Vlatko Milić
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Vlatko Milić has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Bahram Moshfegh
Division of Energy Systems, Department of Management and Engineering, Linköping University, Linköping, Sweden
3 shared publications- Bahram Moshfegh
Department of Building Engineering, Energy Systems and Sustainability Science, University of Gävle, 801 76 Gävle, Sweden
2 shared publications Patrik Rohdin
Department of Management and Engineering, Division of Energy Systems, Linköping University, Linköping, Sweden
2 shared publicationsAndreas Larsson Ståhl
Department of Management and Engineering, Division of Energy Systems, Linköping University, Linköping, Sweden
1 shared publicationAxel Granli
Department of Management and Engineering, Division of Energy Systems, Linköping University, Linköping, Sweden
1 shared publication- Božidar Benko
Division of Horticulture and Landscape Architecture, Department of Vegetable Crops, Faculty of Agriculture, University of Zagreb, 10000 Zagreb, Croatia
1 shared publication
Latest Publications
- Open Access
- 3 November 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (21) , 11181
Energy Governance and Industrial Excess Heat in Greenhouse Operations: A Case Study of Hofors, Sweden
Energy-intensive greenhouse cultivation in cold climates depends on affordable heat, suitable infrastructure, and coordination among energy utilities, industries, greenhouse operators, and municipal actors. This study investigates how local energy governance influences greenhouse operations in Hofors, Sweden, where the district heating system is partly municipally owned and supplied with recovered heat from industrial processes. A longitudinal qualitative case study approach was applied, combining field observations, stakeholder dialogues, technical information, and publicly available documents. The findings indicate that industrial excess heat and district heating return flows may offer opportunities for resource-efficient greenhouse heating using low-temperature climate control technologies. The technical feasibility of a specific connection depends on site-specific factors such as temperature conditions and infrastructure requirements. Pricing considerations, utility ownership arrangements, infrastructure limitations, and stakeholder coordination shape the conditions for realizing these opportunities. The case highlights a potential governance tension between municipal interests in energy operations and the need for reliable, predictable energy access for local businesses; the study does not quantify municipal revenues or establish a direct causal link to specific investment decisions. The results indicate that the successful integration of greenhouses into local energy systems depends not only on the technical availability of excess heat but also on pricing models, ownership structures, infrastructure planning, and cross-sector coordination. Municipal energy governance can either facilitate or constrain the integration of industrial excess heat into local greenhouse operations. The findings also suggest that, subject to technical and economic feasibility, improved access to industrial excess heat could support local greenhouse production and may contribute to regional resilience and food security in the longer term.
- 3 November 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (21) , 11181
Open AccessEnergy Governance and Industrial Excess Heat in Greenhouse Operations: A Case Study of Hofors, Sweden
Energy-intensive greenhouse cultivation in cold climates depends on affordable heat, suitable infrastructure, and coordination among energy utilities, industries, greenhouse operators, and municipal actors. This study investigates how local energy governance influences greenhouse operations in Hofors, Sweden, where the district heating system is partly municipally owned and supplied with recovered heat from industrial processes. A longitudinal qualitative case study approach was applied, combining field observations, stakeholder dialogues, technical information, and publicly available documents. The findings indicate that industrial excess heat and district heating return flows may offer opportunities for resource-efficient greenhouse heating using low-temperature climate control technologies. The technical feasibility of a specific connection depends on site-specific factors such as temperature conditions and infrastructure requirements. Pricing considerations, utility ownership arrangements, infrastructure limitations, and stakeholder coordination shape the conditions for realizing these opportunities. The case highlights a potential governance tension between municipal interests in energy operations and the need for reliable, predictable energy access for local businesses; the study does not quantify municipal revenues or establish a direct causal link to specific investment decisions. The results indicate that the successful integration of greenhouses into local energy systems depends not only on the technical availability of excess heat but also on pricing models, ownership structures, infrastructure planning, and cross-sector coordination. Municipal energy governance can either facilitate or constrain the integration of industrial excess heat into local greenhouse operations. The findings also suggest that, subject to technical and economic feasibility, improved access to industrial excess heat could support local greenhouse production and may contribute to regional resilience and food security in the longer term.
