Maxime Toussaint
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Maxime Toussaint has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Roger Lecomte
Université de Sherbrooke
8 shared publications - Francis Loignon-Houle
Instituto de Instrumentacin para Imagen Molecular, Centro Mixto CSICUniversitat Politcnica de Valncia, Valencia, Spain
3 shared publications - Alexis Pereda
Université Clermont Auvergne
2 shared publications - Andreas Franz Resch
Medical Physics, MedAustron, Marie-Curie-Straße 5, Wiener Neustadt, 2700 , AUSTRIA
2 shared publications - Axel Rannou
UBO, 22 Avenue Camille Desmoulins, Brest, 29238, FRANCE
2 shared publications - Carlotta Trigila
Department of Computer Science, University of California Davis, One Shields Avenue, Davis, 95616-5270, UNITED STATES
2 shared publications
Latest Publications
- 1 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (4) , 535-546
YRT-PET: An Open-Source GPU-Accelerated Image Reconstruction Engine for Positron Emission Tomography
Image reconstruction for positron emission tomography (PET) requires an accurate model of the PET scanner geometry and degrading factors to produce high-quality and clinically meaningful images. It is typically implemented by scanner manufacturers, with proprietary software designed specifically for each scanner. This limits the ability to perform direct comparisons between scanners or to develop advanced image reconstruction algorithms. Open-source image reconstruction software can offer an alternative to manufacturer implementations, allowing more control and portability. Several existing software packages offer a wide range of features and interfaces, but there is still a need for an engine that simultaneously offers reusable code, fast implementation and convenient interfaces for interoperability and extensibility.
- 1 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (4) , 535-546
YRT-PET: An Open-Source GPU-Accelerated Image Reconstruction Engine for Positron Emission Tomography
Image reconstruction for positron emission tomography (PET) requires an accurate model of the PET scanner geometry and degrading factors to produce high-quality and clinically meaningful images. It is typically implemented by scanner manufacturers, with proprietary software designed specifically for each scanner. This limits the ability to perform direct comparisons between scanners or to develop advanced image reconstruction algorithms. Open-source image reconstruction software can offer an alternative to manufacturer implementations, allowing more control and portability. Several existing software packages offer a wide range of features and interfaces, but there is still a need for an engine that simultaneously offers reusable code, fast implementation and convenient interfaces for interoperability and extensibility.
- Top Cited PapersOpen Access
- 14 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (1) , 015042
GATE 10 Monte Carlo particle transport simulation: I. Development and new features
We present GATE version 10, a major evolution of the open-source Monte Carlo simulation application for medical physics, built on Geant4. This release marks a transformative evolution, featuring a modern Python-based user interface, enhanced multithreading and multiprocessing capabilities, the ability to be embedded as a library within other software, and a streamlined framework for collaborative development. In this Part 1 paper, we outline GATE’s position among other Monte Carlo codes, the core principles driving this evolution, and the robust development cycle employed. We also detail the new features and improvements. Part 2 will focus on the architectural innovations and technical challenges. By combining an open, collaborative framework with cutting-edge features, such a Monte Carlo platform supports a wide range of academic and industrial research, solidifying its role as a critical tool for innovation in medical physics.
- 14 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (1) , 015042
Top Cited PapersOpen AccessGATE 10 Monte Carlo particle transport simulation: I. Development and new features
We present GATE version 10, a major evolution of the open-source Monte Carlo simulation application for medical physics, built on Geant4. This release marks a transformative evolution, featuring a modern Python-based user interface, enhanced multithreading and multiprocessing capabilities, the ability to be embedded as a library within other software, and a streamlined framework for collaborative development. In this Part 1 paper, we outline GATE’s position among other Monte Carlo codes, the core principles driving this evolution, and the robust development cycle employed. We also detail the new features and improvements. Part 2 will focus on the architectural innovations and technical challenges. By combining an open, collaborative framework with cutting-edge features, such a Monte Carlo platform supports a wide range of academic and industrial research, solidifying its role as a critical tool for innovation in medical physics.
