Marcos Frozoni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marcos Frozoni has a total of 137 co-authors. Here are the top co-authors by number of shared publications:
- Adriana de Jesus Soares
Universidade Estadual de Campinas
25 shared publications - Ana Grasiela Limoeiro
University of São Paulo
13 shared publications - Wayne Martins Nascimento
São Leopoldo Mandic University
10 shared publications - Marilia Fagury Videira Marceliano-Alves
Postgraduate Program in Dentistry, Iguaçu University, Nova Iguaçu, RJ, Brazil
8 shared publications - Marcelo Santos Coelho
Endodontic Department São Leopoldo Mandic School of Dentistry Campinas Brazil
5 shared publications - Juliana Delatorre Bronzato
Department of Restorative Dentistry, Division of Endodontics, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil
4 shared publications
Latest Publications
- Open Access
- 27 October 2026
- Published by Khabadze ZS in Эндодонтия Today
Impact of sodium hypochlorite and sterilization on R-Motion reciprocating file cyclic fatigue resistance
INTRODUCTION. Chemical exposure and sterilization may influence the fatigue behavior of nickel-titanium endodontic instruments. AIM. To evaluate the effects of immersion in 2.5% sodium hypochlorite and autoclave sterilization on dynamic cyclic fatigue resistance of R-Motion files. MATERIALS AND METHODS. Eighty R25 instruments (25/.06) were allocated to four groups ( n = 20): untreated control, autoclave sterilization, immersion in 2.5 mL of 2.5% NaOCl for 3 minutes, and immersion followed by sterilization. Dynamic fatigue was tested in a metallic canal with a 45° curvature and a radius of 6.06 mm. Time to fracture and fragment length were recorded. RESULTS. No significant differences were found for time to fracture ( p = 0.149; effect size = 0.431; power = 0.899) or fragment length ( p = 0.655; effect size = 0.118; power = 0.120). CONCLUSION. Under the tested conditions, NaOCl exposure, sterilization and their combination did not significantly change cyclic fatigue resistance relative to untreated instruments.
- 27 October 2026
- Published by Khabadze ZS in Эндодонтия Today
Open AccessImpact of sodium hypochlorite and sterilization on R-Motion reciprocating file cyclic fatigue resistance
INTRODUCTION. Chemical exposure and sterilization may influence the fatigue behavior of nickel-titanium endodontic instruments. AIM. To evaluate the effects of immersion in 2.5% sodium hypochlorite and autoclave sterilization on dynamic cyclic fatigue resistance of R-Motion files. MATERIALS AND METHODS. Eighty R25 instruments (25/.06) were allocated to four groups ( n = 20): untreated control, autoclave sterilization, immersion in 2.5 mL of 2.5% NaOCl for 3 minutes, and immersion followed by sterilization. Dynamic fatigue was tested in a metallic canal with a 45° curvature and a radius of 6.06 mm. Time to fracture and fragment length were recorded. RESULTS. No significant differences were found for time to fracture ( p = 0.149; effect size = 0.431; power = 0.899) or fragment length ( p = 0.655; effect size = 0.118; power = 0.120). CONCLUSION. Under the tested conditions, NaOCl exposure, sterilization and their combination did not significantly change cyclic fatigue resistance relative to untreated instruments.
- Open Access
- 10 September 2026
- Published by Anima Educação in Journal of Research in Dentistry
- Vol. 14 (2) , 51-58
Evaluation of the Performance of Rotary Glide Path Instruments with Different Morphometric Characteristics in Reaching the Working Length.
Aims: To evaluate the performance and the time required for Rotate Glider 15/.04 and Univy Glider 15/.04 instruments to reach the working length in mesiobuccal canals of three-dimensional (3D) printed replicas of mandibular molars. Methods: Thirty replicas were divided into two groups (n = 15): Rotate Glider 15/.04 and Univy Glider 15/.04. Glide path preparation was performed using a VDW Silver motor at 350 rpm and 1.5 N/cm² torque. Ability to reach WL and required time were recorded by video analysis. Success was defined as reaching WL within nine pecking motions. Data were analyzed using Fisher’s exact and Student’s t-tests. Scanning electron microscopy evaluated instruments’ cutting angle, helical angle, spiral number, and cross-sectional design. Results: No statistically significant differences were observed between the tested instruments regarding the number of pecking motions required to reach the WL or the instrumentation time (p > 0.05). Morphological analysis demonstrated differences in geometric characteristics between the instruments; however, these differences did not influence their overall performance. Conclusions: Both rotary glide path instruments demonstrated similar and satisfactory performance in reaching the WL and may be safely used prior to mechanized root canal preparation procedures.
