Xinchi Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xinchi Yu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Steffen Leonhardt
RWTH Aachen University
6 shared publications - Daniel Teichmann
SDU Health Informatics and Technology, The Maersk Mc-Kinney Moller Institute, University of Southern Denmark, Odense, Denmark
4 shared publications - Anna Boehm
Chair for Medical Information Technology, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany
2 shared publications - Christoph Hoog Antink
KIS*MED (AI Systems in Medicine Lab), Technische Universität Darmstadt, Darmstadt, Germany
2 shared publications Leo Cornelius Bollheimer
Department of Geriatric Medicine (Medical Clinic VI), RWTH Aachen University Hospital, Aachen, Germany
2 shared publications- Wilko Neu
RWTH Aachen University, Aachen Germany
2 shared publications
Latest Publications
- 21 September 2021
- Published by S. Karger AG in Gerontology
- Vol. 68 (6) , 707-719
Non-Contact Measurement of Heart Rate Variability in Frail Geriatric Patients: Response to Early Geriatric Rehabilitation and Comparison with Healthy Old Community-Dwelling Individuals – A Pilot Study
Introduction: Frailty is a central geriatric syndrome characterized by a state of increased physiological vulnerability. As the key components of frailty are difficult to capture in their entirety, easily measurable and reliable surrogate parameters are desirable. Since frailty influences heart rate variability (HRV), HRV may be such a surrogate parameter. HRV is typically acquired by an ECG, which, however, may not be tolerated by all patients; in some, it may even trigger delirium. Therefore, we sought to measure HRV in a non-contact and unobtrusive way through photoplethysmography imaging (PPGI). Using our previously presented HRV estimation algorithm for PPGI, we investigated whether PPGI could reveal (1) HRV differences between frail and non-frail individuals and (2) the influences of early geriatric rehabilitation on HRV. Methods: The study involved 10 frail geriatric inpatients undergoing early geriatric rehabilitation and 10 healthy community-dwelling older adults. All participants underwent a comprehensive geriatric assessment. HRV measurements using a PPGI system and a reference ECG were made at the beginning and the end of the rehabilitation. HRV in terms of LF/HF ratio was analysed for both intra-individual changes during the geriatric rehabilitation and differences between frail geriatric patients and healthy community-dwelling individuals. Results: Across all geriatric patients, the median LF/HF ratio obtained with PPGI was found to be reduced by 0.178 (24.8%) during early geriatric rehabilitation. The assessment at the end of the rehabilitation revealed a simultaneous improvement of the functional state. Moreover, frail geriatric patients had a higher LF/HF ratio than their community-dwelling counterparts. Both observations in PPGI-based HRV were confirmed by the reference. The capability of PPGI to track intra-individual HRV changes was also analysed; a Spearman correlation of ρ = 1.0 between PPGI-based HRV and reference was achieved for 58.8% of the participants. Conclusion: Early geriatric rehabilitation improves the functional state, which is associated with an increased HRV. PPGI is capable of detecting HRV changes/trends in that age group. While the tracking of intra-individual HRV changes is also possible, its reliability needs improvement. Nevertheless, the capabilities demonstrated in our study and the non-contact measurement principle of PPGI emphasize its potential for application in geriatric medicine.
