Tania Casal
Tania Casal has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
- Riho Vendt
Tartu Observatory, University of Tartu, 61602 Tõravere, Estonia
7 shared publications - Viktor Vabson
Tartu Observatory, University of Tartu, 61602 Tõravere, Estonia
7 shared publications - Craig Donlon
European Space Agency ESA/ESTEC, Keplerlaan 1, 2201 AZ Noordwijk, The Netherlands
6 shared publications - Ilmar Ansko
Tartu Observatory, University of Tartu, 61602 Tõravere, Estonia
6 shared publications - Joel Kuusk
Tartu Observatory, University of Tartu, 61602 Tõravere, Estonia
6 shared publications - Gavin H. Tilstone
Plymouth Marine Laboratory, Plymouth, UK
5 shared publications
Latest Publications
- Open Access
- 4 March 2021
- Published by Copernicus GmbH
Back arc basin unveiled at South Pole along an irregular East Antarctic craton margin
An Andean-style convergent margin was active between ca 580 and 460 Ma along the margin of Gondwana. It led to the emplacement of a major magmatic arc, which is in parts exposed along the much younger Transantarctic Mountains (TAM). Arc magmatism, thrusting, deformation and metamorphism are hallmarks of the long-lived subduction-related Ross Orogen (RO).Despite the wealth of knowledge on the RO, the location, structure and evolution of the unexposed boundary between the Precambrian Mawson Craton and the RO remains very poorly known, particularly in the South Pole (SP) region- one of the largest poles of ignorance in the whole of East Antarctica. Here we combine new aeromagnetic data collected during the ESA PolarGAP campaign with vintage ADMAP 2.0 (Golynsky et al., 2018- GRL) aeromagnetic datasets in the SP region and level these using the satellite magnetic LCS-1 model to investigate the craton margin and RO. The final levelled data were draped at 2800 m above the bedrock topography (Morlighem et al., 2020, Nature Geo.) and reduced to the pole. To enhance magnetic signatures and reveal subglacial basement terranes we applied pseudo-gravity transforms, derivatives and upward continuation. We also computed new airborne gravity residual maps and compared these with enhanced magnetic anomaly images. We applied a variety of depth to source of the magnetic and gravity residual anomalies, including tilt depth, Werner and Euler Deconvolution and constructed simple 2D models of the crustal architecture of the RO and the adjacent Precambrian craton margin. Using the information from enhanced aeromagnetic imaging and combined magnetic and gravity modelling we propose a new tectonic model for the region. In our model, a former late Neoproterozoic rifted margin that developed along an irregular cratonic margin of the Mawson continent evolved during the Ross Orogen in a wide back-arc basin tectonic setting, linked to a predominantly retreating accretionary subduction-related setting from ca 530 Ma to 500 Ma. This led to the emplacement of magnetite-rich ribbons of arc crust, which are magnetically imaged for the first time in this sector of the active margin. Complex deformation of these ribbons is also imaged from aeromagnetic signatures and appears to resemble some of the deformation patterns observed in the Tasmanides in Australia in evolving retreating accretionary arc and back arc systems (e.g Moresi et al., 2014, Nature).
- 4 March 2021
- Published by Copernicus GmbH
Open AccessBack arc basin unveiled at South Pole along an irregular East Antarctic craton margin
An Andean-style convergent margin was active between ca 580 and 460 Ma along the margin of Gondwana. It led to the emplacement of a major magmatic arc, which is in parts exposed along the much younger Transantarctic Mountains (TAM). Arc magmatism, thrusting, deformation and metamorphism are hallmarks of the long-lived subduction-related Ross Orogen (RO).Despite the wealth of knowledge on the RO, the location, structure and evolution of the unexposed boundary between the Precambrian Mawson Craton and the RO remains very poorly known, particularly in the South Pole (SP) region- one of the largest poles of ignorance in the whole of East Antarctica. Here we combine new aeromagnetic data collected during the ESA PolarGAP campaign with vintage ADMAP 2.0 (Golynsky et al., 2018- GRL) aeromagnetic datasets in the SP region and level these using the satellite magnetic LCS-1 model to investigate the craton margin and RO. The final levelled data were draped at 2800 m above the bedrock topography (Morlighem et al., 2020, Nature Geo.) and reduced to the pole. To enhance magnetic signatures and reveal subglacial basement terranes we applied pseudo-gravity transforms, derivatives and upward continuation. We also computed new airborne gravity residual maps and compared these with enhanced magnetic anomaly images. We applied a variety of depth to source of the magnetic and gravity residual anomalies, including tilt depth, Werner and Euler Deconvolution and constructed simple 2D models of the crustal architecture of the RO and the adjacent Precambrian craton margin. Using the information from enhanced aeromagnetic imaging and combined magnetic and gravity modelling we propose a new tectonic model for the region. In our model, a former late Neoproterozoic rifted margin that developed along an irregular cratonic margin of the Mawson continent evolved during the Ross Orogen in a wide back-arc basin tectonic setting, linked to a predominantly retreating accretionary subduction-related setting from ca 530 Ma to 500 Ma. This led to the emplacement of magnetite-rich ribbons of arc crust, which are magnetically imaged for the first time in this sector of the active margin. Complex deformation of these ribbons is also imaged from aeromagnetic signatures and appears to resemble some of the deformation patterns observed in the Tasmanides in Australia in evolving retreating accretionary arc and back arc systems (e.g Moresi et al., 2014, Nature).
