Latest Publications

  • Open Access

    Impact of guideline definitions on right ventricular diameter in echocardiography: an automated analysis in controls and patients with pulmonary hypertension

    by Frida N. Hermansson, Bettia E. Celestin, Shadi P. Bagherzadeh, Gracia Fahed, Everton J. Santana, Neha Mantri, Roham T. Zamanian, Alison L. Marsden, Seraina A. Dual, Michael Salerno, et al.

    Background: To improve standardization, the 2025 American Association of Echocardiography (ASE) guidelines revised the definitions of right ventricular (RV) basal and mid diameters, revising the 2010 ASE and European Society of Cardiology (ESC) definitions. Objectives: (1) To quantify differences in right ventricular (RV) diameter measurements between the 2010 and 2025 ASE guidelines, (2) to determine its impact on the diagnosis of RV enlargement (RVE), and (3) to compare these findings with a novel automated non-linear centerline-based approach. Methods: We analyzed 208 healthy volunteers and 221 patients with pulmonary arterial hypertension (PAH). Using custom cardiac contour analysis (C2A) software, RV diameters were measured across three definitions. The 2010 ASE/ESC defines diameters as the maximal dimension in the basal and mid segments. In contrast, the 2025 ASE defines the basal diameter just below the tricuspid valve and the mid diameter at ~ 50% of RV inflow, both parallel to the annulus. The C2A method uses a non-linear RV centerline as a reference to standardize measurement locations: the mid-point is taken at 50% along the centerline, and the basal diameter is defined as the maximum perpendicular distance within the proximal third of the RV. We quantified nominal and relative definition differences and compared sex-specific RVE prevalence in healthy controls. Diagnostic performance (ROC) and outcome prediction (Cox models) are presented. Results: The median age was 63 years in healthy volunteers (52% male) and 48 years in patients with PAH (22% male), with a median pulmonary vascular resistance index (PVRI) of 22 Wood units·m². Compared to ASE/ESC 2010 definitions, ASE 2025 diameters were 15% (basal) and 20% (mid) lower. Using the 2025 definition in healthy controls, basal RVE was observed in 1% of females and 22% of males, while mid-RVE was present in 6% of females and 35.8% of males. The 2010 definition showed slightly better discrimination for PAH (AUC 0.937 vs. 0.898, p < 0.001). However, the prediction of outcomes was similar between the two definitions, with C-statistics of 0.59 (0.53–0.65) and 0.59 (0.53–0.66), respectively. Conclusion: Differences in guideline definitions of RV diameters are important to consider when implementing them in clinical practice.

  • Open Access

    Lived Experiences of Older Adults Using Wearables With Real-Time Feedback: Phenomenological Study

    by Tien-Ying Lu, Aurora Rosato, Seraina Anne Dual, Sanna Kuoppamäki

    Background: Wearable devices with real-time feedback (WRFs) provide increasing opportunities to enhance physical activity and improve rehabilitation through collecting and processing health-related data. Real-time feedback (RTF) from the device is expected to result in a more dynamic, coordinated, and synchronous rhythmic activity, defined as step-by-step movements mediated by the real-time heart rate feedback. However, age-specific characteristics in the user engagement with WRFs integrating real-time audio feedback have largely remained unexplored. Objective: This study explores the lived experiences of older adults using wearables with RTF to uncover motivations, aspirations, and hindering factors in their engagement with WRFs in rhythmic activity. The study explores narratives that older adults articulate in their previous use of wearables for physical activity, their experiences with WRFs during rhythmic activity, and their meaning-making of the interactive features enhancing the synchronization of the movement during rhythmic activity. Methods: The study was conducted as a qualitative interview study with 18 older adults who used a WRF for rhythmic activity during a 3-week period in their home environment. The wearable used in the study is a chest-band sensor device that helps users to synchronize their steps with their heartbeat through the provision of real-time audio feedback. The material consists of semistructured interviews before and after using the device. Material from the semistructured interviews was analyzed with an interpretative phenomenological analysis method. Results: The study identified four main themes characterizing older adults’ lived experiences with wearables, which are (1) use of wearable technologies without RTF in daily life, (2) embodied rhythmic negotiation with RTF, (3) interpretation of health data with RTF, and (4) temporal trajectories of device engagement with RTF. Older adults demonstrated intentional distancing from wearable technologies rather than simple disuse, prioritizing authentic bodily experiences over external validation. Their engagement was fundamentally relational, mediated through trusted social networks, and required dialogical support for data interpretation. Device-guided movement synchronization created contextually situated challenges that varied significantly based on environmental demands, individual bodily capacity, and exercise routines. Extended temporal engagement transformed participants’ relationships with the technology from initial disruption to potential integration, with RTF serving as a bridge toward enhanced embodied awareness when carefully designed. Conclusions: The study concludes that RTF from the device can enhance synchronization and bodily awareness, but meaningful engagement requires adaptive designs that respect older adults’ authentic movement practices, accommodate their relational approach to technology validation, and allow sufficient time for embodied competency development.


