Dan Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dan Zhao has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Xin Li
Xi’an Jiaotong University
3 shared publications - Chang Wang
Department of Microelectronics, School of Electronics and Information Engineering, Xi’an Jiaotong University, Xi’an 710049, China
2 shared publications - Hongzhong Liu
State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, People’s Republic of China
2 shared publications - Weihua Liu
School of Microelectronics, Xi'an Jiaotong University 1 , Xi'an 710049
2 shared publications - Deyin Zhao
SINOPEC Northwest Company of China Petroleum and Chemical Corporation, Urumqi 830011, China
1 shared publication - Gong Li
School of Microelectronics, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication
Latest Publications
- Open Access
Ion Sensitive GO-Si Based Metal-Semiconductor Junction Resistor Gas Sensor
Gas sensor based on the Ultraviolet and Ozone (UVO) treated Chemical Vapor Deposition (CVD) Graphene Oxide (GO) and the Ion Sensitive GO-Si based metal-semiconductor junction resistor was designed and realized. Under different gate voltages, the response characteristics of the sensor to ammonia concentration, as well as the selectivity and stability of the sensor were studied. The test results show that the comprehensive performance of the gas sensor is the best when the UVO processing time is 1 min and the applied gate voltage is −9 V. The proposed Ion Sensitive GO-Si based metal-semiconductor junction resistor Gas Sensor can detect 250 ppb ammonia with a sensitivity of 4%. The detection limit of the sensor is 50 ppb. Using acetone and ethanol as contrast gases, the sensor shows better selectivity for ammonia. The sensitivity retention rate of the sensor after 10 days is higher than 70%, which indicates that the sensor has a good retention performance.
Open AccessIon Sensitive GO-Si Based Metal-Semiconductor Junction Resistor Gas Sensor
Gas sensor based on the Ultraviolet and Ozone (UVO) treated Chemical Vapor Deposition (CVD) Graphene Oxide (GO) and the Ion Sensitive GO-Si based metal-semiconductor junction resistor was designed and realized. Under different gate voltages, the response characteristics of the sensor to ammonia concentration, as well as the selectivity and stability of the sensor were studied. The test results show that the comprehensive performance of the gas sensor is the best when the UVO processing time is 1 min and the applied gate voltage is −9 V. The proposed Ion Sensitive GO-Si based metal-semiconductor junction resistor Gas Sensor can detect 250 ppb ammonia with a sensitivity of 4%. The detection limit of the sensor is 50 ppb. Using acetone and ethanol as contrast gases, the sensor shows better selectivity for ammonia. The sensitivity retention rate of the sensor after 10 days is higher than 70%, which indicates that the sensor has a good retention performance.
- Open Access
Mixed Natural Gas Online Recognition Device Based on a Neural Network Algorithm Implemented by an FPGA
It is a daunting challenge to measure the concentration of each component in natural gas, because different components in mixed gas have cross-sensitivity for a single sensor. We have developed a mixed gas identification device based on a neural network algorithm, which can be used for the online detection of natural gas. The neural network technology is used to eliminate the cross-sensitivity of mixed gases to each sensor, in order to accurately recognize the concentrations of methane, ethane and propane, respectively. The neural network algorithm is implemented by a Field-Programmable Gate Array (FPGA) in the device, which has the advantages of small size and fast response. FPGAs take advantage of parallel computing and greatly speed up the computational process of neural networks. Within the range of 0–100% of methane, the test error for methane and heavy alkanes such as ethane and propane is less than 0.5%, and the response speed is several seconds.
Open AccessMixed Natural Gas Online Recognition Device Based on a Neural Network Algorithm Implemented by an FPGA
It is a daunting challenge to measure the concentration of each component in natural gas, because different components in mixed gas have cross-sensitivity for a single sensor. We have developed a mixed gas identification device based on a neural network algorithm, which can be used for the online detection of natural gas. The neural network technology is used to eliminate the cross-sensitivity of mixed gases to each sensor, in order to accurately recognize the concentrations of methane, ethane and propane, respectively. The neural network algorithm is implemented by a Field-Programmable Gate Array (FPGA) in the device, which has the advantages of small size and fast response. FPGAs take advantage of parallel computing and greatly speed up the computational process of neural networks. Within the range of 0–100% of methane, the test error for methane and heavy alkanes such as ethane and propane is less than 0.5%, and the response speed is several seconds.
- Open Access
Simple Synthesis of Cobalt Carbonate Hydroxide Hydrate and Reduced Graphene Oxide Hybrid Structure for High-Performance Room Temperature NH3 Sensor
A novel hybrid structure sensor based on cobalt carbonate hydroxide hydrate (CCHH) and reduced graphene oxide (RGO) was designed for room temperature NH3 detection. This hybrid structure consisted of CCHH and RGO (synthesized by a one-step hydrothermal method), in which RGO uniformly dispersed in CCHH, being used as the gas sensing film. The resistivity of the hybrid structure was highly sensitive to the changes on NH3 concentration. CCHH in the hybrid structure was the sensing material and RGO was the conductive channel material. The hybrid structure could improve signal-to-noise ratio (SNR) and the sensitivity by obtaining the optimal mass proportion of RGO, since the proportion of RGO was directly related to sensitivity. The gas sensor with 0.4 wt% RGO showed the highest gas sensing response reach to 9% to 1 ppm NH3. Compared to a conventional gas sensor, the proposed sensor not only showed high gas sensing response at room temperature but also was easy to achieve large-scale production due to the good stability and simple synthesis process.
Open AccessSimple Synthesis of Cobalt Carbonate Hydroxide Hydrate and Reduced Graphene Oxide Hybrid Structure for High-Performance Room Temperature NH3 Sensor
A novel hybrid structure sensor based on cobalt carbonate hydroxide hydrate (CCHH) and reduced graphene oxide (RGO) was designed for room temperature NH3 detection. This hybrid structure consisted of CCHH and RGO (synthesized by a one-step hydrothermal method), in which RGO uniformly dispersed in CCHH, being used as the gas sensing film. The resistivity of the hybrid structure was highly sensitive to the changes on NH3 concentration. CCHH in the hybrid structure was the sensing material and RGO was the conductive channel material. The hybrid structure could improve signal-to-noise ratio (SNR) and the sensitivity by obtaining the optimal mass proportion of RGO, since the proportion of RGO was directly related to sensitivity. The gas sensor with 0.4 wt% RGO showed the highest gas sensing response reach to 9% to 1 ppm NH3. Compared to a conventional gas sensor, the proposed sensor not only showed high gas sensing response at room temperature but also was easy to achieve large-scale production due to the good stability and simple synthesis process.