- Open Access
- 10 July 2020
- Published by MDPI AG in Remote Sensing
- Vol. 12 (14) , 2220
Results from Verification of Reference Irradiance and Radiance Sources Laboratory Calibration Experiment Campaign
We present the results from Verification of Reference Irradiance and Radiance Sources Laboratory Calibration Experiment Campaign. Ten international laboratories took part in the measurements. The spectral irradiance comparison included the measurements of the 1000 W tungsten halogen filament lamps in the spectral range of 350 nm–900 nm in the pilot laboratory. The radiance comparison took a form of round robin where each participant in turn received two transfer radiometers and did the radiance calibration in their own laboratory. The transfer radiometers have seven spectral bands covering the wavelength range from 400 nm–700 nm. The irradiance comparison results showed an agreement between all lamps within ±1.5%. The radiance comparison results presented higher than expected discrepancies at the level of ±4%. Additional investigation to determine the causes for these discrepancies identified them as a combination of the size-of-source effect and instrument effective field of view that affected some of the results.
- 10 July 2020
- Published by MDPI AG in Remote Sensing
- Vol. 12 (14) , 2220
Open AccessResults from Verification of Reference Irradiance and Radiance Sources Laboratory Calibration Experiment Campaign
We present the results from Verification of Reference Irradiance and Radiance Sources Laboratory Calibration Experiment Campaign. Ten international laboratories took part in the measurements. The spectral irradiance comparison included the measurements of the 1000 W tungsten halogen filament lamps in the spectral range of 350 nm–900 nm in the pilot laboratory. The radiance comparison took a form of round robin where each participant in turn received two transfer radiometers and did the radiance calibration in their own laboratory. The transfer radiometers have seven spectral bands covering the wavelength range from 400 nm–700 nm. The irradiance comparison results showed an agreement between all lamps within ±1.5%. The radiance comparison results presented higher than expected discrepancies at the level of ±4%. Additional investigation to determine the causes for these discrepancies identified them as a combination of the size-of-source effect and instrument effective field of view that affected some of the results.
- Open Access
- 22 May 2020
- Published by MDPI AG in Remote Sensing
- Vol. 12 (10) , 1669
Comparison of Above-Water Seabird and TriOS Radiometers along an Atlantic Meridional Transect
The Fiducial Reference Measurements for Satellite Ocean Color (FRM4SOC) project has carried out a range of activities to evaluate and improve the state-of-the-art in ocean color radiometry. This paper described the results from a ship-based intercomparison conducted on the Atlantic Meridional Transect 27 from 23rd September to 5th November 2017. Two different radiometric systems, TriOS-Radiation Measurement Sensor with Enhanced Spectral resolution (RAMSES) and Seabird-Hyperspectral Surface Acquisition System (HyperSAS), were compared and operated side-by-side over a wide range of Atlantic provinces and environmental conditions. Both systems were calibrated for traceability to SI (Système international) units at the same optical laboratory under uniform conditions before and after the field campaign. The in situ results and their accompanying uncertainties were evaluated using the same data handling protocols. The field data revealed variability in the responsivity between TRiOS and Seabird sensors, which is dependent on the ambient environmental and illumination conditions. The straylight effects for individual sensors were mostly within ±3%. A near infra-red (NIR) similarity correction changed the water-leaving reflectance (ρw) and water-leaving radiance (Lw) spectra significantly, bringing also a convergence in outliers. For improving the estimates of in situ uncertainty, it is recommended that additional characterization of radiometers and environmental ancillary measurements are undertaken. In general, the comparison of radiometric systems showed agreement within the evaluated uncertainty limits. Consistency of in situ results with the available Sentinel-3A Ocean and Land Color Instrument (OLCI) data in the range from (400…560) nm was also satisfactory (−8% < Mean Percentage Difference (MPD) < 15%) and showed good agreement in terms of the shape of the spectra and absolute values.
