Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


José Gustavo Coelho has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Numerical Simulation of a Low-head Axial Flow Microturbine Considering Cavitation and Sediment Flow

    by H. C. Wanzeler, J. G. Coelho, A. L. Amarante Mesquita, N. Manzanares Filho

    This article presents a numerical investigation of cavitation and sediment-induced erosion phenomena in an ultra-low-head axial hydraulic turbine designed to operate at a head of 4 m for small-scale applications. Computational Fluid Dynamics (CFD) simulations were used to assess the turbine’s hydraulic performance and to map regions of cavitation and erosive wear on its components. The simulations were performed using ANSYS CFX. The operating conditions and performance data used in the model were based on experimental results, which enabled validation of the numerical model. The turbine geometry was reconstructed from aerodynamic profiles and assembled in cylindrical coordinates. A three-dimensional mesh was generated for the different domains, with appropriate refinement in regions of high gradients to ensure mesh independence. In the simulations, the SST k-ω turbulence model was employed, with cavitation modeled using the Rayleigh–Plesset equation and Lagrangian tracking of solid particles to estimate erosion via the Finnie model. The particle dynamics analysis revealed a Stokes number much smaller than unity, indicating a high degree of hydrodynamic coupling where particles closely follow the fluid streamlines. The numerical results showed good agreement with the turbine’s experimental characteristic curves, validating the proposed model. The results indicated that vapor cavities formed preferentially on the suction side of the rotor blades, whereas particle-induced erosion was concentrated on the pressure side of the blades and on the casing walls. The analysis demonstrated that the simultaneous action of cavitation and sediment particles intensifies the damage mechanisms, accelerating surface wear and reducing the turbine’s service life.

  • Open Access

    Mitigating Particle Erosion in Axial-Flow Turbines Through Air Injection at the Inlet Rotor Section

    by José Gustavo Coelho, Rafael de Almeida, Hermeson Conceição Wanzeler, André Luiz Amarante Mesquita

    This study presents a computational analysis of degradation caused by cavitation and hydro-abrasive erosion in a low-head axial microturbine (H=4m), incorporating strategic air injection as a passive mitigation technique. Using Computational Fluid Dynamics (CFD) within ANSYS CFX 2025 R2, the study investigates hydrodynamic performance and the spatial distribution of surface wear across the runner blades. The turbine geometry was developed from aerofoil profiles mapped onto cylindrical coordinates, using a structured three-dimensional mesh with localized refinement to ensure grid independence. Physical modeling employed the Shear Stress Transport (SST) turbulence model, with cavitation dynamics governed by the Rayleigh–Plesset equation and sediment transport modeled using a Lagrangian framework incorporating the Finnie erosion model. The numerical framework showed good agreement with reference characteristic curves, confirming its predictive accuracy. The results indicate that vapor cavities form predominantly on the suction side, whereas solid particle erosion highly concentrated on the pressure side of the blades, where the outer 20% of the span accounts for over 91% of the total erosion intensity. Parametric assessments of controlled air injection revealed a highly non-linear mitigation response, identifying IAVF 2 as the optimal air-injection case. This configuration reduced integrated erosion by 0.95% and maximum localized erosion by 6.17%. In contrast, excessive air volumes accelerated material removal due to localized flow distortion. The findings indicate that carefully controlled air injection is a viable strategy for extending the operational lifespan of small-scale hydropower assets.

  • A comprehensive assessment of wind in Brazil

    by José Coelho, Francisco Aurilo Azevedo Pinho

    This study provides a comprehensive assessment of Brazil’s wind energy potential. The analysis encompasses electricity generation capacity and wind resource availability across multiple heights, covering both onshore and offshore contexts. In addition, the study examines the country’s electricity consumption profile and the broader generation–demand landscape, emphasizing the strategic role of wind power within the Brazilian energy matrix. A comparative perspective is also incorporated, positioning Brazil relative to other Latin American countries and to the BRICS group. The findings highlight the rapid and sustained expansion of Brazil’s wind sector, which is consolidating itself as one of the country’s most promising renewable energy sources. This evolution underscores wind energy’s growing contribution to diversifying the electricity mix, supporting a higher share of renewable generation. The study further reinforces the importance of policy frameworks that prioritize investment in wind energy as a means to strengthen energy security, improve competitiveness, and promote long-term sustainability.


