Leia C. Shum
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Leia C. Shum has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Iaboni
KITE Research Institute, University Health Network
5 shared publications - Alisa Grigorovich
Brock University
3 shared publications - Bulmaro Adolfo Valdés
Menrva Research Group, Schools of Mechatronic Systems and Engineering Science, Simon Fraser University, 250-13450 102nd Avenue, Surrey, BC V5A 1S6, Canada
3 shared publications - Hendrik F. Machiel Van der Loos
Mechanical Engineering, University of British Columbia, Vancouver, British Columbia, CANADA
3 shared publications - Josephine McMurray
Lazaridis School of Business & Economics/Community Health, Wilfrid Laurier University, Waterloo, ON, Canada
3 shared publications - Lynn Haslam-Larmer
KITE Research Institute, Toronto Rehabilitation Institute, University Health Network , Toronto, Ontario
3 shared publications
Latest Publications
- Open Access
- 10 November 2025
- Published by Oxford University Press (OUP) in The Gerontologist
- Vol. 65 (12)
Real-time location system implementation in dementia care: Stakeholder perspectives
Background and Objectives: Despite interest in using real-time location systems (RTLS) to improve quality and efficiency of care and to collect data for the development of clinical algorithms, research on their implementation and use in long-term care homes is scarce. This study examines RTLS implementation in one long-term care home identifying failure points, ethical tensions, and sociotechnical misalignments that led to abandonment. Research Design and Methods: Semistructured interviews were conducted with 47 participants (residents, care partners, direct care staff, managers, administrators) across two time points; all also completed a demographic survey. Thematic analysis of the data was guided by the Non-Adoption, Abandonment, Scale-up, Spread and Sustainability framework, and Sociotechnical Systems theory. Results: Initial enthusiasm for RTLS stemmed from safety and efficiency expectations, but misaligned functionalities, limited staff engagement, and ethical tensions undermined adoption. Stakeholders anticipated real-time monitoring and fall detection, neither of which were provided. Residents frequently removed the wearables, citing discomfort and privacy, while staff encountered barriers due to the limited integration of the RTLS into workflows. Ethical tensions emerged as residents’ autonomy and preferences were overridden by care partners. Discussion and Implications: These failures underscore the need for iterative and participatory approaches to implementation, transparent communication, and stakeholder alignment. The findings highlight the sociotechnical complexities of implementing surveillance technologies in long-term care. Ethical concerns surrounding resident autonomy, workforce surveillance, and data governance, must be addressed in future implementations to ensure that RTLS supports rather than compromises the dignity and rights of residents and staff.
- 10 November 2025
- Published by Oxford University Press (OUP) in The Gerontologist
- Vol. 65 (12)
Open AccessReal-time location system implementation in dementia care: Stakeholder perspectives
Background and Objectives: Despite interest in using real-time location systems (RTLS) to improve quality and efficiency of care and to collect data for the development of clinical algorithms, research on their implementation and use in long-term care homes is scarce. This study examines RTLS implementation in one long-term care home identifying failure points, ethical tensions, and sociotechnical misalignments that led to abandonment. Research Design and Methods: Semistructured interviews were conducted with 47 participants (residents, care partners, direct care staff, managers, administrators) across two time points; all also completed a demographic survey. Thematic analysis of the data was guided by the Non-Adoption, Abandonment, Scale-up, Spread and Sustainability framework, and Sociotechnical Systems theory. Results: Initial enthusiasm for RTLS stemmed from safety and efficiency expectations, but misaligned functionalities, limited staff engagement, and ethical tensions undermined adoption. Stakeholders anticipated real-time monitoring and fall detection, neither of which were provided. Residents frequently removed the wearables, citing discomfort and privacy, while staff encountered barriers due to the limited integration of the RTLS into workflows. Ethical tensions emerged as residents’ autonomy and preferences were overridden by care partners. Discussion and Implications: These failures underscore the need for iterative and participatory approaches to implementation, transparent communication, and stakeholder alignment. The findings highlight the sociotechnical complexities of implementing surveillance technologies in long-term care. Ethical concerns surrounding resident autonomy, workforce surveillance, and data governance, must be addressed in future implementations to ensure that RTLS supports rather than compromises the dignity and rights of residents and staff.