- 22 May 2020
- Published by MDPI AG in Remote Sensing
- Vol. 12 (10) , 1669
Open AccessComparison of Above-Water Seabird and TriOS Radiometers along an Atlantic Meridional Transect
The Fiducial Reference Measurements for Satellite Ocean Color (FRM4SOC) project has carried out a range of activities to evaluate and improve the state-of-the-art in ocean color radiometry. This paper described the results from a ship-based intercomparison conducted on the Atlantic Meridional Transect 27 from 23rd September to 5th November 2017. Two different radiometric systems, TriOS-Radiation Measurement Sensor with Enhanced Spectral resolution (RAMSES) and Seabird-Hyperspectral Surface Acquisition System (HyperSAS), were compared and operated side-by-side over a wide range of Atlantic provinces and environmental conditions. Both systems were calibrated for traceability to SI (Système international) units at the same optical laboratory under uniform conditions before and after the field campaign. The in situ results and their accompanying uncertainties were evaluated using the same data handling protocols. The field data revealed variability in the responsivity between TRiOS and Seabird sensors, which is dependent on the ambient environmental and illumination conditions. The straylight effects for individual sensors were mostly within ±3%. A near infra-red (NIR) similarity correction changed the water-leaving reflectance (ρw) and water-leaving radiance (Lw) spectra significantly, bringing also a convergence in outliers. For improving the estimates of in situ uncertainty, it is recommended that additional characterization of radiometers and environmental ancillary measurements are undertaken. In general, the comparison of radiometric systems showed agreement within the evaluated uncertainty limits. Consistency of in situ results with the available Sentinel-3A Ocean and Land Color Instrument (OLCI) data in the range from (400…560) nm was also satisfactory (−8% < Mean Percentage Difference (MPD) < 15%) and showed good agreement in terms of the shape of the spectra and absolute values.
- Open Access
- 16 May 2020
- Published by MDPI AG in Remote Sensing
- Vol. 12 (10) , 1587
Field Intercomparison of Radiometer Measurements for Ocean Colour Validation
A field intercomparison was conducted at the Acqua Alta Oceanographic Tower (AAOT) in the northern Adriatic Sea, from 9 to 19 July 2018 to assess differences in the accuracy of in- and above-water radiometer measurements used for the validation of ocean colour products. Ten measurement systems were compared. Prior to the intercomparison, the absolute radiometric calibration of all sensors was carried out using the same standards and methods at the same reference laboratory. Measurements were performed under clear sky conditions, relatively low sun zenith angles, moderately low sea state and on the same deployment platform and frame (except in-water systems). The weighted average of five above-water measurements was used as baseline reference for comparisons. For downwelling irradiance ( ), there was generally good agreement between sensors with differences of <6% for most of the sensors over the spectral range 400 nm–665 nm. One sensor exhibited a systematic bias, of up to 11%, due to poor cosine response. For sky radiance ( ) the spectrally averaged difference between optical systems was <2.5% with a root mean square error (RMS) <0.01 mWm−2 nm−1 sr−1. For total above-water upwelling radiance ( ), the difference was <3.5% with an RMS <0.009 mWm−2 nm−1 sr−1. For remote-sensing reflectance ( ), the differences between above-water TriOS RAMSES were <3.5% and <2.5% at 443 and 560 nm, respectively, and were <7.5% for some systems at 665 nm. Seabird-Hyperspectral Surface Acquisition System (HyperSAS) sensors were on average within 3.5% at 443 nm, 1% at 560 nm, and 3% at 665 nm. The differences between the weighted mean of the above-water and in-water systems was <15.8% across visible bands. A sensitivity analysis showed that accounted for the largest fraction of the variance in , which suggests that minimizing the errors arising from this measurement is the most important variable in reducing the inter-group differences in . The differences may also be due, in part, to using five of the above-water systems as a reference. To avoid this, in situ normalized water-leaving radiance ( ) was therefore compared to AERONET-OC SeaPRiSM as an alternative reference measurement. For the TriOS-RAMSES and Seabird-HyperSAS sensors the differences were similar across the visible spectra with 4.7% and 4.9%, respectively. The difference between SeaPRiSM and two in-water systems at blue, green and red bands was 11.8%. This was partly due to temporal and spatial differences in sampling between the in-water and above-water systems and possibly due to uncertainties in instrument self-shading for one of the in-water measurements.- 16 May 2020
- Published by MDPI AG in Remote Sensing
- Vol. 12 (10) , 1587
Open AccessField Intercomparison of Radiometer Measurements for Ocean Colour Validation
