Song Chi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Song Chi has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Jianhu Yan
Nanjing University of Science and Technology
4 shared publications Chenggang Wang
School of Automation, Nanjing University of Science and Technology, Nanjing, China
2 shared publications- Jian Guo
Nanjing University of Science and Technology
2 shared publications Christof Sihler
GE Global Research
1 shared publication- Di Zhang
Wuhan University of Technology
1 shared publication - Dong Dong
Center for Power Electronics Systems (CPES), Virginia Polytechnic Institute and State University, Blacksburg, VA, USA
1 shared publication
Latest Publications
- 23 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (1) , 3931-3941
Enhanced Two-Degree-of-Freedom Integrated Position Tracking Control Strategy for PMSM Servo Systems Based on SMCFO-LADRC
This paper proposes an enhanced two-degree-offreedom (2DOF) integrated position tracking control strategy based on an improved linear active disturbance rejection control method with the sliding mode compensation function observer (SMCFO-LADRC) for permanent magnet synchronous motor (PMSM) servo systems to achieve both high-precision position control and rapid dynamic response. The proposed sliding mode compensation function observer (SMCFO) integrates compensation function observer (CFO) with high-order fast nonsingular terminal sliding mode (HNFTSM), which exhibits superior disturbance observation ability compared to linear extended state observer (LESO). Moreover, the SMCFO-LADRC method is a genuine 2DOF control method that offers superior anti-disturbance performance over the linear active disturbance rejection control (LADRC) method and achieves complete decoupling of dynamic performance and disturbance rejection performance. Besides, the analysis of the SMCFO-LADRC method demonstrates its decoupling characteristics, stability, and disturbance observation capability. Finally, the effectiveness and theoretical correctness of the proposed SMCFO-LADRC method are validated through experiments, which confirm that the dynamic performance and disturbance rejection capability are mutually independent. So, the proposed method can significantly enhance the disturbance rejection performance of the PMSM servo system.
- 23 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (1) , 3931-3941
Enhanced Two-Degree-of-Freedom Integrated Position Tracking Control Strategy for PMSM Servo Systems Based on SMCFO-LADRC
This paper proposes an enhanced two-degree-offreedom (2DOF) integrated position tracking control strategy based on an improved linear active disturbance rejection control method with the sliding mode compensation function observer (SMCFO-LADRC) for permanent magnet synchronous motor (PMSM) servo systems to achieve both high-precision position control and rapid dynamic response. The proposed sliding mode compensation function observer (SMCFO) integrates compensation function observer (CFO) with high-order fast nonsingular terminal sliding mode (HNFTSM), which exhibits superior disturbance observation ability compared to linear extended state observer (LESO). Moreover, the SMCFO-LADRC method is a genuine 2DOF control method that offers superior anti-disturbance performance over the linear active disturbance rejection control (LADRC) method and achieves complete decoupling of dynamic performance and disturbance rejection performance. Besides, the analysis of the SMCFO-LADRC method demonstrates its decoupling characteristics, stability, and disturbance observation capability. Finally, the effectiveness and theoretical correctness of the proposed SMCFO-LADRC method are validated through experiments, which confirm that the dynamic performance and disturbance rejection capability are mutually independent. So, the proposed method can significantly enhance the disturbance rejection performance of the PMSM servo system.
- 21 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (3) , 6801-6811
Double-Sided Single-Set Winding Coordinated Active Levitation Control of Linear Permanent Magnet Motor Considering Mover Air-Gap Offset
This paper proposes an active levitation control method with double-sided single-phase winding coordination for long primary permanent magnet linear motors. Unlike traditional two windings levitation control methods with thrust and levitation windings respectively, this approach only adopt one set of windings to realize the normal force and thrust decoupling regulations between each stator and mover simultaneously by removing the additional levitation windings. The electromagnetic thrust and normal force are theoretically analyzed and an accurate mathematical model containing the relationship between the air gap and the electromagnetic force is established. The decoupling relationship between the electromagnetic force and the current under the dq frame is determined. Based on this analysis, two sets of the double-sided single-set winding are driven independently, and the electromagnetic thrust and normal force of the mover are regulated coordinately to achieve the air-gap offset active levitation control. An experimental platform is constructed to assess the feasibility of the proposed active levitation control and evaluate the effectiveness of the designed control system.
