Lucas Roquete
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lucas Roquete has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Arlene Maria Cunha Sarmanho
Universidade Federal de Ouro Preto, Brasil
6 shared publications - Matheus Miranda de Oliveira
Universidade Federal de Ouro Preto, Brasil
3 shared publications - Vinicius Alves
Universidade Federal de Ouro Preto, Brasil
2 shared publications - Adriano Pinto Gomes
Universidade Federal de Ouro Preto
1 shared publication Ana Amélia Oliveira Mazon
Universidade Federal de São João del-Rei, Brazil
1 shared publication- Ana Amélia Oliveira Mazon
UFSJ - Universidade Federal de São João del Rei
1 shared publication
Latest Publications
- Open Access
- 18 October 2026
- Published by Elsevier in SSRN Electronic Journal
Moment resistance of welded I-beam-to-RHS column X-joints: experimental, numerical, and design assessment
This study investigates the moment resistance of unequal-width welded I-beam-to-RHS column X-joints under in-plane bending moments through experimental tests and finite element (FE) analysis. Twelve welded specimens with different non-dimensional geometric parameters, namely the beam-to-column width ratio (β), RHS column slenderness (2γ), and beam-height-to-column-width ratio (η), were tested, including specimens with parameters close to and beyond the validity ranges of the design provisions. Experimental results showed column face plastification in all specimens, with the plastified regions becoming closer as η decreased and the RHS column side walls contributing more to bending moment transfer as β increased. Moment resistance increased with increasing β and η, and decreased with increasing 2γ. FE models were subsequently developed and validated against the experimental results. A parametric study with 300 FE models was then conducted to evaluate the influence of β, 2γ and η on the moment resistance. The FE results were compared with the moment resistance equations of current design provisions within and beyond their prescribed validity ranges. The design provisions generally provided conservative estimates of the moment resistance, with greater variability for models outside the prescribed validity ranges. The results also showed that η influences the connection resistance but is not explicitly accounted for in the current design equation. Therefore, a design equation incorporating β and η was proposed to predict the moment resistance of welded I-beam-to-RHS column X-joints under in-plane bending.
- 18 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMoment resistance of welded I-beam-to-RHS column X-joints: experimental, numerical, and design assessment
This study investigates the moment resistance of unequal-width welded I-beam-to-RHS column X-joints under in-plane bending moments through experimental tests and finite element (FE) analysis. Twelve welded specimens with different non-dimensional geometric parameters, namely the beam-to-column width ratio (β), RHS column slenderness (2γ), and beam-height-to-column-width ratio (η), were tested, including specimens with parameters close to and beyond the validity ranges of the design provisions. Experimental results showed column face plastification in all specimens, with the plastified regions becoming closer as η decreased and the RHS column side walls contributing more to bending moment transfer as β increased. Moment resistance increased with increasing β and η, and decreased with increasing 2γ. FE models were subsequently developed and validated against the experimental results. A parametric study with 300 FE models was then conducted to evaluate the influence of β, 2γ and η on the moment resistance. The FE results were compared with the moment resistance equations of current design provisions within and beyond their prescribed validity ranges. The design provisions generally provided conservative estimates of the moment resistance, with greater variability for models outside the prescribed validity ranges. The results also showed that η influences the connection resistance but is not explicitly accounted for in the current design equation. Therefore, a design equation incorporating β and η was proposed to predict the moment resistance of welded I-beam-to-RHS column X-joints under in-plane bending.
- Open Access
- 1 March 2023
- Published by FapUNIFESP (SciELO) in REM - International Engineering Journal
- Vol. 76 (1) , 21-27
Numerical and theoretical investigation of bolted sleeve connections with rectangular hollow sections
- 1 March 2023
- Published by FapUNIFESP (SciELO) in REM - International Engineering Journal
- Vol. 76 (1) , 21-27
Open AccessNumerical and theoretical investigation of bolted sleeve connections with rectangular hollow sections
- Open Access
- 12 September 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (12)
Coeficiente de flambagem local para seção completa de um perfil U enrijecido de chapa fina com mesa superior inclinada
Este trabalho apresenta um estudo de perfis formados a frio não padronizados por norma, com tipologia U enrijecido (Ue) e mesa superior inclinada em 30°. O objetivo do trabalho é determinar uma equação para o coeficiente de flambagem local (kl) para aplicação do Método da Seção Efetiva (MSE) proposto pela norma brasileira. Os perfis são analisados para o esforço axial de compressão e para esforço de flexão simples. As análises foram realizadas no software GBTUL. Para o estudo paramétrico, foram desenvolvidos 95 perfis com diferentes variações geométricas. A partir das curvas de assinatura de cada análise obtém-se os respectivos valores de carga axial referente a flambagem local e momento fletor associado à flambagem local. Com uso das prescrições normativas brasileiras e dos resultados obtidos, foi possível determinar o valor de kl para cada um dos perfis analisados. Assim, de acordo com o Método da Seção Efetiva apresentado pela norma, foram propostas duas equações para a determinação coeficiente de flambagem local (kl), uma para a compressão centrada e outra para a flexão simples em torno do eixo de maior inércia. As equações mostraram-se adequadas para serem utilizadas no Método da Seção Efetiva para a tipologia de perfil apresentada, U enrijecido com mesa superior inclinada em 30°.