A field intercomparison was conducted at the Acqua Alta Oceanographic Tower (AAOT) in the northern Adriatic Sea, from 9 to 19 July 2018 to assess differences in the accuracy of in- and above-water radiometer measurements used for the validation of ocean colour products. Ten measurement systems were compared. Prior to the intercomparison, the absolute radiometric calibration of all sensors was carried out using the same standards and methods at the same reference laboratory. Measurements were performed under clear sky conditions, relatively low sun zenith angles, moderately low sea state and on the same deployment platform and frame (except in-water systems). The weighted average of five above-water measurements was used as baseline reference for comparisons. For downwelling irradiance ( ), there was generally good agreement between sensors with differences of <6% for most of the sensors over the spectral range 400 nm–665 nm. One sensor exhibited a systematic bias, of up to 11%, due to poor cosine response. For sky radiance ( ) the spectrally averaged difference between optical systems was <2.5% with a root mean square error (RMS) <0.01 mWm−2 nm−1 sr−1. For total above-water upwelling radiance ( ), the difference was <3.5% with an RMS <0.009 mWm−2 nm−1 sr−1. For remote-sensing reflectance ( ), the differences between above-water TriOS RAMSES were <3.5% and <2.5% at 443 and 560 nm, respectively, and were <7.5% for some systems at 665 nm. Seabird-Hyperspectral Surface Acquisition System (HyperSAS) sensors were on average within 3.5% at 443 nm, 1% at 560 nm, and 3% at 665 nm. The differences between the weighted mean of the above-water and in-water systems was <15.8% across visible bands. A sensitivity analysis showed that accounted for the largest fraction of the variance in , which suggests that minimizing the errors arising from this measurement is the most important variable in reducing the inter-group differences in . The differences may also be due, in part, to using five of the above-water systems as a reference. To avoid this, in situ normalized water-leaving radiance ( ) was therefore compared to AERONET-OC SeaPRiSM as an alternative reference measurement. For the TriOS-RAMSES and Seabird-HyperSAS sensors the differences were similar across the visible spectra with 4.7% and 4.9%, respectively. The difference between SeaPRiSM and two in-water systems at blue, green and red bands was 11.8%. This was partly due to temporal and spatial differences in sampling between the in-water and above-water systems and possibly due to uncertainties in instrument self-shading for one of the in-water measurements. - Open Access
- 22 April 2020
- Published by MDPI AG in Remote Sensing
- Vol. 12 (8) , 1322
Fiducial Reference Measurements for Satellite Ocean Colour (FRM4SOC)
Earth observation data can help us understand and address some of the grand challenges and threats facing us today as a species and as a planet, for example climate change and its impacts and sustainable use of the Earth’s resources. However, in order to have confidence in earth observation data, measurements made at the surface of the Earth, with the intention of providing verification or validation of satellite-mounted sensor measurements, should be trustworthy and at least of the same high quality as those taken with the satellite sensors themselves. Metrology tells us that in order to be trustworthy, measurements should include an unbroken chain of SI-traceable calibrations and comparisons and full uncertainty budgets for each of the in situ sensors. Until now, this has not been the case for most satellite validation measurements. Therefore, within this context, the European Space Agency (ESA) funded a series of Fiducial Reference Measurements (FRM) projects targeting the validation of satellite data products of the atmosphere, land, and ocean, and setting the framework, standards, and protocols for future satellite validation efforts. The FRM4SOC project was structured to provide this support for evaluating and improving the state of the art in ocean colour radiometry (OCR) and satellite ocean colour validation through a series of comparisons under the auspices of the Committee on Earth Observation Satellites (CEOS). This followed the recommendations from the International Ocean Colour Coordinating Group’s white paper and supports the CEOS ocean colour virtual constellation. The main objective was to establish and maintain SI traceable ground-based FRM for satellite ocean colour and thus make a fundamental contribution to the European system for monitoring the Earth (Copernicus). This paper outlines the FRM4SOC project structure, objectives and methodology and highlights the main results and achievements of the project: (1) An international SI-traceable comparison of irradiance and radiance sources used for OCR calibration that set measurement, calibration and uncertainty estimation protocols and indicated good agreement between the participating calibration laboratories from around the world; (2) An international SI-traceable laboratory and outdoor comparison of radiometers used for satellite ocean colour validation that set OCR calibration and comparison protocols; (3) A major review and update to the protocols for taking irradiance and radiance field measurements for satellite ocean colour validation, with particular focus on aspects of data acquisition and processing that must be considered in the estimation of measurement uncertainty and guidelines for good practice; (4) A technical comparison of the main radiometers used globally for satellite ocean colour validation bringing radiometer manufacturers together around the same table for the first time to discuss instrument characterisation and its documentation, as needed for measurement uncertainty estimation; (5) Two major international side-by-side field intercomparisons of multiple ocean colour radiometers, one on the Atlantic Meridional Transect (AMT) oceanographic cruise, and the other on the Acqua Alta oceanographic tower in the Gulf of Venice; (6) Impact and promotion of FRM within the ocean colour community, including a scientific road map for the FRM-based future of satellite ocean colour validation and vicarious calibration (based on the findings of the FRM4SOC project, the consensus from two major international FRM4SOC workshops and previous literature, including the IOCCG white paper on in situ ocean colour radiometry).
