Asad Mirza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Asad Mirza has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Sharan Ramaswamy
Florida International University
6 shared publications - Joshua D. Hutcheson
Department of Biomedical Engineering, Florida International University
4 shared publications - Daniel Chaparro
Department of Biomedical Engineering, Florida International University, Miami, FL 33174, USA
3 shared publications Anton Jan van Zonneveld
Department of Internal Medicine (Nephrology) and the Einthoven Laboratory for Vascular and Regenerative Medicine, Leiden University Medical Center, Leiden, 2333, ZA, Netherlands
2 shared publications- Ariadna Herrera
Florida International University
2 shared publications - Brittany A. Gonzalez
Department of Biomedical Engineering, Florida International University, Miami, FL 33174, USA
2 shared publications
Latest Publications
- Open Access
- 6 August 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-17
Computational Optimization of the Orbital Shaker Operational Parameters in Endothelial Mechanobiology
- 6 August 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-17
Open AccessComputational Optimization of the Orbital Shaker Operational Parameters in Endothelial Mechanobiology
- Open Access
- 24 January 2026
- Published by Elsevier in Acta Biomaterialia
- Vol. 213, 328-340
Exploring the link between disturbed flow and endothelial cell function in an in vitro arteriovenous fistula model
- 24 January 2026
- Published by Elsevier in Acta Biomaterialia
- Vol. 213, 328-340
Open AccessExploring the link between disturbed flow and endothelial cell function in an in vitro arteriovenous fistula model
- Open Access
Intrinsic Phenotypic Differences, Not Hemodynamic Shear, Associate with Cusp-Specific Remodeling in Aortic Valve Disease
Aortic valve disease (AVD) is asymmetric. Various clinical reports indicate that the non- coronary cusp (NCC) is disproportionally burdened by pathological remodeling like inflammation, fibrosis, and calcification. This has long been attributed to the resulting differences in hemodynamic load that arise from the presence, or lack thereof, of coronary ostia in respective sinuses. However, there is little to no empirical evidence to suggest that these differences in hemodynamic shear alone are enough to drive the difference in pathological remodeling that is observed. C57BL/6J mice exhibit a high variance in right coronary ostium (RCO) positioning with respect to the right coronary cusp (RCC). Through computational fluid dynamics (CFD) simulations of a mouse aortic valve (AoV) during end diastolic loading, we show negligible differences in wall shear stress (WSS) between a high RCO on the RCC and no ostium on the NCC. Also, though CFD analyses depict at least an order of magnitude difference in WSS through physiologically relevant ostia positions within the sinuses, ostium position does not correlate with calcification burden in a CKD mouse model of calcific AVD. Cusp dependent extracellular matrix (ECM) abundance analysis reveals asymmetric collagen and elastin content in healthy adult mice, but this does not follow the same trend as pathological remodeling. Instead, asymmetric abundance of elastin (P=0.034) and collagen (P=0.018) was mainly driven by an increase of these ECM proteins in the left coronary cusp (LCC) with no differences in leaflet thickness. Cusp dependent transcriptomic (spatial and bulk RNA sequencing) analyses reveal asymmetric phenotypic profiles between the three cusps in healthy adult mice. Of note, genes associated with vascular smooth muscle cell contraction and known modulators of AoV remodeling were upregulated in the NCC and downregulated in both the RCC and LCC. Together, these data suggest that the differences in shear resulting from the coronary ostia are not sufficient to explain the asymmetric onset of calcific AVD.
