Hironori Tohmyoh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hironori Tohmyoh has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
- Masumi Saka
Department of Nanomechanics, Tohoku University
19 shared publications Masumi Saka
Department of Nanomechanics, Tohoku University, Aoba 6-6-01, Aramaki, Aoba-ku, Sendai 980-8579, Japan
8 shared publicationsJiro Utsunomiya
Keihin Corporation, Houshakuji 2021‐8, Takanezawa, Shioya, Tochigi 329‐1233, Japan
7 shared publicationsYoshikatsu Nakano
Institute of Fluid Science, Tohoku University, Katahira 2‐2‐1, Aoba‐ku, Sendai 980‐8577, Japan
7 shared publications- Yoshinari Kimura
Department of Finemechanics, Graduate School of Engineering, Tohoku University, Sendai, Japan
7 shared publications Satoru Fukui
Tohoku University
5 shared publications
Latest Publications
- Open Access
- 9 May 2026
- Published by Elsevier in Applied Surface Science Advances
- Vol. 34
Experimental evaluation of the mechanical properties of iron oxide nanowires for chemical sensor applications
- 9 May 2026
- Published by Elsevier in Applied Surface Science Advances
- Vol. 34
Open AccessExperimental evaluation of the mechanical properties of iron oxide nanowires for chemical sensor applications
- Open Access
- 8 April 2026
- Published by Elsevier in SSRN Electronic Journal
Multiscale correlation of chemical structure, lamellar, and damage evolution in short-carbon-fiber-reinforced polyamide 6 under thermo-oxidative recycling
Short-carbon-fiber-reinforced polyamide 6 (sCF/PA6) composites are attractive as lightweight, high-performance thermoplastics. However, the mechanisms governing changes in their mechanical properties during recycling remain unclear. This study applied a laboratory-scale recycling process consisting of repeated thermal treatment in air and melt-kneading to sCF/PA6 composites to elucidate the structure–property relationships from chemical, microstructural, and mechanical perspectives. Fourier transform infrared spectroscopy and gel permeation chromatography revealed that thermo-oxidative degradation progressed during recycling, forming carbonyl groups and reducing the molecular weight owing to PA6 chain scission. Tensile testing and X-ray micro-computed tomography revealed that non-heat-treated specimens had increased failure strain after repeated recycling, whereas heat-treated specimens showed lower ductility and transitioned to brittle fracture behavior. However, the Young’s modulus remained nearly constant or increased slightly. Differential scanning calorimetry showed increased crystallinity, whereas small-angle X-ray scattering revealed a decrease in the long lamellar period. Structure–property analysis correlated the decreased failure strain with thinner amorphous layers, while the Young’s modulus showed a weak positive correlation with the crystalline-to-amorphous-layer thickness ratio. Moreover, a stiffness–ductility tradeoff, wherein stiffness slightly increased while ductility significantly decreased as the structure evolved. Although the average fiber length decreased after the first recycling cycle, the recycled specimens did not significantly differ, indicating that the fiber length did not primarily govern the changes in mechanical behavior. Instead, the mechanical response of the sCF/PA6 composites during recycling was dominated by the thermo-oxidative degradation of the PA6 matrix and the associated evolution of the lamellar structure.
- 8 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMultiscale correlation of chemical structure, lamellar, and damage evolution in short-carbon-fiber-reinforced polyamide 6 under thermo-oxidative recycling
Short-carbon-fiber-reinforced polyamide 6 (sCF/PA6) composites are attractive as lightweight, high-performance thermoplastics. However, the mechanisms governing changes in their mechanical properties during recycling remain unclear. This study applied a laboratory-scale recycling process consisting of repeated thermal treatment in air and melt-kneading to sCF/PA6 composites to elucidate the structure–property relationships from chemical, microstructural, and mechanical perspectives. Fourier transform infrared spectroscopy and gel permeation chromatography revealed that thermo-oxidative degradation progressed during recycling, forming carbonyl groups and reducing the molecular weight owing to PA6 chain scission. Tensile testing and X-ray micro-computed tomography revealed that non-heat-treated specimens had increased failure strain after repeated recycling, whereas heat-treated specimens showed lower ductility and transitioned to brittle fracture behavior. However, the Young’s modulus remained nearly constant or increased slightly. Differential scanning calorimetry showed increased crystallinity, whereas small-angle X-ray scattering revealed a decrease in the long lamellar period. Structure–property analysis correlated the decreased failure strain with thinner amorphous layers, while the Young’s modulus showed a weak positive correlation with the crystalline-to-amorphous-layer thickness ratio. Moreover, a stiffness–ductility tradeoff, wherein stiffness slightly increased while ductility significantly decreased as the structure evolved. Although the average fiber length decreased after the first recycling cycle, the recycled specimens did not significantly differ, indicating that the fiber length did not primarily govern the changes in mechanical behavior. Instead, the mechanical response of the sCF/PA6 composites during recycling was dominated by the thermo-oxidative degradation of the PA6 matrix and the associated evolution of the lamellar structure.
