ICItthi Chatnuntawech

Itthi Chatnuntawech

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Itthi Chatnuntawech has a total of 35 co-authors. Here are the top co-authors by number of shared publications:

  • Kawin Setsompop

    Department of Radiology A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital Charlestown Massachusetts USA

    3 shared publications
  • Berkin Bilgic

    Department of Radiology A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital Charlestown Massachusetts USA

    2 shared publications
  • Berkin Bilgic

    Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States

    2 shared publications
  • Lawrence L. Wald

    Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, Massachusetts

    2 shared publications
  • Mary Kate Manhard

    Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, Massachusetts

    2 shared publications
  • Qiyuan Tian

    Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, Massachusetts

    2 shared publications

Latest Publications

  • Data Augmentation for EEG Motor Imagery Classification Using Diffusion Model

    by Nutapol Soingern, Akraradet Sinsamersuk, Itthi Chatnuntawech, Chaklam Silpasuwanchai


  • Open Access

    Attentive pairwise interaction network for AI-assisted clock drawing test assessment of early visuospatial deficits

    by Raksit Raksasat, Surat Teerapittayanon, Sirawaj Itthipuripat, Kearkiat Praditpornsilpa, Aisawan Petchlorlian, Thiparat Chotibut, Chaipat Chunharas, Itthi Chatnuntawech

    Dementia is a debilitating neurological condition which impairs the cognitive function and the ability to take care of oneself. The Clock Drawing Test (CDT) is widely used to detect dementia, but differentiating normal from borderline cases requires years of clinical experience. Misclassifying mild abnormal as normal will delay the chance to investigate for potential reversible causes or slow down the progression. To help address this issue, we propose an automatic CDT scoring system that adopts Attentive Pairwise Interaction Network (API-Net), a fine-grained deep learning model that is designed to distinguish visually similar images. Inspired by how humans often learn to recognize different objects by looking at two images side-by-side, API-Net is optimized using image pairs in a contrastive manner, as opposed to standard supervised learning, which optimizes a model using individual images. In this study, we extend API-Net to infer Shulman CDT scores from a dataset of 3108 subjects. We compare the performance of API-Net to that of convolutional neural networks: VGG16, ResNet-152, and DenseNet-121. The best API-Net achieves an F1-score of 0.79, which is a 3% absolute improvement over ResNet-152’s F1-score of 0.76. The code for API-Net and the dataset used have been made available at https://github.com/cccnlab/CDT-API-Network.


  • Open Access

    Wave-Encoded Model-Based Deep Learning for Highly Accelerated Imaging with Joint Reconstruction

    by Jaejin Cho, Borjan Gagoski, Tae Hyung Kim, Qiyuan Tian, Robert Frost, Itthi Chatnuntawech, Berkin Bilgic

    A recently introduced model-based deep learning (MoDL) technique successfully incorporates convolutional neural network (CNN)-based regularizers into physics-based parallel imaging reconstruction using a small number of network parameters. Wave-controlled aliasing in parallel imaging (CAIPI) is an emerging parallel imaging method that accelerates imaging acquisition by employing sinusoidal gradients in the phase- and slice/partition-encoding directions during the readout to take better advantage of 3D coil sensitivity profiles. We propose wave-encoded MoDL (wave-MoDL) combining the wave-encoding strategy with unrolled network constraints for highly accelerated 3D imaging while enforcing data consistency. We extend wave-MoDL to reconstruct multicontrast data with CAIPI sampling patterns to leverage similarity between multiple images to improve the reconstruction quality. We further exploit this to enable rapid quantitative imaging using an interleaved look-locker acquisition sequence with T2 preparation pulse (3D-QALAS). Wave-MoDL enables a 40 s MPRAGE acquisition at 1 mm resolution at 16-fold acceleration. For quantitative imaging, wave-MoDL permits a 1:50 min acquisition for T1, T2, and proton density mapping at 1 mm resolution at 12-fold acceleration, from which contrast-weighted images can be synthesized as well. In conclusion, wave-MoDL allows rapid MR acquisition and high-fidelity image reconstruction and may facilitate clinical and neuroscientific applications by incorporating unrolled neural networks into wave-CAIPI reconstruction.


