Joy P. Dunkers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Joy P. Dunkers has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Marcus T. Cicerone
Department of Chemistry and Biochemistry Georgia Institute of Technology Atlanta Georgia USA
2 shared publications - Nancy J. Lin
Biomaterials Group, Biosystems and Biomaterials Division, National Institute of Standards and Technology, Gaithersburg, USA
2 shared publications - Sumona Sarkar
Department of Biomedical Engineering, Boston University, 44 Cummington Street, Boston, MA 02215, USA
2 shared publications A. Zheng
Precision Engineering Division, Manufacturing Engineering Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899
1 shared publication- Adele P. Peskin
National Institute of Standards and Technology
1 shared publication - Alshae' R. Logan-Jackson
Department of Microbiology and Molecular Genetics, Michigan State University, East Lansing, MI 48824, USA
1 shared publication
Latest Publications
- Open Access
- 20 October 2026
- Published by Elsevier in SSRN Electronic Journal
Decoupling Physicochemical and Chemical Interactions in Polymicrobial Nanocultures
Microbial interactions in polymicrobial communities are shaped by chemical signaling, environmental conditions, and spatial organization. The inherent coupling of these factors in conventional bulk cultures limits the quantitative investigation of microbial community dynamics. Here, we present nanocultures—PDMS-based microscale bioreactors—as a platform for decoupling physical and chemical perturbations within confined microbial communities. Using Pseudomonas aeruginosa and Staphylococcus aureus as a model polymicrobial system, we investigated microbial responses to osmotic stress and antagonistic metabolites, including pyocyanin, HQNO, and cell-free spent medium. By integrating confocal microscopy, deep learning-based image analysis, and isothermal microcalorimetry, we quantified microbial abundance, spatial organization, and metabolic activity under controlled microscale environments. While fluorescence measurements suggested greater S. aureus abundance under hypertonic conditions, AI-based cell counting overcame this limitation by directly quantifying species-specific abundance and revealing the competitive dominance of P. aeruginosa in co-culture. Furthermore, nanocultures enabled independent evaluation of chemically mediated inhibition, demonstrating that PDMS-permeable metabolites alone can suppress S. aureus growth in the absence of direct cell-cell contact. Together, these findings establish nanocultures as a quantitative microscale platform for investigating microbial interactions by integrating complementary measurements of microbial growth, spatial organization, and metabolic activity. Teaser Nanocultures: A Tool for Decoupling Polymicrobial Interactions.
- 20 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDecoupling Physicochemical and Chemical Interactions in Polymicrobial Nanocultures
Microbial interactions in polymicrobial communities are shaped by chemical signaling, environmental conditions, and spatial organization. The inherent coupling of these factors in conventional bulk cultures limits the quantitative investigation of microbial community dynamics. Here, we present nanocultures—PDMS-based microscale bioreactors—as a platform for decoupling physical and chemical perturbations within confined microbial communities. Using Pseudomonas aeruginosa and Staphylococcus aureus as a model polymicrobial system, we investigated microbial responses to osmotic stress and antagonistic metabolites, including pyocyanin, HQNO, and cell-free spent medium. By integrating confocal microscopy, deep learning-based image analysis, and isothermal microcalorimetry, we quantified microbial abundance, spatial organization, and metabolic activity under controlled microscale environments. While fluorescence measurements suggested greater S. aureus abundance under hypertonic conditions, AI-based cell counting overcame this limitation by directly quantifying species-specific abundance and revealing the competitive dominance of P. aeruginosa in co-culture. Furthermore, nanocultures enabled independent evaluation of chemically mediated inhibition, demonstrating that PDMS-permeable metabolites alone can suppress S. aureus growth in the absence of direct cell-cell contact. Together, these findings establish nanocultures as a quantitative microscale platform for investigating microbial interactions by integrating complementary measurements of microbial growth, spatial organization, and metabolic activity. Teaser Nanocultures: A Tool for Decoupling Polymicrobial Interactions.