- Open Access
- 8 April 2024
- Published by JMIR Publications Inc. in JMIR Aging
- Vol. 7 (1) , e45978
Factors That Influence Successful Adoption of Real-Time Location Systems for Use in a Dementia Care Setting: Mixed Methods Study
Background: Technology has been identified as a potential solution to alleviate resource gaps and augment care delivery in dementia care settings such as hospitals, long-term care, and retirement homes. There has been an increasing interest in using real-time location systems (RTLS) across health care settings for older adults with dementia, specifically related to the ability to track a person’s movement and location. Objective: In this study, we aimed to explore the factors that influence the adoption or nonadoption of an RTLS during its implementation in a specialized inpatient dementia unit in a tertiary care rehabilitation hospital. Methods: The study included data from a brief quantitative survey and interviews from a convenience sample of frontline participants. Our deductive analysis of the interview used the 3 categories of the Fit Between Individuals, Task, and Technology framework as follows: individual and task, individual and technology, and task and technology. The purpose of using this framework was to assess the quality of the fit between technology attributes and an individual’s self-reported intentions to adopt RTLS technology. Results: A total of 20 health care providers (HCPs) completed the survey, of which 16 (80%) participated in interviews. Coding and subsequent analysis identified 2 conceptual subthemes in the individual-task fit category, including the identification of the task and the perception that participants were missing at-risk patient events. The task-technology fit category consisted of 3 subthemes, including reorganization of the task, personal control in relation to the task, and efficiency or resource allocation. A total of 4 subthemes were identified in the individual-technology fit category, including privacy and personal agency, trust in the technology, user interfaces, and perceptions of increased safety. Conclusions: By the end of the study, most of the unit’s HCPs were using the tablet app based on their perception of its usefulness, its alignment with their comfort level with technology, and its ability to help them perform job responsibilities. HCPs perceived that they were able to reduce patient search time dramatically, yet any improvements in care were noted to be implied, as this was not measured. There was limited anecdotal evidence of reduced patient risk or adverse events, but greater reported peace of mind for HCPs overseeing patients’ activity levels.
- 8 April 2024
- Published by JMIR Publications Inc. in JMIR Aging
- Vol. 7 (1) , e45978
Open AccessFactors That Influence Successful Adoption of Real-Time Location Systems for Use in a Dementia Care Setting: Mixed Methods Study
Background: Technology has been identified as a potential solution to alleviate resource gaps and augment care delivery in dementia care settings such as hospitals, long-term care, and retirement homes. There has been an increasing interest in using real-time location systems (RTLS) across health care settings for older adults with dementia, specifically related to the ability to track a person’s movement and location. Objective: In this study, we aimed to explore the factors that influence the adoption or nonadoption of an RTLS during its implementation in a specialized inpatient dementia unit in a tertiary care rehabilitation hospital. Methods: The study included data from a brief quantitative survey and interviews from a convenience sample of frontline participants. Our deductive analysis of the interview used the 3 categories of the Fit Between Individuals, Task, and Technology framework as follows: individual and task, individual and technology, and task and technology. The purpose of using this framework was to assess the quality of the fit between technology attributes and an individual’s self-reported intentions to adopt RTLS technology. Results: A total of 20 health care providers (HCPs) completed the survey, of which 16 (80%) participated in interviews. Coding and subsequent analysis identified 2 conceptual subthemes in the individual-task fit category, including the identification of the task and the perception that participants were missing at-risk patient events. The task-technology fit category consisted of 3 subthemes, including reorganization of the task, personal control in relation to the task, and efficiency or resource allocation. A total of 4 subthemes were identified in the individual-technology fit category, including privacy and personal agency, trust in the technology, user interfaces, and perceptions of increased safety. Conclusions: By the end of the study, most of the unit’s HCPs were using the tablet app based on their perception of its usefulness, its alignment with their comfort level with technology, and its ability to help them perform job responsibilities. HCPs perceived that they were able to reduce patient search time dramatically, yet any improvements in care were noted to be implied, as this was not measured. There was limited anecdotal evidence of reduced patient risk or adverse events, but greater reported peace of mind for HCPs overseeing patients’ activity levels.