Open AccessIntrinsic Phenotypic Differences, Not Hemodynamic Shear, Associate with Cusp-Specific Remodeling in Aortic Valve Disease
Aortic valve disease (AVD) is asymmetric. Various clinical reports indicate that the non- coronary cusp (NCC) is disproportionally burdened by pathological remodeling like inflammation, fibrosis, and calcification. This has long been attributed to the resulting differences in hemodynamic load that arise from the presence, or lack thereof, of coronary ostia in respective sinuses. However, there is little to no empirical evidence to suggest that these differences in hemodynamic shear alone are enough to drive the difference in pathological remodeling that is observed. C57BL/6J mice exhibit a high variance in right coronary ostium (RCO) positioning with respect to the right coronary cusp (RCC). Through computational fluid dynamics (CFD) simulations of a mouse aortic valve (AoV) during end diastolic loading, we show negligible differences in wall shear stress (WSS) between a high RCO on the RCC and no ostium on the NCC. Also, though CFD analyses depict at least an order of magnitude difference in WSS through physiologically relevant ostia positions within the sinuses, ostium position does not correlate with calcification burden in a CKD mouse model of calcific AVD. Cusp dependent extracellular matrix (ECM) abundance analysis reveals asymmetric collagen and elastin content in healthy adult mice, but this does not follow the same trend as pathological remodeling. Instead, asymmetric abundance of elastin (P=0.034) and collagen (P=0.018) was mainly driven by an increase of these ECM proteins in the left coronary cusp (LCC) with no differences in leaflet thickness. Cusp dependent transcriptomic (spatial and bulk RNA sequencing) analyses reveal asymmetric phenotypic profiles between the three cusps in healthy adult mice. Of note, genes associated with vascular smooth muscle cell contraction and known modulators of AoV remodeling were upregulated in the NCC and downregulated in both the RCC and LCC. Together, these data suggest that the differences in shear resulting from the coronary ostia are not sufficient to explain the asymmetric onset of calcific AVD.
- 12 April 2025
- Published by Springer Nature
- p. 291-307
Revolutionizing Pediatric Valve Replacement: The Future of Elastin-Rich Tissue-Engineered Solutions
- 12 April 2025
- Published by Springer Nature
- p. 291-307
Revolutionizing Pediatric Valve Replacement: The Future of Elastin-Rich Tissue-Engineered Solutions
- Open Access
- 24 September 2024
- Published by MDPI AG in Bioengineering
- Vol. 11  (10) , 955
Computational Model for Early-Stage Aortic Valve Calcification Shows Hemodynamic Biomarkers
Heart disease is a leading cause of mortality, with calcific aortic valve disease (CAVD) being the most prevalent subset. Being able to predict this disease in its early stages is important for monitoring patients before they need aortic valve replacement surgery. Thus, this study explored hydrodynamic, mechanical, and hemodynamic differences in healthy and very mildly calcified porcine small intestinal submucosa (PSIS) bioscaffold valves to determine any notable parameters between groups that could, possibly, be used for disease tracking purposes. Three valve groups were tested: raw PSIS as a control and two calcified groups that were seeded with human valvular interstitial and endothelial cells (VICs/VECs) and cultivated in calcifying media. These two calcified groups were cultured in either static or bioreactor-induced oscillatory flow conditions. Hydrodynamic assessments showed metrics were below thresholds associated for even mild calcification. Young’s modulus, however, was significantly higher in calcified valves when compared to raw PSIS, indicating the morphological changes to the tissue structure. Fluid–structure interaction (FSI) simulations agreed well with hydrodynamic results and, most notably, showed a significant increase in time-averaged wall shear stress (TAWSS) between raw and calcified groups. We conclude that tracking hemodynamics may be a viable biomarker for early-stage CAVD tracking.
- 24 September 2024
- Published by MDPI AG in Bioengineering
- Vol. 11  (10) , 955
Open AccessComputational Model for Early-Stage Aortic Valve Calcification Shows Hemodynamic Biomarkers
Heart disease is a leading cause of mortality, with calcific aortic valve disease (CAVD) being the most prevalent subset. Being able to predict this disease in its early stages is important for monitoring patients before they need aortic valve replacement surgery. Thus, this study explored hydrodynamic, mechanical, and hemodynamic differences in healthy and very mildly calcified porcine small intestinal submucosa (PSIS) bioscaffold valves to determine any notable parameters between groups that could, possibly, be used for disease tracking purposes. Three valve groups were tested: raw PSIS as a control and two calcified groups that were seeded with human valvular interstitial and endothelial cells (VICs/VECs) and cultivated in calcifying media. These two calcified groups were cultured in either static or bioreactor-induced oscillatory flow conditions. Hydrodynamic assessments showed metrics were below thresholds associated for even mild calcification. Young’s modulus, however, was significantly higher in calcified valves when compared to raw PSIS, indicating the morphological changes to the tissue structure. Fluid–structure interaction (FSI) simulations agreed well with hydrodynamic results and, most notably, showed a significant increase in time-averaged wall shear stress (TAWSS) between raw and calcified groups. We conclude that tracking hemodynamics may be a viable biomarker for early-stage CAVD tracking.
