Ali Haydaroglu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ali Haydaroglu has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Aaron Au
Institute of Biomedical Engineering, University of Toronto, Toronto, Canada
2 shared publications - Christopher M. Yip
Institute of Biomedical Engineering, University of Toronto, Toronto, Canada
2 shared publications - Hui Guo
Department of Cell and Virus Structure, Max Planck Institute of Biochemistry, Martinsried 82512, Germany
2 shared publications - John Rubinstein
The Hospital for Sick Children
2 shared publications - Justin M. Di Trani
Molecular Medicine Program, The Hospital for Sick Children
2 shared publications - Kenneth David Maclean Harris
UCL Queen Square Institute of Neurology, University College London, London, UK
2 shared publications
Latest Publications
- Open Access
High-dimensional neuronal activity from low-dimensional latent dynamics: a solvable model
Computation in recurrent networks of neurons has been hypothesized to occur at the level of low-dimensional latent dynamics, both in artificial systems and in the brain. This hypothesis seems at odds with evidence from large-scale neuronal recordings in mice showing that neuronal population activity is high-dimensional. To demonstrate that low-dimensional latent dynamics and high-dimensional activity can be two sides of the same coin, we present an analytically solvable recurrent neural network (RNN) model whose dynamics can be exactly reduced to a low-dimensional dynamical system, but generates an activity manifold that has a high linear embedding dimension. This raises the question: Do low-dimensional latents explain the high-dimensional activity observed in mouse visual cortex? Spectral theory tells us that the covariance eigenspectrum alone does not allow us to recover the dimensionality of the latents, which can be low or high, when neurons are nonlinear. To address this indeterminacy, we develop Neural Cross-Encoder (NCE), an interpretable, nonlinear latent variable modeling method for neuronal recordings, and find that high-dimensional neuronal responses to drifting gratings and spontaneous activity in visual cortex can be reduced to low-dimensional latents, while the responses to natural images cannot. We conclude that the high-dimensional activity measured in certain conditions, such as in the absence of a stimulus, is explained by low-dimensional latents that are nonlinearly processed by individual neurons.
Open AccessHigh-dimensional neuronal activity from low-dimensional latent dynamics: a solvable model
Computation in recurrent networks of neurons has been hypothesized to occur at the level of low-dimensional latent dynamics, both in artificial systems and in the brain. This hypothesis seems at odds with evidence from large-scale neuronal recordings in mice showing that neuronal population activity is high-dimensional. To demonstrate that low-dimensional latent dynamics and high-dimensional activity can be two sides of the same coin, we present an analytically solvable recurrent neural network (RNN) model whose dynamics can be exactly reduced to a low-dimensional dynamical system, but generates an activity manifold that has a high linear embedding dimension. This raises the question: Do low-dimensional latents explain the high-dimensional activity observed in mouse visual cortex? Spectral theory tells us that the covariance eigenspectrum alone does not allow us to recover the dimensionality of the latents, which can be low or high, when neurons are nonlinear. To address this indeterminacy, we develop Neural Cross-Encoder (NCE), an interpretable, nonlinear latent variable modeling method for neuronal recordings, and find that high-dimensional neuronal responses to drifting gratings and spontaneous activity in visual cortex can be reduced to low-dimensional latents, while the responses to natural images cannot. We conclude that the high-dimensional activity measured in certain conditions, such as in the absence of a stimulus, is explained by low-dimensional latents that are nonlinearly processed by individual neurons.
- Open Access
Suite3D: Volumetric cell detection for two-photon microscopy
In two-photon imaging of neuronal activity it is common to acquire 3-dimensional volumes. However, these volumes are typically processed plane by plane, leading to duplicated cells across planes, reduced signal-to-noise ratio per cell, uncorrected axial movement, and missed cells. To overcome these limitations, we introduce Suite3D, a volumetric cell detection pipeline. Suite3D corrects for 3D brain motion, estimating axial motion and improving estimates of lateral motion. It detects neurons using 3D correlation, which improves the signal-to-background ratio and detectability of cells. Finally, it performs 3D segmentation, detecting cells across imaging planes. We validated Suite3D with data from conventional multi-plane microscopes and advanced volumetric microscopes, at various resolutions and in various brain regions. Suite3D successfully detected cells appearing on multiple imaging planes, improving cell detectability and signal quality, avoiding duplications, and running >20x faster than a prior volumetric pipeline. Suite3D offers a powerful solution for analyzing volumetric two-photon data.
Open AccessSuite3D: Volumetric cell detection for two-photon microscopy
In two-photon imaging of neuronal activity it is common to acquire 3-dimensional volumes. However, these volumes are typically processed plane by plane, leading to duplicated cells across planes, reduced signal-to-noise ratio per cell, uncorrected axial movement, and missed cells. To overcome these limitations, we introduce Suite3D, a volumetric cell detection pipeline. Suite3D corrects for 3D brain motion, estimating axial motion and improving estimates of lateral motion. It detects neurons using 3D correlation, which improves the signal-to-background ratio and detectability of cells. Finally, it performs 3D segmentation, detecting cells across imaging planes. We validated Suite3D with data from conventional multi-plane microscopes and advanced volumetric microscopes, at various resolutions and in various brain regions. Suite3D successfully detected cells appearing on multiple imaging planes, improving cell detectability and signal quality, avoiding duplications, and running >20x faster than a prior volumetric pipeline. Suite3D offers a powerful solution for analyzing volumetric two-photon data.
