Niels Søgaard Jensen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Niels Søgaard Jensen has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Claus Nielsen
Oticon, Research Centre Eriksholm, Denmark
3 shared publicationsPatrick Maas
Oticon, Research Centre Eriksholm, Denmark
3 shared publicationsSøren Laugesen
Eriksholm Research Centre, Oticon A/S, Snekkersten, Denmark
3 shared publications- Graham Naylor
Hearing Sciences, Mental Health and Clinical Neurosciences, School of Medicine, University of Nottingham, Nottingham, UK
2 shared publications Louise Kragelund
Eriksholm Research Centre, Oticon A/S, Snekkersten, Denmark
2 shared publications- Michael A. Akeroyd
University of Nottingham
2 shared publications
Latest Publications
- Open Access
- 1 January 2019
- Published by SAGE Publications in Trends in Hearing
- Vol. 23
Perceptual Effects of Adjusting Hearing-Aid Gain by Means of a Machine-Learning Approach Based on Individual User Preference
This study investigated a method to adjust hearing-aid gain by use of a machine-learning algorithm that estimates the optimal setting of gain parameters based on user preference indicated in an iterative paired-comparison procedure. Twenty hearing-impaired participants completed this procedure for 12 different sound scenarios. During the adjustment procedure, their task was to indicate a preference based on one of three sound attributes: Basic Audio Quality, Listening Comfort, or Speech Clarity. In a double-blind comparison of recordings of the processed scenarios, and using the same attributes as criteria, the adjusted gain settings were subsequently compared with two prescribed settings of the same hearing aid (with and without activation of an automatic sound-classification system). The results showed that the adjustment method provided a general improvement of Basic Audio Quality, an improvement of Listening Comfort in a traffic-noise scenario but not in three scenarios with speech babble, and no significant improvement of Speech Clarity. A large variation in gain adjustments was observed across participants, both among those who did benefit and among those who did not benefit from the adjustment. There was no clear connection between the gain adjustments and the perceived benefit, which indicates that the preferred gain settings for a given sound scenario and a given listening intention are highly individual and difficult to predict.
- 1 January 2019
- Published by SAGE Publications in Trends in Hearing
- Vol. 23
Open AccessPerceptual Effects of Adjusting Hearing-Aid Gain by Means of a Machine-Learning Approach Based on Individual User Preference
This study investigated a method to adjust hearing-aid gain by use of a machine-learning algorithm that estimates the optimal setting of gain parameters based on user preference indicated in an iterative paired-comparison procedure. Twenty hearing-impaired participants completed this procedure for 12 different sound scenarios. During the adjustment procedure, their task was to indicate a preference based on one of three sound attributes: Basic Audio Quality, Listening Comfort, or Speech Clarity. In a double-blind comparison of recordings of the processed scenarios, and using the same attributes as criteria, the adjusted gain settings were subsequently compared with two prescribed settings of the same hearing aid (with and without activation of an automatic sound-classification system). The results showed that the adjustment method provided a general improvement of Basic Audio Quality, an improvement of Listening Comfort in a traffic-noise scenario but not in three scenarios with speech babble, and no significant improvement of Speech Clarity. A large variation in gain adjustments was observed across participants, both among those who did benefit and among those who did not benefit from the adjustment. There was no clear connection between the gain adjustments and the perceived benefit, which indicates that the preferred gain settings for a given sound scenario and a given listening intention are highly individual and difficult to predict.
