PKPragya Kosta

Pragya Kosta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Pragya Kosta has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Characterization of Induced Current Density During Transcorneal Electrical Stimulation to Promote Neuroprotection in the Degenerating Retina

    by Ege Iseri, Pragya Kosta, Dimitrios Pollalis, Pei-An Lo, Ben Yi Tew, Stan Louie, Bodour Salhia, Mark Humayun, Gianluca Lazzi

    Objective: Transcorneal electrical stimulation (TES) is a promising approach to delay retinal degeneration by inducing extracellular electric field-driven neuroprotective effects within photoreceptors. Although achieving precise electric field control is feasible in vitro, characterizing these fields becomes intricate and largely unexplored in vivo due to uneven distribution in the heterogeneous body. In this paper, we investigate and characterize electric fields within the retina during TES to assess the potential for therapeutic approaches Methods: We developed a computational model of a rat's head, enabling us to generate predictive simulations of the voltage and current density induced in the retina. Subsequently, an in vivo experimental setup involving Royal College of Surgeon (RCS) rats was implemented to measure the voltage across the retina using identical electrode configurations as employed in the simulations. Results: A stimulation amplitude of 0.2–0.3 mA may be necessary during TES in rats to induce a current density of at least 20 A/ ${{{\bm{m}}}^2}$ in the retina, which is the lower limit for triggering neuroprotective effects according to culture studies on neural cells. Measurement taken from cadaveric pigs’ eyes revealed that a stimulation amplitude of 1 mA is necessary for achieving the same current density. Conclusion: The computational modeling approach presented in this study was validated with experimental data and can be leveraged for predictive simulations to optimize the electrode design and stimulation parameters of TES. Significance: Once validated, the flexibility and low research cost of computational models are valuable in optimization studies where testing on live subjects is not feasible.


  • Open Access

    HISTOLOGICAL EFFECTS OF PROLONGED ELECTRICAL STIMULATION OF PERIPHERAL NERVES WITH CUFF ELECTRODES

    by Gloria Ruiz Boix, Gema Martinez Navarrete, Andres Morales, Jinze Du, Pragya Kosta, Jean-Marie Bouteiller, David Warren, Gianluca Lazzi, Eduardo Fernández Jover

  • Open Access

    Impact of Retinal Degeneration on Response of ON and OFF Cone Bipolar Cells to Electrical Stimulation

    by Shayan Farzad, Pragya Kosta, Ege Iseri, Steven T. Walston, Jean-Marie C. Bouteiller, Rebecca L. Pfeiffer, Crystal L. Sigulinsky, Jia-Hui Yang, Jessica C. Garcia, James R. Anderson, et al.

    In retinal degenerative diseases, such as retinitis pigmentosa (RP) and age-related macular degeneration (AMD), the photoreceptors become stressed and start to degenerate in the early stages of the disease. Retinal prosthetic devices have been developed to restore vision in patients by applying electrical stimulation to the surviving retinal cells. However, these devices provide limited visual perception as the therapeutic interventions are generally considered in the later stages of the disease when only inner retinal layer cells are left. A potential treatment option for retinal degenerative diseases in the early stages can be stimulating bipolar cells, which receive presynaptic signals from photoreceptors. In this work, we constructed computational models of healthy and degenerated (both ON and OFF-type) cone bipolar cells (CBCs) with realistic morphologies extracted from connectomes of the healthy and early-stage degenerated rabbit retina. We examined these cells’ membrane potential and axon terminal calcium current differences when subjected to electrical stimulation. In addition, we investigated how differently healthy and degenerated cells behave with respect to various stimulation parameters, including pulse duration and cells’ distance from the stimulating electrode. The results suggested that regardless of the position of the OFF CBCs in the retina model, there is not a significant difference between the membrane potential of healthy and degenerate cells when electrically stimulated. However, the healthy ON CBC axon terminal membrane potential rising time-constant is shorter (0.29 ± 0.03 ms) than the degenerated cells (0.8 ± 0.07 ms). Moreover, the ionic calcium channels at the axon terminals of the cells have a higher concentration and higher current in degenerated cells (32.24 ± 6.12 pA) than the healthy cells (13.64 ± 2.88 pA) independently of the cell’s position.


