Matthew James Memmott
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matthew James Memmott has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Parthiban Arumugam
Nuclear Medicine Centre, Manchester University NHS Foundation Trust, United Kingdom
3 shared publicationsChristine M. Tonge
Nuclear Medicine, Central Manchester University Hospitals, Oxford Road, Manchester, M13 9WL, United Kingdom
2 shared publicationsAndrew Michael Crean
Nuclear Medicine Centre, Manchester University NHS Foundation Trust, United Kingdom
1 shared publication- Antoine Saillant
Institute of Biomedical Engineering, ORCRB, University of Oxford, Oxford, OX3 7DQ, UK
1 shared publication Charles Hayden
Siemens Medical Solutions USA, Inc., Molecular Imaging, Knoxville, 37932, TN, USA
1 shared publicationDeborah Tout
Department of Nuclear Medicine, Central Manchester University Hospitals NHS Foundation Trust, Oxford Road, Manchester, M13 9WL, United Kingdom
1 shared publication
Latest Publications
- 1 July 2025
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 18 (7) , e018488
Myocardial Perfusion PET-CT: There’s More Here Than Meets the (A)I
- 1 July 2025
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 18 (7) , e018488
Myocardial Perfusion PET-CT: There’s More Here Than Meets the (A)I
- 19 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (5) , 1216-1226
Assessing Reliability of Myocardial Blood Flow After Motion Correction With Dynamic PET Using a Bayesian Framework
The estimation of myocardial blood flow (MBF) in dynamic PET can be biased by many different processes. A major source of error, particularly in clinical applications, is patient motion. Patient motion, or gross motion, creates displacements between different PET frames as well as between the PET frames and the CT-derived attenuation map, leading to errors in MBF calculation from voxel time series. Motion correction techniques are challenging to evaluate quantitatively and the impact on MBF reliability is not fully understood. Most metrics, such as Signal to Noise Ratio (SNR), are characteristic of static images, and are not specific to motion correction in dynamic data. This study presents a new approach of estimating motion correction quality in dynamic cardiac PET imaging. It relies on calculating a MBF surrogate, K1, along with the uncertainty on the parameter. This technique exploits a Bayesian framework, representing the kinetic parameters as a probability distribution, from which uncertainty measures can be extracted. If the uncertainty extracted is high the parameter studied is considered to have high variability - or low confidence - and vice versa. The robustness of the framework is evaluated on simulated time activity curves to ensure that uncertainties are consistently estimated at multiple levels of noise. Our framework is applied on 40 patient datasets, divided in 4 motion magnitude categories. Experienced observers manually realigned clinical datasets with 3D translations to correct for motion. K1 uncertainties were compared before and after correction. A reduction of uncertainty after motion correction of up to 60% demonstrates the benefit of motion correction in dynamic PET and as well as provides evidence of the usefulness of the new method presented.
- 19 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (5) , 1216-1226
Assessing Reliability of Myocardial Blood Flow After Motion Correction With Dynamic PET Using a Bayesian Framework
The estimation of myocardial blood flow (MBF) in dynamic PET can be biased by many different processes. A major source of error, particularly in clinical applications, is patient motion. Patient motion, or gross motion, creates displacements between different PET frames as well as between the PET frames and the CT-derived attenuation map, leading to errors in MBF calculation from voxel time series. Motion correction techniques are challenging to evaluate quantitatively and the impact on MBF reliability is not fully understood. Most metrics, such as Signal to Noise Ratio (SNR), are characteristic of static images, and are not specific to motion correction in dynamic data. This study presents a new approach of estimating motion correction quality in dynamic cardiac PET imaging. It relies on calculating a MBF surrogate, K1, along with the uncertainty on the parameter. This technique exploits a Bayesian framework, representing the kinetic parameters as a probability distribution, from which uncertainty measures can be extracted. If the uncertainty extracted is high the parameter studied is considered to have high variability - or low confidence - and vice versa. The robustness of the framework is evaluated on simulated time activity curves to ensure that uncertainties are consistently estimated at multiple levels of noise. Our framework is applied on 40 patient datasets, divided in 4 motion magnitude categories. Experienced observers manually realigned clinical datasets with 3D translations to correct for motion. K1 uncertainties were compared before and after correction. A reduction of uncertainty after motion correction of up to 60% demonstrates the benefit of motion correction in dynamic PET and as well as provides evidence of the usefulness of the new method presented.
- 1 August 2018
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 25 (4) , 1286-1295
Impact of pharmacological stress agent on patient motion during rubidium-82 myocardial perfusion PET/CT
- 1 August 2018
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 25 (4) , 1286-1295
Impact of pharmacological stress agent on patient motion during rubidium-82 myocardial perfusion PET/CT
- 1 December 2016
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 23 (6) , 1457-1466
The performance of quantitation methods in the evaluation of cardiac implantable electronic device (CIED) infection: A technical review
- 1 December 2016
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 23 (6) , 1457-1466
The performance of quantitation methods in the evaluation of cardiac implantable electronic device (CIED) infection: A technical review
- 13 September 2016
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 25 (2) , 596-605
The impact of prompt gamma compensation on myocardial blood flow measurements with rubidium-82 dynamic PET
- 13 September 2016
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 25 (2) , 596-605
The impact of prompt gamma compensation on myocardial blood flow measurements with rubidium-82 dynamic PET
- 1 February 2016
- Published by Elsevier in Cardiology Clinics
- Vol. 34 (1) , 149-165
Radionuclide Imaging of Cardiovascular Infection
- 1 February 2016
- Published by Elsevier in Cardiology Clinics
- Vol. 34 (1) , 149-165
Radionuclide Imaging of Cardiovascular Infection