WBWilliam W. Brey

William W. Brey

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


William W. Brey has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Application of Counter-Wound Multi-Arm Spirals in HTS Resonator Design

    by Taylor L. Johnston, Arthur S. Edison, Vijaykumar Ramaswamy, Nicolas Freytag, Matthew E. Merritt, Jeremy N. Thomas, Jerris W. Hooker, Ilya M. Litvak, William W. Brey

    Significant sensitivity improvements have been achieved by utilizing high temperature superconducting (HTS) resonators in nuclear magnetic resonance (NMR) probes. Many nuclei such as 13 C benefit from strong excitation fields which cannot be produced by traditional HTS resonator designs. We investigate the use of double-sided, counter-wound multi-arm spiral HTS resonators with the aim of increasing the excitation field at the required nuclear Larmor frequency for 13 C. When compared to double-sided, counter-wound spiral resonators with similar geometry, simulations indicate that the multi-arm spiral version develops a more uniform current distribution. Preliminary tests of a two-arm resonator indicate that it may produce a stronger excitation field.


  • Open Access

    Accommodation of Pulsed Field Gradients with Cascade Field Regulation in Powered Magnets

    by Benjamin D. McPheron, Jeffrey L. Schiano, Ilya M. Litvak, William W. Brey

    High magnetic fields significantly improve the resolution and sensitivity of nuclear magnetic resonance (NMR) spectroscopy measurements, which presents exciting research opportunities in areas of chemistry, biology, and material science. Powered magnets can provide much higher magnetic fields than persistent mode superconducting magnets but suffer from temporal magnetic field fluctuations due to power supply ripple and variations in cooling water temperature and flow rate which make powered magnets non-viable for high resolution NMR experiments. Previous work has demonstrated that a multi-rate sampled data cascade control system may be used to improve the resolution of NMR experiments in powered magnets. Despite these advances in reducing temporal magnetic field fluctuations, the field regulation design does not accommodate the use of pulsed field gradients, which are necessary in many NMR experiments. This work presents a control topology which accommodates the use of pulsed field gradient signals with the field regulation system. This control approach is verified using NMR measurements.

  • 13C-Optimized HTS NMR RF Coil Design at 21.1 T

    by Omid Sanati, Arthur S. Edison, Lawrence A. Hornak, Ilya M. Litvak, Vijaykumar Ramaswamy, Nicolas Freytag, William W. Brey

    We present the design of a novel high-temperature superconductor double-sided racetrack resonator for a 13 C optimized nuclear magnetic resonance (NMR) transmitter/receiver coil. The coils operate in a 21.1 T magnet and accommodate a 3 mm × 6.2 mm cross-section rectangular sample tube. The design includes the incorporation of revised finger lengths to improve the homogeneity of current density across the fingers, a new laser trimming approach for adjusting the resonance frequency, and improved ability to shift higher-order modes for suitability in 1 H/ 13 C NMR probes. Resonator design methodology, simulations and experimental results are presented.


  • Progress Towards a Higher Sensitivity 13C-Optimized 1.5 mm HTS NMR Probe

    by Jeremy N. Thomas, Vijaykumar Ramaswamy, Ilya M. Litvak, Taylor L. Johnston, Arthur S. Edison, William W. Brey

    Nuclear magnetic resonance (NMR) probes using thin-film high temperature superconducting (HTS) resonators offer high sensitivity and are particularly suitable for small-sample applications. We are developing an improved 1.5 mm HTS NMR probe designed for operation at 14.1 T and optimized for 13 C detection. The total sample volume is about 35 μL and the active sample volume is 20 μL. The probe employs HTS resonators for 13 C and 1 H transmission and detection and the 2 H lock. We examine the interactions of multiple superconducting resonators and normal metal tuning loops on coil resonance frequency and probe sensitivity. We test a recently introduced 13 C resonator design, engineered to significantly increase 13 C detection sensitivity over previous all-HTS probes. At zero field, we observe a 13 C quality factor of 6000 which is several times higher than previous resonators. In this work the coil design considerations and probe build-out procedure are discussed.


  • Open Access

    Modeling the Resonance Shifts Due to Coupling Between HTS Coils in NMR Probes

    by J N Thomas, V Ramaswamy, T L Johnston, D C Belc, N Freytag, L A Hornak, A S Edison, W W Brey

    Nuclear magnetic resonance (NMR) probes using thin-film HTS coils offer high sensitivity and are particularly suitable for small-sample applications. Typically, HTS probes are optimized for the detection of multiple nuclei and require several coils to be located within a small volume near the sample. Coupling between the coils shifts coil resonances and complicates coil trimming when tuning HTS probes. We have modeled the magnetic coupling between the coils of a 1.5-mm all-HTS NMR probe with 13C, 1H, and 2H channels. By measuring the magnetic coupling coefficients between individual coils, we solve the general coupling matrix given by KVL for six coupled resonators. Our results indicate that required trims can be accurately predicted by applying single coil trimming simulations to this magnetic coupling model. Use of the magnetic coupling model significantly improves the efficiency of tuning HTS probes.