- Top Cited PapersOpen Access
- 14 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (1) , 015043
GATE 10 Monte Carlo particle transport simulation: II. Architecture and innovations
Over the past years, we have developed GATE version 10, a major re-implementation of the long-standing Geant4-based Monte Carlo application for particle and radiation transport simulation in medical physics. This release introduces many new features and significant improvements, most notably a Python-based user interface replacing the legacy static input files. The new functionality of GATE version 10 is described in the part 1 companion paper (Sarrut et al 2025 arXiv:2507.09842). The development brought significant challenges. In this paper, we present the solutions that we have developed to overcome these challenges. In particular, we present a modular design that robustly manages the core components of a simulation: particle sources, geometry, physics processes, and data acquisition. The architecture consists of integrated C++ and Python codes. This framework allows for the precise, time-aware generation of primary particles, a critical requirement for accurately modeling positron emission tomography, radionuclide therapies, or prompt-gamma timing systems. We present how GATE 10 handles complex Geant4 physics settings while exposing a simple interface to the user. Furthermore, we describe the methodological solutions that facilitate the seamless integration of advanced physics models and variance reduction techniques. The architecture supports sophisticated scoring of physical quantities (such as Linear Energy Transfer and Relative Biological Effectiveness) and is designed for multithreaded execution. The new user interface allows researchers to script complex simulation workflows and directly couple external tools, such as artificial intelligence models for source generation or detector response. By detailing these architectural innovations, we demonstrate how GATE 10 provides a more powerful and flexible tool for research and innovation in medical physics. This paper is not intended to be a developer guide. Its purpose is to share with the research community in-depth explanations of our development effort that made the new GATE 10 possible.
- 14 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (1) , 015043
Top Cited PapersOpen AccessGATE 10 Monte Carlo particle transport simulation: II. Architecture and innovations
Over the past years, we have developed GATE version 10, a major re-implementation of the long-standing Geant4-based Monte Carlo application for particle and radiation transport simulation in medical physics. This release introduces many new features and significant improvements, most notably a Python-based user interface replacing the legacy static input files. The new functionality of GATE version 10 is described in the part 1 companion paper (Sarrut et al 2025 arXiv:2507.09842). The development brought significant challenges. In this paper, we present the solutions that we have developed to overcome these challenges. In particular, we present a modular design that robustly manages the core components of a simulation: particle sources, geometry, physics processes, and data acquisition. The architecture consists of integrated C++ and Python codes. This framework allows for the precise, time-aware generation of primary particles, a critical requirement for accurately modeling positron emission tomography, radionuclide therapies, or prompt-gamma timing systems. We present how GATE 10 handles complex Geant4 physics settings while exposing a simple interface to the user. Furthermore, we describe the methodological solutions that facilitate the seamless integration of advanced physics models and variance reduction techniques. The architecture supports sophisticated scoring of physical quantities (such as Linear Energy Transfer and Relative Biological Effectiveness) and is designed for multithreaded execution. The new user interface allows researchers to script complex simulation workflows and directly couple external tools, such as artificial intelligence models for source generation or detector response. By detailing these architectural innovations, we demonstrate how GATE 10 provides a more powerful and flexible tool for research and innovation in medical physics. This paper is not intended to be a developer guide. Its purpose is to share with the research community in-depth explanations of our development effort that made the new GATE 10 possible.