- 9 September 2023
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 144, 102657
Walking path images from real-time location data predict degree of cognitive impairment
- 9 September 2023
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 144, 102657
Walking path images from real-time location data predict degree of cognitive impairment
- Open Access
- 24 January 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Factors That Influence Successful Adoption of Real-Time Location Systems for Use in a Dementia Care Setting: Mixed Methods Study (Preprint)
BACKGROUND Technology has been identified as a potential solution to alleviate resource gaps and augment care delivery in dementia care settings such as hospitals, long-term care, and retirement homes. There has been an increasing interest in using real-time location systems (RTLS) across health care settings for older adults with dementia, specifically related to the ability to track a person’s movement and location. OBJECTIVE In this study, we aimed to explore the factors that influence the adoption or nonadoption of an RTLS during its implementation in a specialized inpatient dementia unit in a tertiary care rehabilitation hospital. METHODS The study included data from a brief quantitative survey and interviews from a convenience sample of frontline participants. Our deductive analysis of the interview used the 3 categories of the Fit Between Individuals, Task, and Technology framework as follows: individual and task, individual and technology, and task and technology. The purpose of using this framework was to assess the quality of the fit between technology attributes and an individual’s self-reported intentions to adopt RTLS technology. RESULTS A total of 20 health care providers (HCPs) completed the survey, of which 16 (80%) participated in interviews. Coding and subsequent analysis identified 2 conceptual subthemes in the individual-task fit category, including the identification of the task and the perception that participants were missing at-risk patient events. The task-technology fit category consisted of 3 subthemes, including reorganization of the task, personal control in relation to the task, and efficiency or resource allocation. A total of 4 subthemes were identified in the individual-technology fit category, including privacy and personal agency, trust in the technology, user interfaces, and perceptions of increased safety. CONCLUSIONS By the end of the study, most of the unit’s HCPs were using the tablet app based on their perception of its usefulness, its alignment with their comfort level with technology, and its ability to help them perform job responsibilities. HCPs perceived that they were able to reduce patient search time dramatically, yet any improvements in care were noted to be implied, as this was not measured. There was limited anecdotal evidence of reduced patient risk or adverse events, but greater reported peace of mind for HCPs overseeing patients’ activity levels.
- 24 January 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessFactors That Influence Successful Adoption of Real-Time Location Systems for Use in a Dementia Care Setting: Mixed Methods Study (Preprint)
BACKGROUND Technology has been identified as a potential solution to alleviate resource gaps and augment care delivery in dementia care settings such as hospitals, long-term care, and retirement homes. There has been an increasing interest in using real-time location systems (RTLS) across health care settings for older adults with dementia, specifically related to the ability to track a person’s movement and location. OBJECTIVE In this study, we aimed to explore the factors that influence the adoption or nonadoption of an RTLS during its implementation in a specialized inpatient dementia unit in a tertiary care rehabilitation hospital. METHODS The study included data from a brief quantitative survey and interviews from a convenience sample of frontline participants. Our deductive analysis of the interview used the 3 categories of the Fit Between Individuals, Task, and Technology framework as follows: individual and task, individual and technology, and task and technology. The purpose of using this framework was to assess the quality of the fit between technology attributes and an individual’s self-reported intentions to adopt RTLS technology. RESULTS A total of 20 health care providers (HCPs) completed the survey, of which 16 (80%) participated in interviews. Coding and subsequent analysis identified 2 conceptual subthemes in the individual-task fit category, including the identification of the task and the perception that participants were missing at-risk patient events. The task-technology fit category consisted of 3 subthemes, including reorganization of the task, personal control in relation to the task, and efficiency or resource allocation. A total of 4 subthemes were identified in the individual-technology fit category, including privacy and personal agency, trust in the technology, user interfaces, and perceptions of increased safety. CONCLUSIONS By the end of the study, most of the unit’s HCPs were using the tablet app based on their perception of its usefulness, its alignment with their comfort level with technology, and its ability to help them perform job responsibilities. HCPs perceived that they were able to reduce patient search time dramatically, yet any improvements in care were noted to be implied, as this was not measured. There was limited anecdotal evidence of reduced patient risk or adverse events, but greater reported peace of mind for HCPs overseeing patients’ activity levels.
