Paola Piedimonte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Paola Piedimonte has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Laura Sola
Institute of Chemical and Technological Science “Giulio Natta”, National Research Council of Italy
2 shared publications Marcella Chiari
Istituto di Scienze e Tecnologie Chimiche (SCITEC-CNR)
2 shared publications- Marco Sampietro
Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
2 shared publications - Piero Borga
Dipartimento di Fisica, Politecnico di Milano, Via G. Colombo 81, 20133 Milano, Italy
2 shared publications - Alessandro Gori
Consiglio Nazionale delle Ricerche, Istituto di Scienze e Tecnologie Chimiche “Giulio Natta” (SCITEC)
1 shared publication Andrea Melloni
Department of Physics, Politecnico di Milano, Piazza L. da Vinci 32, Milan, 20133, Italy
1 shared publication
Latest Publications
- Open Access
- 20 March 2024
- Published by Springer Nature
- p. 55-64
Electronic Bio-Reconfigurable Impedance Platform for High Sensitivity Detection of Target Analytes
The present research presents a portable bioelectronic platform for multiplex detection to read biosensor chips with several sensing sites for real-time analyte capture. The technique is based on Differential Impedance Sensing (DIS) of the target through functionalized nanoparticle amplification. Gold-interdigitated microelectrodes are the core of the biosensing system. They are designed in a differential configuration, reference and active sensor, to counteract all possible mismatches such as temperature fluctuations and variations in the ion content of the solution. The surface of the sensor is biochemically functionalized with a synthetic probe specifically developed for the selected target. The successful combination of all of these elements allowed the system to detect IgG antibodies spiked in buffer with a limit of detection of below 100 pg/mL. In a real case study for viral infection diagnosis, the system has been challenged with infected human serum samples for digital counts of anti-dengue virus antibodies, achieving the detection of clinically relevant target concentrations. Also, the bio-reconfigurability of the system has been successfully tested with oligonucleotide detection down to pM target concentration. To allow the portability of the entire measurement setup, the setup has been equipped with a custom electronic board based on an FPGA module allowing a multiplexing approach for the parallel reading of several electrodes. The final system provides simple and effective bio-reconfigurability, exploiting advances in bio-recognition through proper probe selection and boosting the possible use of multiplex sensing to a broad spectrum of needs.
- 20 March 2024
- Published by Springer Nature
- p. 55-64
Open AccessElectronic Bio-Reconfigurable Impedance Platform for High Sensitivity Detection of Target Analytes
The present research presents a portable bioelectronic platform for multiplex detection to read biosensor chips with several sensing sites for real-time analyte capture. The technique is based on Differential Impedance Sensing (DIS) of the target through functionalized nanoparticle amplification. Gold-interdigitated microelectrodes are the core of the biosensing system. They are designed in a differential configuration, reference and active sensor, to counteract all possible mismatches such as temperature fluctuations and variations in the ion content of the solution. The surface of the sensor is biochemically functionalized with a synthetic probe specifically developed for the selected target. The successful combination of all of these elements allowed the system to detect IgG antibodies spiked in buffer with a limit of detection of below 100 pg/mL. In a real case study for viral infection diagnosis, the system has been challenged with infected human serum samples for digital counts of anti-dengue virus antibodies, achieving the detection of clinically relevant target concentrations. Also, the bio-reconfigurability of the system has been successfully tested with oligonucleotide detection down to pM target concentration. To allow the portability of the entire measurement setup, the setup has been equipped with a custom electronic board based on an FPGA module allowing a multiplexing approach for the parallel reading of several electrodes. The final system provides simple and effective bio-reconfigurability, exploiting advances in bio-recognition through proper probe selection and boosting the possible use of multiplex sensing to a broad spectrum of needs.
