Joonas Koponen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Joonas Koponen has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Antti Kosonen
16 shared publicationsJero Ahola
15 shared publicationsVesa Ruuskanen
9 shared publications- Vesa Ruuskanen
LUT University Lappeenranta Finland
8 shared publications Kimmo Huoman
5 shared publicationsMarkku Niemelä
5 shared publications
Latest Publications
- Open Access
- 1 February 2022
- Published by Elsevier in Applied Energy
- Vol. 307
Simulation methodology for an off-grid solar–battery–water electrolyzer plant: Simultaneous optimization of component capacities and system control
- 1 February 2022
- Published by Elsevier in Applied Energy
- Vol. 307
Open AccessSimulation methodology for an off-grid solar–battery–water electrolyzer plant: Simultaneous optimization of component capacities and system control
- 1 December 2020
- Published by Elsevier in Applied Energy
- Vol. 279
Effect of power quality on the design of proton exchange membrane water electrolysis systems
- 1 December 2020
- Published by Elsevier in Applied Energy
- Vol. 279
Effect of power quality on the design of proton exchange membrane water electrolysis systems
- 1 May 2020
- Published by Elsevier in Journal of Power Sources
- Vol. 459
Power quality and reactive power of water electrolyzers supplied with thyristor converters
- 1 May 2020
- Published by Elsevier in Journal of Power Sources
- Vol. 459
Power quality and reactive power of water electrolyzers supplied with thyristor converters
- 1 February 2020
- Published by Elsevier in Journal of Power Sources
- Vol. 450
Power quality estimation of water electrolyzers based on current and voltage measurements
- 1 February 2020
- Published by Elsevier in Journal of Power Sources
- Vol. 450
Power quality estimation of water electrolyzers based on current and voltage measurements
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. P.1-P.8
Implementing a power source to study the effect of power quality on the PEM water electrolyzer stack
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. P.1-P.8
Implementing a power source to study the effect of power quality on the PEM water electrolyzer stack
- 1 March 2019
- Published by Elsevier in Journal of CO2 Utilization
- Vol. 30, 232-239
Capturing CO2 from air: Technical performance and process control improvement
- 1 March 2019
- Published by Elsevier in Journal of CO2 Utilization
- Vol. 30, 232-239
Capturing CO2 from air: Technical performance and process control improvement
- 1 December 2018
- Published by Elsevier in Journal of CO2 Utilization
- Vol. 28, 235-246
Power-to-X technology using renewable electricity and carbon dioxide from ambient air: SOLETAIR proof-of-concept and improved process concept
- 1 December 2018
- Published by Elsevier in Journal of CO2 Utilization
- Vol. 28, 235-246
Power-to-X technology using renewable electricity and carbon dioxide from ambient air: SOLETAIR proof-of-concept and improved process concept
- 17 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (7) , 6171-6182
Effect of Converter Topology on the Specific Energy Consumption of Alkaline Water Electrolyzers
Water electrolysis will be used to produce renewable hydrogen for energy storage and Power-to-X applications in the future renewable-energy-based energy systems. Therefore, the energy efficiency of hydrogen production will probably become a major issue. In this study, the effect of practical supply power converters on the specific energy consumption ofMW-scale alkaline electrolyzers is studied and compared with an ideal DC power supply. The current quality and the stack specific energy consumption are studied in the case of traditional thyristor rectifiers and a transistor-based converter. The stack specific energy consumption is analyzed based on the simulated current waveforms and the electrical equivalent circuit of the electrolyzer stack. It is found that the transistor-based converter offers up to 14% lower electrolyzer stack specific energy consumption than the 6-pulse thyristor rectifier and up to 9.2% lower electrolyzer stack specific energy consumption than the 12-pulse thyristor rectifier as the current varies between 5000A and 1000A. The simulated change in the stack specific energy consumption of the MW-scale alkaline water electrolyzer outweighs the losses occurring in the rectifiers. Further, selection of the AC voltage level may have a more adverse effect on the stack specific energy consumption with the thyristor rectifier topologies compared with the transistor-based topologies.
- 17 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (7) , 6171-6182
Effect of Converter Topology on the Specific Energy Consumption of Alkaline Water Electrolyzers
Water electrolysis will be used to produce renewable hydrogen for energy storage and Power-to-X applications in the future renewable-energy-based energy systems. Therefore, the energy efficiency of hydrogen production will probably become a major issue. In this study, the effect of practical supply power converters on the specific energy consumption ofMW-scale alkaline electrolyzers is studied and compared with an ideal DC power supply. The current quality and the stack specific energy consumption are studied in the case of traditional thyristor rectifiers and a transistor-based converter. The stack specific energy consumption is analyzed based on the simulated current waveforms and the electrical equivalent circuit of the electrolyzer stack. It is found that the transistor-based converter offers up to 14% lower electrolyzer stack specific energy consumption than the 6-pulse thyristor rectifier and up to 9.2% lower electrolyzer stack specific energy consumption than the 12-pulse thyristor rectifier as the current varies between 5000A and 1000A. The simulated change in the stack specific energy consumption of the MW-scale alkaline water electrolyzer outweighs the losses occurring in the rectifiers. Further, selection of the AC voltage level may have a more adverse effect on the stack specific energy consumption with the thyristor rectifier topologies compared with the transistor-based topologies.