- 22 April 2020
- Published by MDPI AG in Remote Sensing
- Vol. 12 (8) , 1322
Open AccessFiducial Reference Measurements for Satellite Ocean Colour (FRM4SOC)
Earth observation data can help us understand and address some of the grand challenges and threats facing us today as a species and as a planet, for example climate change and its impacts and sustainable use of the Earth’s resources. However, in order to have confidence in earth observation data, measurements made at the surface of the Earth, with the intention of providing verification or validation of satellite-mounted sensor measurements, should be trustworthy and at least of the same high quality as those taken with the satellite sensors themselves. Metrology tells us that in order to be trustworthy, measurements should include an unbroken chain of SI-traceable calibrations and comparisons and full uncertainty budgets for each of the in situ sensors. Until now, this has not been the case for most satellite validation measurements. Therefore, within this context, the European Space Agency (ESA) funded a series of Fiducial Reference Measurements (FRM) projects targeting the validation of satellite data products of the atmosphere, land, and ocean, and setting the framework, standards, and protocols for future satellite validation efforts. The FRM4SOC project was structured to provide this support for evaluating and improving the state of the art in ocean colour radiometry (OCR) and satellite ocean colour validation through a series of comparisons under the auspices of the Committee on Earth Observation Satellites (CEOS). This followed the recommendations from the International Ocean Colour Coordinating Group’s white paper and supports the CEOS ocean colour virtual constellation. The main objective was to establish and maintain SI traceable ground-based FRM for satellite ocean colour and thus make a fundamental contribution to the European system for monitoring the Earth (Copernicus). This paper outlines the FRM4SOC project structure, objectives and methodology and highlights the main results and achievements of the project: (1) An international SI-traceable comparison of irradiance and radiance sources used for OCR calibration that set measurement, calibration and uncertainty estimation protocols and indicated good agreement between the participating calibration laboratories from around the world; (2) An international SI-traceable laboratory and outdoor comparison of radiometers used for satellite ocean colour validation that set OCR calibration and comparison protocols; (3) A major review and update to the protocols for taking irradiance and radiance field measurements for satellite ocean colour validation, with particular focus on aspects of data acquisition and processing that must be considered in the estimation of measurement uncertainty and guidelines for good practice; (4) A technical comparison of the main radiometers used globally for satellite ocean colour validation bringing radiometer manufacturers together around the same table for the first time to discuss instrument characterisation and its documentation, as needed for measurement uncertainty estimation; (5) Two major international side-by-side field intercomparisons of multiple ocean colour radiometers, one on the Atlantic Meridional Transect (AMT) oceanographic cruise, and the other on the Acqua Alta oceanographic tower in the Gulf of Venice; (6) Impact and promotion of FRM within the ocean colour community, including a scientific road map for the FRM-based future of satellite ocean colour validation and vicarious calibration (based on the findings of the FRM4SOC project, the consensus from two major international FRM4SOC workshops and previous literature, including the IOCCG white paper on in situ ocean colour radiometry).
- Open Access
- 29 February 2020
- Published by MDPI AG in Remote Sensing
- Vol. 12 (5) , 780
Example of Monte Carlo Method Uncertainty Evaluation for Above-Water Ocean Colour Radiometry
We describe a method to evaluate an uncertainly budget for the in situ Ocean Colour Radiometric measurements. A Monte Carlo approach is chosen to propagate the measurement uncertainty inputs through the measurements model. The measurement model is designed to address instrument characteristics and uncertainty associated with them. We present the results for a particular example when the radiometers were fully characterised and then use the same data to show a case when such characterisation is missing. This, depending on the measurement and the wavelength, can increase the uncertainty value significantly; for example, the downwelling irradiance at 442.5 nm with fully characterised instruments can reach uncertainty values of 1%, but for the instruments without such characterisation, that value could increase to almost 7%. The uncertainty values presented in this paper are not final, as some of the environmental contributors were not fully evaluated. The main conclusion of this work are the significance of thoughtful instrument characterisation and correction for the most significant uncertainty contributions in order to achieve a lower measurements uncertainty value.
