BNBruna Egumi Nagay

Bruna Egumi Nagay

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bruna Egumi Nagay has a total of 165 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of polishing on hybrid CAD/CAM ceramics after gastric acid

    by Joao Pedro Justino De Oliveira Limírio, Tielly Nogueira Fetti, Gabriel Nunes Sampaio, Bruna Egumi Nagay, Jessica Marcela de Luna Gomes, Aldieris Alves Pesqueira, Eduardo Piza Pellizzer

    Objetivo: Avaliar a influência de diferentes sistemas de polimento e do desafio erosivo por ácido gástrico simulado sobre a rugosidade superficial e a microdureza Vickers de cerâmicas híbridas CAD/CAM. Material e método: Quarenta espécimes (n=10/grupo) de uma cerâmica infiltrada por polímero (VITA Enamic) e de uma resina nanocerâmica (Cerasmart) foram distribuídos em quatro grupos, conforme o material e o sistema de polimento: sistema convencional para cerâmica (CPS) ou sistema específico para materiais híbridos (HSP). A rugosidade superficial (Ra) e a microdureza Vickers (VHN) foram avaliadas após 24 horas e após imersão cumulativa em ácido clorídrico a 5% (pH 2,0) por 91, 182 e 455 horas, períodos cumulativos simulados de exposição ao ácido gástrico. Os dados foram analisados por ANOVA de três fatores com medidas repetidas e teste de Tukey (α=0,05). Resultado: Houve interação significativa entre material, sistema de polimento e período de avaliação para ambas as variáveis (p<0,05). O HSP reduziu significativamente a rugosidade da VITA Enamic em todos os períodos avaliados (p<0,001), enquanto não houve benefício consistente para a Cerasmart. Independentemente do protocolo de polimento, a VITA Enamic apresentou maior microdureza que a Cerasmart (p<0,001). O desafio erosivo reduziu a microdureza de ambos os materiais ao longo do tempo. Conclusão: O sistema de polimento específico para materiais híbridos proporcionou menor rugosidade superficial comparado à cerâmica infiltrada por polímero, enquanto não foi observado benefício consistente para a resina nanocerâmica. A exposição ao ácido gástrico simulado foi associada a reduções na microdureza em períodos específicos de avaliação em ambos os materiais. Esses achados estão limitados às propriedades superficiais avaliadas nas condições experimentais do estudo.

  • Open Access

    Charge-Driven Engineering of Titanium Implants with Chitosan and Poly- l -Lysine for Dual Antiadhesive and Anticorrosive Functionality

    by Ayrton G. Silva, João Pedro dos S. Silva, João Victor C. Cordeiro, Nilson C da Cruz, Elidiane C. Rangel, Carlos A. Fortulan, Jamil A. Shibli, Conrado R. M. Afonso, Daniel G. S. dos Santos, Luciene Figueiredo, et al.

    Peri-implant infections remain a major cause of implant failure, motivating the development of multifunctional titanium surfaces capable of preventing bacterial colonization while preserving implant performance. Herein, a chitosan/poly-l-lysine (CH-PLL) bilayer coating was engineered on hydroxyl-rich titanium surfaces generated by hydrothermal treatment (HT) or plasma electrolytic oxidation (PEO). We hypothesized that the CH-PLL bilayer would establish a stable cationic interface capable of impairing early bacterial adhesion and modulating polymicrobial biofilm development, whereas the PEO substrate would provide superior mechanical and electrochemical stability. Surface characterization confirmed successful bilayer formation and showed that PLL functionalization increased positive surface charge and hydrophilicity while improving tribological and electrochemical performance, with the PEO@CH-PLL coating exhibiting a friction coefficient of ∼0.01 and significantly enhanced corrosion resistance (P < 0.05). Accordingly, PLL-coated surfaces reduced bacterial adhesion by 3.9 and 3.1 log CFU for Staphylococcus aureus and Escherichia coli, respectively. Against a saliva-derived polymicrobial biofilm, the coating reduced the total bacterial burden by ∼1.8 log while suppressing disease-related peri-implant pathogens. Importantly, these antibacterial effects were accompanied by preserved protein adsorption and enhanced preosteoblastic activity after 7 days. Collectively, these findings demonstrate that combining a stable cationic CH-PLL interface with a PEO-generated oxide layer provides a multifunctional titanium surface integrating biofilm control with improved mechanical, electrochemical, and biological performance.

  • Open Access

    Photoresponsive Bilayer Coating Integrating a Porous Zinc Oxide Layer and a Chitosan–Antibiotic Drug Delivery System for Antimicrobial Photodynamic Therapy in Biomedical Implants

    by Samuel S. Malheiros, Maria Helena R. P. Borges, Elidiane C. Rangel, Nilson C. Cruz, Carlos A. Fortulan, Xi Rao, Liqun Xu, João Gabriel S. Souza, Eduardo B. Moffa, Bruna E. Nagay, et al.