  • Nonlinear dipole inversion (NDI) enables robust quantitative susceptibility mapping (QSM)

    by Daniel Polak, Itthi Chatnuntawech, Jaeyeon Yoon, Siddharth Srinivasan Iyer, Carlos Milovic, Jongho Lee, Peter Bachert, Elfar Adalsteinsson, Kawin Setsompop, Berkin Bilgic

    High‐quality Quantitative Susceptibility Mapping (QSM) with Nonlinear Dipole Inversion (NDI) is developed with pre‐determined regularization while matching the image quality of state‐of‐the‐art reconstruction techniques and avoiding over‐smoothing that these techniques often suffer from. NDI is flexible enough to allow for reconstruction from an arbitrary number of head orientations and outperforms COSMOS even when using as few as 1‐direction data. This is made possible by a nonlinear forward‐model that uses the magnitude as an effective prior, for which we derived a simple gradient descent update rule. We synergistically combine this physics‐model with a Variational Network (VN) to leverage the power of deep learning in the VaNDI algorithm. This technique adopts the simple gradient descent rule from NDI and learns the network parameters during training, hence requires no additional parameter tuning. Further, we evaluate NDI at 7 T using highly accelerated Wave‐CAIPI acquisitions at 0.5 mm isotropic resolution and demonstrate high‐quality QSM from as few as 2‐direction data.


  • Highly accelerated multishot echo planar imaging through synergistic machine learning and joint reconstruction

    by Berkin Bilgic, Itthi Chatnuntawech, Mary Kate Manhard, Qiyuan Tian, Congyu Liao, Siddharth S. Iyer, Stephen F. Cauley, Susie Y. Huang, Jonathan R. Polimeni, Lawrence L. Wald, et al.

    Purpose: To introduce a combined machine learning (ML)‐ and physics‐based image reconstruction framework that enables navigator‐free, highly accelerated multishot echo planar imaging (msEPI) and demonstrate its application in high‐resolution structural and diffusion imaging.Methods: Single‐shot EPI is an efficient encoding technique, but does not lend itself well to high‐resolution imaging because of severe distortion artifacts and blurring. Although msEPI can mitigate these artifacts, high‐quality msEPI has been elusive because of phase mismatch arising from shot‐to‐shot variations which preclude the combination of the multiple‐shot data into a single image. We utilize deep learning to obtain an interim image with minimal artifacts, which permits estimation of image phase variations attributed to shot‐to‐shot changes. These variations are then included in a joint virtual coil sensitivity encoding (JVC‐SENSE) reconstruction to utilize data from all shots and improve upon the ML solution.Results: Our combined ML + physics approach enabled Rinplane × multiband (MB) = 8‐ × 2‐fold acceleration using 2 EPI shots for multiecho imaging, so that whole‐brain T2 and T2* parameter maps could be derived from an 8.3‐second acquisition at 1 × 1 × 3‐mm3 resolution. This has also allowed high‐resolution diffusion imaging with high geometrical fidelity using 5 shots at Rinplane × MB = 9‐ × 2‐fold acceleration. To make these possible, we extended the state‐of‐the‐art MUSSELS reconstruction technique to simultaneous multislice encoding and used it as an input to our ML network.Conclusion: Combination of ML and JVC‐SENSE enabled navigator‐free msEPI at higher accelerations than previously possible while using fewer shots, with reduced vulnerability to poor generalizability and poor acceptance of end‐to‐end ML approaches.


  • Open Access

    Highly Accelerated Multishot EPI through Synergistic Machine Learning and Joint Reconstruction

    by Berkin Bilgic, Itthi Chatnuntawech, Mary Kate Manhard, Qiyuan Tian, Congyu Liao, Stephen F. Cauley, Susie Y. Huang, Jonathan R. Polimeni, Lawrence L. Wald, Kawin Setsompop

    Purpose: To introduce a combined machine learning (ML) and physics-based image reconstruction framework that enables navigator-free, highly accelerated multishot echo planar imaging (msEPI), and demonstrate its application in high-resolution structural and diffusion imaging. Methods: Singleshot EPI is an efficient encoding technique, but does not lend itself well to high-resolution imaging due to severe distortion artifacts and blurring. While msEPI can mitigate these artifacts, high-quality msEPI has been elusive because of phase mismatch arising from shot-to-shot variations which preclude the combination of the multiple-shot data into a single image. We employ deep learning to obtain an interim image with minimal artifacts, which permits estimation of image phase variations due to shot-to-shot changes. These variations are then included in a Joint Virtual Coil Sensitivity Encoding (JVC-SENSE) reconstruction to utilize data from all shots and improve upon the ML solution. Results: Our combined ML + physics approach enabled Rinplane x MultiBand (MB) = 8x2-fold acceleration using 2 EPI-shots for multi-echo imaging, so that whole-brain T2 and T2* parameter maps could be derived from an 8.3 sec acquisition at 1x1x3mm3 resolution. This has also allowed high-resolution diffusion imaging with high geometric fidelity using 5-shots at Rinplane x MB = 9x2-fold acceleration. To make these possible, we extended the state-of-the-art MUSSELS reconstruction technique to Simultaneous MultiSlice (SMS) encoding and used it as an input to our ML network. Conclusion: Combination of ML and JVC-SENSE enabled navigator-free msEPI at higher accelerations than previously possible while using fewer shots, with reduced vulnerability to poor generalizability and poor acceptance of end-to-end ML approaches.