- 16 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (2) , 210-217
Time-of-Flight Requirements to Mitigate Blurring Induced by Annihilation Photon Acollinearity
One of the limiting factors of spatial resolution in PET imaging is annihilation photon acollinearity (APA). For whole-body PET scanners, APA induces a blur ranging from 1.7 mm to 2.2 mm FWHM. For long axial field of view (FOV) scanners, this range increases even more, depending on the maximum ring difference. It was previously shown that perfect time-of-flight (TOF) resolution sharpens the APA-induced blur by altering its expected Gaussian shape into a profile resembling a 1/r function, thereby reducing its contribution to spatial resolution loss. This suggests that the conventional theoretical limit of PET spatial resolution could be overcome if sufficient TOF resolution can be achieved. However, the requirements to achieve an observable gain in spatial resolution have yet to be explored. We propose an investigation of these requirements for whole-body and long axial FOV scanners, in terms of TOF resolution and count statistics. Using a fictive 81 cm diameter scanner with 2 mm wide detectors, we show that ultrafast TOF resolution—13 ps FWHM—enables an observable gain in spatial resolution for a range of count statistics. In addition, we show that lower TOF resolutions (i.e., higher TOF values of 27 or 67 ps) could mitigate APA for the oblique tubes of response of long axial FOV systems subjected to larger APA blurring. This last observation is of particular interest as it suggests that the non-stationary nature of spatial resolution in PET imaging can be further mitigated when such TOF precision is achieved.
- 16 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (2) , 210-217
Time-of-Flight Requirements to Mitigate Blurring Induced by Annihilation Photon Acollinearity
One of the limiting factors of spatial resolution in PET imaging is annihilation photon acollinearity (APA). For whole-body PET scanners, APA induces a blur ranging from 1.7 mm to 2.2 mm FWHM. For long axial field of view (FOV) scanners, this range increases even more, depending on the maximum ring difference. It was previously shown that perfect time-of-flight (TOF) resolution sharpens the APA-induced blur by altering its expected Gaussian shape into a profile resembling a 1/r function, thereby reducing its contribution to spatial resolution loss. This suggests that the conventional theoretical limit of PET spatial resolution could be overcome if sufficient TOF resolution can be achieved. However, the requirements to achieve an observable gain in spatial resolution have yet to be explored. We propose an investigation of these requirements for whole-body and long axial FOV scanners, in terms of TOF resolution and count statistics. Using a fictive 81 cm diameter scanner with 2 mm wide detectors, we show that ultrafast TOF resolution—13 ps FWHM—enables an observable gain in spatial resolution for a range of count statistics. In addition, we show that lower TOF resolutions (i.e., higher TOF values of 27 or 67 ps) could mitigate APA for the oblique tubes of response of long axial FOV systems subjected to larger APA blurring. This last observation is of particular interest as it suggests that the non-stationary nature of spatial resolution in PET imaging can be further mitigated when such TOF precision is achieved.
- Open Access
- 10 September 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (18) , 18NT01
On the implementation of acollinearity in PET Monte Carlo simulations
Objective. Acollinearity of annihilation photons (APA) introduces spatial blur in positron emission tomography (PET) imaging. This phenomenon increases proportionally with the scanner diameter and it has been shown to follow a Gaussian distribution. This last statement can be interpreted in two ways: the magnitude of the acollinearity angle, or the angular deviation of annihilation photons from perfect collinearity. As the former constitutes the partial integral of the latter, a misinterpretation could have significant consequences on the resulting spatial blurring. Previous research investigating the impact of APA in PET imaging has assumed the Gaussian nature of its angular deviation, which is consistent with experimental results. However, a comprehensive analysis of several simulation software packages for PET data acquisition revealed that the magnitude of APA was implemented as a Gaussian distribution. Approach. We quantified the impact of this misinterpretation of APA by comparing simulations obtained with GATE, which is one of these simulation programs, to an in-house modification of GATE that models APA deviation as following a Gaussian distribution. Main results. We show that the APA misinterpretation not only alters the spatial blurring profile in image space, but also considerably underestimates the impact of APA on spatial resolution. For an ideal PET scanner with a diameter of 81 cm, the APA point source response simulated under the first interpretation has a cusp shape with 0.4 mm FWHM. This is significantly different from the expected Gaussian point source response of 2.1 mm FWHM reproduced under the second interpretation. Significance. Although this misinterpretation has been found in several PET simulation tools, it has had a limited impact on the simulated spatial resolution of current PET scanners due to its small magnitude relative to the other factors. However, the inaccuracy it introduces in estimating the overall spatial resolution of PET scanners will increase as the performance of newer devices improves.