- Open Access
Indoor Location Data for Tracking Human Behaviours: A Scoping Review
Real-time location systems (RTLS) record locations of individuals over time and are valuable sources of spatiotemporal data that can be used to understand patterns of human behaviour. Location data are used in a wide breadth of applications, from locating individuals to contact tracing or monitoring health markers. To support the use of RTLS in many applications, the varied ways location data can describe patterns of human behaviour should be examined. The objective of this review is to investigate behaviours described using indoor location data, and particularly the types of features extracted from RTLS data to describe behaviours. Four major applications were identified: health status monitoring, consumer behaviours, developmental behaviour, and workplace safety/efficiency. RTLS data features used to analyse behaviours were categorized into four groups: dwell time, activity level, trajectory, and proximity. Passive sensors that provide non-uniform data streams and features with lower complexity were common. Few studies analysed social behaviours between more than one individual at once. Less than half the health status monitoring studies examined clinical validity against gold-standard measures. Overall, spatiotemporal data from RTLS technologies are useful to identify behaviour patterns, provided there is sufficient richness in location data, the behaviour of interest is well-characterized, and a detailed feature analysis is undertaken.
Open AccessIndoor Location Data for Tracking Human Behaviours: A Scoping Review
Real-time location systems (RTLS) record locations of individuals over time and are valuable sources of spatiotemporal data that can be used to understand patterns of human behaviour. Location data are used in a wide breadth of applications, from locating individuals to contact tracing or monitoring health markers. To support the use of RTLS in many applications, the varied ways location data can describe patterns of human behaviour should be examined. The objective of this review is to investigate behaviours described using indoor location data, and particularly the types of features extracted from RTLS data to describe behaviours. Four major applications were identified: health status monitoring, consumer behaviours, developmental behaviour, and workplace safety/efficiency. RTLS data features used to analyse behaviours were categorized into four groups: dwell time, activity level, trajectory, and proximity. Passive sensors that provide non-uniform data streams and features with lower complexity were common. Few studies analysed social behaviours between more than one individual at once. Less than half the health status monitoring studies examined clinical validity against gold-standard measures. Overall, spatiotemporal data from RTLS technologies are useful to identify behaviour patterns, provided there is sufficient richness in location data, the behaviour of interest is well-characterized, and a detailed feature analysis is undertaken.
- 13 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 28 (2) , 541-549
Error Augmentation in Immersive Virtual Reality for Bimanual Upper-Limb Rehabilitation in Individuals With and Without Hemiplegic Cerebral Palsy
(WC:200/200) With more readily available commercial immersive virtual reality (VR) technologies, the potential of new feedback strategies as tools to facilitate motor rehabilitation should be investigated. Augmented feedback or error augmentation (EA) can easily be shown in a virtual environment. Here, visual EA provided via immersive VR was tested for its effectiveness to improve bimanual symmetry in a reaching task. A single-session crossover design was used to test two training cases, with or without EA. With EA, the distance between hands in the forward direction was augmented. Participants were recruited from typically developing (TD) populations (n = 12, ages 13-21) and performed in an adapted environment with an initial asymmetry between limbs. Also, five participants with hemiplegic cerebral palsy (CP) (ages 14-21, MACS I-III) completed the study. Among TD participants, a significantly larger change in symmetry in the adapted environment was shown after EA than training without EA (F(1,10) = 9.64, p = 0.01). Each participant in the CP group also improved more after EA training (8.8-103.7)%, such that they achieved lower symmetry error after training with EA. As participants in both groups adapted more symmetrically with EA, beneficial changes from this training method could be evaluated in future studies for longer-term functional changes.
