Stefano Rossi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Stefano Rossi has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Ramalli
University of Florence
5 shared publications P. Tortoli
University of Florence, Florence, Italy
4 shared publicationsA. Ramalli
University of Florence, Florence, Italy
2 shared publications- Enrico Boni
University of Florence
2 shared publications F. Guidi
University of Florence, Florence, Italy
2 shared publications- Piero Tortoli
University of Florence
2 shared publications
Latest Publications
- 28 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (8) , 2707-2715
On the Depth-Dependent Accuracy of Plane-Wave-Based Vector Velocity Measurements With Linear Arrays
High-frame-rate vector Doppler methods are used to measure blood velocities over large 2-D regions, but their accuracy is often estimated over a short range of depths. This article thoroughly examines the dependence of velocity measurement accuracy on the target position. Simulations were carried out on flat and parabolic flow profiles, for different Doppler angles, and considering a 2-D vector flow imaging (2-D VFI) method based on plane wave transmission and speckle tracking. The results were also compared with those obtained by the reference spectral Doppler (SD) method. Although, as expected, the bias and standard deviation generally tend to worsen at increasing depths, the measurements also show the following. First, the errors are much lower for the flat profile (from ≈ -4 ± 3% at 20 mm to ≈ -17 ± 4% at 100 mm) than for the parabolic profile (from ≈ -4 ± 3% to ≈ -38 ±%). Second, only part of the relative estimation error is related to the inherent low resolution of the 2-D VFI method. For example, even for SD, the error bias increases (on average) from -0.7% (20 mm) to -17% (60 mm) up to -26% (100 mm). Third, conversely, the beam divergence associated with the linear array acoustic lens was found to have a great impact on the velocity measurements. By simply removing such lens, the average bias for 2-D VFI at 60 and 100 mm dropped down to -9.4% and -19.4%, respectively. In conclusion, the results indicate that the transmission beam broadening on the elevation plane, which is not limited by reception dynamic focusing, is the main cause of velocity underestimation in the presence of high spatial gradients.
- 28 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (8) , 2707-2715
On the Depth-Dependent Accuracy of Plane-Wave-Based Vector Velocity Measurements With Linear Arrays
High-frame-rate vector Doppler methods are used to measure blood velocities over large 2-D regions, but their accuracy is often estimated over a short range of depths. This article thoroughly examines the dependence of velocity measurement accuracy on the target position. Simulations were carried out on flat and parabolic flow profiles, for different Doppler angles, and considering a 2-D vector flow imaging (2-D VFI) method based on plane wave transmission and speckle tracking. The results were also compared with those obtained by the reference spectral Doppler (SD) method. Although, as expected, the bias and standard deviation generally tend to worsen at increasing depths, the measurements also show the following. First, the errors are much lower for the flat profile (from ≈ -4 ± 3% at 20 mm to ≈ -17 ± 4% at 100 mm) than for the parabolic profile (from ≈ -4 ± 3% to ≈ -38 ±%). Second, only part of the relative estimation error is related to the inherent low resolution of the 2-D VFI method. For example, even for SD, the error bias increases (on average) from -0.7% (20 mm) to -17% (60 mm) up to -26% (100 mm). Third, conversely, the beam divergence associated with the linear array acoustic lens was found to have a great impact on the velocity measurements. By simply removing such lens, the average bias for 2-D VFI at 60 and 100 mm dropped down to -9.4% and -19.4%, respectively. In conclusion, the results indicate that the transmission beam broadening on the elevation plane, which is not limited by reception dynamic focusing, is the main cause of velocity underestimation in the presence of high spatial gradients.
- Open Access
- 8 April 2021
- Published by MDPI AG in Electronics
- Vol. 10 (8) , 884
Embedded GPU Implementation for High-Performance Ultrasound Imaging
Methods of increasing complexity are currently being proposed for ultrasound (US) echographic signal processing. Graphics Processing Unit (GPU) resources allowing massive exploitation of parallel computing are ideal candidates for these tasks. Many high-performance US instruments, including open scanners like ULA-OP 256, have an architecture based only on Field-Programmable Gate Arrays (FPGAs) and/or Digital Signal Processors (DSPs). This paper proposes the implementation of the embedded NVIDIA Jetson Xavier AGX module on board ULA-OP 256. The system architecture was revised to allow the introduction of a new Peripheral Component Interconnect Express (PCIe) communication channel, while maintaining backward compatibility with all other embedded computing resources already on board. Moreover, the Input/Output (I/O) peripherals of the module make the ultrasound system independent, freeing the user from the need to use an external controlling PC.