- 14 March 2017
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 56 (8) , 559-567
Selection of test-setup parameters to target specific signal-to-noise regions in speech-on-speech intelligibility testing
Objective: To investigate the magnitude of the change in speech-reception threshold (SRT) provided by altering four different test-setup parameters. Furthermore, to determine whether these changes in SRT are of a sufficient magnitude, such that they can be used to design a test-setup in future experiments that target a predefined signal-to-noise ratio (SNR) region. This could be particularly important if the test contrast investigated is confounded with test SNR. Design: The investigated test-setup parameters were: Spatial separation between target (0°) and maskers (±15°, ±30°, ±45°, or ±75°), number of maskers (two, four or six), scoring method (scoring percent-correct words or sentences) and masker gender (same or opposite to target). Twenty SRTs were measured per test subject. Study sample: Twenty hearing-impaired test subjects participated over two visits. Results: Alteration of masker gender, spatial separation between target and masker (±15°, ±30°, ± 45°), and scoring method was shown to offer SRT changes of a sufficient magnitude. The different test setups resulted in average SRTs ranging from −4.0 to 3.3 dB. Conclusion: Deliberately selecting test setup parameters can change the overall difficulty of the test by up to 7.3 dB SRT. Thus, a future experiment can, to this extent, be designed to target a specific SNR region.
- 14 March 2017
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 56 (8) , 559-567
Selection of test-setup parameters to target specific signal-to-noise regions in speech-on-speech intelligibility testing
Objective: To investigate the magnitude of the change in speech-reception threshold (SRT) provided by altering four different test-setup parameters. Furthermore, to determine whether these changes in SRT are of a sufficient magnitude, such that they can be used to design a test-setup in future experiments that target a predefined signal-to-noise ratio (SNR) region. This could be particularly important if the test contrast investigated is confounded with test SNR. Design: The investigated test-setup parameters were: Spatial separation between target (0°) and maskers (±15°, ±30°, ±45°, or ±75°), number of maskers (two, four or six), scoring method (scoring percent-correct words or sentences) and masker gender (same or opposite to target). Twenty SRTs were measured per test subject. Study sample: Twenty hearing-impaired test subjects participated over two visits. Results: Alteration of masker gender, spatial separation between target and masker (±15°, ±30°, ± 45°), and scoring method was shown to offer SRT changes of a sufficient magnitude. The different test setups resulted in average SRTs ranging from −4.0 to 3.3 dB. Conclusion: Deliberately selecting test setup parameters can change the overall difficulty of the test by up to 7.3 dB SRT. Thus, a future experiment can, to this extent, be designed to target a specific SNR region.
- Open Access
- 1 September 2013
- Published by SAGE Publications in Trends in Amplification
- Vol. 17 (3) , 171-188
Laboratory and Field Study of the Potential Benefits of Pinna Cue-Preserving Hearing Aids
The potential benefits of preserving high-frequency spectral cues created by the pinna in hearing-aid fittings were investigated in a combined laboratory and field test. In a single-blind crossover design, two settings of an experimental hearing aid were compared. One setting was characterized by a pinna cue-preserving microphone position, whereas the other was characterized by a microphone position not preserving pinna cues. Participants were allowed 1 month of acclimatization to each setting before measurements of localization and spatial release from speech-on-speech masking were completed in the laboratory. Real-world experience with the two settings was assessed by means of questionnaires. Seventeen participants with mild to moderate sensorineural hearing impairments completed the study. An inconsistent pinna cue benefit pattern was observed across the outcome measures. In the localization test, the pinna cue-preserving setting provided a significant mean reduction of 22° in the root mean square (RMS) error in the front–back dimension, with 13 of the 17 participants showing a reduction of at least 15°. No significant mean difference in RMS error between settings was observed in the left–right dimension. No significant differences between settings were observed in the spatial-unmasking test conditions. The questionnaire data indicated a small, but nonsignificant, benefit of the pinna cue-preserving setting in certain real-life situations, which corresponded with a general preference for that setting. No significant real-life localization benefit was observed. The results suggest that preserving pinna cues can offer benefit in some conditions for individual hearing-aid users with mild to moderate hearing loss and is unlikely to harm performances for the rest.