  • Open Access

    Ensino, Pesquisa e Extensão Integrados no Curso de Engenharia Mecânica: Um Estudo de Caso

    by Jose Gustavo Coelho, Gustavo Bitencourth Leal Silva

    Os cursos de Engenharia Mecânica no Brasil possuem longa tradição, mas muitos ainda mantêm métodos de ensino semelhantes aos adotados há décadas. Com o avanço das tecnologias educacionais, novas abordagens têm se tornado viáveis e promissoras para a melhoria do processo de aprendizagem. Neste contexto, o presente trabalho apresenta uma aplicação bem-sucedida da integração entre ensino, pesquisa e extensão, desenvolvida de forma simultânea e articulada. O foco da iniciativa é o ensino de Mecânica dos Fluidos, aprofundado por meio de um Trabalho de Conclusão de Curso (TCC) voltado à simulação numérica, aplicado a um projeto de extensão universitária: uma competição de carros ecológicos. A metodologia descrita evidencia como as três dimensões do ensino superior foram integradas, promovendo uma formação mais ampla e aplicada. Como resultado, apresenta-se o projeto do veículo desenvolvido com base nos estudos realizados.

  • Open Access

    Design of Low-Cost Axial-Flow Turbines for Very Low-Head Micro-Hydropower Plants

    by Rodolfo Vitorino Correia Ramalho, Manoel José Mangabeira Pereira Filho, Manoel José dos Santos Sena, Rômulo Luis Santos Garreto Mendes, Siergberth Ugulino Neto, Davi Edson Sales e Souza, José Gustavo Coelho, Gilton Carlos de Andrade Furtado, André Luiz Amarante Mesquita

    In the Amazon, nearly one million people remain without reliable access to electricity. Moreover, the rural electricity grid is a mostly single-phase, ground-return type, with poor energy quality and high expenses. This study examines very low-head micro-hydropower (MHP) sites in the Amazon, emphasizing the integration of multiple axial-flow turbines. It includes an analysis of flow duration curves and key curves, both upstream and downstream, to design an MHP plant with multiple units targeting maximized energy yield. The presence of multiple turbines is crucial due to the substantial annual flow variation in the Amazon rivers. One contribution of this work is its scalable framework for ultra-low-head and high flow variability in small rivers, which is applicable in similar hydrological configurations, such as those typical of the Amazon. The design applies the minimum pressure coefficient criterion to increase turbine efficiency. Computational Fluid Dynamics (CFD) simulations forecast turbine efficiency and flow behavior. The CFD model is validated using experimental data available in the literature on a similar turbine, which is similarly used in this study for cost reasons, with discrepancies under 5%, demonstrating robust predictions of turbine efficiency and head behavior as a function of flow. This study also explores the implications of including inlet guide vanes (IGVs). We use a case study of a small bridge in Vila do Janari, situated in the southeastern part of Pará state, where heads range from 1.4 to 2.4 m and turbine flow rates span from 0.23 to 0.92 m3/s. The optimal configuration shows the potential to generate 63 MWh/year.


  • Open Access

    Design of Low-Cost Axial-Flow Hydraulic Turbines for Very Low Head Micro Hydro Power Plants

    by Rodolfo Vitorino Correia Ramalho, Manoel Pereira Filho, Manoel Sena, Romulo Mendes, Siergberth Ugulino Neto, Davi Souza, José Coelho, Gilton Carlos de A. Furtado, André Luiz Amarante Mesquita

    Nearly one million people in Amazon still don't have reliable access to electricity. Moreover, the rural electricity grid is mostly single-phase, ground-return type, with poor energy quality and high expenses. This study examines very low head micro hydro power (MHP) installations in Amazon, emphasizing the integration of multiple axial-flow turbines. It includes an analysis of flow duration curves and key curves, both upstream and downstream, to design an MHP with two or more units aimed at maximizing annual energy generation. The presence of multiple turbines is crucial due to the substantial annual flow variation in the Amazon rivers. This research supports the design of small, cost-effective axial-flow hydraulic turbines. The design applies the minimum pressure coefficient criterion to increase turbine efficiency. Computational Fluid Dynamics (CFD) simulations forecast turbine efficiency and flow behavior. The CFD model is validated against an existing experimental study from the literature on a propeller turbine with a curved plate blade, which is similarly used in this study due to cost reasons. The study also explores the implications of including inlet guide vanes (IGV). A case study is showcased for a location at a small bridge in Vila do Janari, situated in the southeastern part of Pará state, where heads range from 1.4 to 2.4 m and turbine flow rates span from 0.23 to 0.92 m³/s. The optimal configuration shows the potential to generate 63 MWh/year.


