MVMarc-Antoine Verdier

Marc-Antoine Verdier

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marc-Antoine Verdier has a total of 62 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Monte Carlo simulation of a neuroimaging acquisition with MAPSSIC, a β + sensitive intracerebral microprobe for awake and freely moving rats

    by Samir El Ketara, Franck Agnese, Luis Ammour, Caroline Bouillot, Sandrine Bouvard, Olivier Clausse, Mathieu Dupont, Fabrice Gensolen, Mathieu Goffe, Maciej Kachel, et al.

    Objective: Establishing robust correlations between molecular neuroimaging and behavioral studies is essential in preclinical research to advance our understanding of brain function and to critically assess the translational relevance of animal models in drug development.Achieving this goal, however, requires imaging animals while they are awake and freely moving -an ongoing challenge, as most preclinical imaging techniques rely on anesthesia. Approach: To overcome the limitations imposed by anesthesia, the MAPSSIC project aims to develop a novel implantable pixelated probe based on Monolithic Active Pixel Sensors (MAPS), designed for use in awake, freely moving rats. By virtue of its direct implantation within the targeted brain regions, the MAPSSIC probe enables the local detection of short-range β + particles emitted by radiotracers, in contrast to conventional micro-PET systems that rely on detecting coincident annihilation γ-rays. In this study, we present Monte Carlo simulations of a typical in vivo brain imaging experiment using [ 11 C]Raclopride, a commonly employed β + -emitting radiotracer, to evaluate the probe’s performance. Main results: Results show that over 93 % of detected events originate from particles emitted within the first 2 mm surrounding the probe while also allowing to quantify variations of 5 % to 30 % of the non-displaceable binding potential (BP ND ) with discrepancy of less than 4 % compared to micro-PET. Significance: This Monte Carlo study demonstrates the device’s ability to capture small variations of BP ND based on spatially localized information, validating its suitability for quantitative kinetic analysis in brain structures such as the striatum.

  • Scintillateurs cryogéniques pour la détection d'événements rares, dans les expériences EDELWEISS et EURECA

    by Marc-Antoine Verdier

    Une solution au problème astrophysique de la matière sombre pourrait être apportée par la détection de WIMPs, particules prédites par la supersymétrie. Sa détection directe nécessite de grandes masses de détecteurs capables d'identifier le signal d'un WIMP parmi le fond radioactif et cosmique environnant. Cette thèse se déroule dans le cadre de l'expérience EDELWEISS et la future expérience EURECA qui lui succédera. Ces expériences utilisent une technologie basée sur des détecteurs cryogéniques (bolomètres) à double voies, fonctionnant à quelques dizaines de mK. Ils sont constitués de cristaux qui sont le siège des interactions des particules, dont les dépôts d'énergie vont entraîner une élévation de température ainsi que l'ionisation du cristal, pouvant entraîner des charges ou des photons selon sa nature. Afin d'augmenter la palette de cibles pouvant faire office de bolomètres scintillants, nous avons mis en place un dispositif expérimental permettant d'étudier la scintillation de cristaux refroidis jusqu'à 3 K. Il est basé sur un cryostat à géométrie optique compacte permettant une collecte de lumière améliorée. Une méthode de comptage de photons individuels ainsi qu'un traitement statistique des données permettent de mesurer l'évolution du rendement lumineux et des constantes de temps de scintillation de cristaux entre la température ambiante et 3K. Cette thèse présente ainsi les résultats obtenus à 3 K avec ce dispositif expérimental sur deux cristaux, bien connus à température ambiante: le BGO (Bi4Ge3O12) et le BaF2. Nous présentons également les résultats sur la luminescence du saphir dopé au titane (Ti:Al2O3), sous VUV et refroidi à 8 K.

  • Open Access

    A mobile high-resolution gamma camera for therapeutic dose control during radionuclide therapy

    by Carlotta Trigila, Marc-Antoine Verdier, Laurent Pinot, Françoise Bouvet, Tiffany Beaumont, David Broggio, Aurelie Desbrée, Laurent Ménard

