DSDushyant Vasudeo Sahani

Dushyant Vasudeo Sahani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Dushyant Vasudeo Sahani has a total of 67 co-authors. Here are the top co-authors by number of shared publications:

  • Anushri Parakh

    From the Department of Radiology (A. Pourvaziri, J.C., A.K.), Harvard Catalyst Biostatistics Consulting Unit (J.L.), and Department of Urology (D.S.), Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114; Department of Radiology, Brigham and Women’s Hospital, Boston, Mass (A. Parakh); and Department of Radiology, University of Washington, Seattle, Wash (B.E.).

    5 shared publications
  • Avinash Kambadakone

    Department of Radiology, Massachusetts General Hospital, Boston, MA, USA

    5 shared publications
  • Avinash Kambadakone

    Massachusetts General Hospital, Harvard Medical School

    4 shared publications
  • Ali Pourvaziri

    Massachusetts General Hospital, Harvard Medical School

    3 shared publications
  • Ali Pourvaziri

    Department of Radiology, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114

    3 shared publications
  • Anushri Parakh

    Department of Radiology, Massachusetts General Hospital, Boston, Mass

    3 shared publications

Latest Publications

  • Comparing multi-use syringeless and conventional single-use dual-syringe injectors in contrast-enhanced CT: efficiency, cost, and technologist satisfaction

    by Arash Mahdavi, Gulnoor Sheriff, Brian McKinney, Negar Firoozeh, Charles Watt, Achille Mileto, Dushyant Sahani

    Objectives To compare the operational efficiency, including performance, contrast media (CM) utilization, and technologist satisfaction between a multi-use syringeless power injector (MU-SPI) and a conventional single-use dual-syringe power injector (SU-DSPI). Materials and methods In this IRB-approved, HIPAA-compliant retrospective study, we prospectively recorded randomly selected cases from the first week of the caseload to document equipment setup/release times, including 22 patients (mean age 59) using MU-SPI and 30 patients (mean age 60) using SU-DSPI. In addition, the quality of contrast enhancement was evaluated using 51 randomly selected paired cases where subjects had the same CT study performed with both MU-SPI and SU-DSPI. Finally, we retrospectively recorded unavoidable CM wastage in 688 SU-DSPI cases (one missing). Overall, the healthcare system recorded 9304 cases (mean age, 52 years ± 15; 4532 men) using MU-SPI and 689 cases (mean age, 53 years ± 16; 354 men) using SU-DSPI in the study period from July 2021 to March 2022. Statistical analyses were performed using t-tests, Fisher’s exact test, the Wilcoxon signed-rank test, and multivariate linear regression models. Results Mean injector preparation time per examination was significantly lower for MU-SPI [51.0 (SD: 26.5) seconds] versus SU-DSPI [198.8 (SD: 26.4) seconds] (p < 0.001). SU-DSPI had unavoidable CM wastage of 24.6 (SD: 16.3) mL per exam. Contrast quality showed no significant differences between the groups (p > 0.5). Costs were lower with MU-SPI ($21.70 vs. $25.00). Finally, technologists rated the MU-SPI as having better performance compared to SU-DSPI (p = 0.027). Conclusion MU-SPI significantly enhances operational efficiency and reduces costs with comparable image quality, improving technologist satisfaction. Key Points Question Evaluating how multi-use syringeless power injectors improve CT workflow efficiency and resource utilization amid increasing clinical demand for contrast-enhanced CT examinations. Findings The syringeless injector reduced preparation time, minimized contrast wastage, improved technologist satisfaction, and lowered consumable costs compared with the dual-syringe injector, without compromising image quality. Clinical relevance Implementing multi-use syringeless power injectors can streamline CT workflow and reduce costs. The saved time may enhance patient interaction and preparation, while improved efficiency and lower consumable expenses support overall CT department productivity. Graphical Abstract


  • Top Cited Papers

    Photon-Counting CT: Technology, Current and Potential Future Clinical Applications, and Overview of Approved Systems and Those in Various Stages of Research and Development

    by Fides R. Schwartz, Aaron D. Sodickson, Perry J. Pickhardt, Dushyant V. Sahani, Michael H. Lev, Rajiv Gupta

    This comprehensive, state-of-the-art review focuses on foundational principles, technical implementation, current practice, and potential future clinical applications of photon-counting CT technology.


  • Open Access

    Optimal Abdominal CT Image Quality in Non-Lean Patients: Customization of CM Injection Protocols and Low-Energy Acquisitions

    by Francesco Macri, Elina Khasanova, Bonnie T. Niu, Anushri Parakh, Manuel Patino, Avinash Kambadakone, Dushyant V. Sahani

    We compared the image quality of abdominopelvic single-energy CT with 100 kVp (SECT-100 kVp) and dual-energy CT with 65 keV (DECT-65 keV) obtained with customized injection protocols to standard abdominopelvic CT scans (SECT-120 kVp) with fixed volumes of contrast media (CM). We retrospectively included 91 patients (mean age, 60.7 ± 15.8 years) with SECT-100 kVp and 83 (mean age, 60.3 ± 11.7 years) patients with DECT-65 keV in portovenous phase. Total body weight-based customized injection protocols were generated by a software using the following formula: patient weight (kg) × 0.40/contrast concentration (mgI/mL) × 1000. Patients had a prior abdominopelvic SECT-120 kVp with fixed injection. Iopamidol-370 was administered for all examinations. Quantitative and qualitative image quality comparisons were made between customized and fixed injection protocols. Compared to SECT-120 kVp, customized injection yielded a significant reduction in CM volume (mean difference = 9–12 mL; p ≤ 0.001) and injection rate (mean differences = 0.2–0.4 mL/s; p ≤ 0.001) in all weight categories. Improvements in attenuation, noise, signal-to-noise and contrast-to-noise ratios were observed for both SECT-100 kVp and DECT-65 keV compared to SECT-120 kVp in all weight categories (e.g., pancreas DECT-65 keV, 1.2-attenuation-fold increase vs. SECT-120 kVp; p < 0.001). Qualitative scores were ≥4 in 172 cases (98.8.4%) with customized injections and in all cases with fixed injections (100%). These findings suggest that customized CM injection protocols may substantially reduce iodine dose while yielding higher image quality in SECT-100 kVp and DECT-65 keV abdominopelvic scans compared to SECT-120 kVp using fixed CM volumes.