- Open Access
- 13 June 2024
- Published by Elsevier in Materials Today Bio
- Vol. 27, 101121
A bypass flow model to study endothelial cell mechanotransduction across diverse flow environments
- 13 June 2024
- Published by Elsevier in Materials Today Bio
- Vol. 27, 101121
Open AccessA bypass flow model to study endothelial cell mechanotransduction across diverse flow environments
- Open Access
- 20 October 2022
- Published by MDPI AG in Bioengineering
- Vol. 9  (10) , 587
Stem Cell-Secreted Allogeneic Elastin-Rich Matrix with Subsequent Decellularization for the Treatment of Critical Valve Diseases in the Young
Critical valve diseases in infants have a very poor prognosis for survival. Particularly challenging is for the valve replacement to support somatic growth. From a valve regenerative standpoint, bio-scaffolds have been extensively investigated recently. While bio-scaffold valves facilitate acute valve functionality, their xenogeneic properties eventually induce a hostile immune response. Our goal was to investigate if a bio-scaffold valve could be deposited with tissues derived from allogeneic stem cells, with a specific dynamic culture protocol to enhance the extracellular matrix (ECM) constituents, with subsequent stem cell removal. Porcine small intestinal submucosa (PSIS) tubular-shaped bio-scaffold valves were seeded with human bone marrow-derived mesenchymal stem cells (hBMMSCs), cultured statically for 8 days, and then exposed to oscillatory fluid-induced shear stresses for two weeks. The valves were then safely decellularized to remove the hBMMSCs while retaining their secreted ECM. This de novo ECM was found to include significantly higher (p < 0.05) levels of elastin compared to the ECM produced by the hBMMSCs under standard rotisserie culture. The elastin-rich valves consisted of ~8% elastin compared to the ~10% elastin composition of native heart valves. Allogeneic elastin promotes chemotaxis thereby accelerating regeneration and can support somatic growth by rapidly integrating with the host following implantation. As a proof-of-concept of accelerated regeneration, we found that valve interstitial cells (VICs) secreted significantly more (p < 0.05) collagen on the elastin-rich matrix compared to the raw PSIS bio-scaffold.
- 20 October 2022
- Published by MDPI AG in Bioengineering
- Vol. 9  (10) , 587
Open AccessStem Cell-Secreted Allogeneic Elastin-Rich Matrix with Subsequent Decellularization for the Treatment of Critical Valve Diseases in the Young
Critical valve diseases in infants have a very poor prognosis for survival. Particularly challenging is for the valve replacement to support somatic growth. From a valve regenerative standpoint, bio-scaffolds have been extensively investigated recently. While bio-scaffold valves facilitate acute valve functionality, their xenogeneic properties eventually induce a hostile immune response. Our goal was to investigate if a bio-scaffold valve could be deposited with tissues derived from allogeneic stem cells, with a specific dynamic culture protocol to enhance the extracellular matrix (ECM) constituents, with subsequent stem cell removal. Porcine small intestinal submucosa (PSIS) tubular-shaped bio-scaffold valves were seeded with human bone marrow-derived mesenchymal stem cells (hBMMSCs), cultured statically for 8 days, and then exposed to oscillatory fluid-induced shear stresses for two weeks. The valves were then safely decellularized to remove the hBMMSCs while retaining their secreted ECM. This de novo ECM was found to include significantly higher (p < 0.05) levels of elastin compared to the ECM produced by the hBMMSCs under standard rotisserie culture. The elastin-rich valves consisted of ~8% elastin compared to the ~10% elastin composition of native heart valves. Allogeneic elastin promotes chemotaxis thereby accelerating regeneration and can support somatic growth by rapidly integrating with the host following implantation. As a proof-of-concept of accelerated regeneration, we found that valve interstitial cells (VICs) secreted significantly more (p < 0.05) collagen on the elastin-rich matrix compared to the raw PSIS bio-scaffold.