- 29 February 2020
- Published by MDPI AG in Remote Sensing
- Vol. 12 (5) , 780
Open AccessExample of Monte Carlo Method Uncertainty Evaluation for Above-Water Ocean Colour Radiometry
We describe a method to evaluate an uncertainly budget for the in situ Ocean Colour Radiometric measurements. A Monte Carlo approach is chosen to propagate the measurement uncertainty inputs through the measurements model. The measurement model is designed to address instrument characteristics and uncertainty associated with them. We present the results for a particular example when the radiometers were fully characterised and then use the same data to show a case when such characterisation is missing. This, depending on the measurement and the wavelength, can increase the uncertainty value significantly; for example, the downwelling irradiance at 442.5 nm with fully characterised instruments can reach uncertainty values of 1%, but for the instruments without such characterisation, that value could increase to almost 7%. The uncertainty values presented in this paper are not final, as some of the environmental contributors were not fully evaluated. The main conclusion of this work are the significance of thoughtful instrument characterisation and correction for the most significant uncertainty contributions in order to achieve a lower measurements uncertainty value.
- Open Access
- 11 May 2019
- Published by MDPI AG in Remote Sensing
- Vol. 11 (9) , 1129
Field Intercomparison of Radiometers Used for Satellite Validation in the 400–900 nm Range
An intercomparison of radiance and irradiance ocean color radiometers (the second laboratory comparison exercise—LCE-2) was organized within the frame of the European Space Agency funded project Fiducial Reference Measurements for Satellite Ocean Color (FRM4SOC) May 8–13, 2017 at Tartu Observatory, Estonia. LCE-2 consisted of three sub-tasks: (1) SI-traceable radiometric calibration of all the participating radiance and irradiance radiometers at the Tartu Observatory just before the comparisons; (2) indoor, laboratory intercomparison using stable radiance and irradiance sources in a controlled environment; (3) outdoor, field intercomparison of natural radiation sources over a natural water surface. The aim of the experiment was to provide a link in the chain of traceability from field measurements of water reflectance to the uniform SI-traceable calibration, and after calibration to verify whether different instruments measuring the same object provide results consistent within the expected uncertainty limits. This paper describes the third phase of LCE-2: The results of the field experiment. The calibration of radiometers and laboratory comparison experiment are presented in a related paper of the same journal issue. Compared to the laboratory comparison, the field intercomparison has demonstrated substantially larger variability between freshly calibrated sensors, because the targets and environmental conditions during radiometric calibration were different, both spectrally and spatially. Major differences were found for radiance sensors measuring a sunlit water target at viewing zenith angle of 139° because of the different fields of view. Major differences were found for irradiance sensors because of imperfect cosine response of diffusers. Variability between individual radiometers did depend significantly also on the type of the sensor and on the specific measurement target. Uniform SI traceable radiometric calibration ensuring fairly good consistency for indoor, laboratory measurements is insufficient for outdoor, field measurements, mainly due to the different angular variability of illumination. More stringent specifications and individual testing of radiometers for all relevant systematic effects (temperature, nonlinearity, spectral stray light, etc.) are needed to reduce biases between instruments and better quantify measurement uncertainties.
- 11 May 2019
- Published by MDPI AG in Remote Sensing
- Vol. 11 (9) , 1129
Open AccessField Intercomparison of Radiometers Used for Satellite Validation in the 400–900 nm Range
An intercomparison of radiance and irradiance ocean color radiometers (the second laboratory comparison exercise—LCE-2) was organized within the frame of the European Space Agency funded project Fiducial Reference Measurements for Satellite Ocean Color (FRM4SOC) May 8–13, 2017 at Tartu Observatory, Estonia. LCE-2 consisted of three sub-tasks: (1) SI-traceable radiometric calibration of all the participating radiance and irradiance radiometers at the Tartu Observatory just before the comparisons; (2) indoor, laboratory intercomparison using stable radiance and irradiance sources in a controlled environment; (3) outdoor, field intercomparison of natural radiation sources over a natural water surface. The aim of the experiment was to provide a link in the chain of traceability from field measurements of water reflectance to the uniform SI-traceable calibration, and after calibration to verify whether different instruments measuring the same object provide results consistent within the expected uncertainty limits. This paper describes the third phase of LCE-2: The results of the field experiment. The calibration of radiometers and laboratory comparison experiment are presented in a related paper of the same journal issue. Compared to the laboratory comparison, the field intercomparison has demonstrated substantially larger variability between freshly calibrated sensors, because the targets and environmental conditions during radiometric calibration were different, both spectrally and spatially. Major differences were found for radiance sensors measuring a sunlit water target at viewing zenith angle of 139° because of the different fields of view. Major differences were found for irradiance sensors because of imperfect cosine response of diffusers. Variability between individual radiometers did depend significantly also on the type of the sensor and on the specific measurement target. Uniform SI traceable radiometric calibration ensuring fairly good consistency for indoor, laboratory measurements is insufficient for outdoor, field measurements, mainly due to the different angular variability of illumination. More stringent specifications and individual testing of radiometers for all relevant systematic effects (temperature, nonlinearity, spectral stray light, etc.) are needed to reduce biases between instruments and better quantify measurement uncertainties.