- Open Access
- 24 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 26484
Pursuing a hierarchical taxonomy in a water-cooled data center room
Despite the growing number of scientific investigations on developing taxonomies in various industries and categorizing energy end-use (EEU) processes, research on such frameworks in the data center (DC) sector remains limited, restricting systematic analysis of energy use, benchmarking, and identification of energy efficiency measures. This study seeks to achieve two key objectives: (1) to create a hierarchical taxonomy for categorizing EEU process, (2) and to identify the most relevant energy performance indicators (EnPIs). The methodology combines hierarchical classification of energy flows with quantitative analysis based on time-resolved operational data, allowing for detailed analysis of dynamic system behaviour and allocation of energy use across processes, applied to a DC room with a detached in-rack water cooling system in Sweden operated by Ericsson. The results of this paper present a novel hierarchical taxonomy for a water-cooled DC room with six defined EEU processes, of which four are related to data processing processes and two to support processes. Notably, over 99.9% of total EEU is connected to data processing processes which is a significantly higher figure compared to other production processes in other sectors. Moreover, the established EnPIs can facilitate benchmarking between DCs with similar infrastructures and for monitoring the energy use of various EEU processes. The proposed methodology is transferable to other DC environments with comparable system boundaries and data availability, and its reproducibility is supported by the structured and data-driven methodology, which enables replication of the analytical approach given comparable data availability.
- 24 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 26484
Open AccessPursuing a hierarchical taxonomy in a water-cooled data center room
Despite the growing number of scientific investigations on developing taxonomies in various industries and categorizing energy end-use (EEU) processes, research on such frameworks in the data center (DC) sector remains limited, restricting systematic analysis of energy use, benchmarking, and identification of energy efficiency measures. This study seeks to achieve two key objectives: (1) to create a hierarchical taxonomy for categorizing EEU process, (2) and to identify the most relevant energy performance indicators (EnPIs). The methodology combines hierarchical classification of energy flows with quantitative analysis based on time-resolved operational data, allowing for detailed analysis of dynamic system behaviour and allocation of energy use across processes, applied to a DC room with a detached in-rack water cooling system in Sweden operated by Ericsson. The results of this paper present a novel hierarchical taxonomy for a water-cooled DC room with six defined EEU processes, of which four are related to data processing processes and two to support processes. Notably, over 99.9% of total EEU is connected to data processing processes which is a significantly higher figure compared to other production processes in other sectors. Moreover, the established EnPIs can facilitate benchmarking between DCs with similar infrastructures and for monitoring the energy use of various EEU processes. The proposed methodology is transferable to other DC environments with comparable system boundaries and data availability, and its reproducibility is supported by the structured and data-driven methodology, which enables replication of the analytical approach given comparable data availability.
- Open Access
- 22 November 2024
- Published by Springer Nature in Sustainable Energy Research
- Vol. 11 (1) , 1-14
Exploring residential energy efficiency measures and distribution of renewable energy generation through sector interactions: a case study in Visby, Sweden
Increased use of cogeneration in district heating (DH) systems is important in the pursuit towards a low-carbon society, particularly in light of the ongoing electrification across multiple sectors. Apart from reducing CO2 emissions, cogeneration also contributes to additional income for the DH system owner. Nonetheless, it is important to be aware that the economic and environmental performance of DH systems are directly connected to the energy use within DH networks. This research investigates sector interactions associated with the introduction of a biomass combined heat and power (CHP) and residential energy renovation according to (life cycle cost) LCC optimum and Swedish energy targets, with a focus on CO2 emissions and the system cost of the energy utility company. The study object consists of a DH system in Visby, Sweden, and 920 historic residential building undergoing energy renovation. The results show a profitability of 905–915 MSEK for the DH system with the integration of a CHP. Global CO2 emissions decrease by 32.6–33.1 ktonnes/year, 9.0–9.2 ktonnes/year, and 19.9–20.1 ktonnes/year, for marginal coal-condensing power (limited biofuel), natural gas combined cycle power (limited biofuel), and European average production, respectively. In addition, sensitivity analyses confirm the benefits of cogeneration related to both economics and CO2 emissions based on changes in key parameters of the DH system.
