TKToshihiro Kawase

Toshihiro Kawase

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Toshihiro Kawase has a total of 84 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Dynamic Phase Synchrony in Cortical Networks Underlying Conscious Awareness of Flicker

    byĀ Yusuke Uchiyama, Toshimitsu Takahashi, Kensaku Nomoto, Soichiro Fujiki, Teruyuki Fukushima, Narumi Katsuyama, Toshihiro Kawase, Satoko Koganemaru, Kenji Kansaku

    Flickering light sources, such as fluorescent lamps, evoke neural oscillations in the occipital cortex aligning with the flicker frequency; however, this flicker often remains outside conscious awareness. This discrepancy suggests neural mechanisms gating flicker perception. While functional magnetic resonance imaging studies have indicated the involvement of large‐scale frontal and parietal networks in conscious flicker perception, their low temporal resolution limits insights into the underlying dynamic interactions. Using electroencephalography and physically identical stimuli near the critical flicker‐fusion frequency, we investigated the temporal dynamics of phase synchrony and power distribution. Flicker perception was characterized by an early increase in higher beta‐band (19–28 Hz) synchrony, followed by an increase in gamma‐band (29–48 Hz) synchrony between fronto‐parietal and parieto‐occipital regions at approximately 300 ms post‐stimulus. This was accompanied by a global expansion of gamma‐band power from occipital to fronto‐parietal areas—effects not observed during fused perception. Conversely, alpha‐band (8–14 Hz) synchrony between anterior and posterior regions showed a more pronounced reduction specifically during fusion. These findings suggest that frequency‐specific coordination and global information sharing across large‐scale networks may underlie conscious flicker perception. The emergence of broad gamma‐band synchrony at around 300 ms may reflect the integration of local sensory signals into distributed cortical networks. Early beta‐band synchrony may facilitate the initiation of this process through top‐down modulation, whereas attenuated alpha‐band synchrony during fusion may reflect insufficient engagement of these networks. Such dynamic interplay within distributed networks is suggested to be involved in shaping the temporal resolution of visual awareness.

  • Open Access

    Surface Electromyography-Based Wrist Angle Estimation and Robotic Arm Control with Echo State Networks

    byĀ Toshihiro Kawase, Hiroki Ikeda

    Continuous estimation of joint angles based on surface electromyography (sEMG) signals is a promising method for naturally controlling prosthetic limbs and assistive devices. However, conventional methods based on neural networks have limitations such as long training times and calibration burdens. This study investigates the use of an echo state network (ESN), which enables fast training, to estimate wrist joint angles from sEMG. Five participants mimicked the motion of a 1-degree-of-freedom robotic arm by flexing and extending their wrist, while sEMG signals from the wrist flexor and extensor muscles and the robotic arm’s angle were recorded. The ESN was trained to take two sEMG channels as input and the robotic joint angle as output. High-accuracy estimation with a median coefficient of determination R2 = 0.835 was achieved for representative ESN parameters. Additionally, the effects of the reservoir size, spectral radius, and time constant on estimation accuracy were evaluated using data from a single participant. Furthermore, online estimation of joint angles based on sEMG signals enabled successful control of the robotic arm. These results suggest that sEMG-based ESN estimation offers fast, accurate joint control and could be useful for prosthetics and fundamental studies on body perception.


  • Open Access

    Method for Extracting Intentional Motion Using Force Sensor in Hand-held Robotic Forceps and Its Effect on Performance

    byĀ Toshihiro Kawase, Tetsuro Miyazaki, Kenji Kawashima


  • Open Access

    Optical-fiber-type Contact Force Detector for Improving Safety and Workability of Myocardial Biopsy

    byĀ Tomoyuki Umemoto, Kei Sato, Tetsuro Miyazaki, Toshihiro Kawase, Maina Sogabe, Tetsuo Sasano, Kenji Kawashima

  • Open Access

    Investigation of Shape-from-Focus Precision by Texture Frequency Analysis

    byĀ Shinya Onogi, Toshihiro Kawase, Takaaki Sugino, Yoshikazu Nakajima

    This paper reports the precision of shape-from-focus (SFF) imaging according to the texture frequencies and window sizes of a focus measure. SFF is one of various depth measurement techniques for optical imaging, such as microscopy and endoscopy. SFF measures the depth of an object according to focus measure, which is generally computed with a fixed window. The window size affects the performance of SFF and should be adjusted for the texture of an object. In this study, we investigated the precision difference of SFF in texture frequencies and by window size. Two experiments were performed: precision validation in texture frequencies with a fixed window size, and precision validation in various window sizes related to pixel-cycle lengths. The first experimental results showed that a smaller window size could not provide a correct focus measure, and the second results showed that a window size that is approximately equal to a pixel-cycle length of the texture could provide better precision. These findings could potentially contribute to determining the appropriate window size of focus measure operation in shape-from-focus reconstruction.