  • Open Access

    Walking-induced inertial effects on the cardiovascular system

    by Aurora Rosato, Emanuele Perra, Eric Rullman, Seraina A. Dual

    Introduction: During exercise, the cardiovascular, respiratory, and locomotor systems interplay dynamically, yet the specific mechanisms of cardiovascular and locomotor interaction during simple rhythmic exercise like walking remain unclear. Computational models constitute a powerful tool to investigate the interplay of networked physiological systems, but while gravitational and postural effects on circulation have been explored, the influence of inertial forces from body motion on hemodynamics has not been addressed.Methods: Here, we present a closed-loop cardiovascular model that incorporates inertial effects during walking. The lumped parameter model includes 25 vascular compartments, a four-chamber heart with valves, pericardial and intrathoracic pressures, interventricular septal dynamics, and a baroreflex mechanism. Inertial effects are modeled as additional hydrodynamic pressure sources in each vascular segment, equivalent to the acceleration of blood mass, caused by gravity and motion. Three protocols are used: a head-up tilt test to validate baroreflex and gravity effects; a synthetic walking simulation with controlled heart rate (HR) and step rate (SR); and a human walking experiment (n=2) linking beat-wise simulated aortic pressure to measured brachial pressure using recorded HR and body acceleration. Beat-wise morphology similarity (K-stat) between experimental and simulated hemodynamic waveforms is quantified with a two-sample Kolmogorov-Smirnov test.Results: The model reproduces expected physiological responses to head-up tilt. During synthetic walking, inertial effects result in pressure augmentation, increasing systolic or diastolic pressure depending on the phase between HR and SR. With SR > HR, phase variability produces a low-frequency “beating” in the pressure waveforms and mean arterial pressure, corresponding to the difference between SR and HR. In the human subject experiment, the model accurately replicates beat-wise pressure changes at varying phase shifts between HR and SR. Quantitative comparison shows a substantial increase in similarity of waveform when hydrodynamic pressure is included (K-stat: 0.123 vs. 0.029 for P1; 0.164 vs. 0.059 for P2).Conclusion: Introducing contributions of body acceleration as an additional hydrodynamic pressure source in the vascular compartments seems a valid way to capture walking-induced inertial effects. This work contributes to the broader effort to characterize physiological network adaptations to exercise and offers a foundation for future research studying and optimizing cardiac-locomotor interaction.


  • Open Access

    Dynamic response of Bluetooth wearable heart rate monitors during rapid changes in heart rate

    by Mariah Sabioni, Jonas Willén, Seraina Anne Dual, Martin Jacobsson

    Objectives. To quantify and evaluate the dynamic response of RR intervals (RRI) and heart rate (HR) measurements of commercially available Bluetooth chest-worn HR monitors during induced rapid changes in HR. Approach. An arbitrary function generator created synthetic ECG signals simulating the heart activity. Different scenarios of rapid changes in HR were simulated several times using: (1) step responses; (2) exercise data; and (3) intermittent exercise data. RRI and HR were recorded using the standard Bluetooth HR service for four wearable monitors: Garmin HRM-Dual, Movesense Active, Polar H10, and Wahoo TRACKR. RRI latency, HR latency, and agreement were evaluated from the reference signal. Main Results. RRI latency (median and IQR) was 0.7(0.5,0.7) s for Garmin, 0.4(0.2,0.5) s for Movesense, 2.6(2.2,2.8) s for Polar, and 2.1(1.9,2.4) s for Wahoo, where results did not differ greatly between tests. HR response latency was different between devices and tests. During intermittent exercise tests, HR latency was 3.3(3.0, 3.3) s for Garmin, 1.0(1.0,1.0) s for Movesense, 2.3(2.3,2.3) s for Polar, and 2.2(2.2,2.3) s for Wahoo, where all devices consistently underestimated HR peaks and overestimated HR valleys, with a greater discrepancy in HR valleys. Significance. Most validation protocols of RRI and HR measured by wearable monitors neglect their dynamic characteristics. The present study demonstrated that manufacturers implemented different digital filters to compute the HR values, limiting the devices' ability to capture rapid HR changes. Open documentation of the processing steps is advised, and use cases involving sharp HR changes - such as intermittent high-intensity training - should rely on beat-to-beat RRI recordings.


