Saulo José de Castro Almeida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Saulo José de Castro Almeida has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Alex Sander Clemente de Souza
Universidade Federal de São Carlos
3 shared publications - Renato Silva Nicoletti
University of Sao Paulo, Sao Paulo, Brazil
3 shared publications - Adriano Silva de Carvalho
Department of Civil Engineering, Federal University of São Carlos (UFSCar), São Carlos, Brazil
2 shared publications - Fábio Fleming Leitão
University of Campinas, Campinas, SP, Brazil
1 shared publication - Gustavo Henrique Siqueira
Universidade Estadual de Campinas, Brasil
1 shared publication - Luiz Carlos Marcos Vieira Júnior
Universidade Estadual de Campinas, Brasil
1 shared publication
Latest Publications
- Open Access
- 15 June 2026
- Published by Elsevier in SSRN Electronic Journal
Thermo-Structural Behavior of Steel Industrial Sheds under Fire Using a Coupled CFD–FEA Approach
This study investigates the thermo-structural behavior of steel industrial sheds subjected to fire, with emphasis on the influence of thermal actions on stiffness degradation, displacements, and internal force redistribution. The analysis is carried out within a performance-based framework using a coupled numerical approach, in which thermal fields obtained from computational fluid dynamics (CFD) simulations are transferred to a finite element (FEA) structural model.Several fire scenarios are considered, accounting for variations in ventilation conditions and fire source location. The results show that fire severity, represented by the fuel mass fraction, has a dominant influence on the structural response, leading to significant degradation of steel mechanical properties at elevated temperatures. This degradation results in increased displacements, amplification of internal forces, and progressive loss of structural stiffness.In the most severe scenarios, the numerical solution was terminated by the structural solver due to extreme degradation of material properties in highly heated regions, preventing convergence after local loss of load-bearing capacity. Furthermore, it is observed that regions of maximum temperature do not necessarily coincide with maximum displacements, due to global force redistribution within the structural system.The findings highlight the importance of coupling realistic fire-induced thermal fields with structural analysis for accurate fire performance assessment, contributing to the advancement of performance-based methodologies applied to large-scale steel structures.
- 15 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThermo-Structural Behavior of Steel Industrial Sheds under Fire Using a Coupled CFD–FEA Approach
This study investigates the thermo-structural behavior of steel industrial sheds subjected to fire, with emphasis on the influence of thermal actions on stiffness degradation, displacements, and internal force redistribution. The analysis is carried out within a performance-based framework using a coupled numerical approach, in which thermal fields obtained from computational fluid dynamics (CFD) simulations are transferred to a finite element (FEA) structural model.Several fire scenarios are considered, accounting for variations in ventilation conditions and fire source location. The results show that fire severity, represented by the fuel mass fraction, has a dominant influence on the structural response, leading to significant degradation of steel mechanical properties at elevated temperatures. This degradation results in increased displacements, amplification of internal forces, and progressive loss of structural stiffness.In the most severe scenarios, the numerical solution was terminated by the structural solver due to extreme degradation of material properties in highly heated regions, preventing convergence after local loss of load-bearing capacity. Furthermore, it is observed that regions of maximum temperature do not necessarily coincide with maximum displacements, due to global force redistribution within the structural system.The findings highlight the importance of coupling realistic fire-induced thermal fields with structural analysis for accurate fire performance assessment, contributing to the advancement of performance-based methodologies applied to large-scale steel structures.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Ambiente Construído
- Vol. 25, e141864
Global analysis of buildings under fire situation: influence of beam-column connection and number of stories
Steel-concrete composite connections are crucial for transferring forces between steel and concrete structural elements. Existing literature suggests that most research on composite connections focuses on their isolated behavior. There is a notable lack of research addressing their global behavior, which refers to how these connections interact with the entire structure and its constraints. This study aims to evaluate the impact of the stiffness of steel-concrete composite connections, the location of the fire and the number of stories in buildings subjected to fire conditions. To investigate these factors, eight building models were created using Abaqus® software and subjected to vertical loads. The study found that the 10-story models demonstrated a greater capacity for force redistribution during fires compared to the 3-story models. This was attributed to their stiffer column sections and the presence of a larger number of beams, which facilitated a more efficient load path mechanism, as explained by the Vierendeel effect. Furthermore, the fire resistance time of the buildings was superior to that of isolated connection models, underscoring the importance of considering the overall behavior of structures and the interactions between elements in fire design.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Ambiente Construído
- Vol. 25, e141864
Open AccessGlobal analysis of buildings under fire situation: influence of beam-column connection and number of stories
Steel-concrete composite connections are crucial for transferring forces between steel and concrete structural elements. Existing literature suggests that most research on composite connections focuses on their isolated behavior. There is a notable lack of research addressing their global behavior, which refers to how these connections interact with the entire structure and its constraints. This study aims to evaluate the impact of the stiffness of steel-concrete composite connections, the location of the fire and the number of stories in buildings subjected to fire conditions. To investigate these factors, eight building models were created using Abaqus® software and subjected to vertical loads. The study found that the 10-story models demonstrated a greater capacity for force redistribution during fires compared to the 3-story models. This was attributed to their stiffer column sections and the presence of a larger number of beams, which facilitated a more efficient load path mechanism, as explained by the Vierendeel effect. Furthermore, the fire resistance time of the buildings was superior to that of isolated connection models, underscoring the importance of considering the overall behavior of structures and the interactions between elements in fire design.