- 12 September 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (12)
Open AccessCoeficiente de flambagem local para seção completa de um perfil U enrijecido de chapa fina com mesa superior inclinada
Este trabalho apresenta um estudo de perfis formados a frio não padronizados por norma, com tipologia U enrijecido (Ue) e mesa superior inclinada em 30°. O objetivo do trabalho é determinar uma equação para o coeficiente de flambagem local (kl) para aplicação do Método da Seção Efetiva (MSE) proposto pela norma brasileira. Os perfis são analisados para o esforço axial de compressão e para esforço de flexão simples. As análises foram realizadas no software GBTUL. Para o estudo paramétrico, foram desenvolvidos 95 perfis com diferentes variações geométricas. A partir das curvas de assinatura de cada análise obtém-se os respectivos valores de carga axial referente a flambagem local e momento fletor associado à flambagem local. Com uso das prescrições normativas brasileiras e dos resultados obtidos, foi possível determinar o valor de kl para cada um dos perfis analisados. Assim, de acordo com o Método da Seção Efetiva apresentado pela norma, foram propostas duas equações para a determinação coeficiente de flambagem local (kl), uma para a compressão centrada e outra para a flexão simples em torno do eixo de maior inércia. As equações mostraram-se adequadas para serem utilizadas no Método da Seção Efetiva para a tipologia de perfil apresentada, U enrijecido com mesa superior inclinada em 30°.
- Open Access
- 1 June 2020
- Published by FapUNIFESP (SciELO) in REM - International Engineering Journal
- Vol. 73 (2) , 153-161
Bearing failure in bolted sleeve connections with circular hollow sections under compression
This article analyzes sleeve connections between circular hollow sections. This type of connection is composed of two tubes connected by bolts to an inner tube with a smaller diameter, and explores the efficiency, aesthetics and resistance of hollow sections subjected to tension and compression. In previous researches, sleeve connections with aligned and crossed bolt dispositions and under axial tension were studied. Herein, the behavior of sleeve connections with aligned bolts and under compression was analyzed. A model to represent the connection using the finite element method was developed, which allowed a numerical analysis with geometric property variations. In the numerical/parametric results, bearing failure was observed in all cases, either in the outer or inner tube. Limiting the number of bolts to 6 and considering that connections have a lower outer thickness than the inner tube, a formulation was proposed to determine the ultimate bearing capacity of sleeve connections under compression and with bearing failure.
- 1 June 2020
- Published by FapUNIFESP (SciELO) in REM - International Engineering Journal
- Vol. 73 (2) , 153-161
Open AccessBearing failure in bolted sleeve connections with circular hollow sections under compression
This article analyzes sleeve connections between circular hollow sections. This type of connection is composed of two tubes connected by bolts to an inner tube with a smaller diameter, and explores the efficiency, aesthetics and resistance of hollow sections subjected to tension and compression. In previous researches, sleeve connections with aligned and crossed bolt dispositions and under axial tension were studied. Herein, the behavior of sleeve connections with aligned bolts and under compression was analyzed. A model to represent the connection using the finite element method was developed, which allowed a numerical analysis with geometric property variations. In the numerical/parametric results, bearing failure was observed in all cases, either in the outer or inner tube. Limiting the number of bolts to 6 and considering that connections have a lower outer thickness than the inner tube, a formulation was proposed to determine the ultimate bearing capacity of sleeve connections under compression and with bearing failure.