- 25 September 2022
- Published by Springer Nature
- Vol. 2578, 191-198
Peptide-Based Sensor and Microfluidic Platform for IgG Antibody Detection by Differential Impedance Sensing
Serological assays enable infection screening as relatively easy-to-operate approaches compared with standard methods. In addition, to be relevant for early diagnosis, specific antibody detection is important for epidemiological surveillance and quantitative detection has potential significance for evaluating the severity and prognosis of different diseases. Here, we describe the detection process based on differential impedance sensing of IgG antibodies labeled with polystyrene nanoparticles. The electrode differential configuration, the amplification with nanoparticle functionalization, the electronic reading, and the microfluidic protocol allow to reach a limit of detection below 100 pg/mL for commercial IgG antibody spiked in buffer. Key words Differential impedance detection Microfluidic platform Antibody detection Serological assay Nanoparticle Interdigitated microelectrode
- 25 September 2022
- Published by Springer Nature
- Vol. 2578, 191-198
Peptide-Based Sensor and Microfluidic Platform for IgG Antibody Detection by Differential Impedance Sensing
Serological assays enable infection screening as relatively easy-to-operate approaches compared with standard methods. In addition, to be relevant for early diagnosis, specific antibody detection is important for epidemiological surveillance and quantitative detection has potential significance for evaluating the severity and prognosis of different diseases. Here, we describe the detection process based on differential impedance sensing of IgG antibodies labeled with polystyrene nanoparticles. The electrode differential configuration, the amplification with nanoparticle functionalization, the electronic reading, and the microfluidic protocol allow to reach a limit of detection below 100 pg/mL for commercial IgG antibody spiked in buffer. Key words Differential impedance detection Microfluidic platform Antibody detection Serological assay Nanoparticle Interdigitated microelectrode
- Open Access
Active Opto-Magnetic Biosensing with Silicon Microring Resonators
Integrated optical biosensors are gaining increasing attention for their exploitation in lab-on-chip platforms. The standard detection method is based on the measurement of the shift of some optical quantity induced by the immobilization of target molecules at the surface of an integrated optical element upon biomolecular recognition. However, this requires the acquisition of said quantity over the whole hybridization process, which can take hours, during which any external perturbation (e.g., temperature and mechanical instability) can seriously affect the measurement and contribute to a sizeable percentage of invalid tests. Here, we present a different assay concept, named Opto-Magnetic biosensing, allowing us to optically measure off-line (i.e., post hybridization) tiny variations of the effective refractive index seen by microring resonators upon immobilization of magnetic nanoparticles labelling target molecules. Bound magnetic nanoparticles are driven in oscillation by an external AC magnetic field and the corresponding modulation of the microring transfer function, due to the effective refractive index dependence on the position of the particles above the ring, is recorded using a lock-in technique. For a model system of DNA biomolecular recognition we reached a lowest detected concentration on the order of 10 m, and data analysis shows an expected effective refractive index variation limit of detection of RIU, in a measurement time of just a few seconds.Open AccessActive Opto-Magnetic Biosensing with Silicon Microring Resonators
Integrated optical biosensors are gaining increasing attention for their exploitation in lab-on-chip platforms. The standard detection method is based on the measurement of the shift of some optical quantity induced by the immobilization of target molecules at the surface of an integrated optical element upon biomolecular recognition. However, this requires the acquisition of said quantity over the whole hybridization process, which can take hours, during which any external perturbation (e.g., temperature and mechanical instability) can seriously affect the measurement and contribute to a sizeable percentage of invalid tests. Here, we present a different assay concept, named Opto-Magnetic biosensing, allowing us to optically measure off-line (i.e., post hybridization) tiny variations of the effective refractive index seen by microring resonators upon immobilization of magnetic nanoparticles labelling target molecules. Bound magnetic nanoparticles are driven in oscillation by an external AC magnetic field and the corresponding modulation of the microring transfer function, due to the effective refractive index dependence on the position of the particles above the ring, is recorded using a lock-in technique. For a model system of DNA biomolecular recognition we reached a lowest detected concentration on the order of 10 m, and data analysis shows an expected effective refractive index variation limit of detection of RIU, in a measurement time of just a few seconds. - 15 January 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 202, 113996