    Peri-implant infections remain a major cause of implant failure, highlighting the need for antimicrobial implant surfaces capable of suppressing biofilm formation while preserving the physicochemical and biological features needed for osseointegration. Here, we engineered a photoresponsive bilayer coating on titanium by anchoring a photosensitive antibiotic, demeclocycline (DMC), loaded into a polymeric chitosan film onto a zinc-doped porous oxide layer produced by plasma electrolytic oxidation (PEO). The inner PEO/Zn layer generated a porous ZnO-containing TiO2 matrix that provided mechanical interlocking for the polymeric film. The outer polymeric chitosan film deposition reduced surface roughness and hydrophilicity and enabled DMC incorporation. Chemical analyses confirmed the stepwise construction of the bilayer coating, revealing TiO2/ZnO porous oxide layer formation and chitosan and DMC incorporation. ROS generation under blue light was confirmed by the DCFH-DA fluorescence assay. Mechanically, the bilayer coating decreased the friction coefficient by approximately 75%, with the chitosan layer acting as a lubricating barrier under tribological stress. DMC release was sustained for 21 days with lysozyme-mediated degradation accelerating early drug release. Against saliva-derived polymicrobial biofilms formed for 96 h, the DMC-loaded coating reduced viable counts by approximately 2-log units under dark conditions, confirming intrinsic antibacterial activity. Upon blue light irradiation, the reduction reached approximately 3-log units, indicating on-demand photodynamic enhancement of the antimicrobial effect mediated by ROS. This response was accompanied by reduced metabolic activity, lower biofilm mass and matrix protein content, increased membrane-compromised cells assessed by live/dead, and suppression of more pathogenic microbial complexes. The coating also retained antibiofilm activity after microbial recolonization and the reusability of photodynamic therapy. Beyond antimicrobial activity, the coating preserved preosteoblastic cell viability and supported hydroxyapatite nucleation. Proteomic analysis showed an enriched immune, coagulation, protease-regulatory, and structural pathway proteomic profile. Overall, this bilayer platform integrates mechanical stability, sustained antibiotic delivery, and light-activated antimicrobial photodynamic therapy, representing a promising multifunctional coating for the control of implant infection.

  • Open Access

    Synergistic antibacterial effect of photocatalytic coatings activated by visible light and photodynamic therapy for rapid peri-implantitis treatment

    by Bruna Egumi Nagay, Raphael Cavalcante Costa, Samuel Santana Malheiros, Jairo Matozinho Cordeiro, Caroline Dini, Ariane Bezerra Santos, Cristiane Cantiga, Barbara Ribeiro Rios, Xiang Li, Zhang Ruixin, et al.

    Biofilm accumulation and subsequent implant-related infections pose significant challenges in the biomedical field. Photocatalytic coatings hold promise for antimicrobial efficacy; however, their effectiveness in dynamic polymicrobial infections for clinical use remains a novel and ongoing challenge. To address this, combining visible-light-triggered photocatalytic coatings with methylene blue-mediated photodynamic therapy (MB-PDT) has the potential to optimize treatment efficacy and simplify multifunctional coating designs for diverse implant therapy needs. Herein, a one-step plasma electrolytic oxidation technique is employed to create a photocatalytic coating composed of crystalline titanium dioxide (TiO2) doped with bismuth (Bi-TiO2). This coating enhances bioactivity, hardness, and wear resistance, which are favorable properties for an implant biointerface. Furthermore, this coating generates reactive oxygen species (ROS) under visible light, which is robustly boosted when combined with MB-PDT due to the synergistic wavelength absorption between Bi-TiO2 and methylene blue, leading to highly effective microbial eradication within just 1 min of treatment. Further in vivo assays confirm the antimicrobial efficacy and demonstrate a reduction in inflammatory responses, thereby favoring the wound repair process. Our proof-of-concept data offer a promising solution for peri-implant infections, using visible-light-driven photocatalytic coatings in combination with PDT to combat biofilm-related infections while maintaining the properties that affect the longevity of dental implants.

  • Open Access

    Citric acid promotes effective in vitro decontamination of titanium while supporting surface, electrochemical, and biological properties compared with conventional chemical agents

    by Mirtes Maria Ferreira Corrêa, Mariana Alves Santos, Cícero Andrade Sigilião Celles, João Pedro dos Santos Silva, Maria Helena Rossy Borges, Samuel Santana Malheiros, Elidiane Cipriano Rangel, Jairo Matozinho Cordeiro, Ana Paula de Souza, Valentim A.R. Barão, et al.

  • Open Access

    Surface Modifications of cpTi and Ti-6Al-4V: The Synergistic Potential of PEO-CaP for Optimized Dental Implant Performance

    by Júlia M. T. Teodoro, Maria H. R. Borges, Raphael C. Costa, Jairo M. Cordeiro, Elidiane Rangel, Nilson C. Da Cruz, Carlos A. Fortulan, Bruna E. Nagay, Valentim A. R. Barão

  • Open Access

    Dual-function thermoresponsive antibiotic-loaded hydrogel with antimicrobial and osteogenic properties for implant-related infection control

    by Caroline Dini, Stéfany Barbosa Alves da Cruz, Rodolfo D. Piazza, Bruna E. Nagay, Rodrigo F.C. Marques, Renato C.V. Casarin, Fang Yang, Magda Feres, Jet Liu, Batbileg Bor, et al.