- Open Access
- 1 April 2019
- Published by FapUNIFESP (SciELO) in Revista IBRACON de Estruturas e Materiais
- Vol. 12 (2) , 337-370
Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns
This paper presents experimental and theoretical analysis of bolts employed as shear connectors in circular concrete-filled steel tube columns (CFTs). The theoretical results, obtained from ABNT NBR 16239:2013 formulations, were compared with the experimental results. A series of push-out tests were carried out, where the diameter and length of the bolts, the number of connectors and the concrete strength were varied. From the experimental results, it was observed that the equations from ABNT NBR 16239:2013 are conservative. Therefore, it is proposed an adjustment to the formulations in order to consider the concrete confinement. It was also verified that increments in the diameter and the length of the bolt increase the load capacity of the connector. However, the variation of the quantity of bolts and the concrete strength did not interfere in the load capacity.
- 1 April 2019
- Published by FapUNIFESP (SciELO) in Revista IBRACON de Estruturas e Materiais
- Vol. 12 (2) , 337-370
Open AccessExperimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns
This paper presents experimental and theoretical analysis of bolts employed as shear connectors in circular concrete-filled steel tube columns (CFTs). The theoretical results, obtained from ABNT NBR 16239:2013 formulations, were compared with the experimental results. A series of push-out tests were carried out, where the diameter and length of the bolts, the number of connectors and the concrete strength were varied. From the experimental results, it was observed that the equations from ABNT NBR 16239:2013 are conservative. Therefore, it is proposed an adjustment to the formulations in order to consider the concrete confinement. It was also verified that increments in the diameter and the length of the bolt increase the load capacity of the connector. However, the variation of the quantity of bolts and the concrete strength did not interfere in the load capacity.
- Open Access
- 3 May 2018
- Published by FapUNIFESP (SciELO) in Latin American Journal of Solids and Structures
- Vol. 15 (3)
Numerical analysis of truss systems with stiffened flattened end-bars
Circular hollow sections are usually used in long-span roof truss systems. One of the typology for connecting elements in such structures involves the flattening of bar ends. This article presents the numerical analysis of a plane truss composed of circular hollow sections, in which diagonal bars have flattened ends. In this sense, a new flattening typology called stiffened flattening is proposed, characterized by a non-flat geometry, with the creation of stiffeners in the lateral edges of the diagonal flattened ends. The diagonal connecting system with the chord members uses connecting plates. The plates are welded to the chords and the diagonals are connected to latter through a single bolt. The numerical analysis using finite elements method was developed in two stages through ANSYS software with the Parametric Design Language (APDL), in which parameters such as geometry, materials, element types, boundary conditions and loads are specified. A non-linear analysis was performed using shell elements on the chords, diagonals, plates and welds, and contact elements between the diagonals with stiffened flattened ends and the connecting plates. Initially, a numerical study of the connecting node and the stiffened flattened end was performed, and the results directed the modeling of the plane truss. The numerical results were calibrated with the experimental truss results in full scale. The numerical result of the plane truss was also compared to a theoretical study, considering the axial load eccentricity applied in the diagonal with stiffened flattened ends. The study was based on the consideration of combined effects of axial force and bending moment provided by the Brazilian standard ABNT NBR 8800:2008. The final results indicate that the numerical model proposed is efficient and has good correlation with the experimental and theoretical results.
- 3 May 2018
- Published by FapUNIFESP (SciELO) in Latin American Journal of Solids and Structures
- Vol. 15 (3)
Open AccessNumerical analysis of truss systems with stiffened flattened end-bars
Circular hollow sections are usually used in long-span roof truss systems. One of the typology for connecting elements in such structures involves the flattening of bar ends. This article presents the numerical analysis of a plane truss composed of circular hollow sections, in which diagonal bars have flattened ends. In this sense, a new flattening typology called stiffened flattening is proposed, characterized by a non-flat geometry, with the creation of stiffeners in the lateral edges of the diagonal flattened ends. The diagonal connecting system with the chord members uses connecting plates. The plates are welded to the chords and the diagonals are connected to latter through a single bolt. The numerical analysis using finite elements method was developed in two stages through ANSYS software with the Parametric Design Language (APDL), in which parameters such as geometry, materials, element types, boundary conditions and loads are specified. A non-linear analysis was performed using shell elements on the chords, diagonals, plates and welds, and contact elements between the diagonals with stiffened flattened ends and the connecting plates. Initially, a numerical study of the connecting node and the stiffened flattened end was performed, and the results directed the modeling of the plane truss. The numerical results were calibrated with the experimental truss results in full scale. The numerical result of the plane truss was also compared to a theoretical study, considering the axial load eccentricity applied in the diagonal with stiffened flattened ends. The study was based on the consideration of combined effects of axial force and bending moment provided by the Brazilian standard ABNT NBR 8800:2008. The final results indicate that the numerical model proposed is efficient and has good correlation with the experimental and theoretical results.