- 8 April 2021
- Published by MDPI AG in Electronics
- Vol. 10 (8) , 884
Open AccessEmbedded GPU Implementation for High-Performance Ultrasound Imaging
Methods of increasing complexity are currently being proposed for ultrasound (US) echographic signal processing. Graphics Processing Unit (GPU) resources allowing massive exploitation of parallel computing are ideal candidates for these tasks. Many high-performance US instruments, including open scanners like ULA-OP 256, have an architecture based only on Field-Programmable Gate Arrays (FPGAs) and/or Digital Signal Processors (DSPs). This paper proposes the implementation of the embedded NVIDIA Jetson Xavier AGX module on board ULA-OP 256. The system architecture was revised to allow the introduction of a new Peripheral Component Interconnect Express (PCIe) communication channel, while maintaining backward compatibility with all other embedded computing resources already on board. Moreover, the Input/Output (I/O) peripherals of the module make the ultrasound system independent, freeing the user from the need to use an external controlling PC.
- 7 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Influence of the Acoustic Lens on Vector Doppler Measurements Based on Plane Wave Transmission: a Simulation Study
We recently showed that vector Doppler velocity measurements based on the transmission of plane waves by linear array probes may result strongly underestimated at great investigation depths. This paper investigates the contribution to such underestimation by the divergence of the beam due to the acoustic lens of the probe. Two identical 128-element linear arrays were simulated, one equipped with an acoustic lens focused at 20 mm and the second with a flat lens. Such probes were used to estimate the velocities of laminar flows located at different depths. The results show that the velocity profiles estimated for the array with the focused lens are accurate at the focal distance, but poor at greater depths. Conversely, estimations based on the array with a flat lens are less depth-dependent. For example, at 100 mm depth, the velocity estimates based on the unfocused lens are ≈18% more accurate. The shapes of the simulated one-way fields on the elevation plane highlight that the beam associated to the flat lens is significantly more uniform than that obtained with the focused lens. These results suggest that the lens should be properly designed when targeting accurate blood flow estimates over an extended range of interest.
- 7 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Influence of the Acoustic Lens on Vector Doppler Measurements Based on Plane Wave Transmission: a Simulation Study
We recently showed that vector Doppler velocity measurements based on the transmission of plane waves by linear array probes may result strongly underestimated at great investigation depths. This paper investigates the contribution to such underestimation by the divergence of the beam due to the acoustic lens of the probe. Two identical 128-element linear arrays were simulated, one equipped with an acoustic lens focused at 20 mm and the second with a flat lens. Such probes were used to estimate the velocities of laminar flows located at different depths. The results show that the velocity profiles estimated for the array with the focused lens are accurate at the focal distance, but poor at greater depths. Conversely, estimations based on the array with a flat lens are less depth-dependent. For example, at 100 mm depth, the velocity estimates based on the unfocused lens are ≈18% more accurate. The shapes of the simulated one-way fields on the elevation plane highlight that the beam associated to the flat lens is significantly more uniform than that obtained with the focused lens. These results suggest that the lens should be properly designed when targeting accurate blood flow estimates over an extended range of interest.
- 7 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Real-Time System for High Frame Rate Vector Flow Imaging
In a recently proposed high frame rate (HFR) Vector Flow Imaging (VFI) method, the displacements between consecutive beamformed radiofrequency (RF) frames are estimated from the corresponding phase shifts recorded in the frequency domain. Although such method is highly efficient, dedicated hardware would still be needed for a real-time implementation. In this work, we further reduce the computational load by processing demodulated and downsampled baseband (BB) data. Possible undesired effects on the accuracy of the proposed method were assessed. With respect to the RF processed data, simulations and experimental tests showed an average bias lower than 0.6%. A real-time version of the algorithm was implemented on the ULA-OP 256 system, including a high-speed clutter filter and the BB-VFI processing module. Preliminary tests showed that the real-time implementation can sustain up to 100k vector velocity estimates per second.