- Open Access
- 1 January 2026
- Published by Wiley in International Journal of Energy Research
- Vol. 2026 (1)
Design Concept of Adjustable Thermoelectric Generators Comprising Multiple Thermoelectric Modules: Output Power and Internal Resistance Control
This paper reports on a design concept for an adjustable thermoelectric generator (TEG) comprising multiple thermoelectric (TE) modules. This TEG allows for controlling the output power and internal resistance of the TEG by adjusting the number of TE modules connected. First, plate‐type TE modules were fabricated by depositing an Al layer on a Fe plate (using easily available materials). TEGs were fabricated by connecting up to eight modules by alligator clips, and the TE performance of TEGs with different numbers of modules was evaluated. It was verified experimentally that the Seebeck coefficient of the TEGs increased in proportion to the number of TE modules. However, the maximum output power did not do so due to the high connection resistance of the alligator clips. Next, the connection resistance between Fe and Al plates was measured when the plates were stacked in various ways and found that Cu plates (sandwiched between the plates and fixed with a jig) realized low connection resistance. Based on the above experimental results, the relationships between TE performance of the TEGs and the number of TE modules connected were predicted by a theoretical model considering the connection resistance between TE modules. This paper introduces the design concept of a TEG, which controls output power and internal resistance by adjusting the number of TE modules to take into account the resistance of the device being powered.
- 1 January 2026
- Published by Wiley in International Journal of Energy Research
- Vol. 2026 (1)
Open AccessDesign Concept of Adjustable Thermoelectric Generators Comprising Multiple Thermoelectric Modules: Output Power and Internal Resistance Control
This paper reports on a design concept for an adjustable thermoelectric generator (TEG) comprising multiple thermoelectric (TE) modules. This TEG allows for controlling the output power and internal resistance of the TEG by adjusting the number of TE modules connected. First, plate‐type TE modules were fabricated by depositing an Al layer on a Fe plate (using easily available materials). TEGs were fabricated by connecting up to eight modules by alligator clips, and the TE performance of TEGs with different numbers of modules was evaluated. It was verified experimentally that the Seebeck coefficient of the TEGs increased in proportion to the number of TE modules. However, the maximum output power did not do so due to the high connection resistance of the alligator clips. Next, the connection resistance between Fe and Al plates was measured when the plates were stacked in various ways and found that Cu plates (sandwiched between the plates and fixed with a jig) realized low connection resistance. Based on the above experimental results, the relationships between TE performance of the TEGs and the number of TE modules connected were predicted by a theoretical model considering the connection resistance between TE modules. This paper introduces the design concept of a TEG, which controls output power and internal resistance by adjusting the number of TE modules to take into account the resistance of the device being powered.
- Open Access
- 22 October 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (16)
Modulation of interface states at Fe/Al interface for thermoelectric module applications
Metal/metal interfaces play a crucial role in the practical applications of common metallic thermoelectric modules (TEMs), which economically convert heat to electricity in an environmentally friendly manner. The effect of modulation of Fe/Al interface states, introduced by the application of large bias currents, on the thermoelectric properties of the Fe/Al-based TEMs was investigated. The Seebeck coefficients of TEMs after applying bias currents in the Fe → Al and Al → Fe directions increased from 2.1 and 2.5 to 2.5 and 2.9 μV K−1, respectively, with prolonged applying them. The densities of Fe/Al interface states, calculated based on the capacitance– and conductance–frequency characteristics of the only Fe/Al interfacial samples, decreased from 2.6 × 1014 to 1.8 × 1011 cm−2 eV−1 with prolonged applying the bias currents. These results indicate that the TEMs’ Seebeck coefficients and the densities of Fe/Al interface states were negatively correlated. To enhance Seebeck coefficients, reductions in densities of interface states between dissimilar metals provide an alternative strategy for designing high-performance metallic TEMs.
- 22 October 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (16)
Open AccessModulation of interface states at Fe/Al interface for thermoelectric module applications
Metal/metal interfaces play a crucial role in the practical applications of common metallic thermoelectric modules (TEMs), which economically convert heat to electricity in an environmentally friendly manner. The effect of modulation of Fe/Al interface states, introduced by the application of large bias currents, on the thermoelectric properties of the Fe/Al-based TEMs was investigated. The Seebeck coefficients of TEMs after applying bias currents in the Fe → Al and Al → Fe directions increased from 2.1 and 2.5 to 2.5 and 2.9 μV K−1, respectively, with prolonged applying them. The densities of Fe/Al interface states, calculated based on the capacitance– and conductance–frequency characteristics of the only Fe/Al interfacial samples, decreased from 2.6 × 1014 to 1.8 × 1011 cm−2 eV−1 with prolonged applying the bias currents. These results indicate that the TEMs’ Seebeck coefficients and the densities of Fe/Al interface states were negatively correlated. To enhance Seebeck coefficients, reductions in densities of interface states between dissimilar metals provide an alternative strategy for designing high-performance metallic TEMs.