- 13 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 28 (2) , 541-549
Error Augmentation in Immersive Virtual Reality for Bimanual Upper-Limb Rehabilitation in Individuals With and Without Hemiplegic Cerebral Palsy
(WC:200/200) With more readily available commercial immersive virtual reality (VR) technologies, the potential of new feedback strategies as tools to facilitate motor rehabilitation should be investigated. Augmented feedback or error augmentation (EA) can easily be shown in a virtual environment. Here, visual EA provided via immersive VR was tested for its effectiveness to improve bimanual symmetry in a reaching task. A single-session crossover design was used to test two training cases, with or without EA. With EA, the distance between hands in the forward direction was augmented. Participants were recruited from typically developing (TD) populations (n = 12, ages 13-21) and performed in an adapted environment with an initial asymmetry between limbs. Also, five participants with hemiplegic cerebral palsy (CP) (ages 14-21, MACS I-III) completed the study. Among TD participants, a significantly larger change in symmetry in the adapted environment was shown after EA than training without EA (F(1,10) = 9.64, p = 0.01). Each participant in the CP group also improved more after EA training (8.8-103.7)%, such that they achieved lower symmetry error after training with EA. As participants in both groups adapted more symmetrically with EA, beneficial changes from this training method could be evaluated in future studies for longer-term functional changes.
- Open Access
- 6 June 2019
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 4 (1) , e12291
Determining the Accuracy of Oculus Touch Controllers for Motor Rehabilitation Applications Using Quantifiable Upper Limb Kinematics: Validation Study
Background: As commercial motion tracking technology becomes more readily available, it is necessary to evaluate the accuracy of these systems before using them for biomechanical and motor rehabilitation applications. Objective: This study aimed to evaluate the relative position accuracy of the Oculus Touch controllers in a 2.4 x 2.4 m play-space. Methods: Static data samples (n=180) were acquired from the Oculus Touch controllers at step sizes ranging from 5 to 500 mm along 16 different points on the play-space floor with graph paper in the x (width), y (height), and z (depth) directions. The data were compared with reference values using measurements from digital calipers, accurate to 0.01 mm; physical blocks, for which heights were confirmed with digital calipers; and for larger step sizes (300 and 500 mm), a ruler with hatch marks to millimeter units. Results: It was found that the maximum position accuracy error of the system was 3.5 ± 2.5 mm at the largest step size of 500 mm along the z-axis. When normalized to step size, the largest error found was 12.7 ± 9.9% at the smallest step size in the y-axis at 6.23 mm. When the step size was <10 mm in any direction, the relative position accuracy increased considerably to above 2% (approximately 2 mm at maximum). An average noise value of 0.036 mm was determined. A comparison of these values to cited visual, goniometric, and proprioceptive resolutions concludes that this system is viable for tracking upper-limb movements for biomechanical and rehabilitation applications. The accuracy of the system was also compared with accuracy values from previous studies using other commercially available devices and a multicamera, marker-based professional motion tracking system. Conclusions: The study found that the linear position accuracy of the Oculus Touch controllers was within an agreeable range for measuring human kinematics in rehabilitative upper-limb exercise protocols. Further testing is required to ascertain acceptable repeatability in multiple sessions and rotational accuracy.
- 6 June 2019
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 4 (1) , e12291
Open AccessDetermining the Accuracy of Oculus Touch Controllers for Motor Rehabilitation Applications Using Quantifiable Upper Limb Kinematics: Validation Study
Background: As commercial motion tracking technology becomes more readily available, it is necessary to evaluate the accuracy of these systems before using them for biomechanical and motor rehabilitation applications. Objective: This study aimed to evaluate the relative position accuracy of the Oculus Touch controllers in a 2.4 x 2.4 m play-space. Methods: Static data samples (n=180) were acquired from the Oculus Touch controllers at step sizes ranging from 5 to 500 mm along 16 different points on the play-space floor with graph paper in the x (width), y (height), and z (depth) directions. The data were compared with reference values using measurements from digital calipers, accurate to 0.01 mm; physical blocks, for which heights were confirmed with digital calipers; and for larger step sizes (300 and 500 mm), a ruler with hatch marks to millimeter units. Results: It was found that the maximum position accuracy error of the system was 3.5 ± 2.5 mm at the largest step size of 500 mm along the z-axis. When normalized to step size, the largest error found was 12.7 ± 9.9% at the smallest step size in the y-axis at 6.23 mm. When the step size was <10 mm in any direction, the relative position accuracy increased considerably to above 2% (approximately 2 mm at maximum). An average noise value of 0.036 mm was determined. A comparison of these values to cited visual, goniometric, and proprioceptive resolutions concludes that this system is viable for tracking upper-limb movements for biomechanical and rehabilitation applications. The accuracy of the system was also compared with accuracy values from previous studies using other commercially available devices and a multicamera, marker-based professional motion tracking system. Conclusions: The study found that the linear position accuracy of the Oculus Touch controllers was within an agreeable range for measuring human kinematics in rehabilitative upper-limb exercise protocols. Further testing is required to ascertain acceptable repeatability in multiple sessions and rotational accuracy.
