Fernanda Augustini Rigon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Fernanda Augustini Rigon has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Alexandre Hohl
Universidade Federal de Santa Catarina (UFSC)
3 shared publications - Marcelo Fernando Ronsoni
Department of Medicine Universidade Federal de Santa Catarina Florianópolis Santa Catarina Brazil
2 shared publications - Simone van de Sande-Lee
Universidade Federal de Santa Catarina
2 shared publications - Andre Gustavo Daher Vianna
Curitiba Diabetes Center, Department of Endocrine Diseases, Hospital Nossa Senhora das Graças, Curitiba, Brazil
1 shared publication André Gustavo Daher Vianna
Curitiba Diabetes Center, Department of Endocrine Diseases, Hospital Nossa Senhora das Graças, Curitiba, Brazil
1 shared publicationLeonardo de Lucca Schiavon
Department of Internal Medicine, Federal University of Santa Catarina, Florianópolis, Brazil
1 shared publication
Latest Publications
- 4 March 2024
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 19 (4) , 1023-1034
Intermittently Scanned Continuous Glucose Monitoring Performance in Patients With Liver Cirrhosis
Aim: To evaluate the use of intermittently scanned continuous glucose monitoring (isCGM) in patients with liver cirrhosis (LC). Methods: Observational study including 30 outpatients with LC (Child-Pugh B/C): 10 without diabetes (DM) (G1), 10 with newly diagnosed DM by oral glucose tolerance test (G2), and 10 with a previous DM diagnosis (G3). isCGM (FreeStyle Libre Pro) was used for 56 days (four sensors/patient). Blood tests were performed at baseline and after 28 and 56 days. Results: No differences were found in the baseline characteristics, except for higher age in G3. There were significant differences between G1, G2 and G3 in glucose management indicator (GMI) (5.28 ± 0.17, 6.03 ± 0.59, 6.86 ± 1.08%, P < .001), HbA1c (4.82 ± 0.39, 5.34 ± 1.26, 6.97 ± 1.47%, P < .001), average glucose (82.79 ± 7.06, 113.39 ± 24.32, 149.14 ± 45.31mg/dL, P < .001), time in range (TIR) (70.89 ± 9.76, 80.2 ± 13.55, 57.96 ± 17.96%, P = .006), and glucose variability (26.1 ± 5.0, 28.21 ± 5.39, 35.31 ± 6.85%, P = .004). There was discordance between GMI and HbA1c when all groups were considered together, with a mean difference of 0.35% (95% SD 0.17, 0.63). In G1, the mean difference was 0.46% (95% SD 0.19, 0.73) and in G2 0.69% (95% SD 0.45, 1.33). GMI and HbA1c were concordant in G3, with a mean difference of −0.10 % (95% SD [−0.59, 0.38]). Conclusion: Disagreements were found between the GMI and HbA1c levels in patients with LC. isCGM was able to detect abnormalities in glycemic control that would not be detected by monitoring with HbA1c, suggesting that isCGM can be useful in assessing glycemic control in patients with LC.
- 4 March 2024
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 19 (4) , 1023-1034
Intermittently Scanned Continuous Glucose Monitoring Performance in Patients With Liver Cirrhosis
Aim: To evaluate the use of intermittently scanned continuous glucose monitoring (isCGM) in patients with liver cirrhosis (LC). Methods: Observational study including 30 outpatients with LC (Child-Pugh B/C): 10 without diabetes (DM) (G1), 10 with newly diagnosed DM by oral glucose tolerance test (G2), and 10 with a previous DM diagnosis (G3). isCGM (FreeStyle Libre Pro) was used for 56 days (four sensors/patient). Blood tests were performed at baseline and after 28 and 56 days. Results: No differences were found in the baseline characteristics, except for higher age in G3. There were significant differences between G1, G2 and G3 in glucose management indicator (GMI) (5.28 ± 0.17, 6.03 ± 0.59, 6.86 ± 1.08%, P < .001), HbA1c (4.82 ± 0.39, 5.34 ± 1.26, 6.97 ± 1.47%, P < .001), average glucose (82.79 ± 7.06, 113.39 ± 24.32, 149.14 ± 45.31mg/dL, P < .001), time in range (TIR) (70.89 ± 9.76, 80.2 ± 13.55, 57.96 ± 17.96%, P = .006), and glucose variability (26.1 ± 5.0, 28.21 ± 5.39, 35.31 ± 6.85%, P = .004). There was discordance between GMI and HbA1c when all groups were considered together, with a mean difference of 0.35% (95% SD 0.17, 0.63). In G1, the mean difference was 0.46% (95% SD 0.19, 0.73) and in G2 0.69% (95% SD 0.45, 1.33). GMI and HbA1c were concordant in G3, with a mean difference of −0.10 % (95% SD [−0.59, 0.38]). Conclusion: Disagreements were found between the GMI and HbA1c levels in patients with LC. isCGM was able to detect abnormalities in glycemic control that would not be detected by monitoring with HbA1c, suggesting that isCGM can be useful in assessing glycemic control in patients with LC.