- Open Access
- 1 December 2017
- Published by FapUNIFESP (SciELO) in REM - International Engineering Journal
- Vol. 70 (4) , 393-398
Influence of shear lag coefficienton circular hollow sections with bolted sleeve connections
The circular hollow sections (CHS) are being widely employed in steel structures around the world, increasing the development of new researches. This article proposes an innovative connection model for circular hollow sections that facilitates and reduces the assembly cost of hollow section structures. The proposed connection is a tube sleeve, used to splice two tubes, composed of an inner tube with a diameter smaller than the connecting tubes, which is connected to the outer tubes by bolts passing through both tubes. This connection can be a cheaper and easier alternative to flange connections, which are widely used in large span tubular trusses. The connection was tested in laboratory under tension loading. The tests made it possible to identify the influence of stress distribution on tubes and the need for the use of a shear lag coefficient. The results of the ultimate load capacity demonstrated the viability of the tube sleeve connection use
- 1 December 2017
- Published by FapUNIFESP (SciELO) in REM - International Engineering Journal
- Vol. 70 (4) , 393-398
Open AccessInfluence of shear lag coefficienton circular hollow sections with bolted sleeve connections
The circular hollow sections (CHS) are being widely employed in steel structures around the world, increasing the development of new researches. This article proposes an innovative connection model for circular hollow sections that facilitates and reduces the assembly cost of hollow section structures. The proposed connection is a tube sleeve, used to splice two tubes, composed of an inner tube with a diameter smaller than the connecting tubes, which is connected to the outer tubes by bolts passing through both tubes. This connection can be a cheaper and easier alternative to flange connections, which are widely used in large span tubular trusses. The connection was tested in laboratory under tension loading. The tests made it possible to identify the influence of stress distribution on tubes and the need for the use of a shear lag coefficient. The results of the ultimate load capacity demonstrated the viability of the tube sleeve connection use
- 1 December 2011
- Published by FapUNIFESP (SciELO) in Ambiente Construído
- Vol. 11 (4) , 113-128
Influência da inércia térmica do solo e da ventilação natural no desempenho térmico: um estudo de caso de um projeto residencial em light steel framing
N tecnologia light steel framing, por ser importada dos Estados Unidos, requer algumas adaptações nos projetos para adequar seu desempenho térmico no Brasil. Neste trabalho avalia-se o desempenho térmico de uma edificação unifamiliar projetada em light steel framing, considerando-se algumas estratégias de ventilação natural e a influência da inércia térmica do solo em Belo Horizonte, MG. Na determinação do comportamento térmico do modelo utiliza-se o programa computacional EnergyPlus, seguindo as seguintes etapas: caracterização da edificação, das condições típicas de exposição ao clima, do perfil de ocupação, das exigências humanas, configuração do sistema de fechamento e avaliação das condições de conforto térmico nos ambientes em concordância com as normas específicas. Observou-se que a estratégia de ventilação natural, quando adequadamente utilizada, em função das condições climáticas locais, proporciona uma melhora significativa no desempenho térmico da edificação. Da mesma forma, em função da topografia do terreno e da característica do projeto, observou-se que a influência da inércia térmica do solo somente se torna positiva quando associada às estratégias de ventilação natural e de sombreamento.
- 1 December 2011
- Published by FapUNIFESP (SciELO) in Ambiente Construído
- Vol. 11 (4) , 113-128
Influência da inércia térmica do solo e da ventilação natural no desempenho térmico: um estudo de caso de um projeto residencial em light steel framing
N tecnologia light steel framing, por ser importada dos Estados Unidos, requer algumas adaptações nos projetos para adequar seu desempenho térmico no Brasil. Neste trabalho avalia-se o desempenho térmico de uma edificação unifamiliar projetada em light steel framing, considerando-se algumas estratégias de ventilação natural e a influência da inércia térmica do solo em Belo Horizonte, MG. Na determinação do comportamento térmico do modelo utiliza-se o programa computacional EnergyPlus, seguindo as seguintes etapas: caracterização da edificação, das condições típicas de exposição ao clima, do perfil de ocupação, das exigências humanas, configuração do sistema de fechamento e avaliação das condições de conforto térmico nos ambientes em concordância com as normas específicas. Observou-se que a estratégia de ventilação natural, quando adequadamente utilizada, em função das condições climáticas locais, proporciona uma melhora significativa no desempenho térmico da edificação. Da mesma forma, em função da topografia do terreno e da característica do projeto, observou-se que a influência da inércia térmica do solo somente se torna positiva quando associada às estratégias de ventilação natural e de sombreamento.