- 1 September 2013
- Published by SAGE Publications in Trends in Amplification
- Vol. 17 (3) , 171-188
Open AccessLaboratory and Field Study of the Potential Benefits of Pinna Cue-Preserving Hearing Aids
The potential benefits of preserving high-frequency spectral cues created by the pinna in hearing-aid fittings were investigated in a combined laboratory and field test. In a single-blind crossover design, two settings of an experimental hearing aid were compared. One setting was characterized by a pinna cue-preserving microphone position, whereas the other was characterized by a microphone position not preserving pinna cues. Participants were allowed 1 month of acclimatization to each setting before measurements of localization and spatial release from speech-on-speech masking were completed in the laboratory. Real-world experience with the two settings was assessed by means of questionnaires. Seventeen participants with mild to moderate sensorineural hearing impairments completed the study. An inconsistent pinna cue benefit pattern was observed across the outcome measures. In the localization test, the pinna cue-preserving setting provided a significant mean reduction of 22° in the root mean square (RMS) error in the front–back dimension, with 13 of the 17 participants showing a reduction of at least 15°. No significant mean difference in RMS error between settings was observed in the left–right dimension. No significant differences between settings were observed in the spatial-unmasking test conditions. The questionnaire data indicated a small, but nonsignificant, benefit of the pinna cue-preserving setting in certain real-life situations, which corresponded with a general preference for that setting. No significant real-life localization benefit was observed. The results suggest that preserving pinna cues can offer benefit in some conditions for individual hearing-aid users with mild to moderate hearing loss and is unlikely to harm performances for the rest.
- Top Cited Papers
- 18 April 2013
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 52 (6) , 409-412
A short form of the Speech, Spatial and Qualities of Hearing scale suitable for clinical use: The SSQ12
Objective: To develop and evaluate a 12-item version of the Speech, Spatial and Qualities of Hearing scale for use in clinical research and rehabilitation settings, and provide a formula for converting scores between the full (SSQ49) and abbreviated (SSQ12) versions. Design: Items were selected independently at the three centres (Eriksholm Research Centre, MRC Institute of Hearing Research, University of New England) to be representative of the complete scale. A consensus was achieved after discussion. Study sample: The data set (n = 1220) used for a factor analysis (, submitted) was re-analysed to compare original SSQ scores (SSQ49) with scores on the short version (SSQ12). Results: A scatter-plot of SSQ12 scores against SSQ49 scores showed that SSQ12 score was about 0.6 of a scale point lower than the SSQ49 (0–10 scale) in the re-analysis of the Akeroyd et al data. SSQ12 scores lay on a slightly steeper slope than scores on the SSQ49. Conclusions: The SSQ12 provides similar results to SSQ49 in a large clinical research sample. The slightly lower average SSQ12 score and the slightly steeper slope reflect the composition of this short form relative to the SSQ49.
- 18 April 2013
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 52 (6) , 409-412
Top Cited PapersA short form of the Speech, Spatial and Qualities of Hearing scale suitable for clinical use: The SSQ12
Objective: To develop and evaluate a 12-item version of the Speech, Spatial and Qualities of Hearing scale for use in clinical research and rehabilitation settings, and provide a formula for converting scores between the full (SSQ49) and abbreviated (SSQ12) versions. Design: Items were selected independently at the three centres (Eriksholm Research Centre, MRC Institute of Hearing Research, University of New England) to be representative of the complete scale. A consensus was achieved after discussion. Study sample: The data set (n = 1220) used for a factor analysis (, submitted) was re-analysed to compare original SSQ scores (SSQ49) with scores on the short version (SSQ12). Results: A scatter-plot of SSQ12 scores against SSQ49 scores showed that SSQ12 score was about 0.6 of a scale point lower than the SSQ49 (0–10 scale) in the re-analysis of the Akeroyd et al data. SSQ12 scores lay on a slightly steeper slope than scores on the SSQ49. Conclusions: The SSQ12 provides similar results to SSQ49 in a large clinical research sample. The slightly lower average SSQ12 score and the slightly steeper slope reflect the composition of this short form relative to the SSQ49.