- 21 September 2021
- Published by S. Karger AG in Gerontology
- Vol. 68 (6) , 707-719
Non-Contact Measurement of Heart Rate Variability in Frail Geriatric Patients: Response to Early Geriatric Rehabilitation and Comparison with Healthy Old Community-Dwelling Individuals – A Pilot Study
Introduction: Frailty is a central geriatric syndrome characterized by a state of increased physiological vulnerability. As the key components of frailty are difficult to capture in their entirety, easily measurable and reliable surrogate parameters are desirable. Since frailty influences heart rate variability (HRV), HRV may be such a surrogate parameter. HRV is typically acquired by an ECG, which, however, may not be tolerated by all patients; in some, it may even trigger delirium. Therefore, we sought to measure HRV in a non-contact and unobtrusive way through photoplethysmography imaging (PPGI). Using our previously presented HRV estimation algorithm for PPGI, we investigated whether PPGI could reveal (1) HRV differences between frail and non-frail individuals and (2) the influences of early geriatric rehabilitation on HRV. Methods: The study involved 10 frail geriatric inpatients undergoing early geriatric rehabilitation and 10 healthy community-dwelling older adults. All participants underwent a comprehensive geriatric assessment. HRV measurements using a PPGI system and a reference ECG were made at the beginning and the end of the rehabilitation. HRV in terms of LF/HF ratio was analysed for both intra-individual changes during the geriatric rehabilitation and differences between frail geriatric patients and healthy community-dwelling individuals. Results: Across all geriatric patients, the median LF/HF ratio obtained with PPGI was found to be reduced by 0.178 (24.8%) during early geriatric rehabilitation. The assessment at the end of the rehabilitation revealed a simultaneous improvement of the functional state. Moreover, frail geriatric patients had a higher LF/HF ratio than their community-dwelling counterparts. Both observations in PPGI-based HRV were confirmed by the reference. The capability of PPGI to track intra-individual HRV changes was also analysed; a Spearman correlation of ρ = 1.0 between PPGI-based HRV and reference was achieved for 58.8% of the participants. Conclusion: Early geriatric rehabilitation improves the functional state, which is associated with an increased HRV. PPGI is capable of detecting HRV changes/trends in that age group. While the tracking of intra-individual HRV changes is also possible, its reliability needs improvement. Nevertheless, the capabilities demonstrated in our study and the non-contact measurement principle of PPGI emphasize its potential for application in geriatric medicine.
- 20 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (5) , 1781-1792
Noncontact Monitoring of Heart Rate and Heart Rate Variability in Geriatric Patients Using Photoplethysmography Imaging
Objective: Geriatric patients, especially those with dementia or in a delirious state, do not accept conventional contact-based monitoring. Therefore, we propose to measure heart rate (HR) and heart rate variability (HRV) of geriatric patients in a noncontact and unobtrusive way using photoplethysmography imaging (PPGI). Methods: PPGI video sequences were recorded from 10 geriatric patients and 10 healthy elderly people using a monochrome camera operating in the near-infrared spectrum and a colour camera operating in the visible spectrum. PPGI waveforms were extracted from both cameras using superpixel-based regions of interests (ROI). A classifier based on bagged trees was trained to automatically select artefact-free ROIs for HR estimation. HRV was calculated in the time-domain and frequency-domain. Results: an RMSE of 1.03 bpm and a correlation of 0.8 with the reference was achieved using the NIR camera for HR estimation. Using the RGB camera, RMSE and correlation improved to 0.48 bpm and 0.95, respectively. Correlation for HRV in the frequency-domain (LF/HF-ratio) was 0.50 using the NIR camera and 0.70 using the RGB camera. Conclusion: We were able to demonstrate that PPGI is very suitable to measure HR and HRV in geriatric patients. We strongly believe that PPGI will become clinically relevant in monitoring of geriatric patients. Significance: we are the first group to measure both HR and HRV in awake geriatric patients using PPGI. Moreover, we systematically evaluate the effects of the spectrum (near-infrared vs. visible), ROI, and additional motion artefact reduction algorithms on the accuracy of estimated HR and HRV.