  • Open Access

    Complex-Valued Wavelet Spectrum Analysis of Respiratory Conditions and Its Feasibility in the Detection of Low-Functional Respiration

    byĀ Yoshikazu Nakajima, Takaaki Sugino, Masashi Kobayashi, Yasuhiro Nakashima, Yohei Wada, Yasuro Okumiya, Koji Yataka, Katsunori Suzuki, Toshihiro Kawase, Shinya Onogi, et al.

    Respiratory monitoring is a significant issue to reduce patient risks and medical staff labor in postoperative care and epidemic infection, particularly after the COVID-19 pandemic. Oximetry is widely used for respiration monitoring in the clinic, but it sometimes fails to capture a low-functional respiratory condition even though a patient has breathing difficulty. Another approach is breathing-sound monitoring, but this is unstable due to the indirect measurement of lung volume. Kobayashi in our team is developing a sensor measuring temporal changes in lung volume with a displacement sensor attached across the sixth and eighth ribs. For processing these respiratory signals, we propose the combination of complex-valued wavelet transform and the correlation among spectrum sequences. We present the processing results and discuss its feasibility to detect a low-functional condition in respiration. The result for detecting low-functional respiration showed good performance with a sensitivity of 0.88 and specificity of 0.88 to 1 in its receiver operating characteristic (ROC) curve.


  • Open Access

    Investigation of Surgical Tool Misplacement in Virtual Fluoroscopy

    byĀ Shinya Onogi, Toshihiro Kawase, Takaaki Sugino, Yoshikazu Nakajima

  • Open Access

    Loss Weightings for Improving Imbalanced Brain Structure Segmentation Using Fully Convolutional Networks

    byĀ Takaaki Sugino, Toshihiro Kawase, Shinya Onogi, Taichi Kin, Nobuhito Saito, Yoshikazu Nakajima

    Brain structure segmentation on magnetic resonance (MR) images is important for various clinical applications. It has been automatically performed by using fully convolutional networks. However, it suffers from the class imbalance problem. To address this problem, we investigated how loss weighting strategies work for brain structure segmentation tasks with different class imbalance situations on MR images. In this study, we adopted segmentation tasks of the cerebrum, cerebellum, brainstem, and blood vessels from MR cisternography and angiography images as the target segmentation tasks. We used a U-net architecture with cross-entropy and Dice loss functions as a baseline and evaluated the effect of the following loss weighting strategies: inverse frequency weighting, median inverse frequency weighting, focal weighting, distance map-based weighting, and distance penalty term-based weighting. In the experiments, the Dice loss function with focal weighting showed the best performance and had a high average Dice score of 92.8% in the binary-class segmentation tasks, while the cross-entropy loss functions with distance map-based weighting achieved the Dice score of up to 93.1% in the multi-class segmentation tasks. The results suggested that the distance map-based and the focal weightings could boost the performance of cross-entropy and Dice loss functions in class imbalanced segmentation tasks, respectively.


  • Open Access

    A Small and High-Speed Driving Mechanism for 3D Shape Measurement in Monocular Endoscopy

    byĀ Yoshikazu Nakajima, Nobuyuki Tanigaki, Takaaki Sugino, Toshihiro Kawase, Shinya Onogi

    Three-dimensional (3D) shape acquisition has been widely introduced to enrich quantitative analysis with the combination of object shape and texture, for example, surface roughness evaluation in industry and gastrointestinal endoscopy in medicine. Shape from focus is a promising technique to measure substance surfaces in 3D space because no occlusion problem appears in principle, as does with stereo shape measurement, which is another commonly used option. We have been developing endoscopic shape measurement devices and shape reconstruction algorithms. In this paper, we propose a mechanism for driving an image sensor reciprocated for the shape from focus of 3D shape measurement in monocular endoscopy. It uses a stepping motor and a planar-end cam, which transforms the motor rotation to imaging sensor reciprocation, to implement the shape from focus of 3D shape measurement in endoscopy. We test and discuss the device in terms of its driving accuracy and application feasibility for endoscopic 3D shape measurement.


  • Open Access

    Computational reproductions of external force field adaption without assuming desired trajectories

    byĀ Hiroyuki Kambara, Atsushi Takagi, Haruka Shimizu, Toshihiro Kawase, Natsue Yoshimura, Nicolas Schweighofer, Yasuharu Koike