- Open Access
- 21 September 2018
- Published by JMIR Publications Inc. in JMIR Preprints
Determining the Accuracy of Oculus Touch Controllers for Motor Rehabilitation Applications Using Quantifiable Upper Limb Kinematics: Validation Study (Preprint)
BACKGROUND As commercial motion tracking technology becomes more readily available, it is necessary to evaluate the accuracy of these systems before using them for biomechanical and motor rehabilitation applications. OBJECTIVE This study aimed to evaluate the relative position accuracy of the Oculus Touch controllers in a 2.4 x 2.4 m play-space. METHODS Static data samples (n=180) were acquired from the Oculus Touch controllers at step sizes ranging from 5 to 500 mm along 16 different points on the play-space floor with graph paper in the x (width), y (height), and z (depth) directions. The data were compared with reference values using measurements from digital calipers, accurate to 0.01 mm; physical blocks, for which heights were confirmed with digital calipers; and for larger step sizes (300 and 500 mm), a ruler with hatch marks to millimeter units. RESULTS It was found that the maximum position accuracy error of the system was 3.5 ± 2.5 mm at the largest step size of 500 mm along the z-axis. When normalized to step size, the largest error found was 12.7 ± 9.9% at the smallest step size in the y-axis at 6.23 mm. When the step size was <10 mm in any direction, the relative position accuracy increased considerably to above 2% (approximately 2 mm at maximum). An average noise value of 0.036 mm was determined. A comparison of these values to cited visual, goniometric, and proprioceptive resolutions concludes that this system is viable for tracking upper-limb movements for biomechanical and rehabilitation applications. The accuracy of the system was also compared with accuracy values from previous studies using other commercially available devices and a multicamera, marker-based professional motion tracking system. CONCLUSIONS The study found that the linear position accuracy of the Oculus Touch controllers was within an agreeable range for measuring human kinematics in rehabilitative upper-limb exercise protocols. Further testing is required to ascertain acceptable repeatability in multiple sessions and rotational accuracy.
- 21 September 2018
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessDetermining the Accuracy of Oculus Touch Controllers for Motor Rehabilitation Applications Using Quantifiable Upper Limb Kinematics: Validation Study (Preprint)
BACKGROUND As commercial motion tracking technology becomes more readily available, it is necessary to evaluate the accuracy of these systems before using them for biomechanical and motor rehabilitation applications. OBJECTIVE This study aimed to evaluate the relative position accuracy of the Oculus Touch controllers in a 2.4 x 2.4 m play-space. METHODS Static data samples (n=180) were acquired from the Oculus Touch controllers at step sizes ranging from 5 to 500 mm along 16 different points on the play-space floor with graph paper in the x (width), y (height), and z (depth) directions. The data were compared with reference values using measurements from digital calipers, accurate to 0.01 mm; physical blocks, for which heights were confirmed with digital calipers; and for larger step sizes (300 and 500 mm), a ruler with hatch marks to millimeter units. RESULTS It was found that the maximum position accuracy error of the system was 3.5 ± 2.5 mm at the largest step size of 500 mm along the z-axis. When normalized to step size, the largest error found was 12.7 ± 9.9% at the smallest step size in the y-axis at 6.23 mm. When the step size was <10 mm in any direction, the relative position accuracy increased considerably to above 2% (approximately 2 mm at maximum). An average noise value of 0.036 mm was determined. A comparison of these values to cited visual, goniometric, and proprioceptive resolutions concludes that this system is viable for tracking upper-limb movements for biomechanical and rehabilitation applications. The accuracy of the system was also compared with accuracy values from previous studies using other commercially available devices and a multicamera, marker-based professional motion tracking system. CONCLUSIONS The study found that the linear position accuracy of the Oculus Touch controllers was within an agreeable range for measuring human kinematics in rehabilitative upper-limb exercise protocols. Further testing is required to ascertain acceptable repeatability in multiple sessions and rotational accuracy.