Patrick Carnahan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Patrick Carnahan has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Elvis C. S. Chen
Department of Medical Biophysics, Robarts Research Institute, Western University, London, ON, Canada
3 shared publications John Moore
3 shared publicationsDaniel Bainbridge
Western University
2 shared publicationsMehdi Eskandari
King’s College Hospital
2 shared publicationsTerry M. Peters
Imaging Laboratories, Robarts Research Institute
2 shared publications- Terry M. Peters
Robarts Research Institute, Western University, London, Canada
2 shared publications
Latest Publications
- Open Access
- 2 April 2026
- Published by Elsevier in JTCVS Open
- Vol. 31
Physically validated mitral valve models for surgical simulation: Bridging anatomy, pathology, and practice
- 2 April 2026
- Published by Elsevier in JTCVS Open
- Vol. 31
Open AccessPhysically validated mitral valve models for surgical simulation: Bridging anatomy, pathology, and practice
- Open Access
- 30 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (9) , 4562
Multi-View 3D Transesophageal Echocardiography Registration and Volume Compounding for Mitral Valve Procedure Planning
Three-dimensional ultrasound mosaicing can increase image quality and expand the field of view. However, limited work has been done applying these compounded approaches for cardiac procedures focused on the mitral valve. For procedures targeting the mitral valve, transesophageal echocardiography (TEE) is the primary imaging modality used as it provides clear 3D images of the valve and surrounding tissues. However, TEE suffers from image artefacts and signal dropout, particularly for structures lying below the valve, including chordae tendineae, making it necessary to acquire alternative echo views to visualize these structures. Due to the limited field of view obtainable, the entire ventricle cannot be directly visualized in sufficient detail from a single image acquisition in 3D. We propose applying an image compounding technique to TEE volumes acquired from a mid-esophageal position and several transgastric positions in order to reconstruct a high-detail volume of the mitral valve and sub-valvular structures. This compounding technique utilizes both fully and semi-simultaneous group-wise registration to align the multiple 3D volumes, followed by a weighted intensity compounding step based on the monogenic signal. This compounding technique is validated using images acquired from two excised porcine mitral valve units and three patient data sets. We demonstrate that this compounding technique accurately captures the physical structures present, including the mitral valve, chordae tendineae and papillary muscles. The chordae length measurement error between the compounded ultrasound and ground-truth CT for two porcine valves is reported as 0.7 ± 0.6 mm and 0.6 ± 0.6 mm.
- 30 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (9) , 4562
Open AccessMulti-View 3D Transesophageal Echocardiography Registration and Volume Compounding for Mitral Valve Procedure Planning
Three-dimensional ultrasound mosaicing can increase image quality and expand the field of view. However, limited work has been done applying these compounded approaches for cardiac procedures focused on the mitral valve. For procedures targeting the mitral valve, transesophageal echocardiography (TEE) is the primary imaging modality used as it provides clear 3D images of the valve and surrounding tissues. However, TEE suffers from image artefacts and signal dropout, particularly for structures lying below the valve, including chordae tendineae, making it necessary to acquire alternative echo views to visualize these structures. Due to the limited field of view obtainable, the entire ventricle cannot be directly visualized in sufficient detail from a single image acquisition in 3D. We propose applying an image compounding technique to TEE volumes acquired from a mid-esophageal position and several transgastric positions in order to reconstruct a high-detail volume of the mitral valve and sub-valvular structures. This compounding technique utilizes both fully and semi-simultaneous group-wise registration to align the multiple 3D volumes, followed by a weighted intensity compounding step based on the monogenic signal. This compounding technique is validated using images acquired from two excised porcine mitral valve units and three patient data sets. We demonstrate that this compounding technique accurately captures the physical structures present, including the mitral valve, chordae tendineae and papillary muscles. The chordae length measurement error between the compounded ultrasound and ground-truth CT for two porcine valves is reported as 0.7 ± 0.6 mm and 0.6 ± 0.6 mm.
- 21 September 2021
- Published by Springer Nature
- p. 459-468
DeepMitral: Fully Automatic 3D Echocardiography Segmentation for Patient Specific Mitral Valve Modelling
- 21 September 2021
- Published by Springer Nature
- p. 459-468
DeepMitral: Fully Automatic 3D Echocardiography Segmentation for Patient Specific Mitral Valve Modelling
- 30 May 2019
- Published by Springer Nature
- p. 397-404
Interactive-Automatic Segmentation and Modelling of the Mitral Valve
- 30 May 2019
- Published by Springer Nature
- p. 397-404
Interactive-Automatic Segmentation and Modelling of the Mitral Valve
- 8 May 2019
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 14 (7) , 1207-1215
Accuracy assessment for the co-registration between optical and VIVE head-mounted display tracking
We report on the development and accuracy assessment of a hybrid tracking system that integrates optical spatial tracking into a video pass-through head-mounted display.
- 8 May 2019
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 14 (7) , 1207-1215
Accuracy assessment for the co-registration between optical and VIVE head-mounted display tracking
We report on the development and accuracy assessment of a hybrid tracking system that integrates optical spatial tracking into a video pass-through head-mounted display.