- 21 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (3) , 6801-6811
Double-Sided Single-Set Winding Coordinated Active Levitation Control of Linear Permanent Magnet Motor Considering Mover Air-Gap Offset
This paper proposes an active levitation control method with double-sided single-phase winding coordination for long primary permanent magnet linear motors. Unlike traditional two windings levitation control methods with thrust and levitation windings respectively, this approach only adopt one set of windings to realize the normal force and thrust decoupling regulations between each stator and mover simultaneously by removing the additional levitation windings. The electromagnetic thrust and normal force are theoretically analyzed and an accurate mathematical model containing the relationship between the air gap and the electromagnetic force is established. The decoupling relationship between the electromagnetic force and the current under the dq frame is determined. Based on this analysis, two sets of the double-sided single-set winding are driven independently, and the electromagnetic thrust and normal force of the mover are regulated coordinately to achieve the air-gap offset active levitation control. An experimental platform is constructed to assess the feasibility of the proposed active levitation control and evaluate the effectiveness of the designed control system.
- 26 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (6) , 7226-7240
Analysis of Mechanical Stress and Vibration Reduction of High-Speed Linear Motors for Electromagnetic Launch System
This paper presents a structural strength analysis and noise reduction method for high-speed long primary moving-magnet-type linear synchronous motors (MMT-LSMs) applied to electromagnetic launch systems under high acceleration. The stresses and deformations of the mover and frame at different mover offset distances are analyzed and calculated to reveal that the permanent magnets (PMs) placed ectally on both sides of the mover core are easily damaged and need to be protected by sleeves. Then the mover stresses with different sleeve materials and varied PM-sleeve interference values are compared for subsequent optimization. Furthermore, tooth harmonic is the main causes of vibration and noise when electromagnetic force waves are exerted on this MMT-LSM. Three improved methods are discussed comprehensively to reduce vibration and noise, including pole/slot combination, slot width, and pole arc coefficient. Finally, the experiment platform is built with the implementation of the modal and vibration acceleration experiments to verify the proposed analysis method.
- 26 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (6) , 7226-7240
Analysis of Mechanical Stress and Vibration Reduction of High-Speed Linear Motors for Electromagnetic Launch System
This paper presents a structural strength analysis and noise reduction method for high-speed long primary moving-magnet-type linear synchronous motors (MMT-LSMs) applied to electromagnetic launch systems under high acceleration. The stresses and deformations of the mover and frame at different mover offset distances are analyzed and calculated to reveal that the permanent magnets (PMs) placed ectally on both sides of the mover core are easily damaged and need to be protected by sleeves. Then the mover stresses with different sleeve materials and varied PM-sleeve interference values are compared for subsequent optimization. Furthermore, tooth harmonic is the main causes of vibration and noise when electromagnetic force waves are exerted on this MMT-LSM. Three improved methods are discussed comprehensively to reduce vibration and noise, including pole/slot combination, slot width, and pole arc coefficient. Finally, the experiment platform is built with the implementation of the modal and vibration acceleration experiments to verify the proposed analysis method.
- 21 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 55 (6) , 1-5
Detent Force Minimizing for Moving-Magnet-Type Linear Synchronous Motor
This paper aims to reduce detent force (DF) of a moving-magnet-type linear synchronous motor by considering different permanent magnet (PM) widths and chamfer dimensions. DF is the main cause of thrust ripple, which can lead to worse operation performance. Through Fourier decomposition, it is found that the PM size is the key factor affecting DF significantly. The thrust and its ripple of different PM widths are obtained by using the finite-element analysis. After selecting the optimal PM width, considering the mechanical strength factor, the PM can be unavoidably chamfered, which further influences DF. Based on this, an optimized motor model is designed. The prototype is manufactured to verify its results.