- Open Access
Measurement Quality Metrics to Improve Absolute Microbial Cell Counting
Total and viable microbial cell counts are increasingly important for applications including live biotherapeutic products, food safety, and probiotics. In microbiology, cells are quantified using methods such as colony forming unit (CFU), flow cytometry, and polymerase chain reaction (PCR), but different methods measure different aspects of the cells (measurands), and results may not be directly comparable across methods. In the absence of a ground-truth reference material for cell count, one cannot quantify the accuracy of any cell counting method, which limits method performance assessments and comparisons. Herein, a modified analysis of cell counting methods based on the ISO 20391-2:2019 standard was developed and demonstrated for microbial cell samples diluted over a log-scale range of concentrations. Escherichia coli samples ranging in concentration from approximately 5 × 10 5 cells/mL to 2 × 10 7 cells/mL were quantified using CFU, Coulter principle, fluorescence flow cytometry, and impedance flow cytometry. Quality metrics modified from the ISO standard were calculated for each method and shown to be repeatable across replicate experiments. The quality metrics illustrate large differences in proportionality and variability across methods, with total cell counts in good agreement and viable cell count having more variability. As the ISO standard is meant to guide fit-for-purpose method selection, interpretation of the results and quality metrics can drive method choice and optimization. The framework introduced here will help researchers select fit-for-purpose counting methods for quantification of microbial total and viable cells across a range of applications.
Open AccessMeasurement Quality Metrics to Improve Absolute Microbial Cell Counting
Total and viable microbial cell counts are increasingly important for applications including live biotherapeutic products, food safety, and probiotics. In microbiology, cells are quantified using methods such as colony forming unit (CFU), flow cytometry, and polymerase chain reaction (PCR), but different methods measure different aspects of the cells (measurands), and results may not be directly comparable across methods. In the absence of a ground-truth reference material for cell count, one cannot quantify the accuracy of any cell counting method, which limits method performance assessments and comparisons. Herein, a modified analysis of cell counting methods based on the ISO 20391-2:2019 standard was developed and demonstrated for microbial cell samples diluted over a log-scale range of concentrations. Escherichia coli samples ranging in concentration from approximately 5 × 10 5 cells/mL to 2 × 10 7 cells/mL were quantified using CFU, Coulter principle, fluorescence flow cytometry, and impedance flow cytometry. Quality metrics modified from the ISO standard were calculated for each method and shown to be repeatable across replicate experiments. The quality metrics illustrate large differences in proportionality and variability across methods, with total cell counts in good agreement and viable cell count having more variability. As the ISO standard is meant to guide fit-for-purpose method selection, interpretation of the results and quality metrics can drive method choice and optimization. The framework introduced here will help researchers select fit-for-purpose counting methods for quantification of microbial total and viable cells across a range of applications.
- 12 September 2021
- Published by Wiley in Journal of Biophotonics
- Vol. 14 (12) , e202100175
Toward absolute viability measurements for bacteria
We aim to develop a quantitative viability method that distinguishes individual quiescent from dead cells and is measured in time (ns) as a referenceable, comparable quantity. We demonstrate that fluorescence lifetime imaging of an anionic, fluorescent membrane voltage probe fulfills these requirements forStreptococcus mutans. A random forest machine‐learning model assesses whether individualS. mutanscan be correctly classified into their original populations: stationary phase (quiescent), heat killed and inactivated via chemical fixation. We compare the results to intensity using three models: lifetime variables (τ1, τ2and p1), phasor variables (G, S) or all five variables, with the five variable models having the most accurate classification. This initial work affirms the potential for using fluorescence lifetime of a membrane voltage probe as a viability marker for quiescent bacteria, and future efforts on other bacterial species and fluorophores will help refine this approach.
- 12 September 2021
- Published by Wiley in Journal of Biophotonics
- Vol. 14 (12) , e202100175
Toward absolute viability measurements for bacteria
We aim to develop a quantitative viability method that distinguishes individual quiescent from dead cells and is measured in time (ns) as a referenceable, comparable quantity. We demonstrate that fluorescence lifetime imaging of an anionic, fluorescent membrane voltage probe fulfills these requirements forStreptococcus mutans. A random forest machine‐learning model assesses whether individualS. mutanscan be correctly classified into their original populations: stationary phase (quiescent), heat killed and inactivated via chemical fixation. We compare the results to intensity using three models: lifetime variables (τ1, τ2and p1), phasor variables (G, S) or all five variables, with the five variable models having the most accurate classification. This initial work affirms the potential for using fluorescence lifetime of a membrane voltage probe as a viability marker for quiescent bacteria, and future efforts on other bacterial species and fluorophores will help refine this approach.
