage, constituting an intermediate voltage or intermediate current link, are analysed and compared.