Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Davide Di Giuseppe has a total of 104 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Lab-on-a-Chip Based Automatic Platform for Continuous Nitrites Sensing in Aquaculture

    by Alexandro Catini, Rosamaria Capuano, Giuseppe Tancredi, Giulio Dionisi, Davide Di Giuseppe, Joanna Filippi, Eugenio Martinelli, Corrado Di Natale

    In aquaculture, the density of fish stock, use of feeding, and surrounding environmental conditions can easily result in an excessive concentration of harmful compounds that require continuous monitoring. Chemical sensors are available for most of these compounds, however, operative conditions and continuous monitoring in water make the development of sensors suitable for long and unattended deployments difficult. A possible solution is the development of engineered automatic labs where the uptake of sample and the contact with water is reduced and the use of a minimal quantity of reagents enables the implementation of reliable chemical assays. In this paper, a platform for automatic chemical assays is presented. The concept is demonstrated with the detection of nitrites based on the well-known colorimetric Griess reaction. The platform is centered around a lab-on-a-chip where reagents and water samples are mixed. The color of the reaction product is measured with low-cost optoelectronic components. Results show the feasibility of the approach with a minimum detectable concentration of about 0.1 mg/L which is below the tolerance level for aquaculture farms.


  • Open Access

    NeuriTES. Monitoring neurite changes through transfer entropy and semantic segmentation in bright-field time-lapse microscopy

    by Arianna Mencattini, Alida Spalloni, Paola Casti, Maria Colomba Comes, Davide Di Giuseppe, Gianni Antonelli, Michele D'ORazio, Joanna Filippi, Francesca Corsi, Hervé Isambert, et al.


  • Metrological Characterization of a Pain Detection System Based on Transfer Entropy of Facial Landmarks

    by Paola Casti, Arianna Mencattini, Joanna Filippi, Michele D'Orazio, Maria Colomba Comes, Davide Di Giuseppe, Eugenio Martinelli

    Pain is an alert state of the human body that can be conveyed to the external world through different modalities. A possible communication channel for human pain is represented by facial expressions, whose role in social interactions has been well established. In this work, the link between pain and transfer entropy, passing through facial expressions, is investigated. A new approach to the vision-based measurement of pain is presented, which is based on transfer entropy among the time-series of facial landmarks positions. The system is composed of three main blocks. A vision-based measurement block for the automatic landmarking and the generation of the time-series from the video-sequences; a second block for the evaluation of transfer entropy; and finally a classification model based on machine learning algorithms for pain assessment. A public database of video sequences of patients experiencing pain in a controlled scenario was used for the characterization of the system in terms of accuracy and precision. Different uncertainty contributions related to realistic signals interruptions and fluctuations were modelled and propagated to provide a comprehensive evaluation of the proposed measurement system. The obtained results indicate that transfer entropy-based approaches can provide great benefits in automatic pain assessment, opening new perspectives for remote management of patients.


  • Open Access

    Rapid Manufacturing of Multilayered Microfluidic Devices for Organ on a Chip Applications

    by Roberto Paoli, Davide Di Giuseppe, Maider Badiola-Mateos, Eugenio Martinelli, Maria Jose Lopez-Martinez, Josep Samitier

    Microfabrication and Polydimethylsiloxane (PDMS) soft-lithography techniques became popular for microfluidic prototyping at the lab, but even after protocol optimization, fabrication is yet a long, laborious process and partly user-dependent. Furthermore, the time and money required for the master fabrication process, necessary at any design upgrade, is still elevated. Digital Manufacturing (DM) and Rapid-Prototyping (RP) for microfluidics applications arise as a solution to this and other limitations of photo and soft-lithography fabrication techniques. Particularly for this paper, we will focus on the use of subtractive DM techniques for Organ-on-a-Chip (OoC) applications. Main available thermoplastics for microfluidics are suggested as material choices for device fabrication. The aim of this review is to explore DM and RP technologies for fabrication of an OoC with an embedded membrane after the evaluation of the main limitations of PDMS soft-lithography strategy. Different material options are also reviewed, as well as various bonding strategies. Finally, a new functional OoC device is showed, defining protocols for its fabrication in Cyclic Olefin Polymer (COP) using two different RP technologies. Different cells are seeded in both sides of the membrane as a proof of concept to test the optical and fluidic properties of the device.