- 10 May 2019
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 15 (21) , 4284-4293
Structural insights into DNA-stabilized silver clusters
Despite their great promise as fluorescent biological probes and sensors, the structure and dynamics of Ag complexes derived from single stranded DNA (ssDNA) are less understood than their double stranded counterparts. In this work, we seek new insights into the structure of single AgNssDNA clusters using analytical ultracentrifugation (AUC), nuclear magnetic resonance spectroscopy, infrared spectroscopy and molecular dynamics simulations (MD) of a fluorescent (AgNssDNA)8+ nanocluster. The results suggest that the purified (AgNssDNA)8+ nanocluster is a mixture of predominantly Ag15 and Ag16 species that prefer two distinct long-lived conformational states: one extended, the other approaching spherical. However, the ssDNA strands within these clusters are highly mobile. Ag(I) interacts preferentially with the nucleobase rather than the phosphate backbone, causing a restructuring of the DNA strand relative to the bare DNA. Infrared spectroscopy and MD simulations of (AgNssDNA)8+ and model nucleic acid homopolymers suggest that Ag(I) has a higher affinity for cytosine over guanine bases, little interaction with adenine, and virtually none with thymine. Ag(I) shows a tendency to interact with cytosine N3 and O2 and guanine N7 and O6, opening the possibility for a Ag(I)–base bifurcated bond to act as a nanocluster nucleation and strand stabilizing site. This work provides valuable insight into nanocluster structure and dynamics which drive stability and optical properties, and additional studies using these types of characterization techniques are important for the rational design of single stranded AgDNA nanocluster sensors.
- 10 May 2019
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 15 (21) , 4284-4293
Structural insights into DNA-stabilized silver clusters
Despite their great promise as fluorescent biological probes and sensors, the structure and dynamics of Ag complexes derived from single stranded DNA (ssDNA) are less understood than their double stranded counterparts. In this work, we seek new insights into the structure of single AgNssDNA clusters using analytical ultracentrifugation (AUC), nuclear magnetic resonance spectroscopy, infrared spectroscopy and molecular dynamics simulations (MD) of a fluorescent (AgNssDNA)8+ nanocluster. The results suggest that the purified (AgNssDNA)8+ nanocluster is a mixture of predominantly Ag15 and Ag16 species that prefer two distinct long-lived conformational states: one extended, the other approaching spherical. However, the ssDNA strands within these clusters are highly mobile. Ag(I) interacts preferentially with the nucleobase rather than the phosphate backbone, causing a restructuring of the DNA strand relative to the bare DNA. Infrared spectroscopy and MD simulations of (AgNssDNA)8+ and model nucleic acid homopolymers suggest that Ag(I) has a higher affinity for cytosine over guanine bases, little interaction with adenine, and virtually none with thymine. Ag(I) shows a tendency to interact with cytosine N3 and O2 and guanine N7 and O6, opening the possibility for a Ag(I)–base bifurcated bond to act as a nanocluster nucleation and strand stabilizing site. This work provides valuable insight into nanocluster structure and dynamics which drive stability and optical properties, and additional studies using these types of characterization techniques are important for the rational design of single stranded AgDNA nanocluster sensors.
- 1 March 2012
- Published by Elsevier in Biomaterials
- Vol. 33 (7) , 2119-2126
Single cell viability measurements in 3D scaffolds using in situ label free imaging by optical coherence microscopy
- 1 March 2012
- Published by Elsevier in Biomaterials
- Vol. 33 (7) , 2119-2126
Single cell viability measurements in 3D scaffolds using in situ label free imaging by optical coherence microscopy
- 31 July 2011
- Published by Elsevier in Acta Biomaterialia
- Vol. 7 (7) , 2902-2909
Effect of surface modification on protein retention and cell proliferation under strain
- 31 July 2011
- Published by Elsevier in Acta Biomaterialia
- Vol. 7 (7) , 2902-2909
Effect of surface modification on protein retention and cell proliferation under strain
- 20 February 2009
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 92A (2) , 604-614
Evaluation of polydimethylsiloxane modification methods for cell response
Many methods exist in the literature to modify surfaces with extracellular matrix (ECM) proteins prior to cell seeding. However, there are few studies that systematically characterize and compare surface properties and cell response results among modification methods that use different bonding mechanisms. In this work, we compare cell response and physical characterization results from fibronectin or laminin attached to polydimethylsiloxane (PDMS) elastomer surfaces by physical adsorption, chemisorption, and covalent attachment to determine the best method to modify a deformable surface. We evaluate modification methods based on completeness and uniformity of coverage, surface roughness, and hydrophilicity of attached ECM protein. Smooth muscle cell adhesion, proliferation, morphology, and phenotype were also evaluated. We found that chemisorption methods resulted in higher amounts of protein attachment than physical adsorption and covalent bonding of the ECM proteins. Cell response to protein‐modified surfaces was similar with respect to cell adhesion, area, aspect ratio, and phenotype. When all the data are considered, the chemisorption methods, most notably silane_70, provide the best surface properties and highest cell proliferation. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res, 2010
- 20 February 2009
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 92A (2) , 604-614
Evaluation of polydimethylsiloxane modification methods for cell response