Differential Impedance Sensing platform for high selectivity antibody detection down to few counts: A case study on Dengue Virus
- 15 January 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 202, 113996
Differential Impedance Sensing platform for high selectivity antibody detection down to few counts: A case study on Dengue Virus
- Open Access
- 11 August 2020
- Published by MDPI AG in Nanomaterials
- Vol. 10 (8) , 1576
Ferroelectricity in Si-Doped Hafnia: Probing Challenges in Absence of Screening Charges
The ability to develop ferroelectric materials using binary oxides is critical to enable novel low-power, high-density non-volatile memory and fast switching logic. The discovery of ferroelectricity in hafnia-based thin films, has focused the hopes of the community on this class of materials to overcome the existing problems of perovskite-based integrated ferroelectrics. However, both the control of ferroelectricity in doped-HfO2 and the direct characterization at the nanoscale of ferroelectric phenomena, are increasingly difficult to achieve. The main limitations are imposed by the inherent intertwining of ferroelectric and dielectric properties, the role of strain, interfaces and electric field-mediated phase, and polarization changes. In this work, using Si-doped HfO2 as a material system, we performed a correlative study with four scanning probe techniques for the local sensing of intrinsic ferroelectricity on the oxide surface. Putting each technique in perspective, we demonstrated that different origins of spatially resolved contrast can be obtained, thus highlighting possible crosstalk not originated by a genuine ferroelectric response. By leveraging the strength of each method, we showed how intrinsic processes in ultrathin dielectrics, i.e., electronic leakage, existence and generation of energy states, charge trapping (de-trapping) phenomena, and electrochemical effects, can influence the sensed response. We then proceeded to initiate hysteresis loops by means of tip-induced spectroscopic cycling (i.e., “wake-up”), thus observing the onset of oxide degradation processes associated with this step. Finally, direct piezoelectric effects were studied using the high pressure resulting from the probe’s confinement, noticing the absence of a net time-invariant piezo-generated charge. Our results are critical in providing a general framework of interpretation for multiple nanoscale processes impacting ferroelectricity in doped-hafnia and strategies for sensing it.
- 11 August 2020
- Published by MDPI AG in Nanomaterials
- Vol. 10 (8) , 1576
Open AccessFerroelectricity in Si-Doped Hafnia: Probing Challenges in Absence of Screening Charges
The ability to develop ferroelectric materials using binary oxides is critical to enable novel low-power, high-density non-volatile memory and fast switching logic. The discovery of ferroelectricity in hafnia-based thin films, has focused the hopes of the community on this class of materials to overcome the existing problems of perovskite-based integrated ferroelectrics. However, both the control of ferroelectricity in doped-HfO2 and the direct characterization at the nanoscale of ferroelectric phenomena, are increasingly difficult to achieve. The main limitations are imposed by the inherent intertwining of ferroelectric and dielectric properties, the role of strain, interfaces and electric field-mediated phase, and polarization changes. In this work, using Si-doped HfO2 as a material system, we performed a correlative study with four scanning probe techniques for the local sensing of intrinsic ferroelectricity on the oxide surface. Putting each technique in perspective, we demonstrated that different origins of spatially resolved contrast can be obtained, thus highlighting possible crosstalk not originated by a genuine ferroelectric response. By leveraging the strength of each method, we showed how intrinsic processes in ultrathin dielectrics, i.e., electronic leakage, existence and generation of energy states, charge trapping (de-trapping) phenomena, and electrochemical effects, can influence the sensed response. We then proceeded to initiate hysteresis loops by means of tip-induced spectroscopic cycling (i.e., “wake-up”), thus observing the onset of oxide degradation processes associated with this step. Finally, direct piezoelectric effects were studied using the high pressure resulting from the probe’s confinement, noticing the absence of a net time-invariant piezo-generated charge. Our results are critical in providing a general framework of interpretation for multiple nanoscale processes impacting ferroelectricity in doped-hafnia and strategies for sensing it.
- 21 May 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (8) , 084005
Silicon nanowires to detect electric signals from living cells
- 21 May 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (8) , 084005
Silicon nanowires to detect electric signals from living cells