- 10 September 2026
- Published by Anima Educação in Journal of Research in Dentistry
- Vol. 14 (2) , 51-58
Open AccessEvaluation of the Performance of Rotary Glide Path Instruments with Different Morphometric Characteristics in Reaching the Working Length.
Aims: To evaluate the performance and the time required for Rotate Glider 15/.04 and Univy Glider 15/.04 instruments to reach the working length in mesiobuccal canals of three-dimensional (3D) printed replicas of mandibular molars. Methods: Thirty replicas were divided into two groups (n = 15): Rotate Glider 15/.04 and Univy Glider 15/.04. Glide path preparation was performed using a VDW Silver motor at 350 rpm and 1.5 N/cm² torque. Ability to reach WL and required time were recorded by video analysis. Success was defined as reaching WL within nine pecking motions. Data were analyzed using Fisher’s exact and Student’s t-tests. Scanning electron microscopy evaluated instruments’ cutting angle, helical angle, spiral number, and cross-sectional design. Results: No statistically significant differences were observed between the tested instruments regarding the number of pecking motions required to reach the WL or the instrumentation time (p > 0.05). Morphological analysis demonstrated differences in geometric characteristics between the instruments; however, these differences did not influence their overall performance. Conclusions: Both rotary glide path instruments demonstrated similar and satisfactory performance in reaching the WL and may be safely used prior to mechanized root canal preparation procedures.
- Open Access
- 30 April 2026
- Published by Caleo in European Endodontic Journal
- Vol. 11 (4) , 150-157
Impact of Different Irrigation Needles on Debris Removal in Mesial Canals of Mandibular Molars After Conservative Preparation
The study evaluated the efficiency of 3 types of irrigation needles in removing debris during the preparation of mesial canals in mandibular molars with Vertucci Class 2 configuration and type 3 isthmus. Thirty samples were analysed using Micro–computed tomography (Micro-CT) and divided into 3 groups based on the needle type: Group OA (open-tip Navitip needle), Group CFSL (closed-tip needle with single lateral opening) and Group CFSLD (closed-tip needle with double lateral openings). Biomechanical preparation was done with Logic 30.03 files and 5.25% sodium hypochlorite, followed by final irrigation with 17% EDTA and saline solution. Micro-CT scans quantified residual debris in the main canal and isthmus. Open-tip needles were significantly more effective in cleaning the isthmus region than closed-tip needles (P=.007), although no differences among needle types were observed in the main canals (P=.717). The study concludes that needle design and insertion techniques impact debris-removal efficiency in root canal systems.
- 30 April 2026
- Published by Caleo in European Endodontic Journal
- Vol. 11 (4) , 150-157
Open AccessImpact of Different Irrigation Needles on Debris Removal in Mesial Canals of Mandibular Molars After Conservative Preparation
The study evaluated the efficiency of 3 types of irrigation needles in removing debris during the preparation of mesial canals in mandibular molars with Vertucci Class 2 configuration and type 3 isthmus. Thirty samples were analysed using Micro–computed tomography (Micro-CT) and divided into 3 groups based on the needle type: Group OA (open-tip Navitip needle), Group CFSL (closed-tip needle with single lateral opening) and Group CFSLD (closed-tip needle with double lateral openings). Biomechanical preparation was done with Logic 30.03 files and 5.25% sodium hypochlorite, followed by final irrigation with 17% EDTA and saline solution. Micro-CT scans quantified residual debris in the main canal and isthmus. Open-tip needles were significantly more effective in cleaning the isthmus region than closed-tip needles (P=.007), although no differences among needle types were observed in the main canals (P=.717). The study concludes that needle design and insertion techniques impact debris-removal efficiency in root canal systems.
- Open Access
- 1 April 2026
- Vol. 12 (2) , e70313
Evaluation of Postoperative Pain Frequency in Single-Session Endodontic Treatments With Patency and Foraminal Enlargement.