- 10 September 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (18) , 18NT01
Open AccessOn the implementation of acollinearity in PET Monte Carlo simulations
Objective. Acollinearity of annihilation photons (APA) introduces spatial blur in positron emission tomography (PET) imaging. This phenomenon increases proportionally with the scanner diameter and it has been shown to follow a Gaussian distribution. This last statement can be interpreted in two ways: the magnitude of the acollinearity angle, or the angular deviation of annihilation photons from perfect collinearity. As the former constitutes the partial integral of the latter, a misinterpretation could have significant consequences on the resulting spatial blurring. Previous research investigating the impact of APA in PET imaging has assumed the Gaussian nature of its angular deviation, which is consistent with experimental results. However, a comprehensive analysis of several simulation software packages for PET data acquisition revealed that the magnitude of APA was implemented as a Gaussian distribution. Approach. We quantified the impact of this misinterpretation of APA by comparing simulations obtained with GATE, which is one of these simulation programs, to an in-house modification of GATE that models APA deviation as following a Gaussian distribution. Main results. We show that the APA misinterpretation not only alters the spatial blurring profile in image space, but also considerably underestimates the impact of APA on spatial resolution. For an ideal PET scanner with a diameter of 81 cm, the APA point source response simulated under the first interpretation has a cusp shape with 0.4 mm FWHM. This is significantly different from the expected Gaussian point source response of 2.1 mm FWHM reproduced under the second interpretation. Significance. Although this misinterpretation has been found in several PET simulation tools, it has had a limited impact on the simulated spatial resolution of current PET scanners due to its small magnitude relative to the other factors. However, the inaccuracy it introduces in estimating the overall spatial resolution of PET scanners will increase as the performance of newer devices improves.
- 24 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 7 (7) , 692-703
Timing Estimation and Limits in TOF-PET Detectors Producing Prompt Photons
The production of prompt photons providing high photon time densities is a promising avenue to reach ultrahigh coincidence time resolution (CTR) in time-of-flight positron emission tomography. Detectors producing prompt photons are receiving high interest experimentally, ignited by past exploratory theoretical studies that have anchored some guiding principles. Here, we aim to consolidate and extend the foundations for the analytical modeling of prompt generating detectors. We extend the current models to a larger range of prompt emission kinetics where more stringent requirements on the prompt photon yield rapidly emerge as a limiting factor. Lower bound and estimator evaluations are investigated with different underlying models, notably by merging or keeping separate the prompt and scintillation photon populations. We further show the potential benefits of knowing the proportion of prompt photons within a detection set to improve the CTR by mitigating the detrimental effect of population (prompt versus scintillation) mixing. Taking into account the fluctuations on the average number of detected prompt photons in the model reveals a limited influence when prompt photons are accompanied by fast scintillation (e.g., LSO:Ce:Ca) but a more significant effect when accompanied by slower scintillation (e.g., bismuth germanate). Establishing performance characteristics and limitations of prompt generating detectors is paramount to gauging and targeting the best possible timing capabilities they can offer.