  • Rectifier Design for Highly Loaded Inductive Wireless Power Transfer Systems for Biomedical Applications

    by Manjunath Machnoor, Pragya Kosta, Manuel Monge, Gianluca Lazzi

    Power transfer efficiency (PTE) and harmonics are crucial performance parameters of the resonant rectifier design for low/medium coupling inductive wireless power transfer (WPT) systems used in wireless biomedical implants. The performance of a resonant rectifier degrades under higher loading and lower coupling conditions as the voltage available to the rectifier at the output of the receiver coil becomes low. As the diode turn-on impedance increases, diodes turn on incompletely, leading to non-linearities that reduce rectifier efficiency and output voltage. This work proposes a new rectifier design to increase efficiency and reduce harmonics by decreasing the diode turn-on impedance compared to traditional rectifier designs, such as resonant Half Wave Rectifier (HWR). The proposed rectifier design offers individual paths for RF and rectification signals, which reduces the non-linear loading on the receiver coil and improves diode turn-on performance. Measurement and SPICE simulation results show efficiency enhancement of 50% and reduction of harmonics by 6 dB for the proposed rectifier compared to HWR.


  • Electrical Stimulation Induced Current Distribution in Peripheral Nerves Varies Significantly with the Extent of Nerve Damage: A Computational Study Utilizing Convolutional Neural Network and Realistic Nerve Models

    by Jinze Du, Andres Morales, Pragya Kosta, Jean-Marie C. Bouteiller, Gema Martinez, David Warren, Eduardo Fernandez, Gianluca Lazzi

    Although electrical stimulation is an established treatment option for multiple central nervous and peripheral nervous system diseases, its effects on the tissue and subsequent safety of the stimulation are not well understood. Therefore, it is crucial to design stimulation protocols that maximize therapeutic efficacy while avoiding any potential tissue damage. Further, the stimulation levels need to be adjusted regularly to ensure that they are safe even with the changes to the nerve due to long-term stimulation. Using the latest advances in computing capabilities and machine learning approaches, we developed computational models of peripheral nerve stimulation based on very high-resolution cross-sectional images of the nerves. We generated nerve models constructed from non-stimulated (healthy) and over-stimulated (damaged) rat sciatic nerves to examine how the current density distribution is affected by nerve damage. Using our in-house numerical solver, the Admittance Method (AM), we computed the induced current distribution inside the nerves and compared the current penetration for healthy and damaged nerves. Our computational results indicate that when the nerve is damaged, primarily evidenced by the decreased nerve fiber packing, the current penetrates deeper inside the nerve than in the healthy case. As safety limits for electrical stimulation of biological tissue are still debated, we ultimately aim to utilize our computational models to determine refined safety criteria and help design safer and more efficacious electrical stimulation protocols. Keywords Computational modeling Electrical stimulation Peripheral nerve Tissue safety


  • Mechanisms underlying activation of retinal bipolar cells through targeted electrical stimulation: a computational study

    by Javad Paknahad, Pragya Kosta, Jean-Marie C Bouteiller, Mark S Humayun, Gianluca Lazzi

    Objective . Retinal implants have been developed to electrically stimulate healthy retinal neurons in the progressively degenerated retina. Several stimulation approaches have been proposed to improve the visual percept induced in patients with retinal prostheses. We introduce a computational model capable of simulating the effects of electrical stimulation on retinal neurons. Leveraging this computational platform, we delve into the underlying mechanisms influencing the sensitivity of retinal neurons’ response to various stimulus waveforms. Approach . We implemented a model of spiking bipolar cells (BCs) in the magnocellular pathway of the primate retina, diffuse BC subtypes (DB4), and utilized our multiscale admittance method (AM)-NEURON computational platform to characterize the response of BCs to epiretinal electrical stimulation with monophasic, symmetric, and asymmetric biphasic pulses. Main results . Our investigations yielded four notable results: (a) the latency of BCs increases as stimulation pulse duration lengthens; conversely, this latency decreases as the current amplitude increases. (b) Stimulation with a long anodic-first symmetric biphasic pulse (duration > 8 ms) results in a significant decrease in spiking threshold compared to stimulation with similar cathodic-first pulses (from 98.2 to 57.5 µ A). (c) The hyperpolarization-activated cyclic nucleotide-gated channel was a prominent contributor to the reduced threshold of BCs in response to long anodic-first stimulus pulses. (d) Finally, extending the study to asymmetric waveforms, our results predict a lower BCs threshold using asymmetric long anodic-first pulses compared to that of asymmetric short cathodic-first stimulation. Significance . This study predicts the effects of several stimulation parameters on spiking BCs response to electrical stimulation. Of importance, our findings shed light on mechanisms underlying the experimental observations from the literature, thus highlighting the capability of the methodology to predict and guide the development of electrical stimulation protocols to generate a desired biological response, thereby constituting an ideal testbed for the development of electroceutical devices.