- 21 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 55 (6) , 1-5
Detent Force Minimizing for Moving-Magnet-Type Linear Synchronous Motor
This paper aims to reduce detent force (DF) of a moving-magnet-type linear synchronous motor by considering different permanent magnet (PM) widths and chamfer dimensions. DF is the main cause of thrust ripple, which can lead to worse operation performance. Through Fourier decomposition, it is found that the PM size is the key factor affecting DF significantly. The thrust and its ripple of different PM widths are obtained by using the finite-element analysis. After selecting the optimal PM width, considering the mechanical strength factor, the PM can be unavoidably chamfered, which further influences DF. Based on this, an optimized motor model is designed. The prototype is manufactured to verify its results.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 01, 1044-1047
EMI analysis of hybrid HVDC breaker
Hybrid high voltage direct current (HVDC) breaker is one of the most important equipment in DC transmission networks. As it is known, the hybrid breaker consists of large numbers of power electronics devices and the nonlinear elements, so, during the fault occurrence there are many transients voltages and currents with sharp rate of (dv/dt, di/dt) resulting from switch-on and switch-off of transistors which may cause electromagnetic interference (EMI). The EMI not only affects hybrid breaker self-electronic system, but also affects the neighboring communication and control devices. In this paper the sources of EMI have been identified and the snubber circuit conducted EMI characteristics have been simulated under normal operation and fault occurrence using PSCAD/EMTDC software.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 01, 1044-1047
EMI analysis of hybrid HVDC breaker
Hybrid high voltage direct current (HVDC) breaker is one of the most important equipment in DC transmission networks. As it is known, the hybrid breaker consists of large numbers of power electronics devices and the nonlinear elements, so, during the fault occurrence there are many transients voltages and currents with sharp rate of (dv/dt, di/dt) resulting from switch-on and switch-off of transistors which may cause electromagnetic interference (EMI). The EMI not only affects hybrid breaker self-electronic system, but also affects the neighboring communication and control devices. In this paper the sources of EMI have been identified and the snubber circuit conducted EMI characteristics have been simulated under normal operation and fault occurrence using PSCAD/EMTDC software.
- 6 May 2013
- Published by Society of Petroleum Engineers (SPE)
Modular Stacked DC Transmission and Distribution System for Ultra-deepwater Subsea Process
The offshore oil and gas industry is developing subsea processing systems far away from the shore and in ultra-deepwater. These subsea systems are usually power intensive, and thus a reliable electrical transmission and distribution (T&D) system is desired. In this paper, the modular stacked direct current (MSDC) architecture is presented to meet the technical challenges of the ultra-deepwater subsea systems. Instead of using a bulky centralized high voltage direct current (HVDC) converter station, the high dc voltage is achieved by stacking a number of power converter building blocks in series on both the on-shore station and the seabed stations. The dc-link current is controlled to be constant, and the dc-link voltage will vary according to the loading condition. This architecture renders fault-tolerant capability and feasibility for field extension. The details for the system architecture, the control algorithm, the simulation and experimental results will be described. The test results and the studies show that the MSDC system is a very attractive solution for subsea applications. Introduction: The diminishing conventional oil and gas reservoirs and the always growing energy consumption have been driving the efforts to explore the deep-sea water petroleum resources, as shown in the diagram in Fig. 1. These resources are usually in ultra-deepwater and far away from the shore, where subsea process is usually preferred for technical and/or economic reasons. Subsea processing is especially attractive for the locations with tough topside environment since the manned topside platform can be removed. However, in order to achieve subsea process, turbo machines, e.g., pumps and compressors, and other processing equipment need to be deployed on the seabed. Accordingly various electrical equipment, including variable speed drives, power supplies, motors, connectors, switch gears, etc., are required to drive the machinery loads subsea. The overall power requirement ranges from tens of kW to tens of MW. As the scale and power consumption of the subsea process continue to grow, there is a clear need for a reliable power transmission and distribution system to power the subsea equipment over long step-out. Long step out distances and the ultra-deepwater environments have brought significant technical challenges to the electrical system. In ultra-deepwater and long step-out situation, accessibility of any equipment deployed in the subsea field is extremely limited. Subsea operation and maintenance is dependent on availability of vessels with remotely operated vehicles (ROV) and sufficient lifting/installation capacity, hence unplanned stops due to failures will cause large losses in production due to lost time. The cost of the vessel and offshore operation is also significant. Therefore, other than being designed for installation in ultra-deepwater, the electrical system must be very reliable and require minimum regular maintenance in its lifetime. The electrical system should also be as compact as possible and modularized, so that they can be installed and retrieved without heavy vessels and lifts which have very limited availability. In addition, the electrical system should be flexible and easy to be reconfigured since the power requirement, the tie-back length, and the number of loads will vary from site to site. And it should also have the flexibility for future expansion since additional field might be found in the adjacent area. In order to meet the above mentioned challenges and requirements, the MSDC architecture has been developed for the subsea power transmission and distribution with long step-out. This paper compares different technology options for subsea transmission and distribution (T&D), presents the MSDC architecture, describes the details of the system operation, and discusses the results of the field case simulation and the lab demo.
