Rui Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rui Zheng has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Mingzhai Sun
School of Biomedical Engineering Division of Life Sciences and Medicine University of Science and Technology of China Hefei Anhui China
3 shared publications Shulin Zhang
Department of Precision Machinery and Instrumentation, University of Science and Technology of China, Hefei, China
2 shared publicationsBin Li
Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, Anhui 230022, China
1 shared publicationBo Li
School of Earth and Space Science, University of Science and Technology of China, Hefei, China
1 shared publication- Cheng Liu
Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, 230026, China
1 shared publication Chun Zheng
The 105 Hospital of PLA, Hefei, Anhui 230031, China
1 shared publication
Latest Publications
- Open Access
- 22 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 60 (01962892) , 1-13
Prediction of Vertical Profile of NO₂ Using Deep Multimodal Fusion Network Based on the Ground-Based 3-D Remote Sensing
The vertical distribution profiles of NO 2 are essential for understanding the mechanisms, detecting near-surface emissions, and tracking pollutant transportation at high altitude. However, most of the published NO 2 studies are based on the surface 2-D measurements. The ground-based 3-D remote-sensing stations were recently built to measure vertical distribution profiles of NO 2 . However, the stations were spatially sparse due to the high cost and could not make the measurements without sunlight. In this study, we first developed a multimodel fusion network (MF-net) based on the sparse vertical observations from the Jing-Jin-Ji region. We achieved the 3-D profile prediction of NO 2 in the range of 39.005–41.405N and 115.005–117.905E with 24-h coverage. The MF-net significantly surpassed the conventional WRF-CHEM model and provided a more accurate evaluation of the NO 2 transmission between Beijing and the neighboring cities. Besides, the MF-net covers the monitoring of NO 2 to the whole study area and extends the monitoring time to the entire day (24 h), making it serviceable for continuous spatial-temporal estimation of NO 2 and its transmission in pollution events. The MF-net provides more robust data support to formulate reasonable and effective pollution prevention and control measures.
- 22 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 60 (01962892) , 1-13
Open AccessPrediction of Vertical Profile of NO₂ Using Deep Multimodal Fusion Network Based on the Ground-Based 3-D Remote Sensing
The vertical distribution profiles of NO 2 are essential for understanding the mechanisms, detecting near-surface emissions, and tracking pollutant transportation at high altitude. However, most of the published NO 2 studies are based on the surface 2-D measurements. The ground-based 3-D remote-sensing stations were recently built to measure vertical distribution profiles of NO 2 . However, the stations were spatially sparse due to the high cost and could not make the measurements without sunlight. In this study, we first developed a multimodel fusion network (MF-net) based on the sparse vertical observations from the Jing-Jin-Ji region. We achieved the 3-D profile prediction of NO 2 in the range of 39.005–41.405N and 115.005–117.905E with 24-h coverage. The MF-net significantly surpassed the conventional WRF-CHEM model and provided a more accurate evaluation of the NO 2 transmission between Beijing and the neighboring cities. Besides, the MF-net covers the monitoring of NO 2 to the whole study area and extends the monitoring time to the entire day (24 h), making it serviceable for continuous spatial-temporal estimation of NO 2 and its transmission in pollution events. The MF-net provides more robust data support to formulate reasonable and effective pollution prevention and control measures.
- Open Access
- 1 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 57561-57573
Simultaneous Arteriole and Venule Segmentation of Dual-Modal Fundus Images Using a Multi-Task Cascade Network
Differentiating arterioles and venules in the fundus image is important for not only various eye diseases but also systemic diseases such as hypertension and ischemic stroke. In this study, we use dual-modal fundus images and develop a cascade refined U-net (CRU-net) to improve the arteriovenous segmentation. Dual-modal fundus images include not only a regular color fundus image (RGB image) but also another two monochromic images acquired using two different wavelengths, 570 nm and 610 nm in our study. The choice of these two wavelengths is based on the absorption spectra of hemoglobin. The two monochromic images provide much richer information on the arteriole and venule. Our proposed CRU-net can fully utilize the information and achieves the state-of-the-art performance on our dual-modal dataset (DualModal2019). The arteriovenous classification accuracy evaluated on the automatically detected vessels is 97.27%, significantly surpassed previous methods. The F1-scores are 77.69% and 79.53% for the arteriole and venule segmentation, respectively. We also test our CRU-net on the public DRIVE dataset with only the color fundus images. We achieve the accuracy of 93.97%, and F1-scores of 73.50% and 75.54% for the arteriole and venule, all of which significantly surpassed previously published methods. Our DualModal2019 dataset with manually annotated arterioles and venules is publicly available.