This study aimed to evaluate the incidence of postoperative pain in single-session endodontic treatments with foraminal instrumentation, considering factors such as pulpal diagnosis, tooth position, type of endodontic sealer, and sealer extrusion. Treatments were performed on 153 teeth of patients aged 12-80 years diagnosed with asymptomatic irreversible pulpitis or asymptomatic pulpal necrosis with or without periapical lesions. The obturation sealers used were AH Plus, Endomethasone-N, and Sealer Plus. Postoperative pain intensity was recorded by patients using a modified numerical rating scale (NRS) ranging from 0 (no pain) to 10 (severe pain). No statistically significant differences in pain scores were found at 12, 24, or 48 h in relation to gender, age, tooth position, pulpal diagnosis, type of sealer, or extrusion (p > 0.05). The most common pain levels classified as uncomfortable were observed at 12 and 24 h, while 94.1% of patients reported no pain at 48 h; the remaining pain was mild. Pain scores decreased significantly after 48 h for all variables. Single-session endodontic treatment with foraminal instrumentation showed a low incidence of postoperative pain that was not influenced by the variables analyzed in this study. The null hypothesis was that there was no association between the occurrence of postoperative pain and (i) age, (ii) patient gender, (iii) pulp diagnosis, (iv) tooth position, (v) endodontic sealer type, and (vi) sealer extrusion.
- 1 April 2026
- Vol. 12 (2) , e70313
Open AccessEvaluation of Postoperative Pain Frequency in Single-Session Endodontic Treatments With Patency and Foraminal Enlargement.
This study aimed to evaluate the incidence of postoperative pain in single-session endodontic treatments with foraminal instrumentation, considering factors such as pulpal diagnosis, tooth position, type of endodontic sealer, and sealer extrusion. Treatments were performed on 153 teeth of patients aged 12-80 years diagnosed with asymptomatic irreversible pulpitis or asymptomatic pulpal necrosis with or without periapical lesions. The obturation sealers used were AH Plus, Endomethasone-N, and Sealer Plus. Postoperative pain intensity was recorded by patients using a modified numerical rating scale (NRS) ranging from 0 (no pain) to 10 (severe pain). No statistically significant differences in pain scores were found at 12, 24, or 48 h in relation to gender, age, tooth position, pulpal diagnosis, type of sealer, or extrusion (p > 0.05). The most common pain levels classified as uncomfortable were observed at 12 and 24 h, while 94.1% of patients reported no pain at 48 h; the remaining pain was mild. Pain scores decreased significantly after 48 h for all variables. Single-session endodontic treatment with foraminal instrumentation showed a low incidence of postoperative pain that was not influenced by the variables analyzed in this study. The null hypothesis was that there was no association between the occurrence of postoperative pain and (i) age, (ii) patient gender, (iii) pulp diagnosis, (iv) tooth position, (v) endodontic sealer type, and (vi) sealer extrusion.
- Open Access
- 28 February 2026
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 51 (1)
Analysis of the reciprocating kinematics of the VDW Silver Reciproc, E-Connect Pro, Ecom, and Endopen endodontic motors: an in vitro experimental study
Analysis of the reciprocating kinematics of the VDW Silver Reciproc, E-Connect Pro, Ecom, and Endopen endodontic motors: an in vitro experimental study
- 28 February 2026
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 51 (1)
Open AccessAnalysis of the reciprocating kinematics of the VDW Silver Reciproc, E-Connect Pro, Ecom, and Endopen endodontic motors: an in vitro experimental study
Analysis of the reciprocating kinematics of the VDW Silver Reciproc, E-Connect Pro, Ecom, and Endopen endodontic motors: an in vitro experimental study
- Open Access
- 23 February 2026
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 12 (2)
Evaluation of Postoperative Pain Frequency in Single‐Session Endodontic Treatments With Patency and Foraminal Enlargement
Objective: This study aimed to evaluate the incidence of postoperative pain in single‐session endodontic treatments with foraminal instrumentation, considering factors such as pulpal diagnosis, tooth position, type of endodontic sealer, and sealer extrusion. Materials and Methods: Treatments were performed on 153 teeth of patients aged 12–80 years diagnosed with asymptomatic irreversible pulpitis or asymptomatic pulpal necrosis with or without periapical lesions. The obturation sealers used were AH Plus, Endomethasone‐N, and Sealer Plus. Postoperative pain intensity was recorded by patients using a modified numerical rating scale (NRS) ranging from 0 (no pain) to 10 (severe pain). Results: No statistically significant differences in pain scores were found at 12, 24, or 48 h in relation to gender, age, tooth position, pulpal diagnosis, type of sealer, or extrusion ( p > 0.05). The most common pain levels classified as uncomfortable were observed at 12 and 24 h, while 94.1% of patients reported no pain at 48 h; the remaining pain was mild. Pain scores decreased significantly after 48 h for all variables. Conclusion: Single‐session endodontic treatment with foraminal instrumentation showed a low incidence of postoperative pain that was not influenced by the variables analyzed in this study. Null Hypothesis: The null hypothesis was that there was no association between the occurrence of postoperative pain and (i) age, (ii) patient gender, (iii) pulp diagnosis, (iv) tooth position, (v) endodontic sealer type, and (vi) sealer extrusion.