- 22 November 2024
- Published by Springer Nature in Sustainable Energy Research
- Vol. 11 (1) , 1-14
Open AccessExploring residential energy efficiency measures and distribution of renewable energy generation through sector interactions: a case study in Visby, Sweden
Increased use of cogeneration in district heating (DH) systems is important in the pursuit towards a low-carbon society, particularly in light of the ongoing electrification across multiple sectors. Apart from reducing CO2 emissions, cogeneration also contributes to additional income for the DH system owner. Nonetheless, it is important to be aware that the economic and environmental performance of DH systems are directly connected to the energy use within DH networks. This research investigates sector interactions associated with the introduction of a biomass combined heat and power (CHP) and residential energy renovation according to (life cycle cost) LCC optimum and Swedish energy targets, with a focus on CO2 emissions and the system cost of the energy utility company. The study object consists of a DH system in Visby, Sweden, and 920 historic residential building undergoing energy renovation. The results show a profitability of 905–915 MSEK for the DH system with the integration of a CHP. Global CO2 emissions decrease by 32.6–33.1 ktonnes/year, 9.0–9.2 ktonnes/year, and 19.9–20.1 ktonnes/year, for marginal coal-condensing power (limited biofuel), natural gas combined cycle power (limited biofuel), and European average production, respectively. In addition, sensitivity analyses confirm the benefits of cogeneration related to both economics and CO2 emissions based on changes in key parameters of the DH system.
- Open Access
- 9 October 2024
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 12, 1443974
Exploring small-scale direct air capture in a building ventilation system: a case study in Linköping, Sweden
Direct Air Capture (DAC) technologies have emerged as a promising solution to address climate change and meet global climate goals. However, despite the importance of DAC in designing carbon-negative buildings, there is a lack of research focusing on the energy and cost aspects in building ventilation systems. The objective of this research is to investigate the CO2 capture potential and economic viability of integrating small-scale DAC into a building ventilation system integrated within a gym space. A gym space located in the city of Linköping, Sweden, is used as the research object. Furthermore, the study investigates the CO2 capture potential across a portfolio of gym spaces corresponding to an area of 24,760 m2. The results show that the CO2 capture potential varies between 54 kg/day and 83 kg/day for the investigated gym space. Moreover, the total CO2 capture potential is between 588 ton CO2/year and 750 ton CO2/year for the portfolio of gym spaces. The results also demonstrate that regenerating the sorbent during non-operating hours is more energy-efficient and economically advantageous compared to performing four complete regeneration cycles during operating hours. Based on a sorbent capture potential of 0.2 mmol/g and 2.0 mmol/g, and a CO2 price of 1,000 SEK, the break-even price for energy is 0.25–0.53 SEK/kWh. Lastly, the research shows that, among the investigated cases, the only economically viable solution corresponds to sorbent capture potential 2.0 mmol/g and utilizing low-grade heat for the generation process, resulting in a total cost of 663 SEK/ton CO2.
- 9 October 2024
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 12, 1443974
Open AccessExploring small-scale direct air capture in a building ventilation system: a case study in Linköping, Sweden
Direct Air Capture (DAC) technologies have emerged as a promising solution to address climate change and meet global climate goals. However, despite the importance of DAC in designing carbon-negative buildings, there is a lack of research focusing on the energy and cost aspects in building ventilation systems. The objective of this research is to investigate the CO2 capture potential and economic viability of integrating small-scale DAC into a building ventilation system integrated within a gym space. A gym space located in the city of Linköping, Sweden, is used as the research object. Furthermore, the study investigates the CO2 capture potential across a portfolio of gym spaces corresponding to an area of 24,760 m2. The results show that the CO2 capture potential varies between 54 kg/day and 83 kg/day for the investigated gym space. Moreover, the total CO2 capture potential is between 588 ton CO2/year and 750 ton CO2/year for the portfolio of gym spaces. The results also demonstrate that regenerating the sorbent during non-operating hours is more energy-efficient and economically advantageous compared to performing four complete regeneration cycles during operating hours. Based on a sorbent capture potential of 0.2 mmol/g and 2.0 mmol/g, and a CO2 price of 1,000 SEK, the break-even price for energy is 0.25–0.53 SEK/kWh. Lastly, the research shows that, among the investigated cases, the only economically viable solution corresponds to sorbent capture potential 2.0 mmol/g and utilizing low-grade heat for the generation process, resulting in a total cost of 663 SEK/ton CO2.