- 22 October 2024
- Published by Springer Nature in Fire Technology
- Vol. 61 (4) , 1809-1860
Evaluation of the Behavior of Composite Double Web-Angle Connections at Ambient Temperature and in a Fire Situation
- 22 October 2024
- Published by Springer Nature in Fire Technology
- Vol. 61 (4) , 1809-1860
Evaluation of the Behavior of Composite Double Web-Angle Connections at Ambient Temperature and in a Fire Situation
- 7 December 2023
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 49 (10) , 13231-13260
Evaluation of the Behavior of Steel–Concrete Composite Flush End-Plate Connections at Ambient Temperature and in a Fire Situation
- 7 December 2023
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 49 (10) , 13231-13260
Evaluation of the Behavior of Steel–Concrete Composite Flush End-Plate Connections at Ambient Temperature and in a Fire Situation
- Open Access
- 1 April 2019
- Published by FapUNIFESP (SciELO) in Revista IBRACON de Estruturas e Materiais
- Vol. 12 (2) , 408-428
Analysis of the global second-order effects on irregular reinforced concrete structures using the natural period of vibration
The χT parameter, a simplified method recently presented, allows to estimate the global second-order effects on reinforced concrete frames using the natural period of vibration. This parameter was developed based on the fact that both natural period of vibration and global second-order effects depend essentially on the stiffness and mass matrices of the structure, being thus related. In this paper, numerical analyses are conducted on nine models with different patterns of irregularity in terms of geometry in plan and stiffness. The main purpose of these analyses is to evaluate the applicability of the χT parameter in asymmetric structures as well as that can present torsional modes as the fundamental mode of vibration. In addition, different hypotheses are tested in order to verify the influence of the different modes of vibration in the structural sensitivity to global second-order effects. Results of the simplified analyses were compared to the final bending moment values obtained through a nonlinear numerical analysis considering the P-Δ effect. It is observed that the parameter χT is a promising indicator for a simplified estimation of the global second-order effects for concrete frames, especially when higher modes of vibration are taken account in the analysis.
- 1 April 2019
- Published by FapUNIFESP (SciELO) in Revista IBRACON de Estruturas e Materiais
- Vol. 12 (2) , 408-428
Open AccessAnalysis of the global second-order effects on irregular reinforced concrete structures using the natural period of vibration
The χT parameter, a simplified method recently presented, allows to estimate the global second-order effects on reinforced concrete frames using the natural period of vibration. This parameter was developed based on the fact that both natural period of vibration and global second-order effects depend essentially on the stiffness and mass matrices of the structure, being thus related. In this paper, numerical analyses are conducted on nine models with different patterns of irregularity in terms of geometry in plan and stiffness. The main purpose of these analyses is to evaluate the applicability of the χT parameter in asymmetric structures as well as that can present torsional modes as the fundamental mode of vibration. In addition, different hypotheses are tested in order to verify the influence of the different modes of vibration in the structural sensitivity to global second-order effects. Results of the simplified analyses were compared to the final bending moment values obtained through a nonlinear numerical analysis considering the P-Δ effect. It is observed that the parameter χT is a promising indicator for a simplified estimation of the global second-order effects for concrete frames, especially when higher modes of vibration are taken account in the analysis.