- 23 February 2026
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 12 (2)
Open AccessEvaluation of Postoperative Pain Frequency in Single‐Session Endodontic Treatments With Patency and Foraminal Enlargement
Objective: This study aimed to evaluate the incidence of postoperative pain in single‐session endodontic treatments with foraminal instrumentation, considering factors such as pulpal diagnosis, tooth position, type of endodontic sealer, and sealer extrusion. Materials and Methods: Treatments were performed on 153 teeth of patients aged 12–80 years diagnosed with asymptomatic irreversible pulpitis or asymptomatic pulpal necrosis with or without periapical lesions. The obturation sealers used were AH Plus, Endomethasone‐N, and Sealer Plus. Postoperative pain intensity was recorded by patients using a modified numerical rating scale (NRS) ranging from 0 (no pain) to 10 (severe pain). Results: No statistically significant differences in pain scores were found at 12, 24, or 48 h in relation to gender, age, tooth position, pulpal diagnosis, type of sealer, or extrusion ( p > 0.05). The most common pain levels classified as uncomfortable were observed at 12 and 24 h, while 94.1% of patients reported no pain at 48 h; the remaining pain was mild. Pain scores decreased significantly after 48 h for all variables. Conclusion: Single‐session endodontic treatment with foraminal instrumentation showed a low incidence of postoperative pain that was not influenced by the variables analyzed in this study. Null Hypothesis: The null hypothesis was that there was no association between the occurrence of postoperative pain and (i) age, (ii) patient gender, (iii) pulp diagnosis, (iv) tooth position, (v) endodontic sealer type, and (vi) sealer extrusion.
- Open Access
- 3 October 2025
- Published by Universidade Estadual de Campinas in Brazilian Journal of Oral Sciences
- Vol. 24, e251948
Cyclic fatigue resistanceof Hyflex EDM NiTi rotaryfiles in different distancesof pecking motion
Aim: The purpose of this study was to evaluate the effect of different distances of pecking motion on the cyclic fatigue of Hyflex EDM OneFile (Coltene/Whaledent AG, Altstatten, Switzerland) in simulated curved canal. Methods: Sixty Hyflex EDM OneFile (#25/0.08) files were tested at three different pecking depths: G(1): 1-mm depth, G(2): 2-mm depth, G(3): 3-mm depth, and G(4): 4-mm depth. Cyclic fatigue resistance was tested measuring the time to fracture and the number of cycles to failure (NCF) in an artificial canal with a 60° angle and a 3-mm radius of curvature. Data were analyzed using the analysis of variance test and the Student-Newman-Keuls test for multiple comparisons. Results: There was a significant difference between the four groups for the NCF (p < 0.05). G(1) group had lower NCF compared to the other groups. There was a significant difference between group 4 (1278.9) and the others (p < 0.05). Groups 2 and 3, with NCF means of 714.4 and 872.2, respectively, did not show any significant difference between them (p > 0.05). Conclusion: The results showed that different pecking distances can significantly extend the life span of Hyflex EDM rotary files. Our results suggest that a longer pecking depth may reduce the risk of instrument fracture.
- 3 October 2025
- Published by Universidade Estadual de Campinas in Brazilian Journal of Oral Sciences
- Vol. 24, e251948
Open AccessCyclic fatigue resistanceof Hyflex EDM NiTi rotaryfiles in different distancesof pecking motion
Aim: The purpose of this study was to evaluate the effect of different distances of pecking motion on the cyclic fatigue of Hyflex EDM OneFile (Coltene/Whaledent AG, Altstatten, Switzerland) in simulated curved canal. Methods: Sixty Hyflex EDM OneFile (#25/0.08) files were tested at three different pecking depths: G(1): 1-mm depth, G(2): 2-mm depth, G(3): 3-mm depth, and G(4): 4-mm depth. Cyclic fatigue resistance was tested measuring the time to fracture and the number of cycles to failure (NCF) in an artificial canal with a 60° angle and a 3-mm radius of curvature. Data were analyzed using the analysis of variance test and the Student-Newman-Keuls test for multiple comparisons. Results: There was a significant difference between the four groups for the NCF (p < 0.05). G(1) group had lower NCF compared to the other groups. There was a significant difference between group 4 (1278.9) and the others (p < 0.05). Groups 2 and 3, with NCF means of 714.4 and 872.2, respectively, did not show any significant difference between them (p > 0.05). Conclusion: The results showed that different pecking distances can significantly extend the life span of Hyflex EDM rotary files. Our results suggest that a longer pecking depth may reduce the risk of instrument fracture.