- 1 January 2013
- Published by American Psychological Association (APA)
Speech, Spatial and Qualities of Hearing Scale-12
- 1 January 2013
- Published by American Psychological Association (APA)
Speech, Spatial and Qualities of Hearing Scale-12
- 1 September 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 130 (3) , 1542-1558
Can basic auditory and cognitive measures predict hearing-impaired listeners’ localization and spatial speech recognition abilities?
This study aimed to clarify the basic auditory and cognitive processes that affect listeners' performance on two spatial listening tasks: sound localization and speech recognition in spatially complex, multi-talker situations. Twenty-three elderly listeners with mild-to-moderate sensorineural hearing impairments were tested on the two spatial listening tasks, a measure of monaural spectral ripple discrimination, a measure of binaural temporal fine structure (TFS) sensitivity, and two (visual) cognitive measures indexing working memory and attention. All auditory test stimuli were spectrally shaped to restore (partial) audibility for each listener on each listening task. Eight younger normal-hearing listeners served as a control group. Data analyses revealed that the chosen auditory and cognitive measures could predict neither sound localization accuracy nor speech recognition when the target and maskers were separated along the front-back dimension. When the competing talkers were separated along the left-right dimension, however, speech recognition performance was significantly correlated with the attentional measure. Furthermore, supplementary analyses indicated additional effects of binaural TFS sensitivity and average low-frequency hearing thresholds. Altogether, these results are in support of the notion that both bottom-up and top-down deficits are responsible for the impaired functioning of elderly hearing-impaired listeners in cocktail party-like situations.
- 1 September 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 130 (3) , 1542-1558
Can basic auditory and cognitive measures predict hearing-impaired listeners’ localization and spatial speech recognition abilities?
This study aimed to clarify the basic auditory and cognitive processes that affect listeners' performance on two spatial listening tasks: sound localization and speech recognition in spatially complex, multi-talker situations. Twenty-three elderly listeners with mild-to-moderate sensorineural hearing impairments were tested on the two spatial listening tasks, a measure of monaural spectral ripple discrimination, a measure of binaural temporal fine structure (TFS) sensitivity, and two (visual) cognitive measures indexing working memory and attention. All auditory test stimuli were spectrally shaped to restore (partial) audibility for each listener on each listening task. Eight younger normal-hearing listeners served as a control group. Data analyses revealed that the chosen auditory and cognitive measures could predict neither sound localization accuracy nor speech recognition when the target and maskers were separated along the front-back dimension. When the competing talkers were separated along the left-right dimension, however, speech recognition performance was significantly correlated with the attentional measure. Furthermore, supplementary analyses indicated additional effects of binaural TFS sensitivity and average low-frequency hearing thresholds. Altogether, these results are in support of the notion that both bottom-up and top-down deficits are responsible for the impaired functioning of elderly hearing-impaired listeners in cocktail party-like situations.
