TGTingwei Gu

Tingwei Gu

*This is an algorithmically generated author record based on publicly available information.

Tingwei Gu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Fei Shang

    School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China

    3 shared publications
  • Deren Kong

    School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China

    2 shared publications
  • Jing Chen

    Nanjing University of Science and Technology, Nanjing, China

    2 shared publications
  • Chundong Xu

    School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China

    1 shared publication
  • Deren Kong

    Nanjing University of Science and Technology, Nanjing, China

    1 shared publication
  • Ning Liu

    China Key Syst & Integrated Circuit Co Ltd, 777 Jianzhu Rd, Wuxi 214072, Jiangsu Provinc, Peoples R China

    1 shared publication

Latest Publications

  • Absolute quasi-static calibration method of piezoelectric high-pressure sensor based on force sensor

    by Tingwei Gu, Fei Shang, Deren Kong, Chundong Xu

    In this paper, a strain-gauge-type force sensor which can be directly mounted on the existing drop-weight device and used to calibrate the piezoelectric high-pressure sensor is designed. The absolute quasistatic pressure calibration principle and the measurement principle of the strain-gauge-type force sensor are described. Based on the mathematical relation model between force and pressure, the influence factors of pressure calibration accuracy are discussed, and the empirical formula for correcting the peak pressure is obtained. To analyze the mechanical strength of the force sensor, the modal parameters of the force sensor in the impact direction, and the pressure loss in the transmission process, a finite element simulation based on ANSYS software is performed. In addition, the static characteristic of the force sensor and the dynamic characteristic of the new drop-weight system composed of the force sensor, the mounting frame, and weight stacks are analyzed. To verify the accuracy of the empirical formula, the absolute quasistatic pressure calibration experiment is performed based on the calibration device. The final experimental results show that the accuracy of pressure calibration can be effectively improved by means of empirical formula correction. Taking the peak pressure measured by the reference pressure sensors as the standard value, the maximum calculation difference can be reduced from 3.42% (obtained by the direct calculation method) to 0.70% by the empirical formula correction method.


  • A calculation and uncertainty evaluation method for the effective area of a piston rod used in quasi-static pressure calibration

    by Tingwei Gu, Deren Kong, Fei Shang, Jing Chen

    This paper describes the merits and demerits of different sensors for measuring propellant gas pressure, the applicable range of the frequently used dynamic pressure calibration methods, and the working principle of absolute quasi-static pressure calibration based on the drop-weight device. The main factors affecting the accuracy of pressure calibration are analyzed from two aspects of the force sensor and the piston area. To calculate the effective area of the piston rod and evaluate the uncertainty between the force sensor and the corresponding peak pressure in the absolute quasi-static pressure calibration process, a method for solving these problems based on the least squares principle is proposed. According to the relevant quasi-static pressure calibration experimental data, the least squares fitting model between the peak force and the peak pressure, and the effective area of the piston rod and its measurement uncertainty, are obtained. The fitting model is tested by an additional group of experiments, and the peak pressure obtained by the existing high-precision comparison calibration method is taken as the reference value. The test results show that the peak pressure obtained by the least squares fitting model is closer to the reference value than the one directly calculated by the cross-sectional area of the piston rod. When the peak pressure is higher than 150 MPa, the percentage difference is less than 0.71%, which can meet the requirements of practical application.


  • Measurement correction method for force sensor used in dynamic pressure calibration based on artificial neural network optimized by genetic algorithm

    by Tingwei Gu, Deren Kong, Fei Shang, Jing Chen

    We present an optimization algorithm to obtain low-uncertainty dynamic pressure measurements from a force-transducer-based device. In this paper, the advantages and disadvantages of the methods that are commonly used to measure the propellant powder gas pressure, the applicable scope of dynamic pressure calibration devices, and the shortcomings of the traditional comparison calibration method based on the drop-weight device are firstly analysed in detail. Then, a dynamic calibration method for measuring pressure using a force sensor based on a drop-weight device is introduced. This method can effectively save time when many pressure sensors are calibrated simultaneously and extend the life of expensive reference sensors. However, the force sensor is installed between the drop-weight and the hammerhead by transition pieces through the connection mode of bolt fastening, which causes adverse effects such as additional pretightening and inertia forces. To solve these effects, the influence mechanisms of the pretightening force, the inertia force and other influence factors on the force measurement are theoretically analysed. Then a measurement correction method for the force measurement is proposed based on an artificial neural network optimized by a genetic algorithm. The training and testing data sets are obtained from calibration tests, and the selection criteria for the key parameters of the correction model is discussed. The evaluation results for the test data show that the correction model can effectively improve the force measurement accuracy of the force sensor. Compared with the traditional high-accuracy comparison calibration method, the percentage difference of the impact-force-based measurement is less than 0.6% and the relative uncertainty of the corrected force value is 1.95%, which can meet the requirements of engineering applications.