- Open Access
- 13 November 2024
- Published by Universidade Estadual de Campinas in Brazilian Journal of Oral Sciences
- Vol. 23, e242997
Evaluation of the physicochemical properties of intracanal medications used in traumatized teeth
Aim: The aim of the present study was to evaluate the solubility, flow and radiopacity of Calen (SS White Artigos Dentários Ltd, Rio de Janeiro, Brazil), Calen with zinc oxide (Calen/ZnO), calcium hydroxide + zinc oxide + 2% chlorhexidine (CH/ZnO/CHX), Calplus and Ultracal XS. Methods: 28 bovine incisor specimens were standardized, instrumented and filled with pastes with the aid of a centrix syringe. To assess solubility, the root canals of acrylic teeth (N = 10) were filled with the previously mentioned pastes and scanned by using micro–computed tomography before (initial) and after 7 days of immersion in ultrapure water. The solubility of each specimen was the difference between the initial and final volume. Flow properties were analysed according to the ISO 6876/2012 standard. Radiopacity was radiographically analysed by using Image J software. Data were submitted to analysis of variance and Tukey’s test (alpha 5%). Results: CH/ZnO/CHX and Calplus presented similar values regarding radiopacity. The group composed of Calen paste showed higher flow values. As for solubility, CH/ZnO/ CHX showed lower volume loss, but there was no statistical difference compared to other medications. Conclusion: The medication composed of calcium hydroxide, zinc oxide and 2% chlorhexidine is a suitable alternative for use in traumatized teeth.
- 13 November 2024
- Published by Universidade Estadual de Campinas in Brazilian Journal of Oral Sciences
- Vol. 23, e242997
Open AccessEvaluation of the physicochemical properties of intracanal medications used in traumatized teeth
Aim: The aim of the present study was to evaluate the solubility, flow and radiopacity of Calen (SS White Artigos Dentários Ltd, Rio de Janeiro, Brazil), Calen with zinc oxide (Calen/ZnO), calcium hydroxide + zinc oxide + 2% chlorhexidine (CH/ZnO/CHX), Calplus and Ultracal XS. Methods: 28 bovine incisor specimens were standardized, instrumented and filled with pastes with the aid of a centrix syringe. To assess solubility, the root canals of acrylic teeth (N = 10) were filled with the previously mentioned pastes and scanned by using micro–computed tomography before (initial) and after 7 days of immersion in ultrapure water. The solubility of each specimen was the difference between the initial and final volume. Flow properties were analysed according to the ISO 6876/2012 standard. Radiopacity was radiographically analysed by using Image J software. Data were submitted to analysis of variance and Tukey’s test (alpha 5%). Results: CH/ZnO/CHX and Calplus presented similar values regarding radiopacity. The group composed of Calen paste showed higher flow values. As for solubility, CH/ZnO/ CHX showed lower volume loss, but there was no statistical difference compared to other medications. Conclusion: The medication composed of calcium hydroxide, zinc oxide and 2% chlorhexidine is a suitable alternative for use in traumatized teeth.
- 25 October 2024
- Published by Wiley in Australian Endodontic Journal
- Vol. 50 (3) , 658-666
Acid‐etching protocol for bioceramic cements: Evaluation of bond strength, compression and morphology
To establish an acid‐etching protocol for Biodentine and Cimmo DTA, evaluating compressive strength, bond strength, surface morphology in scanning electron microscope and failure modes after different etching times. Two test specimens were prepared for each cement and divided into four groups (n = 12) according to the acid‐etching time (0, 5, 10 and 15 s). Compressive strength was tested using a universal testing machine, while bond strength was evaluated after bonding with Filtek Bulk Flow resin using Universal ESPE Single Bond adhesive. Failures were classified as surface‐adhesive, cement‐cohesive, resin‐cohesive and mixed. Biodentine showed significantly higher compressive strength than Cimmo DTA (p < 0.001), regardless of acid etch time (p < 0.001). Different acid‐etching strategies are required for Biodentine and Cimmo DTA, with Biodentine requiring selective etching and Cimmo DTA requiring a full 15‐s etch to optimise bond strength properties.