- Open Access
- 22 November 2019
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 75 (12) , 1063-1070
Shake-it-off: a simple ultrasonic cryo-EM specimen-preparation device
Although microscopes and image-analysis software for electron cryomicroscopy (cryo-EM) have improved dramatically in recent years, specimen-preparation methods have lagged behind. Most strategies still rely on blotting microscope grids with paper to produce a thin film of solution suitable for vitrification. This approach loses more than 99.9% of the applied sample and requires several seconds, leading to problematic air–water interface interactions for macromolecules in the resulting thin film of solution and complicating time-resolved studies. Recently developed self-wicking EM grids allow the use of small volumes of sample, with nanowires on the grid bars removing excess solution to produce a thin film within tens of milliseconds from sample application to freezing. Here, a simple cryo-EM specimen-preparation device that uses components from an ultrasonic humidifier to transfer protein solution onto a self-wicking EM grid is presented. The device is controlled by a Raspberry Pi single-board computer and all components are either widely available or can be manufactured by online services, allowing the device to be constructed in laboratories that specialize in cryo-EM rather than instrument design. The simple open-source design permits the straightforward customization of the instrument for specialized experiments.
- 22 November 2019
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 75 (12) , 1063-1070
Open AccessShake-it-off: a simple ultrasonic cryo-EM specimen-preparation device
Although microscopes and image-analysis software for electron cryomicroscopy (cryo-EM) have improved dramatically in recent years, specimen-preparation methods have lagged behind. Most strategies still rely on blotting microscope grids with paper to produce a thin film of solution suitable for vitrification. This approach loses more than 99.9% of the applied sample and requires several seconds, leading to problematic air–water interface interactions for macromolecules in the resulting thin film of solution and complicating time-resolved studies. Recently developed self-wicking EM grids allow the use of small volumes of sample, with nanowires on the grid bars removing excess solution to produce a thin film within tens of milliseconds from sample application to freezing. Here, a simple cryo-EM specimen-preparation device that uses components from an ultrasonic humidifier to transfer protein solution onto a self-wicking EM grid is presented. The device is controlled by a Raspberry Pi single-board computer and all components are either widely available or can be manufactured by online services, allowing the device to be constructed in laboratories that specialize in cryo-EM rather than instrument design. The simple open-source design permits the straightforward customization of the instrument for specialized experiments.
- Open Access
Shake-it-off : A simple ultrasonic cryo-EM specimen preparation device
Although microscopes and image analysis software for electron cryomicroscopy (cryo-EM) have improved dramatically in recent years, specimen preparation methods have lagged behind. Most strategies still rely on blotting microscope grids with paper to produce a thin film of solution suitable for vitrification. This approach loses more than 99.9% of the applied sample and requires several seconds, leading to problematic air-water interface interactions for macromolecules in the resulting thin film of solution and complicating time-resolved studies. Recently developed self-wicking EM grids allow use of small volumes of sample, with nanowires on the grid bars removing excess solution to produce a thin film within tens of milliseconds from sample application to freezing. Here we present a simple cryo-EM specimen preparation device that uses components from an ultrasonic humidifier to transfer protein solution onto a self-wicking EM grid. The device is controlled by a Raspberry Pi single board computer and all components are either widely available or can be manufactured by online services, allowing the device to be constructed in laboratories that specialize in cryo-EM, rather than instrument design. The simple open-source design permits straightforward customization of the instrument for specialized experiments. Synopsis: A method is presented for high-speed low-volume cryo-EM specimen preparation with a device constructed from readily available components.
Open AccessShake-it-off : A simple ultrasonic cryo-EM specimen preparation device
Although microscopes and image analysis software for electron cryomicroscopy (cryo-EM) have improved dramatically in recent years, specimen preparation methods have lagged behind. Most strategies still rely on blotting microscope grids with paper to produce a thin film of solution suitable for vitrification. This approach loses more than 99.9% of the applied sample and requires several seconds, leading to problematic air-water interface interactions for macromolecules in the resulting thin film of solution and complicating time-resolved studies. Recently developed self-wicking EM grids allow use of small volumes of sample, with nanowires on the grid bars removing excess solution to produce a thin film within tens of milliseconds from sample application to freezing. Here we present a simple cryo-EM specimen preparation device that uses components from an ultrasonic humidifier to transfer protein solution onto a self-wicking EM grid. The device is controlled by a Raspberry Pi single board computer and all components are either widely available or can be manufactured by online services, allowing the device to be constructed in laboratories that specialize in cryo-EM, rather than instrument design. The simple open-source design permits straightforward customization of the instrument for specialized experiments. Synopsis: A method is presented for high-speed low-volume cryo-EM specimen preparation with a device constructed from readily available components.