- 7 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Real-Time System for High Frame Rate Vector Flow Imaging
In a recently proposed high frame rate (HFR) Vector Flow Imaging (VFI) method, the displacements between consecutive beamformed radiofrequency (RF) frames are estimated from the corresponding phase shifts recorded in the frequency domain. Although such method is highly efficient, dedicated hardware would still be needed for a real-time implementation. In this work, we further reduce the computational load by processing demodulated and downsampled baseband (BB) data. Possible undesired effects on the accuracy of the proposed method were assessed. With respect to the RF processed data, simulations and experimental tests showed an average bias lower than 0.6%. A real-time version of the algorithm was implemented on the ULA-OP 256 system, including a high-speed clutter filter and the BB-VFI processing module. Preliminary tests showed that the real-time implementation can sustain up to 100k vector velocity estimates per second.
- 7 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Experimental Validation of a New Method for 3-D Vector Flow Imaging in the Frequency Domain
Current 3-D Vector Flow Imaging (VFI) techniques are typically limited by either low temporal resolution and/or high computational cost. In this work, we illustrate a 3-D high frame rate VFI method, which efficiently splits the 3-D (x, y, z) displacement estimation in two separate 2-D VFI estimations operated in the frequency domain. The echo-data received after the transmission of plane waves are beamformed and high-pass filtered before being VFI processed. The new method was experimentally tested by using the ULA-OP 256 research system connected to a 3 MHz, 256-element, 2-D spiral array. Phantom experiments were conducted in steady laminar flow conditions for different probe-to-flow angles. For the tested conditions, the mean relative bias was 11.5% with a standard deviation of 10.9%. The 2-step approach applied to the 2-D VFI technique makes the new 3-D VFI method accurate and computationally efficient.
- 7 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Experimental Validation of a New Method for 3-D Vector Flow Imaging in the Frequency Domain
Current 3-D Vector Flow Imaging (VFI) techniques are typically limited by either low temporal resolution and/or high computational cost. In this work, we illustrate a 3-D high frame rate VFI method, which efficiently splits the 3-D (x, y, z) displacement estimation in two separate 2-D VFI estimations operated in the frequency domain. The echo-data received after the transmission of plane waves are beamformed and high-pass filtered before being VFI processed. The new method was experimentally tested by using the ULA-OP 256 research system connected to a 3 MHz, 256-element, 2-D spiral array. Phantom experiments were conducted in steady laminar flow conditions for different probe-to-flow angles. For the tested conditions, the mean relative bias was 11.5% with a standard deviation of 10.9%. The 2-step approach applied to the 2-D VFI technique makes the new 3-D VFI method accurate and computationally efficient.
- Open Access
- 3 August 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (15) , 5365
High-Frame-Rate 3-D Vector Flow Imaging in the Frequency Domain
Ultrasound vector Doppler techniques for three-dimensional (3-D) blood velocity measurements are currently limited by low temporal resolution and high computational cost. In this paper, an efficient 3-D high-frame-rate vector Doppler method, which estimates the displacements in the frequency domain, is proposed. The novel method extends to 3-D an approach so far proposed for two-dimensional (2-D) velocity measurements by approximating the (x, y, z) displacement of a small volume through the displacements estimated for the 2-D regions parallel to the y and x directions, respectively. The new method was tested by simulation and experiments for a 3.7 MHz, 256-element, 2-D piezoelectric sparse spiral array. Simulations were also performed for an equivalent 7 MHz Capacitive Micromachined Ultrasonic Transducer spiral array. The results indicate performance (bias ± standard deviation: 6.5 ± 8.0) comparable to the performance obtained by using a linear array for 2-D velocity measurements. These results are particularly encouraging when considering that sparse arrays were used, which involve a lower signal-to-noise ratio and worse beam characteristics with respect to full 2-D arrays.