- 25 October 2024
- Published by Wiley in Australian Endodontic Journal
- Vol. 50 (3) , 658-666
Acid‐etching protocol for bioceramic cements: Evaluation of bond strength, compression and morphology
To establish an acid‐etching protocol for Biodentine and Cimmo DTA, evaluating compressive strength, bond strength, surface morphology in scanning electron microscope and failure modes after different etching times. Two test specimens were prepared for each cement and divided into four groups (n = 12) according to the acid‐etching time (0, 5, 10 and 15 s). Compressive strength was tested using a universal testing machine, while bond strength was evaluated after bonding with Filtek Bulk Flow resin using Universal ESPE Single Bond adhesive. Failures were classified as surface‐adhesive, cement‐cohesive, resin‐cohesive and mixed. Biodentine showed significantly higher compressive strength than Cimmo DTA (p < 0.001), regardless of acid etch time (p < 0.001). Different acid‐etching strategies are required for Biodentine and Cimmo DTA, with Biodentine requiring selective etching and Cimmo DTA requiring a full 15‐s etch to optimise bond strength properties.
- Open Access
- 16 October 2024
- Published by MDPI AG in Dentistry Journal
- Vol. 12 (10) , 330
ProDesign Logic Files Effect on Apical Foramen Wear and Shape Transformation After Foraminal Enlargement
Background/Objectives: This study aimed to evaluate the effect of ProDesign Logic files 45.01 and 50.01 on apical foramen wear and shape transformation after foraminal enlargement at tooth length (TL) and 1 mm beyond. Methods: Sixty freshly extracted single-rooted lower human premolars teeth were distributed randomly into five groups (n = 12): Group 1 (40.05 WL) (control): No foraminal enlargement, Group 2 (45.01 TL): Specimens underwent foraminal enlargement with 45.01 Prodesign Logic file at TL; Group 3 (45.01 TL + 1): Specimens underwent foraminal enlargement with 45.01 Prodesign Logic file at 1 mm beyond TL; Group 4 (50.01 TL): Specimens underwent foraminal enlargement with 50.01 Prodesign Logic file at TL; Group 5 (50.01 TL + 1): Specimens underwent foraminal enlargement with 50.01 Prodesign Logic file at 1 mm beyond TL. Scanning electron microscopy was used to evaluate apical foramen variations and shape alterations. Data were analyzed by Student’s t-test, Kruskal–Wallis, and Mann–Whitney test. Results: Significant differences (p < 0.01) were observed among all tested groups compared to the control group in terms of the average worn area of the apical foramen. Foraminal enlargement led to significant shape transformation, resulting in round-shaped foramina. Conclusion: ProDesign Logic 45.01 and 50.01 files at TL causes notable wear and round-shaped foramina.
- 16 October 2024
- Published by MDPI AG in Dentistry Journal
- Vol. 12 (10) , 330
Open AccessProDesign Logic Files Effect on Apical Foramen Wear and Shape Transformation After Foraminal Enlargement
Background/Objectives: This study aimed to evaluate the effect of ProDesign Logic files 45.01 and 50.01 on apical foramen wear and shape transformation after foraminal enlargement at tooth length (TL) and 1 mm beyond. Methods: Sixty freshly extracted single-rooted lower human premolars teeth were distributed randomly into five groups (n = 12): Group 1 (40.05 WL) (control): No foraminal enlargement, Group 2 (45.01 TL): Specimens underwent foraminal enlargement with 45.01 Prodesign Logic file at TL; Group 3 (45.01 TL + 1): Specimens underwent foraminal enlargement with 45.01 Prodesign Logic file at 1 mm beyond TL; Group 4 (50.01 TL): Specimens underwent foraminal enlargement with 50.01 Prodesign Logic file at TL; Group 5 (50.01 TL + 1): Specimens underwent foraminal enlargement with 50.01 Prodesign Logic file at 1 mm beyond TL. Scanning electron microscopy was used to evaluate apical foramen variations and shape alterations. Data were analyzed by Student’s t-test, Kruskal–Wallis, and Mann–Whitney test. Results: Significant differences (p < 0.01) were observed among all tested groups compared to the control group in terms of the average worn area of the apical foramen. Foraminal enlargement led to significant shape transformation, resulting in round-shaped foramina. Conclusion: ProDesign Logic 45.01 and 50.01 files at TL causes notable wear and round-shaped foramina.