Wenbing Su
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wenbing Su has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Lijun Wang
National Engineering Research Center of Coal Preparation and Purification, China University of Mining and Technology, Xuzhou 221116, Jiangsu, China
3 shared publicationsHaijun Zhang
School of Chemical Engineering and Technology China University of Mining and Technology Xuzhou China
2 shared publications- Xiaokang Yan
State key Laboratory of Coking Coal Resources Green Exploitation, China University of Mining and Technology, Xuzhou 221116, China
2 shared publications - Yijun Cao
Zhengzhou University
2 shared publications Chuwen Guo
School of Electric Power Engineering, China University of Mining and Technology, Xuzhou 221116, Jiangsu, China
1 shared publication- Haijun Zhang
State key Laboratory of Coking Coal Resources Green Exploitation, China University of Mining and Technology, Xuzhou 221116, China
1 shared publication
Latest Publications
- 1 November 2021
- Published by Elsevier in Minerals Engineering
- Vol. 173, 107188
Predictions of terminal rising velocity, shape and drag coefficient for particle-laden bubbles
- 1 November 2021
- Published by Elsevier in Minerals Engineering
- Vol. 173, 107188
Predictions of terminal rising velocity, shape and drag coefficient for particle-laden bubbles
- 18 December 2020
- Published by Wiley in Asia-Pacific Journal of Chemical Engineering
- Vol. 16 (2)
Comparison of bubble velocity, size, and holdup distribution between single‐ and double‐air inlet in jet microbubble generator
The jet microbubble generator is often used to produce bubbles in flotation equipment, which generates microbubbles by self‐absorbing or inflating. Bubble behavior is a dominant factor in froth flotation, and its velocity, size, and distribution greatly affect flotation performance. However, the asymmetry distribution of the pressure, bubble velocity, and gas holdup in generator with single inlet probably causes eccentric wear to the equipment. Therefore, in this study, using particle image velocimetry (PIV), high‐speed dynamic camera, and computational fluid dynamics (CFD) technology, the bubble behaviors in the jet microbubble generators with single inlet and double inlet was studied. The results show that under air flux of 0.4 L/min, the change of bubble diameter (D32) in two generators is obvious, reducing by 5.97% and 3.77% under circulation water flux of 1.5 and 2.5 m3/h, respectively. Comparing the influence of circulating water fluxes, the double‐inlet structure can reduce the bubble diameter more effectively. The maximum turbulent dissipation rate in the throat section of the generator with double inlet is greater than 120, while it is less than 100 in single‐inlet structure. For bubbles in generator with double inlet, velocity difference in radial direction reduces to 0.03 m/s and is more symmetrical. Meanwhile, the double‐inlet generator can also optimize the uniformity gas holdup distribution, which is beneficial to increase the collision probability of flotation and reduce the abrasion of microbubble generator.
- 18 December 2020
- Published by Wiley in Asia-Pacific Journal of Chemical Engineering
- Vol. 16 (2)
Comparison of bubble velocity, size, and holdup distribution between single‐ and double‐air inlet in jet microbubble generator
The jet microbubble generator is often used to produce bubbles in flotation equipment, which generates microbubbles by self‐absorbing or inflating. Bubble behavior is a dominant factor in froth flotation, and its velocity, size, and distribution greatly affect flotation performance. However, the asymmetry distribution of the pressure, bubble velocity, and gas holdup in generator with single inlet probably causes eccentric wear to the equipment. Therefore, in this study, using particle image velocimetry (PIV), high‐speed dynamic camera, and computational fluid dynamics (CFD) technology, the bubble behaviors in the jet microbubble generators with single inlet and double inlet was studied. The results show that under air flux of 0.4 L/min, the change of bubble diameter (D32) in two generators is obvious, reducing by 5.97% and 3.77% under circulation water flux of 1.5 and 2.5 m3/h, respectively. Comparing the influence of circulating water fluxes, the double‐inlet structure can reduce the bubble diameter more effectively. The maximum turbulent dissipation rate in the throat section of the generator with double inlet is greater than 120, while it is less than 100 in single‐inlet structure. For bubbles in generator with double inlet, velocity difference in radial direction reduces to 0.03 m/s and is more symmetrical. Meanwhile, the double‐inlet generator can also optimize the uniformity gas holdup distribution, which is beneficial to increase the collision probability of flotation and reduce the abrasion of microbubble generator.
- 6 May 2019
- Published by Wiley in Asia-Pacific Journal of Chemical Engineering
- Vol. 14 (3)
Effect of height of flotation column on flow field
Cyclonic‐static microbubble flotation column (FCSMC) is a sorting equipment for micro fine‐grained minerals. The column height is an important factor affecting the flotation efficiency, which will directly affect the flow field and separation performance. In this study, particle image velocimetry measurement on single phase of lab‐scale FCSMC with diameter D of 0.1 m was tested to verify the accuracy of the turbulent model used in computational fluid dynamics simulation. Then the FCSMC with different upper column and lower column height were simulated and analyzed. Results show that the axial velocity and tangential velocity play a major role in FCSMC. With the increasing of the upper column height, both tangential velocity and centrifugal intensity decrease, which help to get a static environment for column flotation unit. But too high upper column height will affect the separation of the cyclone flotation unit due to small centrifugal intensity. When the lower column height‐to‐diameter ratio H2/D increases from 1 to 4, it has no obvious effect on column flotation unit, but does effect on the flow field of the cyclone flotation unit. As the lower column height increases, the upward overflow is more prominent and the region becomes larger. Peculiarly, tangential velocity is large under too small lower column height, like H2/D = 1, but is bad for the separation of large size tailings due to low distance and great suction. Within the scope of this study, the lower column height range is more suitable for H2/D = 2–3.
- 6 May 2019
- Published by Wiley in Asia-Pacific Journal of Chemical Engineering
- Vol. 14 (3)
Effect of height of flotation column on flow field
Cyclonic‐static microbubble flotation column (FCSMC) is a sorting equipment for micro fine‐grained minerals. The column height is an important factor affecting the flotation efficiency, which will directly affect the flow field and separation performance. In this study, particle image velocimetry measurement on single phase of lab‐scale FCSMC with diameter D of 0.1 m was tested to verify the accuracy of the turbulent model used in computational fluid dynamics simulation. Then the FCSMC with different upper column and lower column height were simulated and analyzed. Results show that the axial velocity and tangential velocity play a major role in FCSMC. With the increasing of the upper column height, both tangential velocity and centrifugal intensity decrease, which help to get a static environment for column flotation unit. But too high upper column height will affect the separation of the cyclone flotation unit due to small centrifugal intensity. When the lower column height‐to‐diameter ratio H2/D increases from 1 to 4, it has no obvious effect on column flotation unit, but does effect on the flow field of the cyclone flotation unit. As the lower column height increases, the upward overflow is more prominent and the region becomes larger. Peculiarly, tangential velocity is large under too small lower column height, like H2/D = 1, but is bad for the separation of large size tailings due to low distance and great suction. Within the scope of this study, the lower column height range is more suitable for H2/D = 2–3.