Many methods exist in the literature to modify surfaces with extracellular matrix (ECM) proteins prior to cell seeding. However, there are few studies that systematically characterize and compare surface properties and cell response results among modification methods that use different bonding mechanisms. In this work, we compare cell response and physical characterization results from fibronectin or laminin attached to polydimethylsiloxane (PDMS) elastomer surfaces by physical adsorption, chemisorption, and covalent attachment to determine the best method to modify a deformable surface. We evaluate modification methods based on completeness and uniformity of coverage, surface roughness, and hydrophilicity of attached ECM protein. Smooth muscle cell adhesion, proliferation, morphology, and phenotype were also evaluated. We found that chemisorption methods resulted in higher amounts of protein attachment than physical adsorption and covalent bonding of the ECM proteins. Cell response to protein‐modified surfaces was similar with respect to cell adhesion, area, aspect ratio, and phenotype. When all the data are considered, the chemisorption methods, most notably silane_70, provide the best surface properties and highest cell proliferation. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res, 2010
- 1 September 2007
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 112 (5) , 257-70
Measurement tools for the immersive visualization environment: Steps toward the virtual laboratory
This paper describes a set of tools for performing measurements of objects in a virtual reality based immersive visualization environment. These tools enable the use of the immersive environment as an instrument for extracting quantitative information from data representations that hitherto had be used solely for qualitative examination. We provide, within the virtual environment, ways for the user to analyze and interact with the quantitative data generated. We describe results generated by these methods to obtain dimensional descriptors of tissue engineered medical products. We regard this toolbox as our first step in the implementation of a virtual measurement laboratory within an immersive visualization environment.
- 1 September 2007
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 112 (5) , 257-70
Measurement tools for the immersive visualization environment: Steps toward the virtual laboratory
This paper describes a set of tools for performing measurements of objects in a virtual reality based immersive visualization environment. These tools enable the use of the immersive environment as an instrument for extracting quantitative information from data representations that hitherto had be used solely for qualitative examination. We provide, within the virtual environment, ways for the user to analyze and interact with the quantitative data generated. We describe results generated by these methods to obtain dimensional descriptors of tissue engineered medical products. We regard this toolbox as our first step in the implementation of a virtual measurement laboratory within an immersive visualization environment.
- 24 May 2007
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 97 (4) , 952-961
Perfusion flow bioreactor for 3D in situ imaging: Investigating cell/biomaterials interactions
The capability to image real time cell/material interactions in a three‐dimensional (3D) culture environment will aid in the advancement of tissue engineering. This paper describes a perfusion flow bioreactor designed to hold tissue engineering scaffolds and allow for in situ imaging using an upright microscope. The bioreactor can hold a scaffold of desirable thickness for implantation (>2 mm). Coupling 3D culture and perfusion flow leads to the creation of a more biomimetic environment. We examined the ability of the bioreactor to maintain cell viability outside of an incubator environment (temperature and pH stability), investigated the flow features of the system (flow induced shear stress), and determined the image quality in order to perform time‐lapsed imaging of two‐dimensional (2D) and 3D cell culture. In situ imaging was performed on 2D and 3D, culture samples and cell viability was measured under perfusion flow (2.5 mL/min, 0.016 Pa). The visualization of cell response to their environment, in real time, will help to further elucidate the influences of biomaterial surface features, scaffold architectures, and the influence of flow induced shear on cell response and growth of new tissue. Biotechnol. Bioeng. 2007;97: 952–961.
- 24 May 2007
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 97 (4) , 952-961
Perfusion flow bioreactor for 3D in situ imaging: Investigating cell/biomaterials interactions
The capability to image real time cell/material interactions in a three‐dimensional (3D) culture environment will aid in the advancement of tissue engineering. This paper describes a perfusion flow bioreactor designed to hold tissue engineering scaffolds and allow for in situ imaging using an upright microscope. The bioreactor can hold a scaffold of desirable thickness for implantation (>2 mm). Coupling 3D culture and perfusion flow leads to the creation of a more biomimetic environment. We examined the ability of the bioreactor to maintain cell viability outside of an incubator environment (temperature and pH stability), investigated the flow features of the system (flow induced shear stress), and determined the image quality in order to perform time‐lapsed imaging of two‐dimensional (2D) and 3D cell culture. In situ imaging was performed on 2D and 3D, culture samples and cell viability was measured under perfusion flow (2.5 mL/min, 0.016 Pa). The visualization of cell response to their environment, in real time, will help to further elucidate the influences of biomaterial surface features, scaffold architectures, and the influence of flow induced shear on cell response and growth of new tissue. Biotechnol. Bioeng. 2007;97: 952–961.