- 28 January 2011
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 50 (4) , 226-236
Own voice qualities (OVQ) in hearing-aid users: There is more than just occlusion
Objective: Hearing-aid users’ problems with their own voice caused by occlusion are well known. Conversely, it remains essentially undocumented whether hearing-aid users expected not to have occlusion-related problems experience own-voice issues. Design: To investigate this topic, a dedicated Own Voice Qualities (OVQ) questionnaire was developed and used in two experiments with stratified samples. Study sample: In the main experiment, the OVQ was administered to 169 hearing-aid users (most of whom were expected not to have occlusion-related problems) and to a control group of 56 normally-hearing people. In the follow-up experiment, the OVQ was used in a cross-over study where 43 hearing-aid users rated own voice for an open fitting and a small-vent earmould fitting. Results: The results from the main experiment show that hearing-aid users (without occlusion) have more problems than the normal-hearing controls on several dimensions of own voice. The magnitude of these differences was found to be generally larger than the differences observed between the open fitting and the small-vent fitting in the follow-up experiment. Conclusions: This suggests that own voice is a potentially important concern, even for hearing-aid users who are not expected to have occlusion-related problems. Sumario Objetivo: Son bien conocidos los problemas que tienen los usuarios de auxiliares auditivos con su propia voz, causada por la oclusión. Por el contrario, ha permanecido esencialmente indocumentado, si los usuarios de auxiliares auditivos que no tienen problemas relacionados con la oclusión, experimentan estos problemas con su propia voz. Diseño: Para investigar este tema, se desarrolló un cuestionario de Cualidades de la Propia Voz (OVQ) y se usó en dos experimentos con muestras estratificadas. Muestra de Estudio: En el experimento principal, el OVQ se presentó a 169 usuarios de auxiliares auditivos (la mayoría de los cuales se esperaba no tuviera problemas relacionados con la oclusión) y a un grupo control de 56 normo-oyentes. En el experimento de seguimiento, el OVQ se usó en un estudio cruzado en el que 43 usuarios de auxiliares auditivos clasificaron sus voces a partir de una adaptación abierta y una con molde de baja ventilación. Resultados: Los resultados del experimento principal muestran que los usuarios de auxiliares auditivos (sin oclusión) tienen más problemas que los normo-oyentes del grupo control, en algunos parámetros de su propia voz. Se encontró que la magnitud de estas diferencias fue generalmente mayor que las observadas entre la adaptación abierta y la de baja ventilación, en el experimento de seguimiento. Conclusiones: Esto sugiere que la propia voz es un tema potencialmente importante incluso para usuarios de auxiliares auditivos en quienes no se espera que tengan problemas relacionados con la oclusión.
- 28 January 2011
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 50 (4) , 226-236
Own voice qualities (OVQ) in hearing-aid users: There is more than just occlusion
Objective: Hearing-aid users’ problems with their own voice caused by occlusion are well known. Conversely, it remains essentially undocumented whether hearing-aid users expected not to have occlusion-related problems experience own-voice issues. Design: To investigate this topic, a dedicated Own Voice Qualities (OVQ) questionnaire was developed and used in two experiments with stratified samples. Study sample: In the main experiment, the OVQ was administered to 169 hearing-aid users (most of whom were expected not to have occlusion-related problems) and to a control group of 56 normally-hearing people. In the follow-up experiment, the OVQ was used in a cross-over study where 43 hearing-aid users rated own voice for an open fitting and a small-vent earmould fitting. Results: The results from the main experiment show that hearing-aid users (without occlusion) have more problems than the normal-hearing controls on several dimensions of own voice. The magnitude of these differences was found to be generally larger than the differences observed between the open fitting and the small-vent fitting in the follow-up experiment. Conclusions: This suggests that own voice is a potentially important concern, even for hearing-aid users who are not expected to have occlusion-related problems. Sumario Objetivo: Son bien conocidos los problemas que tienen los usuarios de auxiliares auditivos con su propia voz, causada por la oclusión. Por el contrario, ha permanecido esencialmente indocumentado, si los usuarios de auxiliares auditivos que no tienen problemas relacionados con la oclusión, experimentan estos problemas con su propia voz. Diseño: Para investigar este tema, se desarrolló un cuestionario de Cualidades de la Propia Voz (OVQ) y se usó en dos experimentos con muestras estratificadas. Muestra de Estudio: En el experimento principal, el OVQ se presentó a 169 usuarios de auxiliares auditivos (la mayoría de los cuales se esperaba no tuviera problemas relacionados con la oclusión) y a un grupo control de 56 normo-oyentes. En el experimento de seguimiento, el OVQ se usó en un estudio cruzado en el que 43 usuarios de auxiliares auditivos clasificaron sus voces a partir de una adaptación abierta y una con molde de baja ventilación. Resultados: Los resultados del experimento principal muestran que los usuarios de auxiliares auditivos (sin oclusión) tienen más problemas que los normo-oyentes del grupo control, en algunos parámetros de su propia voz. Se encontró que la magnitud de estas diferencias fue generalmente mayor que las observadas entre la adaptación abierta y la de baja ventilación, en el experimento de seguimiento. Conclusiones: Esto sugiere que la propia voz es un tema potencialmente importante incluso para usuarios de auxiliares auditivos en quienes no se espera que tengan problemas relacionados con la oclusión.