- 20 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (5) , 1781-1792
Noncontact Monitoring of Heart Rate and Heart Rate Variability in Geriatric Patients Using Photoplethysmography Imaging
Objective: Geriatric patients, especially those with dementia or in a delirious state, do not accept conventional contact-based monitoring. Therefore, we propose to measure heart rate (HR) and heart rate variability (HRV) of geriatric patients in a noncontact and unobtrusive way using photoplethysmography imaging (PPGI). Methods: PPGI video sequences were recorded from 10 geriatric patients and 10 healthy elderly people using a monochrome camera operating in the near-infrared spectrum and a colour camera operating in the visible spectrum. PPGI waveforms were extracted from both cameras using superpixel-based regions of interests (ROI). A classifier based on bagged trees was trained to automatically select artefact-free ROIs for HR estimation. HRV was calculated in the time-domain and frequency-domain. Results: an RMSE of 1.03 bpm and a correlation of 0.8 with the reference was achieved using the NIR camera for HR estimation. Using the RGB camera, RMSE and correlation improved to 0.48 bpm and 0.95, respectively. Correlation for HRV in the frequency-domain (LF/HF-ratio) was 0.50 using the NIR camera and 0.70 using the RGB camera. Conclusion: We were able to demonstrate that PPGI is very suitable to measure HR and HRV in geriatric patients. We strongly believe that PPGI will become clinically relevant in monitoring of geriatric patients. Significance: we are the first group to measure both HR and HRV in awake geriatric patients using PPGI. Moreover, we systematically evaluate the effects of the spectrum (near-infrared vs. visible), ROI, and additional motion artefact reduction algorithms on the accuracy of estimated HR and HRV.
- 15 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (3) , 529-539
A Multi-Modal Sensor for a Bed-Integrated Unobtrusive Vital Signs Sensing Array
In this paper we present a novel unobtrusive multimodal sensor for monitoring of physiological parameters featuring capacitive electrocardiogram (cECG), reflective photoplethysmogram (rPPG), and magnetic induction monitoring (MI) in a single sensor. The sensor system comprises sensor nodes designed and optimised for integration into a grid-like array of multiple sensors in a bed and a central controller box for data collection and processing. Hence, it is highly versatile in application and suitable for unobtrusive monitoring of vital signs, both in a professional setting and a home-care environment. The presented hardware design takes both inter-modal interference between cECG and MI into account as well as intra-modal interference due to cross-talk between two MI sensors in close vicinity. In a lab study, we evaluated a prototype of our new multi-modal sensor with two sensor nodes on four healthy subjects. The subjects were lying on the sensors and exercising with a hand grip in order to increase heart rate and thus evaluate our sensor both during changing physiological parameters as well as a wider range of those. Heart beat intervals and heart rate variability were derived from both cECG and rPPG. Breathing intervals were derived from the MI sensor. For heart beat intervals, we achieved an RMSE of 2.3 ms and a correlation of 0.99 using cECG. Similarly, using rPPG, an RMSE of 18.9 ms with a correlation of 0.99 was achieved. With regard to breathing intervals derived from MI, we achieved an RMSE of 1.12 s and a correlation of 0.90.
- 15 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (3) , 529-539
A Multi-Modal Sensor for a Bed-Integrated Unobtrusive Vital Signs Sensing Array
In this paper we present a novel unobtrusive multimodal sensor for monitoring of physiological parameters featuring capacitive electrocardiogram (cECG), reflective photoplethysmogram (rPPG), and magnetic induction monitoring (MI) in a single sensor. The sensor system comprises sensor nodes designed and optimised for integration into a grid-like array of multiple sensors in a bed and a central controller box for data collection and processing. Hence, it is highly versatile in application and suitable for unobtrusive monitoring of vital signs, both in a professional setting and a home-care environment. The presented hardware design takes both inter-modal interference between cECG and MI into account as well as intra-modal interference due to cross-talk between two MI sensors in close vicinity. In a lab study, we evaluated a prototype of our new multi-modal sensor with two sensor nodes on four healthy subjects. The subjects were lying on the sensors and exercising with a hand grip in order to increase heart rate and thus evaluate our sensor both during changing physiological parameters as well as a wider range of those. Heart beat intervals and heart rate variability were derived from both cECG and rPPG. Breathing intervals were derived from the MI sensor. For heart beat intervals, we achieved an RMSE of 2.3 ms and a correlation of 0.99 using cECG. Similarly, using rPPG, an RMSE of 18.9 ms with a correlation of 0.99 was achieved. With regard to breathing intervals derived from MI, we achieved an RMSE of 1.12 s and a correlation of 0.90.