- 3 August 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (15) , 5365
Open AccessHigh-Frame-Rate 3-D Vector Flow Imaging in the Frequency Domain
Ultrasound vector Doppler techniques for three-dimensional (3-D) blood velocity measurements are currently limited by low temporal resolution and high computational cost. In this paper, an efficient 3-D high-frame-rate vector Doppler method, which estimates the displacements in the frequency domain, is proposed. The novel method extends to 3-D an approach so far proposed for two-dimensional (2-D) velocity measurements by approximating the (x, y, z) displacement of a small volume through the displacements estimated for the 2-D regions parallel to the y and x directions, respectively. The new method was tested by simulation and experiments for a 3.7 MHz, 256-element, 2-D piezoelectric sparse spiral array. Simulations were also performed for an equivalent 7 MHz Capacitive Micromachined Ultrasonic Transducer spiral array. The results indicate performance (bias ± standard deviation: 6.5 ± 8.0) comparable to the performance obtained by using a linear array for 2-D velocity measurements. These results are particularly encouraging when considering that sparse arrays were used, which involve a lower signal-to-noise ratio and worse beam characteristics with respect to full 2-D arrays.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 368-371
Performance of Ultrasound Vector Velocity Measurement at Great Depths
Ultrasound assessment of blood velocity vectors is usually performed on vessels, like the carotid artery, placed at shallow depths, while only few studies have been presented so far on the investigation of deep vessels. Some vector methods present clear disadvantages at great depth: for example, in multi-beam vector Doppler the inter-beam angle dramatically reduces due to the limited aperture. This problem, in principle, does not affect speckle tracking methods, which could potentially operate even with small transmission apertures. The aim of this work is to investigate the behavior, at different depths, of high frame rate Vector Flow Imaging methods based on the transmission of plane waves. Simulations show that accuracies better than 10% can be obtained for depths shallower than 6 cm but, at higher depths, the performance is significantly affected by the azimuthal broadening of the pressure field.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 368-371
Performance of Ultrasound Vector Velocity Measurement at Great Depths
Ultrasound assessment of blood velocity vectors is usually performed on vessels, like the carotid artery, placed at shallow depths, while only few studies have been presented so far on the investigation of deep vessels. Some vector methods present clear disadvantages at great depth: for example, in multi-beam vector Doppler the inter-beam angle dramatically reduces due to the limited aperture. This problem, in principle, does not affect speckle tracking methods, which could potentially operate even with small transmission apertures. The aim of this work is to investigate the behavior, at different depths, of high frame rate Vector Flow Imaging methods based on the transmission of plane waves. Simulations show that accuracies better than 10% can be obtained for depths shallower than 6 cm but, at higher depths, the performance is significantly affected by the azimuthal broadening of the pressure field.
- 11 May 2019
- Published by Springer Nature
- p. 129-135
Toward the Real Time Implementation of the 2-D Frequency-Domain Vector Doppler Method
- 11 May 2019
- Published by Springer Nature
- p. 129-135
Toward the Real Time Implementation of the 2-D Frequency-Domain Vector Doppler Method
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 29-32
Smart Ultrasound Sensor for Non-Destructive Tests
Ultrasounds plays a major role in Non-Destructive tests. An important application is the monitoring of the hardening process in cement-based materials. It was recently proven that ultrasound echoes reflected from the interface between a transmitting medium and the cement paste carry information about the status of the chemical process responsible of the cement hardening. In application like e.g. the monitoring of bridges or tunnels during construction, these sensors should be deployed in remote sites where they should work autonomously for days. Unfortunately, no electronics is currently available which satisfies the requirements for an industrial use. In this paper a completely configurable, embedded ultrasound system, capable of managing up to 8 ultrasound transducers, is presented. The proposed “smart” sensor can be remotely controlled through a web-based user-friendly interface, is portable, and can be programmed to perform a series of tests scheduled along days or months. An example of cement hydration process monitoring is presented to show the performances and versatility of the proposed system.
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 29-32
Smart Ultrasound Sensor for Non-Destructive Tests
Ultrasounds plays a major role in Non-Destructive tests. An important application is the monitoring of the hardening process in cement-based materials. It was recently proven that ultrasound echoes reflected from the interface between a transmitting medium and the cement paste carry information about the status of the chemical process responsible of the cement hardening. In application like e.g. the monitoring of bridges or tunnels during construction, these sensors should be deployed in remote sites where they should work autonomously for days. Unfortunately, no electronics is currently available which satisfies the requirements for an industrial use. In this paper a completely configurable, embedded ultrasound system, capable of managing up to 8 ultrasound transducers, is presented. The proposed “smart” sensor can be remotely controlled through a web-based user-friendly interface, is portable, and can be programmed to perform a series of tests scheduled along days or months. An example of cement hydration process monitoring is presented to show the performances and versatility of the proposed system.