  • Model-based comparison of current flow in rod bipolar cells of healthy and early-stage degenerated retina

    by Pragya Kosta, Ege Iseri, Kyle Loizos, Javad Paknahad, Rebecca L. Pfeiffer, Crystal L. Sigulinsky, James R. Anderson, Bryan W. Jones, Gianluca Lazzi


  • Simulation-Based Optimization of Figure-of-Eight Coil Designs and Orientations for Magnetic Stimulation of Peripheral Nerve

    by Pragya Kosta, John Mize, David J. Warren, Gianluca Lazzi

    Although magnetic neural stimulation has many advantages over electrical neural stimulation, its main disadvantages are higher energy requirement and poor stimulation selectivity. The orientation and location of the coil with respect to the stimulation site play a critical role in determining the stimulation threshold and stimulation selectivity. Utilizing numerical simulations in this work, we optimized the design parameters, orientation, and positioning of magnetic coils with respect to the peripheral nerve for improved stimulation efficacy. Specifically, we investigated different orientations and positions of the figureof- eight coils for neural stimulation of the rat sciatic nerve. We also examined the effect of coil design parameters (number of layers and turns) and different coil electrical configurations (opposite vs. same direction of coil currents and series vs. parallel coil connections) on the stimulation threshold. We leveraged the multi-resolution impedance method and a heterogeneous multifascicular anatomical model of rat sciatic nerve to explore the possibility of selective stimulation as well. Neural excitation of a nerve fiber was implemented by an equivalent cable model and Frankenhaeuser-Huxley equations using NEURON software. Results suggest that inter-fascicular selectivity could be achieved by properly orienting and positioning the coil with respect to the nerve. Further, by orienting the figure-of-eight coil at an angle of 90° and 6 mm offset, we could switch between primarily activating one fascicle (and barely activating the other) and reversing those roles by merely switching the current direction in the two coils of the figure-of-eight coil.


  • Open Access

    Stimulus waveform design for decreasing charge and increasing stimulation selectivity in retinal prostheses

    by Pragya Kosta, Kyle Loizos, Gianluca Lazzi

    Retinal degenerative diseases, such as retinitis pigmentosa, begin with damage to the photoreceptor layer of the retina. In the absence of presynaptic input from photoreceptors, networks of electrically coupled AII amacrine and cone bipolar cells have been observed to exhibit oscillatory behaviour and result in spontaneous firing of ganglion cells. This ganglion cell activity could interfere with external stimuli provided by retinal prosthetic devices and potentially degrade their performance. In this work, the authors computationally investigate stimulus waveform designs, which can improve the performance of retinal prostheses by suppressing undesired spontaneous firing of ganglion cells and generating precise temporal spiking patterns. They utilise a multi‐scale computational model for electrical stimulation of degenerated retina based on the admittance method and NEURON simulation environments. They present a class of asymmetric biphasic pulses that can generate precise ganglion cell firing patterns with up to 55% lower current requirements compared to traditional symmetric biphasic pulses. This lower current results in activation of only proximal ganglion cells, provides more focused stimulation and lowers the risk of tissue damage.


  • Recent Advances in Computational and Experimental Bioelectromagnetics for Neuroprosthetics

    by John Stang, Gianluca Lazzi, Guanbo Chen, Pragya Kosta, Javad Paknahad, Manjunath Machnoor, Ege Iseri, Jinze Du, Danilo Brizi, Kyle Loizos

    Our group has developed a modular computational framework that integrates in space and time: (1) an admittance/impedance (AM/IM) multiresolution method capable of predicting currents induced in microscale models of nerves due to neurostimulators of arbitrary geometry with (2) a neural simulation environment (NEURON) capable of predicting nerve excitation. This integration is achieved by coupling high-resolution electromagnetic field solutions from our in-house AM/IM solver with neuronal anatomy and biophysics models implemented in NEURON. Furthermore, this AM/IM/NEURON platform utilizes advanced parallel processing and shared memory techniques to optimize computation times and data transfer rates between the two solvers. Leveraging the capabilities of this platform, our group has undertaken a variety of studies ranging from fundamental neuroscience to applied neuroprosthethic design with the common thread of linking our AM/IM/NEURON computational modeling with experimental data to analyze signaling pathways, test hypotheses, and to guide and validate prosthetic designs.