Anna Poston
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anna Poston has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Janice A. Foster
Mackintosh Environmental Architecture Research Unit (MEARU), Glasgow School of Art, Glasgow, UK
1 shared publication Samuel A. Foster
Sam Foster Architects , Dunfermline, Fife , United Kingdom of Great Britain and Northern Ireland
1 shared publication
Latest Publications
- 1 May 2017
- Published by Walter de Gruyter GmbH in Restoration of Buildings and Monuments
- Vol. 23 (2) , 53-66
Building Performance Evaluation – A Design Approach for Refurbishment of a Small Traditional Building in Scotland
In recent years, thermal performance improvements have been applied to an increasing number of historic buildings towards the achievement of the legally binding Scottish carbon dioxide (CO2) emission reductions. Over 20 % of the built environment in Scotland was constructed pre 1919 and the targeting of fabric improvements in these buildings can pose a performance risk if inappropriate measures are applied. This paper discusses through a case study a Building Performance Evaluation (BPE) approach used in conjunction with the design process for refurbishment of a community owned historic building, located in Arisaig, Scotland. The community received funding to improve the energy performance of this nineteenth century stone building and committed to a 75 % reduction in CO2 emissions. BPE was conducted in 2014 as part of the design process and repeated post-refurbishment in 2015 to validate the design. The initial BPE identified high heat losses, inefficient heating and lighting systems that resulted in occupant discomfort, high running costs and consequently the loss of a community facility during the winter months. The resulting BPE quantified improvements to the building fabric, occupant comfort and reduced energy consumption, which advocated this design approach as a beneficial tool for informing historic building refurbishment.
- 1 May 2017
- Published by Walter de Gruyter GmbH in Restoration of Buildings and Monuments
- Vol. 23 (2) , 53-66
Building Performance Evaluation – A Design Approach for Refurbishment of a Small Traditional Building in Scotland
In recent years, thermal performance improvements have been applied to an increasing number of historic buildings towards the achievement of the legally binding Scottish carbon dioxide (CO2) emission reductions. Over 20 % of the built environment in Scotland was constructed pre 1919 and the targeting of fabric improvements in these buildings can pose a performance risk if inappropriate measures are applied. This paper discusses through a case study a Building Performance Evaluation (BPE) approach used in conjunction with the design process for refurbishment of a community owned historic building, located in Arisaig, Scotland. The community received funding to improve the energy performance of this nineteenth century stone building and committed to a 75 % reduction in CO2 emissions. BPE was conducted in 2014 as part of the design process and repeated post-refurbishment in 2015 to validate the design. The initial BPE identified high heat losses, inefficient heating and lighting systems that resulted in occupant discomfort, high running costs and consequently the loss of a community facility during the winter months. The resulting BPE quantified improvements to the building fabric, occupant comfort and reduced energy consumption, which advocated this design approach as a beneficial tool for informing historic building refurbishment.