  • Open Access

    Physiological Control of Realheart Total Artificial Heart

    by Emanuele Perra, Daniel Jonasson, Shaikh Faisal Zaman, Nils Brynedal Ignell, Michael Broomé, Thomas Finocchiaro, Ina Laura Perkins, Seraina Anne Dual

    Background: Heart failure (HF) affects approximately 64 million patients worldwide, where the heart's impaired ability to pump blood leads to reduced quality of life and a high 5‐year mortality rate. Total artificial hearts (TAHs) offer a promising solution, but to ensure a good quality of life and prolong life expectancy for end‐stage HF patients, TAHs must adapt to the body's varying metabolic demands. Methods: This study evaluates the physiological control performance of the Realheart TAH using a hybrid mock circulation loop that simulates dynamic physiological states, such as sleep, rest, and exercise. The Realheart TAH features a preload‐based control mechanism that adjusts heart rate (HR) and stroke volume (SV) in response to changes in atrial pressure, closely mimicking the native heart's ability to meet varying blood flow demands. The controller's adaptability and robustness were further tested under different levels of pulmonary vascular resistance (PVR), simulating conditions that challenge flow balance. Results: The results demonstrate that the Realheart TAH maintains flow balance between the right and left ventricles and stabilizes atrial pressures across all tested conditions. During simulated exercise, the controller increased cardiac output (CO) by up to 2.1 times from rest while maintaining stable atrial pressures, compared to a maximum increase of 1.2 times without the controller. During sleep, CO decreased by 25%, whereas a decrease of only 5% was observed without the controller. Under increased PVR, the controller adjusted SV and HR to preserve consistent CO and prevent blood volume build‐up in the atria, which could otherwise lead to dangerously high atrial pressures. Conclusion: The physiological control system demonstrated its ability to adapt to rapid transitions between physiological states, although occasional undershoots in pressure were observed during transitions from exercise to rest conditions. This study highlights the Realheart TAH's ability to autonomously adjust to varying physiological conditions and patient needs, showing promise for treating patients with advanced HF. Future work will focus on optimizing the control system to further enhance the device's responsiveness and stability during rapid physiological transitions.


  • Open Access

    Experiments and Simulations to Assess Exercise-Induced Pressure Drop Across Aortic Coarctations

    by Priya J. Nair, Emanuele Perra, Doff B. McElhinney, Alison L. Marsden, Daniel B. Ennis, Seraina A. Dual

    Blood pressure gradient (ΔP) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and guide treatment. While invasive cardiac catheterization is the clinical gold-standard for measuring ΔP, it requires anesthesia and does not capture the effects of daily activity or exercise, potentially underestimating the disease's functional burden. This study aimed to identify patients with functionally significant CoA by evaluating exercise-induced ΔP using a hybrid mock circulatory loop (HMCL). Patient-specific aorta geometries (N = 5) of patients with CoA were generated from 4D-Flow magnetic resonance imaging (MRI) scans, then three dimensional (3D)-printed to create compliant aortic phantoms. The phantoms were incorporated into an HMCL with flow and pressure waveforms tuned to patient-specific rest and exercise states. Matched fluid–structure interaction (FSI) simulations were performed using simvascular for comparison. Results showed that mean ΔP increased nonlinearly with cardiac output (CO), with trends differing between patients. HMCL and FSI simulations exhibited excellent agreement in trends of ΔP change with CO, with minimal error of 1.6±1.1 mmHg. This study emphasizes the need for assessing exercise CoA hemodynamics beyond resting ΔP measurements. Overall, HMCLs and FSI simulations enable assessment of patient-specific hemodynamic response to exercise unattainable in clinical practice, thereby facilitating a comprehensive noninvasive assessment of CoA severity. Further, the excellent agreement between HMCL and FSI results indicates that our validated FSI approach can be used independently to assess exercise CoA hemodynamics hereafter, eliminating the need for repeated complex HMCL experiments.


  • Open Access

    The use of wearables with real-time feedback in rhythmic activity among older adults: A qualitative study (Preprint)