- 1 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 57561-57573
Open AccessSimultaneous Arteriole and Venule Segmentation of Dual-Modal Fundus Images Using a Multi-Task Cascade Network
Differentiating arterioles and venules in the fundus image is important for not only various eye diseases but also systemic diseases such as hypertension and ischemic stroke. In this study, we use dual-modal fundus images and develop a cascade refined U-net (CRU-net) to improve the arteriovenous segmentation. Dual-modal fundus images include not only a regular color fundus image (RGB image) but also another two monochromic images acquired using two different wavelengths, 570 nm and 610 nm in our study. The choice of these two wavelengths is based on the absorption spectra of hemoglobin. The two monochromic images provide much richer information on the arteriole and venule. Our proposed CRU-net can fully utilize the information and achieves the state-of-the-art performance on our dual-modal dataset (DualModal2019). The arteriovenous classification accuracy evaluated on the automatically detected vessels is 97.27%, significantly surpassed previous methods. The F1-scores are 77.69% and 79.53% for the arteriole and venule segmentation, respectively. We also test our CRU-net on the public DRIVE dataset with only the color fundus images. We achieve the accuracy of 93.97%, and F1-scores of 73.50% and 75.54% for the arteriole and venule, all of which significantly surpassed previously published methods. Our DualModal2019 dataset with manually annotated arterioles and venules is publicly available.
- 14 September 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (10) , 4863-4878
Detection of exudates in fundus photographs with imbalanced learning using conditional generative adversarial network
Diabetic retinopathy (DR) is a leading cause of blindness worldwide. However, 90% of DR caused blindness can be prevented if diagnosed and intervened early. Retinal exudates can be observed at the early stage of DR and can be used as signs for early DR diagnosis. Deep convolutional neural networks (DCNNs) have been applied for exudate detection with promising results. However, there exist two main challenges when applying the DCNN based methods for exudate detection. One is the very limited number of labeled data available from medical experts, and another is the severely imbalanced distribution of data of different classes. First, there are many more images of normal eyes than those of eyes with exudates, particularly for screening datasets. Second, the number of normal pixels (non-exudates) is much greater than the number of abnormal pixels (exudates) in images containing exudates. To tackle the small sample set problem, an ensemble convolutional neural network (MU-net) based on a U-net structure is presented in this paper. To alleviate the imbalance data problem, the conditional generative adversarial network (cGAN) is adopted to generate label-preserving minority class data specifically to implement the data augmentation. The network was trained on one dataset (e_ophtha_EX) and tested on the other three public datasets (DiaReTDB1, HEI-MED and MESSIDOR). CGAN, as a data augmentation method, significantly improves network robustness and generalization properties, achieving F1-scores of 92.79%, 92.46%, 91.27%, and 94.34%, respectively, as measured at the lesion level. While without cGAN, the corresponding F1-scores were 92.66%, 91.41%, 90.72%, and 90.58%, respectively. When measured at the image level, with cGAN we achieved the accuracy of 95.45%, 92.13%, 88.76%, and 89.58%, compared with the values achieved without cGAN of 86.36%, 87.64%, 76.33%, and 86.42%, respectively.
- 14 September 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (10) , 4863-4878
Detection of exudates in fundus photographs with imbalanced learning using conditional generative adversarial network
Diabetic retinopathy (DR) is a leading cause of blindness worldwide. However, 90% of DR caused blindness can be prevented if diagnosed and intervened early. Retinal exudates can be observed at the early stage of DR and can be used as signs for early DR diagnosis. Deep convolutional neural networks (DCNNs) have been applied for exudate detection with promising results. However, there exist two main challenges when applying the DCNN based methods for exudate detection. One is the very limited number of labeled data available from medical experts, and another is the severely imbalanced distribution of data of different classes. First, there are many more images of normal eyes than those of eyes with exudates, particularly for screening datasets. Second, the number of normal pixels (non-exudates) is much greater than the number of abnormal pixels (exudates) in images containing exudates. To tackle the small sample set problem, an ensemble convolutional neural network (MU-net) based on a U-net structure is presented in this paper. To alleviate the imbalance data problem, the conditional generative adversarial network (cGAN) is adopted to generate label-preserving minority class data specifically to implement the data augmentation. The network was trained on one dataset (e_ophtha_EX) and tested on the other three public datasets (DiaReTDB1, HEI-MED and MESSIDOR). CGAN, as a data augmentation method, significantly improves network robustness and generalization properties, achieving F1-scores of 92.79%, 92.46%, 91.27%, and 94.34%, respectively, as measured at the lesion level. While without cGAN, the corresponding F1-scores were 92.66%, 91.41%, 90.72%, and 90.58%, respectively. When measured at the image level, with cGAN we achieved the accuracy of 95.45%, 92.13%, 88.76%, and 89.58%, compared with the values achieved without cGAN of 86.36%, 87.64%, 76.33%, and 86.42%, respectively.