KMKristin Melton

Kristin Melton

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kristin Melton has a total of 94 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Remote Patient Monitoring for Neonates Discharged on Home Nasogastric Feedings: User-Centered Design Study (Preprint)

    by Kristin Melton, Rebecca D. Henkel, Tanya Cahill, Melissa House, Christa Tabacaru, Kylee Denker, Chunyan Liu, Shelley R. Ehrlich, Heather C Kaplan

  • A Term Infant with Respiratory Distress after Feeding

    by Manan Shah, Shanmukha Mukthapuram, Kristin Melton, Melissa House

  • Reducing Pediatric Unplanned Extubation Across Multiple ICUs Using Quality Improvement

    by Kristin Melton, Caitlin Ryan, Angela Saunders, Julie Zix

    OBJECTIVES: Unplanned extubation (UE) in pediatric patients can result in significant harm or mortality. In our institution, efforts to reduce UE in the ICU were siloed and learnings were not shared. Our goal was to implement shared initiatives across ICUs in a pediatric institution using quality improvement methodology, with the global aim of reducing serious harm caused by UEs. METHODS: The study was conducted as a single-center prospective quality improvement initiative in the pediatric, neonatal, and cardiac ICUs of a large, freestanding academic pediatric hospital. Using the model for improvement and plan–do–study–act cycles, our multidisciplinary team implemented multiple interventions to reduce UEs. The primary measure monitored was the monthly UE rate, defined as the number of UEs per 100 ventilator days, which was tracked over time using statistical control charts. RESULTS: The overall monthly institutional UE rate was reduced from 1.22 UE per 100 ventilator days to 0.2 UE per 100 ventilator days, representing an 84% improvement in rate and reduction of harm. Sixteen percent to 21% of UEs required additional resources because of a difficult airway, and 10% to 22% of UEs resulted in cardiovascular collapse requiring resuscitation. CONCLUSIONS: Significant harm is associated with UEs in pediatric patients. We implemented a bundle for UE reduction across all ICU populations in a pediatric hospital and significantly reduced the rate of UE within our institution and within each individual unit. Allowing variation for implementation of interventions by unit, although targeting a common goal, contributed to overall success and sustainability.


  • Open Access

    The Generalizability of a Medication Administration Discrepancy Detection System: Quantitative Comparative Analysis

    by Eric Kirkendall, Hannah Huth, Benjamin Rauenbuehler, Adam Moses, Kristin Melton, Yizhao Ni

    Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: As a result of the overwhelming proportion of medication errors occurring each year, there has been an increased focus on developing medication error prevention strategies. Recent advances in electronic health record (EHR) technologies allows institutions the opportunity to identify medication administration error (MAE) events in real-time through computerized algorithms. MED.Safe, a software package comprised of medication discrepancy detection algorithms, was developed to meet this need by performing an automated comparison of medication orders to administration records. In order to demonstrate generalizability in other care settings, software such as this must be tested and validated in settings distinct from the development site. Objective: To determine the portability and generalizability of the MED.Safe software at a second site by assessing the performance and fit of the algorithms through comparison of discrepancy rates and other metrics across institutions. Methods: The MED.Safe software package was executed on medication use data from the implementation site to generate prescribing ratios and discrepancy rates. A retrospective analysis of medication prescribing and documentation patterns was then performed on the results and compared to those from the development site to determine the algorithmic performance and fit. Variance in performance from the development site was further explored and characterized. Results: Compared to the development site, the implementation site had lower Audit/order ratios and higher MAR/(Order+Audit) ratios. The discrepancy rates on the implementation site were consistently higher than those from the development site. Three drivers for the higher discrepancy rates included alternative clinical workflow using orders with dosing ranges, a data extract, transfer, and load issue causing modified order data to overwrite original order values in the EHRs, and delayed EHR documentation of verbal orders. Opportunities for improvement were identified and applied using a software update, which decreased false positive discrepancies and improved overall fit. Conclusions: The execution of MED.Safe at a second site was feasible and effective in the detection of medication administration discrepancies. A comparison of medication ordering, administration, and discrepancy rates identified areas where MED.Safe could be improved through customization. One modification of MED.Safe through deployment of a software update improved the overall algorithmic fit at the implementation site. More flexible customizations to accommodate different clinical practice patterns could improve MED.Safe’s fit at new sites.