- 24 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 7 (7) , 692-703
Timing Estimation and Limits in TOF-PET Detectors Producing Prompt Photons
The production of prompt photons providing high photon time densities is a promising avenue to reach ultrahigh coincidence time resolution (CTR) in time-of-flight positron emission tomography. Detectors producing prompt photons are receiving high interest experimentally, ignited by past exploratory theoretical studies that have anchored some guiding principles. Here, we aim to consolidate and extend the foundations for the analytical modeling of prompt generating detectors. We extend the current models to a larger range of prompt emission kinetics where more stringent requirements on the prompt photon yield rapidly emerge as a limiting factor. Lower bound and estimator evaluations are investigated with different underlying models, notably by merging or keeping separate the prompt and scintillation photon populations. We further show the potential benefits of knowing the proportion of prompt photons within a detection set to improve the CTR by mitigating the detrimental effect of population (prompt versus scintillation) mixing. Taking into account the fluctuations on the average number of detected prompt photons in the model reveals a limited influence when prompt photons are accompanied by fast scintillation (e.g., LSO:Ce:Ca) but a more significant effect when accompanied by slower scintillation (e.g., bismuth germanate). Establishing performance characteristics and limitations of prompt generating detectors is paramount to gauging and targeting the best possible timing capabilities they can offer.
- 26 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (5) , 729-737
Improvement of Spatial Resolution With Iterative PET Reconstruction Using Ultrafast TOF
The impact of time of flight (TOF) on positron emission tomography (PET) spatial resolution is generally considered negligible. In this work, a two-step approach based on simulations of 2-D scanner configurations is taken to show that ultrafast TOF has the potential to overcome the limitation induced by the physical size of detectors on spatial resolution. An estimation of the lower bound on spatial resolution using point sources is provided, followed by a qualitative assessment of the resolution obtained using a Hot Spot phantom. The impact of detector width, TOF resolution, and TOF binning on the achieved spatial resolution is also studied. While gain beyond the expected blur due to detector size is demonstrated, the detector size remains one limiting factor albeit less prominent. The dependence on acquisition statistics to reach the full potential of TOF-induced gain in spatial resolution is demonstrated. A simulated brain phantom acquired with a fictive 3-D PET scanner was qualitatively analyzed and structures smaller than the typical limit are clearly made visible by reconstructing the images with a ~13-ps TOF resolution. A potential application of this feature of ultrafast TOF would be the design of clinical PET scanners achieving spatial resolution beyond the current state of the art.
- 26 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (5) , 729-737
Improvement of Spatial Resolution With Iterative PET Reconstruction Using Ultrafast TOF
The impact of time of flight (TOF) on positron emission tomography (PET) spatial resolution is generally considered negligible. In this work, a two-step approach based on simulations of 2-D scanner configurations is taken to show that ultrafast TOF has the potential to overcome the limitation induced by the physical size of detectors on spatial resolution. An estimation of the lower bound on spatial resolution using point sources is provided, followed by a qualitative assessment of the resolution obtained using a Hot Spot phantom. The impact of detector width, TOF resolution, and TOF binning on the achieved spatial resolution is also studied. While gain beyond the expected blur due to detector size is demonstrated, the detector size remains one limiting factor albeit less prominent. The dependence on acquisition statistics to reach the full potential of TOF-induced gain in spatial resolution is demonstrated. A simulated brain phantom acquired with a fictive 3-D PET scanner was qualitatively analyzed and structures smaller than the typical limit are clearly made visible by reconstructing the images with a ~13-ps TOF resolution. A potential application of this feature of ultrafast TOF would be the design of clinical PET scanners achieving spatial resolution beyond the current state of the art.
- 21 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (5) , 687-693
TOF Benefits and Trade-offs on Image Contrast-to-Noise Ratio Performance for a Small Animal PET Scanner
Recently, time-of-flight (TOF) scanners have become a mainstream in PET research particularly owing to their ability to improve the image contrast-to-noise ratio (CNR). As the scintillation photon transport directly affects the coincidence time resolution, decreasing crystal length can be considered to improve timing performance even at the cost of sensitivity loss. This would also improve the radial spatial resolution and reduce the cost of the scintillator material particularly in clinical scanners. Hence, this paper investigates the trade-offs between TOF, crystal length, and scan time with the goal of using TOF to compensate for CNR degradation caused by decreasing the scintillator volume in a highly pixelated scanner. To do this, a TOF model of the LabPET II small animal scanner was developed. The contrast recovery coefficient (CRC) and CNR performance were investigated through a factorial design. This was followed by assessing when TOF gain may be advantageous in small animal imaging. Results show that decreasing crystal length by 2 mm improves CRC performance for such a scanner while CNR can be fully recovered by increasing scan time. It was also observed that the same CNR can be reached for a shorter acquisition time if faster TOF resolution is achieved. The paper concludes with a summary of the trade-offs to optimize the CNR.