- Open Access
- 2 September 2025
- Published by Elsevier in Materials Today Communications
- Vol. 49
Welding of thin Pt wires by instantaneous current application
- 2 September 2025
- Published by Elsevier in Materials Today Communications
- Vol. 49
Open AccessWelding of thin Pt wires by instantaneous current application
- Open Access
- 1 September 2025
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 44 (4) , 1-9
Simultaneous Thickness Measurement of Double-Sided Coatings Using Acoustic Resonant Imaging Technique
In this study, the coating thickness of a double-sided coating processed by cathodic electrodeposition was measured and visualized using the acoustic resonant imaging technique. This method analyzes the resonant frequency and amplitude spectrum of echoes, enabling the visualization of thin coating thickness. Because changes in the coating thickness owing to the characteristics of the electrodeposition process are expected to influence the properties, we experimentally investigated the relationship between the coating thickness and the resonant frequency. An experimentally established relationship between coating thickness and resonant frequency indicated that a 33% reduction in thickness corresponded to an approximate 10% increase in sound velocity. Based on this relationship, the coating thicknesses on both surfaces were simultaneously visualized. Validation through cross-sectional microscopy confirmed the accuracy of the thickness measurements, with an average error of less than 2%, demonstrating the accuracy of this method for precise and simultaneous coating thickness evaluation.
- 1 September 2025
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 44 (4) , 1-9
Open AccessSimultaneous Thickness Measurement of Double-Sided Coatings Using Acoustic Resonant Imaging Technique
In this study, the coating thickness of a double-sided coating processed by cathodic electrodeposition was measured and visualized using the acoustic resonant imaging technique. This method analyzes the resonant frequency and amplitude spectrum of echoes, enabling the visualization of thin coating thickness. Because changes in the coating thickness owing to the characteristics of the electrodeposition process are expected to influence the properties, we experimentally investigated the relationship between the coating thickness and the resonant frequency. An experimentally established relationship between coating thickness and resonant frequency indicated that a 33% reduction in thickness corresponded to an approximate 10% increase in sound velocity. Based on this relationship, the coating thicknesses on both surfaces were simultaneously visualized. Validation through cross-sectional microscopy confirmed the accuracy of the thickness measurements, with an average error of less than 2%, demonstrating the accuracy of this method for precise and simultaneous coating thickness evaluation.
- Open Access
- 14 August 2025
- Published by Elsevier in Composites Science and Technology
- Vol. 271
Experimental and numerical evaluation of the interfacial adhesion properties of additively manufactured carbon-fiber-reinforced thermoplastic/64 titanium hybrids
- 14 August 2025
- Published by Elsevier in Composites Science and Technology
- Vol. 271
Open AccessExperimental and numerical evaluation of the interfacial adhesion properties of additively manufactured carbon-fiber-reinforced thermoplastic/64 titanium hybrids
- 4 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (8) , 1-4
ZnO-Based Chemiresistive Ion Sensors for Identifying Alkali Metal and Alkaline Earth Metal Ions in Solutions
Metal-oxide-semiconductor-based chemiresistive ion sensors are promising for daily health monitoring applications. This study demonstrates ZnO-based chemiresistive sensors for detecting and identifying ions in solutions. Sensors based on nanoporous ZnO, both without and with NiO particles, exhibited distinct ion sensing performances for potassium, sodium, and calcium ions in solutions at 30°C. These performances depended on the ion species and concentrations and the presence of NiO particles. Under direct current (DC) bias, the percentage response changes to 100-ppm calcium ions were +518 and −193% for the ZnO and ZnO/NiO sensors, respectively. Under alternating current (AC) bias, the ZnO sensor showed the smallest response change (−26.1%) to 100-ppm potassium ions, whereas the ZnO/NiO sensor exhibited its most significant response change (−49.6%) to 100-ppm calcium ions. Principal component analysis, using these sensing parameters, demonstrated the possibility of differentiating and identifying each ion species.
- 4 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (8) , 1-4
ZnO-Based Chemiresistive Ion Sensors for Identifying Alkali Metal and Alkaline Earth Metal Ions in Solutions
Metal-oxide-semiconductor-based chemiresistive ion sensors are promising for daily health monitoring applications. This study demonstrates ZnO-based chemiresistive sensors for detecting and identifying ions in solutions. Sensors based on nanoporous ZnO, both without and with NiO particles, exhibited distinct ion sensing performances for potassium, sodium, and calcium ions in solutions at 30°C. These performances depended on the ion species and concentrations and the presence of NiO particles. Under direct current (DC) bias, the percentage response changes to 100-ppm calcium ions were +518 and −193% for the ZnO and ZnO/NiO sensors, respectively. Under alternating current (AC) bias, the ZnO sensor showed the smallest response change (−26.1%) to 100-ppm potassium ions, whereas the ZnO/NiO sensor exhibited its most significant response change (−49.6%) to 100-ppm calcium ions. Principal component analysis, using these sensing parameters, demonstrated the possibility of differentiating and identifying each ion species.