- Open Access
- 16 August 2022
- Published by MDPI AG in Bioengineering
- Vol. 9  (8) , 393
Valve Endothelial Cell Exposure to High Levels of Flow Oscillations Exacerbates Valve Interstitial Cell Calcification
The aortic valve facilitates unidirectional blood flow to the systemic circulation between the left cardiac ventricle and the aorta. The valve’s biomechanical function relies on thin leaflets to adequately open and close over the cardiac cycle. A monolayer of valve endothelial cells (VECs) resides on the outer surface of the aortic valve leaflet. Deeper within the leaflet are sublayers of valve interstitial cells (VICs). Valve tissue remodeling involves paracrine signaling between VECs and VICs. Aortic valve calcification can result from abnormal paracrine communication between these two cell types. VECs are known to respond to hemodynamic stimuli, and, specifically, flow abnormalities can induce VEC dysfunction. This dysfunction can subsequently change the phenotype of VICs, leading to aortic valve calcification. However, the relation between VEC-exposed flow oscillations under pulsatile flow to the progression of aortic valve calcification by VICs remains unknown. In this study, we quantified the level of flow oscillations that VECs were exposed to under dynamic culture and then immersed VICs in VEC-conditioned media. We found that VIC-induced calcification was augmented under maximum flow oscillations, wherein the flow was fully forward for half the cardiac cycle period and fully reversed for the other half. We were able to computationally correlate this finding to specific regions of the aortic valve that experience relatively high flow oscillations and that have been shown to be associated with severe calcified deposits. These findings establish a basis for future investigations on engineering calcified human valve tissues and its potential for therapeutic discovery of aortic valve calcification.
- 16 August 2022
- Published by MDPI AG in Bioengineering
- Vol. 9  (8) , 393
Open AccessValve Endothelial Cell Exposure to High Levels of Flow Oscillations Exacerbates Valve Interstitial Cell Calcification
The aortic valve facilitates unidirectional blood flow to the systemic circulation between the left cardiac ventricle and the aorta. The valve’s biomechanical function relies on thin leaflets to adequately open and close over the cardiac cycle. A monolayer of valve endothelial cells (VECs) resides on the outer surface of the aortic valve leaflet. Deeper within the leaflet are sublayers of valve interstitial cells (VICs). Valve tissue remodeling involves paracrine signaling between VECs and VICs. Aortic valve calcification can result from abnormal paracrine communication between these two cell types. VECs are known to respond to hemodynamic stimuli, and, specifically, flow abnormalities can induce VEC dysfunction. This dysfunction can subsequently change the phenotype of VICs, leading to aortic valve calcification. However, the relation between VEC-exposed flow oscillations under pulsatile flow to the progression of aortic valve calcification by VICs remains unknown. In this study, we quantified the level of flow oscillations that VECs were exposed to under dynamic culture and then immersed VICs in VEC-conditioned media. We found that VIC-induced calcification was augmented under maximum flow oscillations, wherein the flow was fully forward for half the cardiac cycle period and fully reversed for the other half. We were able to computationally correlate this finding to specific regions of the aortic valve that experience relatively high flow oscillations and that have been shown to be associated with severe calcified deposits. These findings establish a basis for future investigations on engineering calcified human valve tissues and its potential for therapeutic discovery of aortic valve calcification.
- 16 June 2022
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 144  (11)
Importance of Non-Newtonian Computational Fluid Modeling on Severely Calcified Aortic Valve Geometries—Insights From Quasi-Steady State Simulations
The Newtonian model has commonly been used to represent the viscosity of blood in the aorta, despite blood itself being a non-Newtonian fluid. This is justified where shear rates tend to be large. However, we hypothesized that using the Newtonian model to predict the hemodynamics on the aortic valve, particularly in those with severe calcifications, is inaccurate owing to valve leaflet geometry irregularities inducing multiple regions of low shear rates, 100 s-1, use of a Newtonian model was justified for the ventricularis side of the leaflet. However, in spatial regions of low shear rates, -1, specifically on the inner cusps of the fibrosa side of the valve, TAWSS calculations under a Newtonian model were found to be much lower when compared with their non-Newtonian Carreau and Quemada counterparts. We hereby conclude that in order to facilitate more accurate computational flow simulations in severe aortic valve calcification which is subjected to relatively large spatial regions of low shear (-1), a non-Newtonian model should be applied.