  • The why, who, how, and what of communicating CT radiation risks to patients and healthcare providers

    by Nayla Mroueh, Anushri Parakh, Jessica Serrao, Susanna I. Lee, Brian H. Eisner, Debra A. Gervais, Avinash R. Kambadakone, Dushyant V. Sahani

    Computed tomography (CT) has witnessed tremendous growth in utilization. Despite its immense benefits, there is a growing concern from the general public and the medical community about the detrimental consequences of ionizing radiation from CT. Anxiety from the perceived risks associated with CT can deter referring physicians from ordering clinically indicated CT scans and patients from undergoing medically necessary exams. This article discusses various strategies for educating patients and healthcare providers on the benefits and risks of CT scanning and salient techniques for effective communication.


  • Comparison of Four Dual-Energy CT Scanner Technologies for Determining Renal Stone Composition: A Phantom Approach

    by Ali Pourvaziri, Anushri Parakh, Jinjin Cao, Joseph Locascio, Brian Eisner, Dushyant Sahani, Avinash Kambadakone

    The performance of dual-energy CT (DECT) for determining renal stone composition varied according to scanner parameters and the DECT technique. Background Studies have investigated the value of various dual-energy CT (DECT) technologies for determining renal stone composition. However, sparse multivendor comparison data exist. Purpose To c...


  • Urogenital Imaging: Kidneys (Lesion Characterization)

    by Ali Pourvaziri, Anushri Parakh, Avinash Kambadakone, Dushyant Sahani

  • Intraductal papillary mucinous neoplasm (IPMN) of the pancreas: recommendations for Standardized Imaging and Reporting from the Society of Abdominal Radiology IPMN disease focused panel

    by Elizabeth M. Hecht, Gaurav Khatri, Desiree Morgan, Stella Kang, Priya R. Bhosale, Isaac R. Francis, Namita S. Gandhi, David M. Hough, Chenchan Huang, Lyndon Luk, et al.

    There have been many publications detailing imaging features of malignant transformation of intraductal papillary mucinous neoplasms (IPMN), management and recommendations for imaging follow-up of diagnosed or presumed IPMN. However, there is no consensus on several practical aspects of imaging IPMN that could serve as a clinical guide for radiologists and enable future data mining for research. These aspects include how to measure IPMN, define reporting terminology, standardize reporting and unify guidelines for surveillance. The Society of Abdominal Radiology (SAR) created multiple Disease-Focused Panels (DFP) comprised multidisciplinary panel members who focus on a particular disease, with the goal to develop ways for radiologists to improve patient care, education, and research. DFP members met to identify the current controversies and limitations of imaging pancreatic IPMN. This paper aims to provide a practical review of the key imaging characteristics of IPMN for trainees and practicing radiologists, to guide uniformity of performance and interpretation of surveillance imaging studies, and to improve communication with clinicians by providing a lexicon and reporting template based on the experience of the SAR-DFP panel members.


  • Open Access

    COVID-19: preparing for second surge and getting back on track for radiology

    by Lionel Tim-Ee Cheng, Marta E Heilbrun, Dushyant Sahani, Bien Soo Tan, Jeffrey S. Klein

    In this opinion piece derived from a webinar organized by the Radiological Society of North America and conducted in the spring of 2020 during the COVID-19 pandemic, leaders from three large North American and Asian academic radiology programs review the strategies employed at their respective institutions to address the impact of the pandemic on their departments. In the first segment, the author describes the approach taken in the radiology department at an 1800-bed Asian hospital system which focuses on the creation of capacity to accommodate over 5000 COVID-19 patients in early 2020, the sustaining of services during the surge, and the development of adaptive mechanisms to address future surges and pandemics. In the second segment, a large southwestern medical system addresses the creation of a long-term strategy to provide imaging services safely for staff and patients while simultaneously utilizing technology to maintain interprofessional connections. The final segment describes how a large multifacility health-care enterprise in the Pacific Northwest of the United States is developing strategies to successfully reemerge from the forced reduction in imaging services experienced during the COVID-19 surge in early 2020.

  • Radiomics Texture Features in Advanced Colorectal Cancer: Correlation with BRAF Mutation and 5-year Overall Survival

    by Adrian A. Negreros-Osuna, Anushri Parakh, Ryan B. Corcoran, Ali Pourvaziri, Avinash Kambadakone, David P. Ryan, Dushyant V. Sahani

    Radiomics texture features from CT images can potentially be used to differentiate wild-type BRAF colorectal cancer tumors from those with BRAF mutation and to predict overall survival in advanced-... PurposeTo explore the potential of radiomics texture features as potential biomarkers to enable detection of the presence of BRAF mutation and prediction of 5-year overall survival (OS) in stage IV...