  • Open Access

    Integrating and Evaluating the Data Quality and Utility of Smart Pump Information in Detecting Medication Administration Errors: Evaluation Study

    by Yizhao Ni, Todd Lingren, Hannah Huth, Kristen Timmons, Krisin Melton, Eric Kirkendall

    Background: At present, electronic health records (EHRs) are the central focus of clinical informatics given their role as the primary source of clinical data. Despite their granularity, the EHR data heavily rely on manual input and are prone to human errors. Many other sources of data exist in the clinical setting, including digital medical devices such as smart infusion pumps. When incorporated with prescribing data from EHRs, smart pump records (SPRs) are capable of shedding light on actions that take place during the medication use process. However, harmoniz-ing the 2 sources is hindered by multiple technical challenges, and the data quality and utility of SPRs have not been fully realized. Objective: This study aims to evaluate the quality and utility of SPRs incorporated with EHR data in detecting medication administration errors. Our overarching hypothesis is that SPRs would contribute unique information in the med-ication use process, enabling more comprehensive detection of discrepancies and potential errors in medication administration. Methods: We evaluated the medication use process of 9 high-risk medications for patients admitted to the neonatal inten-sive care unit during a 1-year period. An automated algorithm was developed to align SPRs with their medica-tion orders in the EHRs using patient ID, medication name, and timestamp. The aligned data were manually re-viewed by a clinical research coordinator and 2 pediatric physicians to identify discrepancies in medication ad-ministration. The data quality of SPRs was assessed with the proportion of information that was linked to valid EHR orders. To evaluate their utility, we compared the frequency and severity of discrepancies captured by the SPR and EHR data, respectively. A novel concordance assessment was also developed to understand the detec-tion power and capabilities of SPR and EHR data. Results: Approximately 70% of the SPRs contained valid patient IDs and medication names, making them feasible for data integration. After combining the 2 sources, the investigative team reviewed 2307 medication orders with 10,575 medication administration records (MARs) and 23,397 SPRs. A total of 321 MAR and 682 SPR dis-crepancies were identified, with vasopressors showing the highest discrepancy rates, followed by narcotics and total parenteral nutrition. Compared with EHR MARs, substantial dosing discrepancies were more commonly detectable using the SPRs. The concordance analysis showed little overlap between MAR and SPR discrepan-cies, with most discrepancies captured by the SPR data. Conclusions: We integrated smart infusion pump information with EHR data to analyze the most error-prone phases of the medication lifecycle. The findings suggested that SPRs could be a more reliable data source for medication error detection. Ultimately, it is imperative to integrate SPR information with EHR data to fully detect and mitigate medication administration errors in the clinical setting.


  • Open Access

    The Generalizability of a Medication Administration Discrepancy Detection System: Quantitative Comparative Analysis (Preprint)

    by Eric Kirkendall, Hannah Huth, Benjamin Rauenbuehler, Adam Moses, Kristin Melton, Yizhao Ni

    BACKGROUND As a result of the overwhelming proportion of medication errors occurring each year, there has been an increased focus on developing medication error prevention strategies. Recent advances in electronic health record (EHR) technologies allow institutions the opportunity to identify medication administration error events in real time through computerized algorithms. MED.Safe, a software package comprising medication discrepancy detection algorithms, was developed to meet this need by performing an automated comparison of medication orders to medication administration records (MARs). In order to demonstrate generalizability in other care settings, software such as this must be tested and validated in settings distinct from the development site. OBJECTIVE The purpose of this study is to determine the portability and generalizability of the MED.Safe software at a second site by assessing the performance and fit of the algorithms through comparison of discrepancy rates and other metrics across institutions. METHODS The MED.Safe software package was executed on medication use data from the implementation site to generate prescribing ratios and discrepancy rates. A retrospective analysis of medication prescribing and documentation patterns was then performed on the results and compared to those from the development site to determine the algorithmic performance and fit. Variance in performance from the development site was further explored and characterized. RESULTS Compared to the development site, the implementation site had lower audit/order ratios and higher MAR/(order + audit) ratios. The discrepancy rates on the implementation site were consistently higher than those from the development site. Three drivers for the higher discrepancy rates were alternative clinical workflow using orders with dosing ranges; a data extract, transfer, and load issue causing modified order data to overwrite original order values in the EHRs; and delayed EHR documentation of verbal orders. Opportunities for improvement were identified and applied using a software update, which decreased false-positive discrepancies and improved overall fit. CONCLUSIONS The execution of MED.Safe at a second site was feasible and effective in the detection of medication administration discrepancies. A comparison of medication ordering, administration, and discrepancy rates identified areas where MED.Safe could be improved through customization. One modification of MED.Safe through deployment of a software update improved the overall algorithmic fit at the implementation site. More flexible customizations to accommodate different clinical practice patterns could improve MED.Safe’s fit at new sites.