  • Investigation on reuse of energy at a sewage treatment plant and payback period

    by José Gustavo Coelho, Vinícius Oliveira Fávero, Guilherme Azevedo Oliveira, Francisco Aurilo Azevedo Pinho

    The reuse of energy is a topic currently being widely discussed around the world. This study analyzes the potential for energy reuse in treatment plants. Sewage Treatment Plants are responsible for treating the water present in the sewers of cities. The treated water returns clean to the river, and generally, the place of discharge has a high height and flow rate that can be harnessed for the generation of electric energy. This work investigates the feasibility of installing a Micro Hydroelectric Plant in the Treatment Station of the Uberaba River in Brazil. Hydraulic potential and investment analysis were used as viability criteria. For the study, a height of 6 m and an average flow rate of 0.465 m3/s were considered, which could generate about 22.51 kW using a Bulb water turbine. This power represents a return of US$1651.26 per month from the generation of electric energy. The estimated installation cost was US$32,966.73, and the payback period was found to be less than 2 years. There are 702 sewage treatment plants in Brazil alone, and hypothetical analyses were performed with flow rates ranging from 0.2 to 1 m3/s and heights ranging from 1 to 9 m. Motivating results with payback periods of less than 4 years were obtained for numerous hypothetical situations, which demonstrates the feasibility of installing Micro Hydropower Plants and achieving savings in the sewage treatment system.


  • Open Access

    Estudo de aplicação de uma micro central hidrelétrica para reaproveitamento de energia em estação tratamento de esgoto

    by Vinícius Oliveira Fávero, José Gustavo Coelho, Guilherme Azevedo Oliveira, Francisco Aurilo Azevedo Pinho

    As Estações de Tratamento de Esgoto, conhecidas como ETEs, tem a função de tratar a água presente nos esgotos das cidades devolvendo água límpida para o rio. O local de desague da água tratada geralmente apresenta características de queda d’água e vazão suficientes para gerar energia elétrica através da instalação de uma Micro Central Hidrelétrica (MCH). Foi analisada a ETE situada na cidade de Uberaba – MG e percebe-se que ela possui uma queda d’água de 6 metros com vazão média de 465 litros por segundo, podendo gerar cerca de 22,51 kW com a utilização de uma turbina Kaplan do tipo Bulbo. Essa potência tem um custo inicial de instalação com todos os componentes necessário da MCH de R$ 136.217,89. Após isso, o presente estudo foi expandido de forma hipotética para outras Estações de Tratamento de Esgoto, mostrando a potência encontrada e o custo de instalação, variando as alturas de 1 a 11 m e a vazão de 200 a 1100 L/s.

  • The wind potential in the Brazilian scenario

    by Amanda Maria Bizzinotto Ferreira, José Gustavo Coelho, Francisco Aurilo Azevedo Pinho

    The present paper presents an overview of the Brazilian wind potential based on data obtained from wind maps elaborated nationwide and statewide. The electricity generation potential and the available wind potential of the country are analysed for different heights and wind conditions. Both the onshore and offshore potential are considered in the estimates. An overview of the electricity consumption in the country and of the Brazilian electricity generation and demand are presented, analysing the role wind energy plays in this scenario. The analysis of the Brazilian wind potential together with the analysis of the existing wind technology revealed a growing and prospective wind market in the country, which has great potential still to be explored and is increasing its wind capacity over the years. All kinds of wind technology can find a suitable application in Brazil and the country can see a better integration of the wind energy to its energy matrix, allowing for a higher participation of renewables, higher electricity offer and smaller environmental impact.