- 16 June 2022
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 144  (11)
Importance of Non-Newtonian Computational Fluid Modeling on Severely Calcified Aortic Valve Geometries—Insights From Quasi-Steady State Simulations
The Newtonian model has commonly been used to represent the viscosity of blood in the aorta, despite blood itself being a non-Newtonian fluid. This is justified where shear rates tend to be large. However, we hypothesized that using the Newtonian model to predict the hemodynamics on the aortic valve, particularly in those with severe calcifications, is inaccurate owing to valve leaflet geometry irregularities inducing multiple regions of low shear rates, 100 s-1, use of a Newtonian model was justified for the ventricularis side of the leaflet. However, in spatial regions of low shear rates, -1, specifically on the inner cusps of the fibrosa side of the valve, TAWSS calculations under a Newtonian model were found to be much lower when compared with their non-Newtonian Carreau and Quemada counterparts. We hereby conclude that in order to facilitate more accurate computational flow simulations in severe aortic valve calcification which is subjected to relatively large spatial regions of low shear (-1), a non-Newtonian model should be applied.
- Open Access
- 7 May 2019
- Published by MDPI AG in Bioengineering
- Vol. 6  (2) , 39
Elastin-Dependent Aortic Heart Valve Leaflet Curvature Changes During Cyclic Flexure
The progression of calcific aortic valve disease (CAVD) is characterized by extracellular matrix (ECM) remodeling, leading to structural abnormalities and improper valve function. The focus of the present study was to relate aortic valve leaflet axial curvature changes as a function of elastin degradation, which has been associated with CAVD. Circumferential rectangular strips (L Ă— W = 10 Ă— 2.5 mm) of normal and elastin-degraded (via enzymatic digestion) porcine AV leaflets were subjected to cyclic flexure (1 Hz). A significant increase in mean curvature (p < 0.05) was found in elastin-degraded leaflet specimens in comparison to un-degraded controls at both the semi-constrained (50% of maximum flexed state during specimen bending and straightening events) and fully-constrained (maximally-flexed) states. This significance did not occur in all three flexed configurations when measurements were performed using either minimum or maximum curvature. Moreover, the mean curvature increase in the elastin-degraded leaflets was most pronounced at the instance of maximum flexure, compared to un-degraded controls. We conclude that the mean axial curvature metric can detect distinct spatial changes in aortic valve ECM arising from the loss in bulk content and/or structure of elastin, particularly when there is a high degree of tissue bending. Therefore, the instance of maximum leaflet flexure during the cardiac cycle could be targeted for mean curvature measurements and serve as a potential biomarker for elastin degradation in early CAVD remodeling.
- 7 May 2019
- Published by MDPI AG in Bioengineering
- Vol. 6  (2) , 39
Open AccessElastin-Dependent Aortic Heart Valve Leaflet Curvature Changes During Cyclic Flexure
The progression of calcific aortic valve disease (CAVD) is characterized by extracellular matrix (ECM) remodeling, leading to structural abnormalities and improper valve function. The focus of the present study was to relate aortic valve leaflet axial curvature changes as a function of elastin degradation, which has been associated with CAVD. Circumferential rectangular strips (L Ă— W = 10 Ă— 2.5 mm) of normal and elastin-degraded (via enzymatic digestion) porcine AV leaflets were subjected to cyclic flexure (1 Hz). A significant increase in mean curvature (p < 0.05) was found in elastin-degraded leaflet specimens in comparison to un-degraded controls at both the semi-constrained (50% of maximum flexed state during specimen bending and straightening events) and fully-constrained (maximally-flexed) states. This significance did not occur in all three flexed configurations when measurements were performed using either minimum or maximum curvature. Moreover, the mean curvature increase in the elastin-degraded leaflets was most pronounced at the instance of maximum flexure, compared to un-degraded controls. We conclude that the mean axial curvature metric can detect distinct spatial changes in aortic valve ECM arising from the loss in bulk content and/or structure of elastin, particularly when there is a high degree of tissue bending. Therefore, the instance of maximum leaflet flexure during the cardiac cycle could be targeted for mean curvature measurements and serve as a potential biomarker for elastin degradation in early CAVD remodeling.