  • Open Access

    Integrating and Evaluating the Data Quality and Utility of Smart Pump Information in Detecting Medication Administration Errors: Evaluation Study (Preprint)

    by Yizhao Ni, Todd Lingren, Hannah Huth, Kristen Timmons, Krisin Melton, Eric Kirkendall

    BACKGROUND At present, electronic health records (EHRs) are the central focus of clinical informatics given their role as the primary source of clinical data. Despite their granularity, the EHR data heavily rely on manual input and are prone to human errors. Many other sources of data exist in the clinical setting, including digital medical devices such as smart infusion pumps. When incorporated with prescribing data from EHRs, smart pump records (SPRs) are capable of shedding light on actions that take place during the medication use process. However, harmoniz-ing the 2 sources is hindered by multiple technical challenges, and the data quality and utility of SPRs have not been fully realized. OBJECTIVE This study aims to evaluate the quality and utility of SPRs incorporated with EHR data in detecting medication administration errors. Our overarching hypothesis is that SPRs would contribute unique information in the med-ication use process, enabling more comprehensive detection of discrepancies and potential errors in medication administration. METHODS We evaluated the medication use process of 9 high-risk medications for patients admitted to the neonatal inten-sive care unit during a 1-year period. An automated algorithm was developed to align SPRs with their medica-tion orders in the EHRs using patient ID, medication name, and timestamp. The aligned data were manually re-viewed by a clinical research coordinator and 2 pediatric physicians to identify discrepancies in medication ad-ministration. The data quality of SPRs was assessed with the proportion of information that was linked to valid EHR orders. To evaluate their utility, we compared the frequency and severity of discrepancies captured by the SPR and EHR data, respectively. A novel concordance assessment was also developed to understand the detec-tion power and capabilities of SPR and EHR data. RESULTS Approximately 70% of the SPRs contained valid patient IDs and medication names, making them feasible for data integration. After combining the 2 sources, the investigative team reviewed 2307 medication orders with 10,575 medication administration records (MARs) and 23,397 SPRs. A total of 321 MAR and 682 SPR dis-crepancies were identified, with vasopressors showing the highest discrepancy rates, followed by narcotics and total parenteral nutrition. Compared with EHR MARs, substantial dosing discrepancies were more commonly detectable using the SPRs. The concordance analysis showed little overlap between MAR and SPR discrepan-cies, with most discrepancies captured by the SPR data. CONCLUSIONS We integrated smart infusion pump information with EHR data to analyze the most error-prone phases of the medication lifecycle. The findings suggested that SPRs could be a more reliable data source for medication error detection. Ultimately, it is imperative to integrate SPR information with EHR data to fully detect and mitigate medication administration errors in the clinical setting.