  • Open Access

    A Camera Sensors-Based System to Study Drug Effects on In Vitro Motility: The Case of PC-3 Prostate Cancer Cells

    by Maria Colomba Comes, Arianna Mencattini, Davide Di Giuseppe, Joanna Filippi, Michele D’orazio, Paola Casti, Francesca Corsi, Lina Ghibelli, Corrado Di Natale, Eugenio Martinelli

    Cell motility is the brilliant result of cell status and its interaction with close environments. Its detection is now possible, thanks to the synergy of high-resolution camera sensors, time-lapse microscopy devices, and dedicated software tools for video and data analysis. In this scenario, we formulated a novel paradigm in which we considered the individual cells as a sort of sensitive element of a sensor, which exploits the camera as a transducer returning the movement of the cell as an output signal. In this way, cell movement allows us to retrieve information about the chemical composition of the close environment. To optimally exploit this information, in this work, we introduce a new setting, in which a cell trajectory is divided into sub-tracks, each one characterized by a specific motion kind. Hence, we considered all the sub-tracks of the single-cell trajectory as the signals of a virtual array of cell motility-based sensors. The kinematics of each sub-track is quantified and used for a classification task. To investigate the potential of the proposed approach, we have compared the achieved performances with those obtained by using a single-trajectory paradigm with the scope to evaluate the chemotherapy treatment effects on prostate cancer cells. Novel pattern recognition algorithms have been applied to the descriptors extracted at a sub-track level by implementing features, as well as samples selection (a good teacher learning approach) for model construction. The experimental results have put in evidence that the performances are higher when a further cluster majority role has been considered, by emulating a sort of sensor fusion procedure. All of these results highlighted the high strength of the proposed approach, and straightforwardly prefigure its use in lab-on-chip or organ-on-chip applications, where the cell motility analysis can be massively applied using time-lapse microscopy images.


  • Open Access

    Development of a Sensor Node for Remote Monitoring of Plants

    by Alexandro Catini, Leonardo Papale, Rosamaria Capuano, Valentina Pasqualetti, Davide Di Giuseppe, Stefano Brizzolara, Pietro Tonutti, Corrado Di Natale

    The appraisal of stress in plants is of great relevance in agriculture and any time the transport of living plants is involved. Wireless sensor networks (WSNs) are an optimal solution to simultaneously monitor a large number of plants in a mostly automatic way. A number of sensors are readily available to monitor indicators that are likely related to stress. The most common of them include the levels of total volatile compounds and CO2 together with common physical parameters such as temperature, relative humidity, and illumination, which are known to affect plants’ behavior. Recent progress in microsensors and communication technologies, such as the LoRa protocol, makes it possible to design sensor nodes of high sensitivity where power consumption, transmitting distances, and costs are optimized. In this paper, the design of a WSN dedicated to plant stress monitoring is described. The nodes have been tested on European privet (Ligustrum Jonandrum) kept in completely different conditions in order to induce opposite level of stress. The results confirmed the relationship between the release of total Volatile Organic Compounds (VOCs) and the environmental conditions. A machine learning model based on recursive neural networks demonstrates that total VOCs can be estimated from the measure of the environmental parameters.


  • Open Access

    Polylactic acid, a sustainable, biocompatible, transparent substrate material for Organ-On-Chip, and Microfluidic applications

    by Alfredo E. Ongaro, Davide Di Giuseppe, Ali Kermanizadeh, Allende Miguelez Crespo, Arianna Mencatti, Lina Ghibelli, Vanessa Mancini, Krystian L. Wlodarczyk, Duncan P. Hand, Eugenio Martinelli, et al.

    Organ-on-chips are miniaturised devices aiming at replacing animal models for drug and toxicity studies and studies of complex biological phenomena. The field of Organ-On-Chip has grown exponentially, and has led to the formation of companies providing commercial Organ-On-Chip devices. Yet, it may be surprising to learn that the majority of these commercial devices are made from PDMS, a material widely used in microfluidic prototyping, but which has proven difficult to use in industrial settings and poses a number of challenges to experimentalists, including loss of small compounds. To alleviate these problems, we propose a new substrate for organ-on-chip devices: Polylactic Acid (PLA). PLA is a material derived from renewable resources, and compatible with high volume production such as microinjection moulding. The polymer can be formed into sheets and prototyped into the desired devices in the research lab. The aim of this paper is to assess and prove the suitability of Polylactic acid as substrate material for Organ-on-a-chip applications. Surface properties, biocompatibility, small molecules adsorption and optical properties of PLA are investigated and compared with PDMS and other reference polymers. Significance Organ-On-Chip (OOC) technologies are a powerful and emerging tool that allow the culture of cells constituting an organ and enables scientists, researchers and clinicians to conduct more physiologically relevant experiments without using expensive, and complex animal models. Since the emergence of the first OOC devices, the translation from research to market has happened relatively fast. To date, at least 28 companies are proposing body and tissue on-a chip devices. The material of choice in most commercial organ-on-chip platforms is an elastomer, Polydymethyloxane (PDMS) commonly used in microfluidic R&D. which is subject to poor reproducibility. In this study we showed that Polylactic Acid (PLA), is a suitable material for the production of microfluidic devices. We show that PLA overcome all the drawbacks related to PDMS. PLA can be prototyped in less than 45 minutes from design to test a new transparent no autofluorescent, biocompatible and bio-inert OOC device and is also suitable for mass-manufacturing. PLA-based OOC platform have the potential to transform the OOC industry and provide a sustainable alternative for Lab-On-Chip and point-of-care devices.