  • Time and Frequency Domain Response of HTS Resonators for Use as NMR Transmit Coils

    by Ghoncheh Amouzandeh, Vijaykumar Ramaswamy, Nicolas Freytag, Arthur S. Edison, Lawrence A Hornak, William W. Brey

    Replacing normal metal NMR coils with thin-film high-temperature superconductor (HTS) resonators can significantly improve the sensitivity of analytical NMR. To study the use of these resonators for excitation as well as detection, we investigated the radio frequency properties of the HTS NMR coils in both frequency and time domain at a variety of transmit power levels. Experiments were conducted on a double-sided, counter wound spiral resonator designed to detect NMR signals from 13 C nuclei at 14.1 T. Power-dependent nonlinearity was observed in the transmission coefficient and quality factor. The ability of the HTS resonators to accurately generate short pulses was studied in the time domain over the range power levels. The results of this study show that some form of Q switching is needed to get good transmit performance from HTS coils for 13 C. For that purpose, the effect of adding a shorted transmission line stub to improve the pulse shapes and reduce phase transients was studied.


  • Open Access

    Commissioning of the 36 T Series-Connected Hybrid Magnet at the NHMFL

    by Mark D. Bird, William W. Brey, Timothy A. Cross, Iain R. Dixon, A. Griffin, Scott T. Hannahs, John Kynoch, Ilya M. Litvak, Jefferey L. Schiano, Jack Toth

    The National High Magnetic Field Laboratory (NHMFL) has commissioned a 36.1 T resistive/superconducting hybrid magnet with homogeneity and stability of 1 ppm over a 10 mm diameter spherical volume to be used for solid state NMR. Most NMR magnets use single strands of superconducting wire carrying a few hundred amps and persistent joints and switches. This mag-net uses a 20 kA superconducting cable in a steel conduit for the outer part of the magnet and copper-alloy sheet metal for the in-ner part of the magnet. While >15 hybrid magnets have been built worldwide, they typi-cally have a field uniformity of $\sim$250 ppm/cm DSV and stability might be no better than 50 ppm. To attain 1 ppm uniformity, current density grading was employed in the resistive coils to can-cel the z2 term. In addition, coils were shifted after the first map to reduce the z1 term. Ferroshims and resistive shims were in-stalled in the bore to attain <1 ppm over 10 mm. The large in-ductance of the superconducting coil reduced the ripple 6-fold compared with all-resistive magnets and essentially eliminated the 60Hz ripple and its harmonics. An NMR lock reduced the low-frequency drift to attain $\sim$0.1 ppm stability.


  • Effects of Dielectric Substrates and Ground Planes on Resonance Frequency of Archimedean Spirals

    by Jerris W. Hooker, Vijaykumar Ramaswamy, Rajendra K. Arora, Arthur S. Edison, William W. Brey

    Superconducting self-resonant spiral structures are of current interest for applications both in metamaterials and as probe coils for nuclear magnetic resonance spectroscopy for high-sensitivity chemical analysis. Accurate spiral models are available in the literature for behavior of a spiral below and up to self-resonance. However, knowledge of the higher modes is also important. We present the relationships between the spiral parameters and the multiple mode frequencies of single-sided spirals on dielectric substrates as modeled by method of moments simulation. In the absence of a ground plane, we find that the mode frequency has linear, although not necessarily harmonic, dependence on the mode number. The effect of a thick substrate can be approximated by an effective dielectric constant. However, when the thickness is less than 20% of the spiral trace width (router - rinner), this approximation is no longer accurate. We have developed a simple empirical formula to predict the higher modes.


  • Open Access

    An Empirical Expression to Predict the Resonant Frequencies of Archimedean Spirals

    by Jerris W. Hooker, Vijaykumar Ramaswamy, Rajendra K. Arora, Arthur S. Edison, Richard S. Withers, Robert E. Nast, William W. Brey

    This paper presents an empirical formula to accurately determine the frequencies of the fundamental and higher order resonances of an Archimedean spiral in a uniform dielectric medium in the absence of a ground plane. The formula is based on method-of-moments simulations, which have been experimentally validated. This empirical formula is widely applicable to a broad range of spirals from thin-ring to disk-shaped (ratio of inner to outer radii 0 to 1), with ten or more turns.


  • Development of a 13C-optimized 1.5-mm high temperature superconducting NMR probe

    by Vijaykumar Ramaswamy, Jerris W. Hooker, Richard S. Withers, Robert E. Nast, William W. Brey, Arthur S. Edison