- 21 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (5) , 687-693
TOF Benefits and Trade-offs on Image Contrast-to-Noise Ratio Performance for a Small Animal PET Scanner
Recently, time-of-flight (TOF) scanners have become a mainstream in PET research particularly owing to their ability to improve the image contrast-to-noise ratio (CNR). As the scintillation photon transport directly affects the coincidence time resolution, decreasing crystal length can be considered to improve timing performance even at the cost of sensitivity loss. This would also improve the radial spatial resolution and reduce the cost of the scintillator material particularly in clinical scanners. Hence, this paper investigates the trade-offs between TOF, crystal length, and scan time with the goal of using TOF to compensate for CNR degradation caused by decreasing the scintillator volume in a highly pixelated scanner. To do this, a TOF model of the LabPET II small animal scanner was developed. The contrast recovery coefficient (CRC) and CNR performance were investigated through a factorial design. This was followed by assessing when TOF gain may be advantageous in small animal imaging. Results show that decreasing crystal length by 2 mm improves CRC performance for such a scanner while CNR can be fully recovered by increasing scan time. It was also observed that the same CNR can be reached for a shorter acquisition time if faster TOF resolution is achieved. The paper concludes with a summary of the trade-offs to optimize the CNR.
- 1 March 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (6) , 065009
Analytical model of DOI-induced time bias in ultra-fast scintillation detectors for TOF-PET
In positron emission tomography (PET), long crystals ( 20 mm) are used to enhance detection efficiency and increase scanner sensitivity. However, for fast time-of-flight (TOF) scanners, this may affect the achievable coincidence time resolution (CTR) due to depth-of-interaction (DOI) induced blur on timing. Currently, the effect of DOI on CTR evaluation with analytical modeling is incorporated using the probability density function (PDF) for attenuation of the annihilation photons with the PDFs of the other scintillation processes. However, we show that the resulting PDF would not describe accurately the variation in timestamps distribution at different DOIs. We propose a new analytical model for the CTR evaluation, which consists of computing a DOI dependent CTR weighted by the DOI probability in coincidence. The CTR was thus defined as the weighted root-mean-square error (RMSE) of the DOI-wise variance and bias in order to explicitly describe the positioning bias induced by coincident annihilation photons at different DOIs. The effect of DOI bias on CTR was investigated by using four classic estimators found in the literature, each applied on contemporary scintillation detectors and nearly ideal detectors. A limited difference in the calculated CTR was found for typical scintillation detectors when assessing RMSE with and without DOI time offset correction. This was expected since the DOI bias remains negligible against other phenomena in such case. However, the difference becomes significant for nearly ideal scintillation detectors, where optimal CTR would only be attainable with DOI correction. For these nearly ideal cases, the revised model has better predictive power since the DOI time offset correction is included. Investigation with analytical approaches for realistically achievable ultra-fast CTR in TOF-PET detectors should be performed with a model that genuinely takes into account the DOI effect. We show that the proposed model is a valid candidate for such a task.