    by Tien-Ying Lu, Jie Che, Aurora Rosato, Seraina Dual, Sanna Kuoppamäki

    BACKGROUND Wearable devices with real-time feedback (WRF) provide increasing opportunities to enhance adherence and improve performance in rehabilitation through collecting and processing health-related data. Real-time feedback from the device is expected to result in a more dynamic, coordinated and synchronous rhythmic activity. However, age-specific characteristics of WRF integrating real-time audio or sound feedback during rhythmic activity have largely remained unexplored. OBJECTIVE The study investigates the use of a wearable device with real-time feedback (WRF) for rhythmic activity among older adults aged 65 and above from the perspective of age heterogeneity. The study explores older adults’ previous use of wearables to track their physical activity, adherence with WRF during rhythmic activity, and the interactive features of WRF enhancing the synchronisation during rhythmic activity. METHODS The study was conducted as a qualitative interview study with 18 older adults who used a WRF for rhythmic activity during a 3-week period at home in Sweden. The wearable used in the study is a chest-band sensor device that helps users to synchronise their steps with their heartbeat through the provision of real-time audio feedback. The material consists of a pre-interview before using the device, and post-interview after using the device. Material from the semi-structured interviews was analysed with an inductive content analysis method. Device-generated data on the usage of WRF for rhythmic activity were used to contextualise the qualitative interview data. RESULTS The study identified three themes in the emergence of age heterogeneity in the use of wearables: (1) Limited or non-use of wearables in physical activity, (2) synchronisation of step and heart rate in device-guided rhythmic activity, and (3) adherence to interaction modalities and audio feedback with a WRF. The contradiction between personal goals and device-related features might hinder the use of wearables, whereas enjoyment, sense of accomplishment and social motivations can drive the uptake of wearables. Device-guided synchronisation required participants to change their natural walking rhythm, which resulted in a sense of disruption during rhythmic activity. Real-time audio feedback was considered convenient in finding the right walking rhythm, which resulted in perceived improvement in synchronisation over time. CONCLUSIONS Age heterogeneity in the use of wearables with real-time feedback is pronounced at three interconnected levels: previous use of wearables, efficiency in device-guided synchronisation and adherence to interaction modalities. The study concludes that real-time feedback can enhance the user experience in synchronisation during rhythmic activity, but the heterogeneity in responding to these modalities require adaptive solutions to ensure long-term engagement with wearables.

  • Open Access

    Evidence of spontaneous cardiac-locomotor coupling during daily activities in healthy adults

    by Aurora Rosato, Matilda Larsson, Eric Rullman, Seraina A. Dual

    Introduction: One way to improve exercise performance and protect heart health is the extended synchronization of the stepping with the diastolic phase of the cardiac cycle. Cardiac-locomotor coupling (CLC) happens when the step rate (SR) equals the heart rate (HR). The extent of CLC in daily life is unknown. This study aims to analyze spontaneous occurrences of CLC during daily activities.Methods: A retrospective analysis of daily life recordings from a wrist-worn sensor was undertaken (PMData, N = 16, 5 months duration). The deviation between HR and SR was used to define CLC (deviation ≤ 1%) and weak CLC (1%< deviation ≤ 10%). The occurrence and the probability of CLC during everyday life were computed from the recordings. The CLC occurrences were stratified depending on the duration and intensity of the physical activity. Finally, a Monte Carlo simulation was run to evaluate the probability of random occurrences of CLC vs. the observed recordings.Results: Participants couple for 5% and weakly couple for 35% of the observational period. The ratio of 1:1 between HR and SR is the dominating occurrence across the study population and this overrepresentation is significant. CLC occurs mostly for long activities. The extent of CLC for various intensities of activity is subject-dependent. The results suggest that CLC is feasible for most people.Conclusions: CLC occurs spontaneously during unsupervised daily activity in everyone in our cohort, which suggests a mechanistic interaction between the cardiac and the locomotor systems. This interaction should be investigated for medical rehabilitation and sports applications in the future.


  • Non-invasive Estimation of Pressure Drop Across Aortic Coarctations: Validation of 0D and 3D Computational Models with In Vivo Measurements

    by Priya J. Nair, Martin R. Pfaller, Seraina A. Dual, Doff B. McElhinney, Daniel B. Ennis, Alison L. Marsden

    Blood pressure gradient (\(\Delta P\)) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and gauge treatment efficacy. Invasive cardiac catheterization is currently the gold-standard method for measuring blood pressure. The objective of this study was to evaluate the accuracy of \(\Delta P\) estimates derived non-invasively using patient-specific 0D and 3D deformable wall simulations. Medical imaging and routine clinical measurements were used to create patient-specific models of patients with CoA (N = 17). 0D simulations were performed first and used to tune boundary conditions and initialize 3D simulations. \(\Delta P\) across the CoA estimated using both 0D and 3D simulations were compared to invasive catheter-based pressure measurements for validation. The 0D simulations were extremely efficient (\(\sim\) 15 s computation time) compared to 3D simulations (\(\sim\) 30 h computation time on a cluster). However, the 0D \(\Delta P\) estimates, unsurprisingly, had larger mean errors when compared to catheterization than 3D estimates (12.1 ± 9.9 mmHg vs 5.3 ± 5.4 mmHg). In particular, the 0D model performance degraded in cases where the CoA was adjacent to a bifurcation. The 0D model classified patients with severe CoA requiring intervention (defined as \(\Delta P\) \(\ge\) 20 mmHg) with 76% accuracy and 3D simulations improved this to 88%. Overall, a combined approach, using 0D models to efficiently tune and launch 3D models, offers the best combination of speed and accuracy for non-invasive classification of CoA severity.