- Open Access
- 10 September 2024
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 12, 1449358
Next-generation data center energy management: a data-driven decision-making framework
In the era of society’s ongoing digitization and the exponential growth in data volume, alongside a growing energy demand, energy management plays an integral role in data centers (DCs) and is a key factor in the quest for decarbonization. In light of the complex nature of DCs, traditional energy management strategies are inadequate. This research introduces a data-driven decision-making framework for DCs, grounded in the OODA (Observation, Orientation, Decision, and Action) loop and based on insights from an Ericsson-operated DC in Linköping, Sweden. The developed framework enables DCs to enhance energy efficiency effectively. Rooted in the OODA loop and leveraging extensive datasets from DCs’ building management systems, this framework aids in decreasing cooling energy usage through strategic, data-driven decision-making. By adopting AI methods, specifically K-means clustering in this research, for continuous monitoring and fine-tuning (Proportional, Integral, Derivative) PID parameters, the framework aids in improving operational efficiency.
- 10 September 2024
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 12, 1449358
Open AccessNext-generation data center energy management: a data-driven decision-making framework
In the era of society’s ongoing digitization and the exponential growth in data volume, alongside a growing energy demand, energy management plays an integral role in data centers (DCs) and is a key factor in the quest for decarbonization. In light of the complex nature of DCs, traditional energy management strategies are inadequate. This research introduces a data-driven decision-making framework for DCs, grounded in the OODA (Observation, Orientation, Decision, and Action) loop and based on insights from an Ericsson-operated DC in Linköping, Sweden. The developed framework enables DCs to enhance energy efficiency effectively. Rooted in the OODA loop and leveraging extensive datasets from DCs’ building management systems, this framework aids in decreasing cooling energy usage through strategic, data-driven decision-making. By adopting AI methods, specifically K-means clustering in this research, for continuous monitoring and fine-tuning (Proportional, Integral, Derivative) PID parameters, the framework aids in improving operational efficiency.
- Open Access
- 2 March 2023
- Published by Taylor & Francis in Advances in Building Energy Research
- Vol. 17 (3) , 255-276
Screening of thermal characteristics and assessment of comparative energy efficiency potential in a residential district
By identifying buildings with poor thermal performance and prioritizing these in terms of energy efficiency potential, a sustainable transformation of the building stock may be accelerated. However, there is currently a lack of thermal characteristics (TCs) differentiating total energy use from hot water circulation (HWC), hot tap water (HTW) and space heating in large building portfolios. This research demonstrates a methodology based on a change-point model for identifying and prioritizing TCs, which also enables prediction of the Comparative Energy Efficiency Potential (CEEP). The change-point model allows for the differentiation of various processes, i.e. space heating, HWC and HTW, using only heating supply data and outdoor temperature. The studied district consists of 70 multi-family buildings in the Vasastaden district in Linköping, Sweden. The findings demonstrate that the proposed methodology allows for identifying and prioritizing TCs connected to HWC, HTW and space heating. The highest CEEP is in space heating, corresponding to a maximum of 2,016 MWh (16% of the district’s energy use), followed by HWC, 699 MWh (6% of the district’s energy use) and HTW, 520 MWh (4% of the district’s energy use). Consequently, a total decrease of 3,235 MWh (26%) is made possible according to the studied energy efficiency targets.