- Open Access
- 3 June 2022
- Published by Archives of Endocrinology and Metabolism in Archives of Endocrinology and Metabolism
- Vol. 66 (6) , 883-894
Flash glucose monitoring system in special situations
The management of diabetes mellitus (DM) requires maintaining glycemic control, and patients must keep their blood glucose levels close to the normal range to reduce the risk of microvascular complications and cardiovascular events. While glycated hemoglobin (A1C) is currently the primary measure for glucose management and a key marker for long-term complications, it does not provide information on acute glycemic excursions and overall glycemic variability. These limitations may even be higher in some special situations, thereby compromising A1C accuracy, [...] ABSTRACT The management of diabetes mellitus (DM) requires maintaining glycemic control, and patients must keep their blood glucose levels close to the normal range to reduce the risk of microvascular complications and cardiovascular events. While glycated hemoglobin (A1C) is currently the primary measure for glucose management and a key marker for long-term complications, it does not provide information on acute glycemic excursions and overall glycemic variability. These limitations may even be higher in some special situations, thereby compromising A1C accuracy,
- 3 June 2022
- Published by Archives of Endocrinology and Metabolism in Archives of Endocrinology and Metabolism
- Vol. 66 (6) , 883-894
Open AccessFlash glucose monitoring system in special situations
The management of diabetes mellitus (DM) requires maintaining glycemic control, and patients must keep their blood glucose levels close to the normal range to reduce the risk of microvascular complications and cardiovascular events. While glycated hemoglobin (A1C) is currently the primary measure for glucose management and a key marker for long-term complications, it does not provide information on acute glycemic excursions and overall glycemic variability. These limitations may even be higher in some special situations, thereby compromising A1C accuracy, [...] ABSTRACT The management of diabetes mellitus (DM) requires maintaining glycemic control, and patients must keep their blood glucose levels close to the normal range to reduce the risk of microvascular complications and cardiovascular events. While glycated hemoglobin (A1C) is currently the primary measure for glucose management and a key marker for long-term complications, it does not provide information on acute glycemic excursions and overall glycemic variability. These limitations may even be higher in some special situations, thereby compromising A1C accuracy,
- 7 May 2019
- Published by Springer Nature in Obesity Surgery
- Vol. 29 (7) , 2115-2125
Effects of Bariatric Surgery in Male Obesity-Associated Hypogonadism
The prevalence of obesity has grown exponentially over the last several decades. Research has linked male obesity to changes in the gonadal axis, which can induce functional hypogonadism. Bariatric surgery provides sustained weight loss and metabolic improvement. This was a retrospective cohort study to evaluate the male gonadal axis and metabolic profiles of obese individuals during the bariatric pre- and post-operative periods while comparing them to a normal body mass index (BMI) group.
- 7 May 2019
- Published by Springer Nature in Obesity Surgery
- Vol. 29 (7) , 2115-2125
Effects of Bariatric Surgery in Male Obesity-Associated Hypogonadism
The prevalence of obesity has grown exponentially over the last several decades. Research has linked male obesity to changes in the gonadal axis, which can induce functional hypogonadism. Bariatric surgery provides sustained weight loss and metabolic improvement. This was a retrospective cohort study to evaluate the male gonadal axis and metabolic profiles of obese individuals during the bariatric pre- and post-operative periods while comparing them to a normal body mass index (BMI) group.