- 1 March 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (6) , 065009
Analytical model of DOI-induced time bias in ultra-fast scintillation detectors for TOF-PET
In positron emission tomography (PET), long crystals ( 20 mm) are used to enhance detection efficiency and increase scanner sensitivity. However, for fast time-of-flight (TOF) scanners, this may affect the achievable coincidence time resolution (CTR) due to depth-of-interaction (DOI) induced blur on timing. Currently, the effect of DOI on CTR evaluation with analytical modeling is incorporated using the probability density function (PDF) for attenuation of the annihilation photons with the PDFs of the other scintillation processes. However, we show that the resulting PDF would not describe accurately the variation in timestamps distribution at different DOIs. We propose a new analytical model for the CTR evaluation, which consists of computing a DOI dependent CTR weighted by the DOI probability in coincidence. The CTR was thus defined as the weighted root-mean-square error (RMSE) of the DOI-wise variance and bias in order to explicitly describe the positioning bias induced by coincident annihilation photons at different DOIs. The effect of DOI bias on CTR was investigated by using four classic estimators found in the literature, each applied on contemporary scintillation detectors and nearly ideal detectors. A limited difference in the calculated CTR was found for typical scintillation detectors when assessing RMSE with and without DOI time offset correction. This was expected since the DOI bias remains negligible against other phenomena in such case. However, the difference becomes significant for nearly ideal scintillation detectors, where optimal CTR would only be attainable with DOI correction. For these nearly ideal cases, the revised model has better predictive power since the DOI time offset correction is included. Investigation with analytical approaches for realistically achievable ultra-fast CTR in TOF-PET detectors should be performed with a model that genuinely takes into account the DOI effect. We show that the proposed model is a valid candidate for such a task.
- 23 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 3 (3) , 334-342
Performance Simulation of an Ultrahigh Resolution Brain PET Scanner Using 1.2-mm Pixel Detectors
The concept of a new ultrahigh resolution (UHR) positron emission tomography (PET) brain scanner featuring truly pixelated detectors based on the LabPET II technology is presented. The aim of this paper is to predict the performance of the scanner using geant4 application for tomographic emission simulations. The NEMA procedures for human and small animal PET scanners were used, whenever appropriate, to simulate spatial resolution, scatter fraction, count rate performance, and the sensitivity of the proposed system compared to state-of-theart PET scanners that would currently be the preferred choices for brain imaging, namely the high-resolution research tomograph dedicated brain PET scanner and the Biograph Vision whole-body clinical PET scanner. The imaging performance was also assessed using the NEMA-NU4 image quality phantom, a mini Hot Spot phantom, and a 3-D voxelized brain phantom. A reconstructed nearly isotropic spatial resolution of 1.3 mm full width at half-maximum is obtained at 10 mm from the center of the field of view. With an energy window of 250-650 keV, the system absolute sensitivity is estimated at 3.4% and its maximum noise equivalent count rate reaches 16.4 kcps at 12 kBq/cc. The simulation results provide evidence of the promising capabilities of the proposed scanner for UHR brain imaging.
- 23 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 3 (3) , 334-342
Performance Simulation of an Ultrahigh Resolution Brain PET Scanner Using 1.2-mm Pixel Detectors
The concept of a new ultrahigh resolution (UHR) positron emission tomography (PET) brain scanner featuring truly pixelated detectors based on the LabPET II technology is presented. The aim of this paper is to predict the performance of the scanner using geant4 application for tomographic emission simulations. The NEMA procedures for human and small animal PET scanners were used, whenever appropriate, to simulate spatial resolution, scatter fraction, count rate performance, and the sensitivity of the proposed system compared to state-of-theart PET scanners that would currently be the preferred choices for brain imaging, namely the high-resolution research tomograph dedicated brain PET scanner and the Biograph Vision whole-body clinical PET scanner. The imaging performance was also assessed using the NEMA-NU4 image quality phantom, a mini Hot Spot phantom, and a 3-D voxelized brain phantom. A reconstructed nearly isotropic spatial resolution of 1.3 mm full width at half-maximum is obtained at 10 mm from the center of the field of view. With an energy window of 250-650 keV, the system absolute sensitivity is estimated at 3.4% and its maximum noise equivalent count rate reaches 16.4 kcps at 12 kBq/cc. The simulation results provide evidence of the promising capabilities of the proposed scanner for UHR brain imaging.