SSSeung-Chul Shin

Seung-Chul Shin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Seung-Chul Shin has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Wearable-Based Integrated System for In-Home Monitoring and Analysis of Nocturnal Enuresis

    by Sangyeop Lee, Junhyung Moon, Yong Seung Lee, Seung-Chul Shin, Kyoungwoo Lee

    Nocturnal enuresis (NE) is involuntary bedwetting during sleep, typically appearing in young children. Despite the potential benefits of the long-term home monitoring of NE patients for research and treatment enhancement, this area remains underexplored. To address this, we propose NEcare, an in-home monitoring system that utilizes wearable devices and machine learning techniques. NEcare collects sensor data from an electrocardiogram, body impedance (BI), a three-axis accelerometer, and a three-axis gyroscope to examine bladder volume (BV), heart rate (HR), and periodic limb movements in sleep (PLMS). Additionally, it analyzes the collected NE patient data and supports NE moment estimation using heuristic rules and deep learning techniques. To demonstrate the feasibility of in-home monitoring for NE patients using our wearable system, we used our datasets from 30 in-hospital patients and 4 in-home patients. The results show that NEcare captures expected trends associated with NE occurrences, including BV increase, HR increase, and PLMS appearance. In addition, we studied the machine learning-based NE moment estimation, which could help relieve the burdens of NE patients and their families. Finally, we address the limitations and outline future research directions for the development of wearable systems for NE patients


  • Continuous body impedance measurement to detect bladder volume changes during urodynamic study: A prospective study in pediatric patients

    by Sangyeop Lee, Junhyung Moon, Seung‐Chul Shin, Ji Hye Hwang, Kyoungwoo Lee, Yong Seung Lee

    Aims: To assess the possibility of the body impedance (BI) reflecting bladder volumes (BV) in pediatric patients, the BI signals are measured continuously with the equipment that we have developed and reported previously, during the filling phase of urodynamic study (UDS).Methods: A total of 30 children (5–12 years old) are included in this prospective study. The equipment uses two dry electrodes embedded inside a strap to collect impedance and electrocardiogram signals. The factors affecting baseline BI and its decreases during UDS have been investigated.Results: The median age is 6.1 years and BI is accurately measured in 27 out of 30 patients (90.0% accuracy). The median value of baseline BI is 1958 Ω. It is higher when they are older, equal to or taller than 125 cm, or non‐neurogenic bladder patients. BI decreases as the bladder is filled with saline in 21 patients (77.8%), and remains constant in 6 patients (22.2%). The median age of the Decreased Group is significantly higher than that of Nondecreased Group (p = .036). Height of 125 cm or more is significant in the Decreased Group (p = .020). Heart rates also have been simultaneously measured and revealed a mild decrease during the filling phase.Conclusions: The baseline BI is affected by the height and age of the children. BI is effectively measured and reflects a change in the BV in older children who are taller than 125 cm, with a small device using a smartphone and a strap.


  • Open Access

    Dry Electrode-Based Body Fat Estimation System with Anthropometric Data for Use in a Wearable Device

    by Seung-Chul Shin, Jinkyu Lee, Soyeon Choe, Hyuk In Yang, Jihee Min, Ki-Yong Ahn, Justin Y. Jeon, Hong-Goo Kang

    The bioelectrical impedance analysis (BIA) method is widely used to predict percent body fat (PBF). However, it requires four to eight electrodes, and it takes a few minutes to accurately obtain the measurement results. In this study, we propose a faster and more accurate method that utilizes a small dry electrode-based wearable device, which predicts whole-body impedance using only upper-body impedance values. Such a small electrode-based device typically needs a long measurement time due to increased parasitic resistance, and its accuracy varies by measurement posture. To minimize these variations, we designed a sensing system that only utilizes contact with the wrist and index fingers. The measurement time was also reduced to five seconds by an effective parameter calibration network. Finally, we implemented a deep neural network-based algorithm to predict the PBF value by the measurement of the upper-body impedance and lower-body anthropometric data as auxiliary input features. The experiments were performed with 163 amateur athletes who exercised regularly. The performance of the proposed system was compared with those of two commercial systems that were designed to measure body composition using either a whole-body or upper-body impedance value. The results showed that the correlation coefficient ( r 2 ) value was improved by about 9%, and the standard error of estimate (SEE) was reduced by 28%.


  • Continuous bladder volume monitoring system for wearable applications

    by Seung-Chul Shin, Junhyung Moon, Saewon Kye, Kyoungwoo Lee, Yong Seung Lee, Hong-Goo Kang

    In this research, we propose a bladder volume monitoring system that can be effectively applied for various voiding dysfunctions. Whereas conventional systems lack consecutive measurements, the proposed system can continuously monitor a user's status even during unconscious sleep. For the convenience, we design a simple and comfortable waist-belt-type device by using the body impedance analysis (BIA) technique. To support various measurement scenarios, we develop applications by connecting the device to a smartphone. To minimize motion noises, which are inevitable when monitoring over an extended period, we propose a motion artifact reduction algorithm that exploits multiple frequency sources. The experimental results show a strong relationship between the impedance variation and the bladder volume; this confirms the feasibility of our system.