Felix Henningsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Felix Henningsen has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
A. Gärtner
Physik-Department, Technische Universität München, James-Franck-Str 1, D-85748 Garching, Germany
3 shared publicationsC. Spannfellner
Physik-Department, Technische Universität München, James-Franck-Str 1, D-85748 Garching, Germany
3 shared publicationsK. Holzapfel
Physik-Department, Technische Universität München, James-Franck-Str 1, D-85748 Garching, Germany
3 shared publicationsL. Papp
Physik-Department, Technische Universität München, James-Franck-Str 1, D-85748 Garching, Germany
3 shared publicationsM. Boehmer
Physik-Department, Technische Universität München, James-Franck-Str 1, D-85748 Garching, Germany
3 shared publicationsM. Traxler
GSI Helmholtz Centre for Heavy Ion Research GmbH, Planckstr 1, D-64291 Darmstadt, Germany
3 shared publications
Latest Publications
- 1 September 2021
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 16 (09) , C09033
A self-monitoring precision calibration light source for the IceCube Upgrade
- 1 September 2021
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 16 (09) , C09033
A self-monitoring precision calibration light source for the IceCube Upgrade
- Open Access
A self-monitoring precision calibration light source for large-volume neutrino telescopes
With the rise of neutrino astronomy using large-volume detector arrays, calibration improvements of optical media and photosensors have emerged as significant means to reduce detector systematics. To improve understanding of the detector volume and its instrumentation, we developed an absolutely-calibrated, self-monitoring, isotropic, nanosecond, high-intensity calibration light source called "Precision Optical Calibration Module" (POCAM). This now third iteration of the instrument was developed for an application in the IceCube Upgrade but, with a modular instrument communications and synchronization backend, can provide a calibration light source standard for any large-volume photodetector array. This work summarizes the functional principle of the POCAM and all related device characteristics as well as its precision calibration procedure. The latter provides fingerprint-characterized instruments with knowledge on absolute and relative behavior of the emitted light pulses as well as their temperature dependencies.
Open AccessA self-monitoring precision calibration light source for large-volume neutrino telescopes
With the rise of neutrino astronomy using large-volume detector arrays, calibration improvements of optical media and photosensors have emerged as significant means to reduce detector systematics. To improve understanding of the detector volume and its instrumentation, we developed an absolutely-calibrated, self-monitoring, isotropic, nanosecond, high-intensity calibration light source called "Precision Optical Calibration Module" (POCAM). This now third iteration of the instrument was developed for an application in the IceCube Upgrade but, with a modular instrument communications and synchronization backend, can provide a calibration light source standard for any large-volume photodetector array. This work summarizes the functional principle of the POCAM and all related device characteristics as well as its precision calibration procedure. The latter provides fingerprint-characterized instruments with knowledge on absolute and relative behavior of the emitted light pulses as well as their temperature dependencies.
- Open Access
The POCAM as self-calibrating light source for the IceCube Upgrade
The planned IceCube Upgrade, consisting of seven new instrumentation strings, will be installed at the South Pole within 2022/2023. The focus of this upgrade is calibration, reduction of systematic uncertainties and atmospheric neutrino physics. Within this scope, the "Precision Optical Calibration Module" (POCAM) will be installed at a number of positions on these new strings, to act as a calibration light source. The POCAM is an in-situ self-calibrating, isotropic, nanosecond light source that emits flashes of adjustable intensity and pulse duration. The isotropy is achieved using a teflon integrating sphere which further allows the calibration of the total number of emitted photons per pulse, using the integrated sensors. Prototypes have been deployed and operated within the GVD telescope in Lake Baikal and within the STRAW experiment in the Pacific Ocean. We present POCAM results and experiences from the GVD and STRAW installations as well as first IceCube sensitivity studies and the following design prospects for this next-generation POCAM iteration.
Open AccessThe POCAM as self-calibrating light source for the IceCube Upgrade
The planned IceCube Upgrade, consisting of seven new instrumentation strings, will be installed at the South Pole within 2022/2023. The focus of this upgrade is calibration, reduction of systematic uncertainties and atmospheric neutrino physics. Within this scope, the "Precision Optical Calibration Module" (POCAM) will be installed at a number of positions on these new strings, to act as a calibration light source. The POCAM is an in-situ self-calibrating, isotropic, nanosecond light source that emits flashes of adjustable intensity and pulse duration. The isotropy is achieved using a teflon integrating sphere which further allows the calibration of the total number of emitted photons per pulse, using the integrated sensors. Prototypes have been deployed and operated within the GVD telescope in Lake Baikal and within the STRAW experiment in the Pacific Ocean. We present POCAM results and experiences from the GVD and STRAW installations as well as first IceCube sensitivity studies and the following design prospects for this next-generation POCAM iteration.
- Open Access
- 10 May 2019
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 207, 06006
STRAW (STRings for Absorption length in Water): pathfinder for a neutrino telescope in the deep Pacific Ocean
Recently, an opportunity for a pathfinder mission towards a new neutrino telescope appeared in the Pacific Ocean. An existing deep-sea electrooptical infrastructure maintained by Ocean Networks Canada could pose as the base towards a potential new large-volume neutrino telescope. Two groups from Technical University Munich and the University of Alberta pursued the optical characterization of the 2.6 km deep site calledCascada Basinwithin the scope of the “Strings for Absorption length in Water” (STRAW) project. We present a summary of the 1-year construction timeline, impressions of the detector performance and first results.
- 10 May 2019
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 207, 06006
Open AccessSTRAW (STRings for Absorption length in Water): pathfinder for a neutrino telescope in the deep Pacific Ocean
Recently, an opportunity for a pathfinder mission towards a new neutrino telescope appeared in the Pacific Ocean. An existing deep-sea electrooptical infrastructure maintained by Ocean Networks Canada could pose as the base towards a potential new large-volume neutrino telescope. Two groups from Technical University Munich and the University of Alberta pursued the optical characterization of the 2.6 km deep site calledCascada Basinwithin the scope of the “Strings for Absorption length in Water” (STRAW) project. We present a summary of the 1-year construction timeline, impressions of the detector performance and first results.
- Open Access
STRAW (STRings for Absorption length in Water): pathfinder for a neutrino telescope in the deep Pacific Ocean
We report about the design and the initial performances of the pathfinder mission for a possible large scale neutrino telescope named "STRings for Absorption length in Water" (STRAW). In June 2018 STRAW has been deployed at the Cascadia Basin site operated by Ocean Network Canada and has been collecting data since then. At a depth of about 2600 meters, the two STRAW 120 meters tall mooring lines are instrumented by three "Precision Optical Calibration Modules" (POCAM) and five Digital Optical Sensors (sDOM). We describe the instrumentation deployed and first light in the Pacific Ocean.
Open AccessSTRAW (STRings for Absorption length in Water): pathfinder for a neutrino telescope in the deep Pacific Ocean
We report about the design and the initial performances of the pathfinder mission for a possible large scale neutrino telescope named "STRings for Absorption length in Water" (STRAW). In June 2018 STRAW has been deployed at the Cascadia Basin site operated by Ocean Network Canada and has been collecting data since then. At a depth of about 2600 meters, the two STRAW 120 meters tall mooring lines are instrumented by three "Precision Optical Calibration Modules" (POCAM) and five Digital Optical Sensors (sDOM). We describe the instrumentation deployed and first light in the Pacific Ocean.