- 23 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (4) , 1105-1114
Noncontact Monitoring of Respiratory Rate in Newborn Infants Using Thermal Imaging
Monitoring of respiratory rate (RR) is very important for patient assessment. In fact, it is considered one of the relevant vital parameters in critical care medicine. Nowadays, standard monitoring relies on obtrusive and invasive techniques which require adhesive electrodes or sensors to be attached to the patient's body. Unfortunately, these procedures cause stress, pain and frequently damage the vulnerable skin of preterm infants. The current paper presents a "black-box" algorithm for remote monitoring of RR in thermal videos. "Black-box" in this context means that the algorithm does not rely on tracking of specific anatomic landmarks. Instead, it automatically distinguishes regions of interest in the video containing the respiratory signal from those containing only noise. To examine its performance and robustness during physiological (phase A) and pathological scenarios (phase B), a study on twelve healthy volunteers was carried out. After a successful validation on adults, a clinical study on eight newborn infants was conducted. A good agreement between estimated RR and ground truth was achieved. In the study involving adult volunteers, a mean root-mean-square error (RMSE) of 0.31 ± 0.09 breaths/min and 3.27 ± 0.72 breaths/min was obtained for phase A and phase B, respectively. In the study involving infants, the mean RMSE hovered around 4.15 ± 1.44 breaths/min. In brief, this paper demonstrates that infrared thermography might become a clinically relevant alternative for the currently available RR monitoring modalities in neonatal care.
- 23 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (4) , 1105-1114
Noncontact Monitoring of Respiratory Rate in Newborn Infants Using Thermal Imaging
Monitoring of respiratory rate (RR) is very important for patient assessment. In fact, it is considered one of the relevant vital parameters in critical care medicine. Nowadays, standard monitoring relies on obtrusive and invasive techniques which require adhesive electrodes or sensors to be attached to the patient's body. Unfortunately, these procedures cause stress, pain and frequently damage the vulnerable skin of preterm infants. The current paper presents a "black-box" algorithm for remote monitoring of RR in thermal videos. "Black-box" in this context means that the algorithm does not rely on tracking of specific anatomic landmarks. Instead, it automatically distinguishes regions of interest in the video containing the respiratory signal from those containing only noise. To examine its performance and robustness during physiological (phase A) and pathological scenarios (phase B), a study on twelve healthy volunteers was carried out. After a successful validation on adults, a clinical study on eight newborn infants was conducted. A good agreement between estimated RR and ground truth was achieved. In the study involving adult volunteers, a mean root-mean-square error (RMSE) of 0.31 ± 0.09 breaths/min and 3.27 ± 0.72 breaths/min was obtained for phase A and phase B, respectively. In the study involving infants, the mean RMSE hovered around 4.15 ± 1.44 breaths/min. In brief, this paper demonstrates that infrared thermography might become a clinically relevant alternative for the currently available RR monitoring modalities in neonatal care.
- Open Access
- 7 November 2017
- Published by MDPI AG in Electronics
- Vol. 6 (4) , 94
Correction of the Unobtrusive ECG Using System Identification
Unobtrusively acquired electrocardiograms (ECG) could substantially improve the comfort of patients. However, such ECGs are not used in clinical practice because (among other reasons) signal deformations impede correct diagnosis of the ECG. Here, methods are proposed for correction of the unobtrusive ECG, based on system identification. Knowing the reference ECG, models were developed to correct the unobtrusively acquired ECG. A finite impulse response (FIR) model, a state space model and an autoregressive model were developed. The models were trained and evaluated on the Goldberger leads recorded from an ECG T-shirt with dry electrodes, and from a gold standard ECG. It was found that the FIR model corrects the unobtrusive ECG with good agreement ( = 0.84 ± 0.10, = 0.65 ± 0.24, = 0.88 ± 0.04), while the other models do not yield significant improvements, or become unstable. The R-peaks were also accurately corrected by the FIR model ( = 0.10 ± 0.10, = 0.14 ± 0.27, = 0.03 ± 0.02). To conclude, the proposed FIR method succeeded in significantly correcting the unobtrusive ECG signal.- 7 November 2017