    Objective. Molecular radiotherapy is the most used treatment modality against malign and benign diseases of thyroid. In that context, the large heterogeneity of therapeutic doses in patients and the range of effects observed show that individualized dosimetry is essential for optimizing treatments according to the targeted clinical outcome. Approach. We developed a high-resolution mobile gamma camera specifically designed to improve the quantitative assessment of the distribution and biokinetics of 131 I at patients’s bedside after treatment of thyroid diseases. The first prototype has a field of view of 5 × 5 cm 2 and consists of a high-energy parallel-hole collimator made of 3D-printed tungsten, coupled to a 6 mm thick CeBr 3 scintillator readout by an array of silicon photomultiplier detectors. The intrinsic and overall imaging performance of the camera was evaluated with 133 Ba and 131 I sources. In order to test its quantification capability in realistic clinical conditions, two different 3D-printed thyroid phantoms homogeneously filled with 131 I were used. Both single view and conjugate view approaches have been applied, with and without scatter correction technique. Main Results. The camera exhibits high imaging performance with an overall energy resolution of 7.68 ± 0.01%, a submillimetric intrinsic spatial resolution of 0.74 ± 0.28 mm and a very low spatial distortion 0.15 ± 0.10 mm. The complete calibration of the camera shows an overall spatial resolution of 3.14 ± 0.03 mm at a distance of 5 cm and a corresponding sensitivity of 1.23 ± 0.01 cps/MBq, which decreases with distance and slightly changes with source size due to the influence of scattering. Activity recovery factors better than 97% were found with the thyroid phantoms. Significance. These preliminary results are very encouraging for the use of our camera as a tool for accurate quantification of absorbed doses and currently motivates the development of a fully operational clinical camera with a 10 × 10 cm 2 field of view and improved imaging capabilities.


  • Open Access

    MAPSSIC, a Novel CMOS Intracerebral Positrons Probe for Deep Brain Imaging in Awake and Freely Moving Rats: A Monte Carlo Study

    by L. Ammour, J. Heymes, M. Bautista, S. Fieux, F. Gensolen, M. Kachel, A. Dubois, F. Lefebvre, F. Pain, P. Pangaud, et al.

    Preclinical behavior neuroimaging gathers simultaneous assessment of behavior and functional brain imaging. It is a potential key breakthrough to improve the understanding of brain processes and assess the validity of preclinical studies in drug development. Achieving such a combination is difficult, anesthesia or restraints inherent to conventional nuclear imaging preclude its use for behavior studies. In that context, we have proposed an original strategy using submillimetric probes to directly measures positrons inside the rat brain. This paper gives the results of Monte Carlo simulations of a new generation of intracerebral positron probe based on a CMOS Monolithic Active Pixel Sensor. We present the results obtained for a probe into a large homogeneous volume of radioactive water (18F) leading to a sensitivity of 0.88 cps ∙ Bq-1 ∙ mm3 and a mean energy deposition by positrons of 15.1 keV. Simulation in simplified brain-shaped sources modeling a 11c-raclopride experiment shows that the implanted volume modeling the left putamen contribute to 92.4% of the signal from positrons. We also investigate the effects of the thickness of the sensitive layer, the energy threshold and pixel dimensions on the detection capacities of the sensor. We demonstrate that an increase in the sensitive thickness from 18 to 190μ would lead to an increase of positrons sensitivity by a factor of 1.74, but to a decrease of the direct (positrons) to indirect (γ-rays and electrons) sensitivity ratio by a factor of 1.59. Finally we show that for a threshold lower than about 5keV the effect of the pixel dimensions is negligible.


  • Design optimization and performances of an intraoperative positron imaging probe for radioguided cancer surgery

    by S. Spadola, M.-A. Verdier, L. Pinot, C. Esnault, N. Dinu, Y. Charon, M.-A. Duval, L. Ménard


  • Scintillation properties of Bi4Ge3O12down to 3 K underγrays

    by M.-A. Verdier, P. C. F. Di Stefano, P. Nadeau, C. Behan, M. Clavel, C. Dujardin

    Bismuth germanate (BGO) has been widely used as a room-temperature scintillator in many applications for decades. Interest in it has recently increased as a low-temperature scintillator to be used in bolometers for rare-event detection. We present our time-resolved-scintillation studies of BGO down to 3 K under $\gamma${}-ray excitation. Our multiple-photon-counting-coincidence-based setup allows clear identification of $\gamma${}-line energies at least as low as 122 keV down to base temperature and the measurement of the light yield and decay-time constants as a function of temperature. We also discuss the time structure of the pulses and report a previously unappreciated but significant, very slow component assigned to afterglow. Finally, we demonstrate that nonlinearity of the light yield as a function of energy persists at low temperatures.