    Implant-related infections demand advanced biomaterials capable of delivering localized, sustained antimicrobial activity while supporting tissue repair. Here, we present an engineered thermoresponsive hydrogel based on poly(N-vinylcaprolactam) (PNVCL), designed as a dual-function platform that enables temperature-triggered gelation, controlled tetracycline release, and osteogenic support. The PNVCL network was tailored to provide rapid sol–gel transition at physiological temperature, strong adhesion to moist surfaces, injectability into narrow implant geometries, high swelling capacity, slow degradation, and a stable drug-release profile—properties rarely combined within a single hydrogel system. To evaluate material performance, we employed a tiered biological framework comprising cytocompatibility assays, controlled physicochemical analyses, and antimicrobial testing against complex, polymicrobial biofilms, complemented by human in situ and in vivo multispecies infection models. The PNVCL–tetracycline hydrogel demonstrated potent antibacterial activity, preserved human gingival fibroblast viability, and sustained its structural integrity and release characteristics even under infection-associated inflammatory conditions. In vivo, the material simultaneously reduced bacterial burden, modulated pathogenic community structure, and promoted new bone formation with a higher degree of maturation, confirming its dual antimicrobial and osteogenic behavior. By integrating precisely engineered thermoresponsive behavior, controlled drug delivery, robust mechanical and interfacial properties, and validated biological functionality, this PNVCL–tetracycline hydrogel represents a material-driven, clinically relevant solution for treating implant-related infections.


  • Open Access

    Impact of prosthetic abutment design on peri‐implant clinical and esthetic outcomes: A systematic review and meta‐analysis of randomized controlled trials

    by João Vicente Calazans Neto, Cícero A. Sigilião Celles, Guilherme Almeida Borges, Valentim A. R. Barão, Bruna Egumi Nagay

    Purpose: To investigate, based exclusively on randomized controlled trials (RCTs), the current evidence on the influence of different prosthetic abutment designs on peri‐implant clinical outcomes and esthetic parameters. Methods: This systematic review and meta‐analysis of RCTs was conducted following the Preferred Reporting Items for Systematic Reviews and Meta‐Analyses (PRISMA) 2020 guidelines. A comprehensive and systematic search was conducted across multiple databases and gray literature, including MEDLINE/PubMed, Scopus, Web of Science, Embase, ReBEC, Trials, Virtual Health Library, and ProQuest, to identify RCTs comparing different abutment designs. Abutments were categorized into narrowed (concave, curved), straight (linear, convex, cylindrical), and widened (wide) profiles. The primary outcomes were marginal bone loss (MBL), probing depth (PD), and Pink Esthetic Score (PES), all assessed through meta‐analyses. Secondary outcomes included abutment survival, biological and technical complications, as well as additional aesthetic parameters, including mid‐facial mucosal zenith (MMZ), keratinized mucosa width (KMW), mucosal thickness (MT), mucosa position (MP), and soft tissue profile (SP). Risk of bias was assessed using the Cochrane RoB 2.0 tool, and the certainty of evidence was evaluated according to the GRADE approach. Results: The search resulted in 10,566 studies; after removal of duplicates, 5270 studies remained. Of those, 5252 were excluded based on title and abstract screening. Ultimately, 10 RCTs with follow‐ups ranging from 3 to 60 months were included for quantitative and qualitative assessments. Of these, six provided data that could be pooled and were included in the quantitative analysis. Risk of bias varied among studies, with high risk observed in 2 RCTs, some concerns in 5 studies, and low risk in 3 studies, primarily related to outcome measurement and blinding, as assessed using the RoB 2.0 tool. Overall certainty of evidence was rated moderate. The meta‐analyses showed no statistically significant difference in MBL, PD or PES between narrowed and straight profiles (MBL: SMD = 0.08, p = 0.66); PD: SMD = −0.05, p = 0.80; PES: SMD = −0.12, p = 0.51). Additionally, no differences were found in biological or esthetic outcomes between abutment types, with stable peri‐implant parameters and high patient satisfaction. Technical complications were rare, involving early failures and occasional fractures, especially in concave abutments. Conclusion: Based on the current evidence and within the limitations of the included studies, abutment shape does not appear to significantly influence peri‐implant tissue response or esthetic outcomes. Further well‐designed RCTs with standardized protocols, adequate sample sizes, and longer follow‐up are required to increase the certainty of the evidence and improve the external validity of the findings.

  • Open Access

    Effect of probiotics on oral biofilm formation on titanium and SLA implant surfaces: An in vitro and in situ study

    by Thais Terumi S. Takeda, Maria Helena R. Borges, Samuel Santana Malheiros, Raphael Cavalcante Costa, Martinna de Mendonça e Bertolini, Bruna E. Nagay, João Gabriel S. Souza, Valentim A.R. Barão


  • Open Access

    Alignment of artificial intelligence-generated responses with systematic reviews in implant prosthodontics

    by João Vicente Calazans Neto, Juliana Dela Líbera, João Gabriel S. Souza, Bruna Egumi Nagay, Valentim A.R. Barão