- Published by MDPI AG in Electronics
- Vol. 6 (4) , 94
Open AccessCorrection of the Unobtrusive ECG Using System Identification
Unobtrusively acquired electrocardiograms (ECG) could substantially improve the comfort of patients. However, such ECGs are not used in clinical practice because (among other reasons) signal deformations impede correct diagnosis of the ECG. Here, methods are proposed for correction of the unobtrusive ECG, based on system identification. Knowing the reference ECG, models were developed to correct the unobtrusively acquired ECG. A finite impulse response (FIR) model, a state space model and an autoregressive model were developed. The models were trained and evaluated on the Goldberger leads recorded from an ECG T-shirt with dry electrodes, and from a gold standard ECG. It was found that the FIR model corrects the unobtrusive ECG with good agreement ( = 0.84 ± 0.10, = 0.65 ± 0.24, = 0.88 ± 0.04), while the other models do not yield significant improvements, or become unstable. The R-peaks were also accurately corrected by the FIR model ( = 0.10 ± 0.10, = 0.14 ± 0.27, = 0.03 ± 0.02). To conclude, the proposed FIR method succeeded in significantly correcting the unobtrusive ECG signal. - Open Access
- 8 November 2016
- Published by MDPI AG in Electronics
- Vol. 5 (4) , 75
A Novel 12-Lead ECG T-Shirt with Active Electrodes
We developed an ECG T-shirt with a portable recorder for unobtrusive and long-term multichannel ECG monitoring with active electrodes. A major drawback of conventional 12-lead ECGs is the use of adhesive gel electrodes, which are uncomfortable during long-term application and may even cause skin irritations and allergic reactions. Therefore, we integrated comfortable patches of conductive textile into the ECG T-shirt in order to replace the adhesive gel electrodes. In order to prevent signal deterioration, as reported for other textile ECG systems, we attached active circuits on the outside of the T-shirt to further improve the signal quality of the dry electrodes. Finally, we validated the ECG T-shirt against a commercial Holter ECG with healthy volunteers during phases of lying down, sitting, and walking. The 12-lead ECG was successfully recorded with a resulting mean relative error of the RR intervals of 0.96% and mean coverage of 96.6%. Furthermore, the ECG waves of the 12 leads were analyzed separately and showed high accordance. The P-wave had a correlation of 0.703 for walking subjects, while the T-wave demonstrated lower correlations for all three scenarios (lying: 0.817, sitting: 0.710, walking: 0.403). The other correlations for the P, Q, R, and S-waves were all higher than 0.9. This work demonstrates that our ECG T-shirt is suitable for 12-lead ECG recordings while providing a higher level of comfort compared with a commercial Holter ECG.
- 8 November 2016
- Published by MDPI AG in Electronics
- Vol. 5 (4) , 75
Open AccessA Novel 12-Lead ECG T-Shirt with Active Electrodes
We developed an ECG T-shirt with a portable recorder for unobtrusive and long-term multichannel ECG monitoring with active electrodes. A major drawback of conventional 12-lead ECGs is the use of adhesive gel electrodes, which are uncomfortable during long-term application and may even cause skin irritations and allergic reactions. Therefore, we integrated comfortable patches of conductive textile into the ECG T-shirt in order to replace the adhesive gel electrodes. In order to prevent signal deterioration, as reported for other textile ECG systems, we attached active circuits on the outside of the T-shirt to further improve the signal quality of the dry electrodes. Finally, we validated the ECG T-shirt against a commercial Holter ECG with healthy volunteers during phases of lying down, sitting, and walking. The 12-lead ECG was successfully recorded with a resulting mean relative error of the RR intervals of 0.96% and mean coverage of 96.6%. Furthermore, the ECG waves of the 12 leads were analyzed separately and showed high accordance. The P-wave had a correlation of 0.703 for walking subjects, while the T-wave demonstrated lower correlations for all three scenarios (lying: 0.817, sitting: 0.710, walking: 0.403). The other correlations for the P, Q, R, and S-waves were all higher than 0.9. This work demonstrates that our ECG T-shirt is suitable for 12-lead ECG recordings while providing a higher level of comfort compared with a commercial Holter ECG.