  • Open Access

    The influence of spatial and temporal resolutions on the analysis of cell-cell interaction: a systematic study for time-lapse microscopy applications

    by M. C. Comes, P. Casti, A. Mencattini, D. Di Giuseppe, F. Mermet-Meillon, A. De Ninno, M. C. Parrini, L. Businaro, C. Di Natale, E. Martinelli

    Cell-cell interactions are an observable manifestation of underlying complex biological processes occurring in response to diversified biochemical stimuli. Recent experiments with microfluidic devices and live cell imaging show that it is possible to characterize cell kinematics via computerized algorithms and unravel the effects of targeted therapies. We study the influence of spatial and temporal resolutions of time-lapse videos on motility and interaction descriptors with computational models that mimic the interaction dynamics among cells. We show that the experimental set-up of time-lapse microscopy has a direct impact on the cell tracking algorithm and on the derived numerical descriptors. We also show that, when comparing kinematic descriptors in two diverse experimental conditions, too low resolutions may alter the descriptors’ discriminative power, and so the statistical significance of the difference between the two compared distributions. The conclusions derived from the computational models were experimentally confirmed by a series of video-microscopy acquisitions of co-cultures of unlabelled human cancer and immune cells embedded in 3D collagen gels within microfluidic devices. We argue that the experimental protocol of acquisition should be adapted to the specific kind of analysis involved and to the chosen descriptors in order to derive reliable conclusions and avoid biasing the interpretation of results.


  • The Influence of Uncertainty Contributions on Deep Learning Architectures in Vision-Based Evaluation Systems

    by Giuseppina Callari, Arianna Mencattini, Paola Casti, Maria Colomba Comes, Davide Di Giuseppe, Corrado Di Natale, Innocenzo Sammarco, Antonio Pietroiusti, Andrea Magrini, Isidoro Giorgio Lesci, et al.

    Vision-based measurement (VBM) systems are powerful tool to extract quantitative information by acquiring video sequence or static images. When a VBM is applied to the evaluation of nominal properties, such as image characteristics, the term VBM is substituted with vision-based evaluation (VBE) by extending the framework of operation unit to a new concept of evaluation unit (EU) for the image analysis and machine learning phases. To this regard, deep learning (DL) approaches have gained an exponential interest in the research and industrial community, thanks to incredible flexibility toward visual words and the possibility to abandon subjective feature extraction procedures. From such an explosiveness of applications, it emerges the need to conduct studies on the capability of DL strategies to deal with uncertainty contributions, i.e., definitional uncertainty related to the measurand and reference uncertainty that may occur during the calibration process. In order to present a benchmark platform to analyze the effect of the major sources of uncertainties estimated, we use here an atomic force microscopy (AFM) imaging scenario for the evaluation of the effect of nanoparticles exposure on human cells in the laboratory. These studies are nowadays fundamental in toxicity analysis for monitoring the health conditions of workers and for protecting people from atherosclerosis disease. The performance of the proposed VBE-DL system to recognize cell alterations from the AFM images is related to three different sources of uncertainty and a critical analysis of the results achieved is provided.


  • Learning Cancer-Related Drug Efficacy Exploiting Consensus in Coordinated Motility Within Cell Clusters

    by Davide Di Giuseppe, Francesca Corsi, Arianna Mencattini, Maria Colomba Comes, Paola Casti, Corrado Di Natale, Lina Ghibelli, Eugenio Martinelli

    Objective: The ability of cells to collectively move is essential in various biological contexts including cancer metastasis. In this paper, we propose an automatic video analysis tool to correlate the cell movement inhibition with replication block induced by dose-dependent chemotherapy administration. Methods: The novel approach combines individual and collective cell kinematic analysis performed over time-lapse microscopy video frames. Cells are first localized and tracked, and then kinematic descriptors are extracted for each track. Selective track identification is performed assuming diversified cell roles within the same cluster (spontaneously forming groups of cells), and finally individual results are grouped exploiting consensus of coordinated motility within cell clusters. Results: Recognition performance of three different experimental conditions (no drug, 0.5-5 mu M merged in the same condition, and 50 mu M) reached an average accuracy value of 88% over 958 different tracks collected in 36 clusters of diverse dimensions in eight independent experiments. Conclusion: An extensive application of this methodology could give a different point of view of the cancer mechanisms.