  • Open Access

    Smart pumps improve medication safety but increase alert burden in neonatal care

    by Kristin R. Melton, Kristen Timmons, Kathleen E. Walsh, Jareen K. Meinzen-Derr, Eric Kirkendall

    Background: Smart pumps have been widely adopted but there is limited evidence to understand and support their use in pediatric populations. Our objective was to assess whether smart pumps are effective at reducing medication errors in the neonatal population and determine whether they are a source of alert burden and alert fatigue in an intensive care environment. Methods: Using smart pump records, over 370,000 infusion starts for continuously infused medications used in neonates and infants hospitalized in a level IV NICU from 2014 to 2016 were evaluated. Attempts to exceed preset soft and hard maximum limits, percent variance from those limits, and pump alert frequency, patterns and salience were evaluated. Results: Smart pumps prevented 160 attempts to exceed the hard maximum limit for doses that were as high as 7–29 times the maximum dose and resulted in the reprogramming or cancellation of 2093 infusions after soft maximum alerts. While the overall alert burden from smart pumps for continuous infusions was not high, alerts clustered around specific patients and medications, and a small portion (17%) of infusions generated the majority of alerts. Soft maximum alerts were often overridden (79%), consistent with low alert salience. Conclusions: Smart pumps have the ability to improve neonatal medication safety when compliance with dose error reducing software is high. Numerous attempts to administer high doses were intercepted by dosing alerts. Clustered alerts may generate a high alert burden and limit safety benefit by desensitizing providers to alerts. Future efforts should address ways to improve alert salience.


  • Open Access

    Smart Pumps Improve Medication Safety but Increase Alert Burden in Neonatal Care

    by Kristin Melton, Kristen Timmons, Kathleen E Walsh, Jareen K Meinzen-Derr, Eric Kirkendall

    Background: Smart pumps have been widely adopted but there is limited evidence to understand and support their use in pediatric populations. Our objective was to assess whether smart pumps are effective at reducing medication errors in the neonatal population and determine whether they are a source of alert burden and alert fatigue in an intensive care environment. Methods: Using smart pump records, over 370,000 infusion starts for continuously infused medications used in neonates and infants hospitalized in a level IV NICU from 2014-2016 were evaluated. Attempts to exceed preset soft and hard maximum limits, percent variance from those limits, and pump alert frequency, patterns and salience were evaluated. Results: Smart pumps prevented 160 attempts to exceed the hard maximum limit for doses that were as high as 7-29 times the maximum dose and resulted in the reprogramming or cancellation of 2093 infusions after soft maximum alerts. While the overall alert burden from smart pumps for continuous infusions was not high, alerts clustered around specific patients and medications, and a small portion (17%) of infusions generated the majority of alerts. Soft maximum alerts were often overridden (79%), consistent with low alert salience. Conclusions: Smart pumps have the ability to improve neonatal medication safety when compliance with dose error reducing software is high. Numerous attempts to administer high doses were intercepted by dosing alerts. Clustered alerts may generate a high alert burden and limit safety benefit by desensitizing providers to alerts. Future efforts should address ways to improve alert salience.

  • Open Access

    Smart Pumps Improve Medication Safety but Increase Alert Burden in Neonatal Care

    by Kristin Melton, Kristen Timmons, Kathleen E Walsh, Jareen K Meinzen-Derr, Eric Kirkendall

    Background: Smart pumps have been widely adopted but there is limited evidence to understand and support their use in pediatric populations. Our objective was to assess whether smart pumps are effective at reducing medication errors in the neonatal population and determine whether they are a source of alert burden and alert fatigue in an intensive care environment. Methods: Using smart pump records, over 370,000 infusion starts for continuously infused medications used in neonates and infants hospitalized in a level IV NICU from 2014-2016 were evaluated. Attempts to exceed preset soft and hard maximum limits, percent variance from those limits, and pump alert frequency, patterns and salience were evaluated. Results: Smart pumps prevented 160 attempts to exceed the hard maximum limit for doses that were as high as 7-29 times the maximum dose and resulted in the reprogramming or cancellation of 2093 infusions after soft maximum alerts. While the overall alert burden from smart pumps for continuous infusions was not high, alerts clustered around specific patients and medications, and a small portion (17%) of infusions generated the majority of alerts. Soft maximum alerts were often overridden (79%), consistent with low alert salience. Conclusions: Smart pumps have the ability to improve neonatal medication safety when compliance with dose error reducing software is high. Numerous attempts to administer high doses were intercepted by dosing alerts. Clustered alerts may generate a high alert burden and limit safety benefit by desensitizing providers to alerts. Future efforts should address ways to improve alert salience.