- Open Access
- 8 May 2019
- Published by MDPI AG in Remote Sensing
- Vol. 11 (9) , 1101
Laboratory Intercomparison of Radiometers Used for Satellite Validation in the 400–900 nm Range
An intercomparison of radiance and irradiance ocean color radiometers (The Second Laboratory Comparison Exercise—LCE-2) was organized within the frame of the European Space Agency funded project Fiducial Reference Measurements for Satellite Ocean Color (FRM4SOC) May 8–13, 2017 at Tartu Observatory, Estonia. LCE-2 consisted of three sub-tasks: 1) SI-traceable radiometric calibration of all the participating radiance and irradiance radiometers at the Tartu Observatory just before the comparisons; 2) Indoor intercomparison using stable radiance and irradiance sources in controlled environment; and 3) Outdoor intercomparison of natural radiation sources over terrestrial water surface. The aim of the experiment was to provide one link in the chain of traceability from field measurements of water reflectance to the uniform SI-traceable calibration, and after calibration to verify whether different instruments measuring the same object provide results consistent within the expected uncertainty limits. This paper describes the activities and results of the first two phases of LCE-2: the SI-traceable radiometric calibration and indoor intercomparison, the results of outdoor experiment are presented in a related paper of the same journal issue. The indoor experiment of the LCE-2 has proven that uniform calibration just before the use of radiometers is highly effective. Distinct radiometers from different manufacturers operated by different scientists can yield quite close radiance and irradiance results (standard deviation s < 1%) under defined conditions. This holds when measuring stable lamp-based targets under stationary laboratory conditions with all the radiometers uniformly calibrated against the same standards just prior to the experiment. In addition, some unification of measurement and data processing must be settled. Uncertainty of radiance and irradiance measurement under these conditions largely consists of the sensor’s calibration uncertainty and of the spread of results obtained by individual sensors measuring the same object.
- 8 May 2019
- Published by MDPI AG in Remote Sensing
- Vol. 11 (9) , 1101
Open AccessLaboratory Intercomparison of Radiometers Used for Satellite Validation in the 400–900 nm Range
An intercomparison of radiance and irradiance ocean color radiometers (The Second Laboratory Comparison Exercise—LCE-2) was organized within the frame of the European Space Agency funded project Fiducial Reference Measurements for Satellite Ocean Color (FRM4SOC) May 8–13, 2017 at Tartu Observatory, Estonia. LCE-2 consisted of three sub-tasks: 1) SI-traceable radiometric calibration of all the participating radiance and irradiance radiometers at the Tartu Observatory just before the comparisons; 2) Indoor intercomparison using stable radiance and irradiance sources in controlled environment; and 3) Outdoor intercomparison of natural radiation sources over terrestrial water surface. The aim of the experiment was to provide one link in the chain of traceability from field measurements of water reflectance to the uniform SI-traceable calibration, and after calibration to verify whether different instruments measuring the same object provide results consistent within the expected uncertainty limits. This paper describes the activities and results of the first two phases of LCE-2: the SI-traceable radiometric calibration and indoor intercomparison, the results of outdoor experiment are presented in a related paper of the same journal issue. The indoor experiment of the LCE-2 has proven that uniform calibration just before the use of radiometers is highly effective. Distinct radiometers from different manufacturers operated by different scientists can yield quite close radiance and irradiance results (standard deviation s < 1%) under defined conditions. This holds when measuring stable lamp-based targets under stationary laboratory conditions with all the radiometers uniformly calibrated against the same standards just prior to the experiment. In addition, some unification of measurement and data processing must be settled. Uncertainty of radiance and irradiance measurement under these conditions largely consists of the sensor’s calibration uncertainty and of the spread of results obtained by individual sensors measuring the same object.