- 6 May 2013
- Published by Society of Petroleum Engineers (SPE)
Modular Stacked DC Transmission and Distribution System for Ultra-deepwater Subsea Process
The offshore oil and gas industry is developing subsea processing systems far away from the shore and in ultra-deepwater. These subsea systems are usually power intensive, and thus a reliable electrical transmission and distribution (T&D) system is desired. In this paper, the modular stacked direct current (MSDC) architecture is presented to meet the technical challenges of the ultra-deepwater subsea systems. Instead of using a bulky centralized high voltage direct current (HVDC) converter station, the high dc voltage is achieved by stacking a number of power converter building blocks in series on both the on-shore station and the seabed stations. The dc-link current is controlled to be constant, and the dc-link voltage will vary according to the loading condition. This architecture renders fault-tolerant capability and feasibility for field extension. The details for the system architecture, the control algorithm, the simulation and experimental results will be described. The test results and the studies show that the MSDC system is a very attractive solution for subsea applications. Introduction: The diminishing conventional oil and gas reservoirs and the always growing energy consumption have been driving the efforts to explore the deep-sea water petroleum resources, as shown in the diagram in Fig. 1. These resources are usually in ultra-deepwater and far away from the shore, where subsea process is usually preferred for technical and/or economic reasons. Subsea processing is especially attractive for the locations with tough topside environment since the manned topside platform can be removed. However, in order to achieve subsea process, turbo machines, e.g., pumps and compressors, and other processing equipment need to be deployed on the seabed. Accordingly various electrical equipment, including variable speed drives, power supplies, motors, connectors, switch gears, etc., are required to drive the machinery loads subsea. The overall power requirement ranges from tens of kW to tens of MW. As the scale and power consumption of the subsea process continue to grow, there is a clear need for a reliable power transmission and distribution system to power the subsea equipment over long step-out. Long step out distances and the ultra-deepwater environments have brought significant technical challenges to the electrical system. In ultra-deepwater and long step-out situation, accessibility of any equipment deployed in the subsea field is extremely limited. Subsea operation and maintenance is dependent on availability of vessels with remotely operated vehicles (ROV) and sufficient lifting/installation capacity, hence unplanned stops due to failures will cause large losses in production due to lost time. The cost of the vessel and offshore operation is also significant. Therefore, other than being designed for installation in ultra-deepwater, the electrical system must be very reliable and require minimum regular maintenance in its lifetime. The electrical system should also be as compact as possible and modularized, so that they can be installed and retrieved without heavy vessels and lifts which have very limited availability. In addition, the electrical system should be flexible and easy to be reconfigured since the power requirement, the tie-back length, and the number of loads will vary from site to site. And it should also have the flexibility for future expansion since additional field might be found in the adjacent area. In order to meet the above mentioned challenges and requirements, the MSDC architecture has been developed for the subsea power transmission and distribution with long step-out. This paper compares different technology options for subsea transmission and distribution (T&D), presents the MSDC architecture, describes the details of the system operation, and discusses the results of the field case simulation and the lab demo.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Industry Applications Annual Meeting
- Vol. 2 (01972618) , 873-879
Sliding Mode Sensorless Control of PM Synchronous Motor for Direct-Driven Washing Machines
The rotor position of PMSM is estimated by a novel sliding mode observer (SMO) operating over a wide speed range including deep flux-weakening region. By properly selecting equivalent control feedback gains, the estimation error of rotor position is reduced in low speeds and fast convergence of SMO guaranteed in high speeds. Compared to other PMSM systems for direct-driven washers using Hall effect sensors, the control scheme features high torque production and fast dynamic response, especially in the deep flux weakening high-speed range. The sensorless control algorithm is robust to the armature reaction that seriously affects Hall effect sensor signals and degrades torque production. The proposed sensorless control algorithm is verified by both computer simulation and experimental testing with a dynamometer as well as a direct-driven washer
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Industry Applications Annual Meeting
- Vol. 2 (01972618) , 873-879
Sliding Mode Sensorless Control of PM Synchronous Motor for Direct-Driven Washing Machines
The rotor position of PMSM is estimated by a novel sliding mode observer (SMO) operating over a wide speed range including deep flux-weakening region. By properly selecting equivalent control feedback gains, the estimation error of rotor position is reduced in low speeds and fast convergence of SMO guaranteed in high speeds. Compared to other PMSM systems for direct-driven washers using Hall effect sensors, the control scheme features high torque production and fast dynamic response, especially in the deep flux weakening high-speed range. The sensorless control algorithm is robust to the armature reaction that seriously affects Hall effect sensor signals and degrades torque production. The proposed sensorless control algorithm is verified by both computer simulation and experimental testing with a dynamometer as well as a direct-driven washer