- 2 March 2023
- Published by Taylor & Francis in Advances in Building Energy Research
- Vol. 17 (3) , 255-276
Open AccessScreening of thermal characteristics and assessment of comparative energy efficiency potential in a residential district
By identifying buildings with poor thermal performance and prioritizing these in terms of energy efficiency potential, a sustainable transformation of the building stock may be accelerated. However, there is currently a lack of thermal characteristics (TCs) differentiating total energy use from hot water circulation (HWC), hot tap water (HTW) and space heating in large building portfolios. This research demonstrates a methodology based on a change-point model for identifying and prioritizing TCs, which also enables prediction of the Comparative Energy Efficiency Potential (CEEP). The change-point model allows for the differentiation of various processes, i.e. space heating, HWC and HTW, using only heating supply data and outdoor temperature. The studied district consists of 70 multi-family buildings in the Vasastaden district in Linköping, Sweden. The findings demonstrate that the proposed methodology allows for identifying and prioritizing TCs connected to HWC, HTW and space heating. The highest CEEP is in space heating, corresponding to a maximum of 2,016 MWh (16% of the district’s energy use), followed by HWC, 699 MWh (6% of the district’s energy use) and HTW, 520 MWh (4% of the district’s energy use). Consequently, a total decrease of 3,235 MWh (26%) is made possible according to the studied energy efficiency targets.
- Open Access
- 27 November 2020
- Published by Elsevier in Energy and Buildings
- Vol. 231, 110639
Further development of the change-point model – Differentiating thermal power characteristics for a residential district in a cold climate
- 27 November 2020
- Published by Elsevier in Energy and Buildings
- Vol. 231, 110639
Open AccessFurther development of the change-point model – Differentiating thermal power characteristics for a residential district in a cold climate
- Open Access
A Systematic Approach to Predict the Economic and Environmental Effects of the Cost-Optimal Energy Renovation of a Historic Building District on the District Heating System
The economic and environmental performance of a district heating (DH) system is to a great extent affected by the size and dynamic behavior of the DH load. By implementing energy efficiency measures (EEMs) to increase a building’s thermal performance and by performing cost-optimal energy renovation, the operation of the DH system will be altered. This study presents a systematic approach consisting of building categorization, life cycle cost (LCC) optimization, building energy simulation and energy system optimization procedures, investigating the profitability and environmental performance of cost-optimal energy renovation of a historic building district on the DH system. The results show that the proposed approach can successfully be used to predict the economic and environmental effects of cost-optimal energy renovation of a building district on the local DH system. The results revealed that the financial gains of the district are between 186 MSEK (23%) and 218 MSEK (27%) and the financial losses for the DH system vary between 117–194 MSEK (5–8%). However, the suggested renovation measures decrease the local and global CO2 emissions by 71–75 metric ton of CO2eq./year (4%) and 3545–3727 metric ton of CO2eq./year (41–43%), respectively. Total primary energy use was decreased from 57.2 GWh/year to 52.0–52.2 GWh/year.
Open AccessA Systematic Approach to Predict the Economic and Environmental Effects of the Cost-Optimal Energy Renovation of a Historic Building District on the District Heating System
The economic and environmental performance of a district heating (DH) system is to a great extent affected by the size and dynamic behavior of the DH load. By implementing energy efficiency measures (EEMs) to increase a building’s thermal performance and by performing cost-optimal energy renovation, the operation of the DH system will be altered. This study presents a systematic approach consisting of building categorization, life cycle cost (LCC) optimization, building energy simulation and energy system optimization procedures, investigating the profitability and environmental performance of cost-optimal energy renovation of a historic building district on the DH system. The results show that the proposed approach can successfully be used to predict the economic and environmental effects of cost-optimal energy renovation of a building district on the local DH system. The results revealed that the financial gains of the district are between 186 MSEK (23%) and 218 MSEK (27%) and the financial losses for the DH system vary between 117–194 MSEK (5–8%). However, the suggested renovation measures decrease the local and global CO2 emissions by 71–75 metric ton of CO2eq./year (4%) and 3545–3727 metric ton of CO2eq./year (41–43%), respectively. Total primary energy use was decreased from 57.2 GWh/year to 52.0–52.2 GWh/year.