- 1 January 2011
- Published by American Psychological Association (APA)
Own Voice Qualities Questionnaire
- 1 January 2011
- Published by American Psychological Association (APA)
Own Voice Qualities Questionnaire
- 1 September 2009
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 20 (8) , 503-513
Observations on Hearing Aid Users' Strategies for Controlling the Level of Their Own Voice
Background: Evidence suggests that hearing-aid users have difficulties with own-voice level control, most likely because their auditory feedback is affected by hearing-aid amplification. Purpose: The purpose of this study was to investigate how changes to auditory feedback affect the voice level of hearing-aid users. Research Design: A correlational study was set up to investigate the relation between voice level and hearing-aid amplification. Study Sample: Seven hearing-impaired speakers participated. All were experienced hearing-aid users. Data Collection and Analysis: The speakers projected their voice to a passive listener across different speaker-listener distances and with different prescriptions of gain in an experimental hearing aid. For each combination of conditions, produced voice level and self-perceived voice level was measured. These data were subjected to an analysis of variance assuming a mixture of random and fixed effects. In addition, all speakers took part in interviews. Results: Three speakers reacted to the changes in auditory feedback in agreement with previous experiments with normal-hearing speakers: they compensated by changing produced voice level. In contrast, the voice levels in the other four speakers were largely unaffected by the changes to auditory feedback. A secondary observation was that while all speakers increased their voice level with distance, the two subgroups produced different growth rates of vocal level versus distance. Conclusions: It is hypothesized that the speakers in the former subgroup relied on auditory feedback for solving the experimental task, whereas the latter subgroup had developed an own-voice level-control strategy based on proprioceptory feedback, possibly because they have lost faith in their auditory feedback mechanism, which indeed is changed by both hearing loss and hearing-aid amplification. Comparison to “target” voice levels suggests that proprioceptory feedback is less effective than auditory feedback for achieving adequate level-distance growth rate.
- 1 September 2009
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 20 (8) , 503-513
Observations on Hearing Aid Users' Strategies for Controlling the Level of Their Own Voice
Background: Evidence suggests that hearing-aid users have difficulties with own-voice level control, most likely because their auditory feedback is affected by hearing-aid amplification. Purpose: The purpose of this study was to investigate how changes to auditory feedback affect the voice level of hearing-aid users. Research Design: A correlational study was set up to investigate the relation between voice level and hearing-aid amplification. Study Sample: Seven hearing-impaired speakers participated. All were experienced hearing-aid users. Data Collection and Analysis: The speakers projected their voice to a passive listener across different speaker-listener distances and with different prescriptions of gain in an experimental hearing aid. For each combination of conditions, produced voice level and self-perceived voice level was measured. These data were subjected to an analysis of variance assuming a mixture of random and fixed effects. In addition, all speakers took part in interviews. Results: Three speakers reacted to the changes in auditory feedback in agreement with previous experiments with normal-hearing speakers: they compensated by changing produced voice level. In contrast, the voice levels in the other four speakers were largely unaffected by the changes to auditory feedback. A secondary observation was that while all speakers increased their voice level with distance, the two subgroups produced different growth rates of vocal level versus distance. Conclusions: It is hypothesized that the speakers in the former subgroup relied on auditory feedback for solving the experimental task, whereas the latter subgroup had developed an own-voice level-control strategy based on proprioceptory feedback, possibly because they have lost faith in their auditory feedback mechanism, which indeed is changed by both hearing loss and hearing-aid amplification. Comparison to “target” voice levels suggests that proprioceptory feedback is less effective than auditory feedback for achieving adequate level-distance growth rate.