- 2 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 12 (7) , 2470-2476
Airborne Wind Vector Scatterometer for Sea Surface Measurements
This paper describes the development of an Airborne Wind Vector Scatterometer for low-resolution wind speed measurements. The scatterometer is designed to meet a wind speed accuracy requirement of 1 m/s. In this ad hoc and low-budget project, the development of the instrument exploited some already existing subsystems. The development started from the definition of the scientific system requirements and ended with two experimental flights for wind vector retrieval from three test areas in the Gulf of Finland, the Baltic Sea. One of the flights was planned for a simultaneous overpass with the TDS-1 satellite that was conducting Global Navigations Satellite System – Reflectometry (GNSS-R) measurements. The results confirm the measurement capabilities of the GNSS-R technology and the desired 1 m/s wind speed accuracy of the scatterometer that was developed.
- 2 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 12 (7) , 2470-2476
Airborne Wind Vector Scatterometer for Sea Surface Measurements
This paper describes the development of an Airborne Wind Vector Scatterometer for low-resolution wind speed measurements. The scatterometer is designed to meet a wind speed accuracy requirement of 1 m/s. In this ad hoc and low-budget project, the development of the instrument exploited some already existing subsystems. The development started from the definition of the scientific system requirements and ended with two experimental flights for wind vector retrieval from three test areas in the Gulf of Finland, the Baltic Sea. One of the flights was planned for a simultaneous overpass with the TDS-1 satellite that was conducting Global Navigations Satellite System – Reflectometry (GNSS-R) measurements. The results confirm the measurement capabilities of the GNSS-R technology and the desired 1 m/s wind speed accuracy of the scatterometer that was developed.
- 23 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 11 (10) , 3617-3627
In Situ Reference Datasets From the TropiSAR and AfriSAR Campaigns in Support of Upcoming Spaceborne Biomass Missions
Tropical forests are a key component of the global carbon cycle. Yet, there are still high uncertainties in forest carbon stock and flux estimates, notably because of their spatial and temporal variability across the tropics. Several upcoming spaceborne missions have been designed to address this gap. High-quality ground data are essential for accurate calibration/validation so that spaceborne biomass missions can reach their full potential in reducing uncertainties regarding forest carbon stocks and fluxes. The BIOMASS mission, a P-band SAR satellite from the European Space Agency (ESA), aims at improving carbon stock mapping and reducing uncertainty in the carbon fluxes from deforestation, forest degradation, and regrowth. In situ activities in support of the BIOMASS mission were carried out in French Guiana and Gabon during the TropiSAR and AfriSAR campaigns. During these campaigns, airborne P-band SAR, forest inventory, and lidar data were collected over six study sites. This paper describes the methods used for forest inventory and lidar data collection and analysis, and presents resulting plot estimates and aboveground biomass maps. These reference datasets along with intermediate products (e.g., canopy height models) can be accessed through ESA's Forest Observation System and the Dryad data repository and will be useful for BIOMASS but also to other spaceborne biomass missions such as GEDI, NISAR, and Tandem-L for calibration/validation purposes. During data quality control and analysis, prospects for reducing uncertainties have been identified, and this paper finishes with a series of recommendations for future tropical forest field campaigns to better serve the remote sensing community.
- 23 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 11 (10) , 3617-3627
In Situ Reference Datasets From the TropiSAR and AfriSAR Campaigns in Support of Upcoming Spaceborne Biomass Missions
Tropical forests are a key component of the global carbon cycle. Yet, there are still high uncertainties in forest carbon stock and flux estimates, notably because of their spatial and temporal variability across the tropics. Several upcoming spaceborne missions have been designed to address this gap. High-quality ground data are essential for accurate calibration/validation so that spaceborne biomass missions can reach their full potential in reducing uncertainties regarding forest carbon stocks and fluxes. The BIOMASS mission, a P-band SAR satellite from the European Space Agency (ESA), aims at improving carbon stock mapping and reducing uncertainty in the carbon fluxes from deforestation, forest degradation, and regrowth. In situ activities in support of the BIOMASS mission were carried out in French Guiana and Gabon during the TropiSAR and AfriSAR campaigns. During these campaigns, airborne P-band SAR, forest inventory, and lidar data were collected over six study sites. This paper describes the methods used for forest inventory and lidar data collection and analysis, and presents resulting plot estimates and aboveground biomass maps. These reference datasets along with intermediate products (e.g., canopy height models) can be accessed through ESA's Forest Observation System and the Dryad data repository and will be useful for BIOMASS but also to other spaceborne biomass missions such as GEDI, NISAR, and Tandem-L for calibration/validation purposes. During data quality control and analysis, prospects for reducing uncertainties have been identified, and this paper finishes with a series of recommendations for future tropical forest field campaigns to better serve the remote sensing community.